Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Hand Surg Am ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38597836

RESUMO

PURPOSE: The distal radioulnar joint (DRUJ) is supported by an array of dynamic and static stabilizers, of which the triangular fibrocartilage complex (TFCC) is the most important, and the distal interosseous ligament is next in importance. The distal oblique band (DOB) is an identifiable component of the distal interosseous ligament, found in a subset of the population. Our objective was to determine the contribution of the DOB to DRUJ stability in the presence of a disrupted TFCC. METHODS: Twenty-three above-elbow specimens were prepared by removing the TFCC and the DRUJ joint capsule, preserving the distal interosseous ligament and the pronator quadratus. Cadavers were stratified into two groups-those with, and those without a DOB. A bone plate and screws were attached to the ulna; then, a transverse load was applied to failure, creating a diastasis between the radius and ulna. RESULTS: The group with a DOB had a mean load at failure of 160.7 ± 46.5 N. The group without a DOB had a mean load at failure of 148.0 ± 26.3 N. Stiffness prior to failure was 16.9 N/mm in the group with a DOB and 12.4 N/mm in the group without a DOB. CONCLUSIONS: The current results indicate that the DOB may not substantially contribute to DRUJ stability in the presence of a disrupted TFCC. CLINICAL RELEVANCE: Stability of the DRUJ after TFCC injury may not be substantially improved by the presence of a DOB. Thus, the clinical importance of DOB reconstruction remains unclear.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38609004

RESUMO

BACKGROUND: The incidence of radial head fractures is increasing, and radial head arthroplasty (RHA) is being more frequently used as treatment for irreparable fractures. Our objective was to compare radiocapitellar pressure between the native joint and 2 radial head prosthesis conditions: (1) a prosthetic head that was aligned to the forearm axis of rotation and (2) the same prosthesis with an axisymmetric nonaligned head. METHODS: Ten cadaveric specimens received a pressfit radial head prosthesis (Align; Skeletal Dynamics) for both prosthetic testing conditions. Anatomic alignment (AL) was defined as the prosthetic head aligned to the forearm axis of rotation. Axisymmetric alignment (AX) was defined as the prosthetic radial head aligned to the axis of the prosthetic stem. Axial load was applied with the elbow in extension and the forearm pronated. Data were collected using a Tekscan 4000 sensor. RESULTS: The mean pressure in the AL and AX groups were significantly higher than the mean pressure in the native joint. Compared with the native joint, the mean pressure was 19% higher in the AL group and 56% higher in the AX group. Peak pressure beyond 5 MPa occurred in 0 specimens in the native joint group, in 1 specimen (10%) in the AL group, and in 5 specimens (50%) in the AX group. DISCUSSION: Our results demonstrated that a pressfit radial head prosthesis aligned with the forearm axis of rotation yields capitellar pressures that were more similar to the native condition than a nonaligned pressfit prosthesis. These findings suggest that anatomic alignment may optimize capitellar wear properties, improving the long-term durability of radial head arthroplasty.

3.
J Hand Surg Glob Online ; 6(1): 62-67, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38313626

RESUMO

Purpose: The goal of surgical management for unstable elbow injuries is the restoration of joint concentricity and stability. After internal fixation, concerns may exist regarding instability or durability of the fixation construct. Historically, these scenarios were treated with options such as transarticular pinning or external fixation. Recently, an internal joint stabilizer (IJS) that allows postoperative mobilization was introduced. Our objective was to systematically review the literature to aggregate the clinical and biomechanical evidence for the IJS of the elbow. Methods: A systematic review of the PubMed and Google Scholar databases was performed, following the PRISMA guidelines. The search results were narrowed from 2015 through 2023 to coincide with the inception of the device being reviewed. Results: A total of nine retrospective reports on the IJS (N = 171) cases at a mean follow-up of 10.8 months were included. The pooled rate of implant failure was 4.4%, and recurrent instability was 4.1%. Additionally, the we included seven case reports and two biomechanical reports. Conclusions: The aggregate literature describes satisfactory clinical outcomes with low rates of recurrent instability and device failure for the IJS of the elbow. The limited biomechanical investigations conclude efficacy for stability profiles. Clinical relevance: Across a spectrum of unstable elbow cases, the IJS prevented recurrent instability during the early postoperative period. Notably, the device requires an additional procedure for removal, and the long-term impact of the retained devices is currently unclear.

4.
J Hand Surg Eur Vol ; 48(2_suppl): 18S-26S, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37704026

RESUMO

Fractures of the phalanges encompass a wide range of injury patterns with variable articular and soft tissue involvement. The goals of treatment whether conservative or surgical are the restoration of function while limiting the risk of complications. An armamentarium of fixation options allows the surgeon to appropriately treat these fractures with the intention of initiating early postoperative mobilization. Previous publications report variable rates of complications following internal fixation of phalangeal fractures which represents an unsolved problem. It is incumbent on the surgeon to utilize meticulous surgical technique, achieve anatomic reduction with stable fixation and initiate early postoperative mobilization where indicated. In the following text, we review the management of most types of phalangeal fractures, except fracture-dislocations of the proximal interphalangeal joint. These injuries comprise a wide spectrum of presentation; thus, an understanding of anatomical and mechanical principles is integral to achieving a successful outcome.


Assuntos
Falanges dos Dedos da Mão , Fratura-Luxação , Fraturas Ósseas , Humanos , Fraturas Ósseas/cirurgia , Extremidades , Falanges dos Dedos da Mão/cirurgia , Articulações
5.
J Hand Surg Eur Vol ; 48(2_suppl): 27S-34S, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37704028

RESUMO

Although proximal interphalangeal joint dislocations are generally straightforward to treat, fracture-dislocations are among the most difficult hand injuries to manage. Fracture patterns range from simple to treat palmar plate avulsion fractures to complex, unstable pilon fractures of the base of the middle phalanx, where achieving adequate reduction and fixation can be extremely difficult. Moreover, these fractures may present sub-acutely or chronically, which greatly adds to the complexity of the case. It is therefore no surprise that clinical results vary and are often difficult to predict. We will discuss the clinical presentations, the various dislocation and fracture-dislocation patterns, treatment options and the complications of these injuries.


Assuntos
Fratura-Luxação , Fraturas Ósseas , Luxações Articulares , Humanos , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/cirurgia , Fratura-Luxação/diagnóstico por imagem , Fratura-Luxação/cirurgia , Extremidades , Articulações , Fraturas Ósseas/cirurgia
6.
Tech Hand Up Extrem Surg ; 27(4): 214-219, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37439145

RESUMO

We describe a medial approach to the coronoid where the flexor-pronator mass is released from its humeral origin by creating a proximally based tendinous flap. This technique facilitates access to the coronoid, preservation of the medial collateral ligament origin, and repair of the flexor-pronator mass. This approach has utility for all coronoid fracture variations but especially the O'Driscoll anteromedial subtype 3, which includes fractures of the sublime tubercle, the anteromedial facet, and the coronoid tip.


Assuntos
Articulação do Cotovelo , Fraturas Ósseas , Fraturas da Ulna , Humanos , Fraturas da Ulna/cirurgia , Articulação do Cotovelo/cirurgia , Fraturas Ósseas/cirurgia , Úmero , Fixação Interna de Fraturas/métodos
7.
J Hand Surg Glob Online ; 5(4): 401-406, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37521551

RESUMO

Purpose: Kienböck's disease consists of intrinsic and extrinsic characteristics that coalesce into a pathology with multifactorial etiology. Mechanical, morphological, and vascular factors have been identified as contributory. Radial osteotomy is one of the most commonly used surgical treatment for late-stage Kienböck's disease. Despite its frequent use and reported value, the specifics of radial osteotomy have not been described in aggregate. Our objective was to review the recent literature for descriptions of the radial osteotomy techniques used for treatment of Kienböck's disease. Methods: The inclusion criteria for the systematic review were as follows: (1) patients aged >18 years, (2) a publication date no older than 2012, and (3) a complete description of the distal radius osteotomy technique, including verbiage that specified numeric dimensions of bony resection or verbiage that detailed a goal in terms of a radiographic parameter that would guide the bony resection. Results: The studies were grouped according to the stated description of radial osteotomy. This process yielded the following three main groups: (1) studies that used radial shortening, (2) studies that used lateral closing wedge osteotomy or combined lateral closing wedge with radial shortening, and (3) novel osteotomy descriptions. Conclusions: The Kienböck's disease literature predominantly describes an osteotomy to shorten the radius by 2-3 mm. In some studies, the degree of radial shortening corresponded to the value necessary to achieve near-neutral ulnar variance. The common goal in using lateral closing wedge osteotomy was to achieve a radial inclination of 5° to 15°. Unique wedge resections, some with multiplanar corrections, have been recently described with each purporting specific advantages. Clinical relevance: Our findings support the premise of mechanical and biologic efficacy for radial osteotomy, with satisfactory results being reported across a wide spectrum of osteotomy techniques.

8.
Hand (N Y) ; : 15589447231151434, 2023 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-36752100

RESUMO

BACKGROUND: Revision of radial head arthroplasty (RHA) may be indicated in cases of prosthesis loosening and malposition. Inherent difficulties in revision surgery include poor bone stock and disrupted soft tissue envelope. Although cases of RHA used for revision of failed RHA are rare, there is reasonable expectation for increasing frequency of these cases due to the increasing incidence of primary RHA. Furthermore, there is an increasing demand for postoperative recovery of function; thus, surgeons may consider revising a failed RHA to a new RHA. We report on series of failed RHA which were revised to a new radial head prosthesis. METHODS: A retrospective review was performed at multiple institutions for a single radial head prosthesis used for revision of a failed radial head prosthesis. Clinical and radiographic outcomes were collected with a minimum of 1 year of follow-up. RESULTS: Across 11 patients at a mean follow-up of 45.1 months, the mean Mayo Elbow Performance Score was 81.7; mean Disabilities of the Arm, Shoulder, and Hand scores were 24.4; and mean Visual Analog Scale for pain was 0.6. Radiographic analysis yielded no evidence of capitellar wear or stem loosening. CONCLUSION: A radial head prosthesis can produce satisfactory results when used for revision of a failed prosthesis. Inherent difficulties in revision surgery include the potential for reduced bone stock and a disrupted soft tissue envelope. Elements of prosthesis design which may contribute to effectively managing revision surgery include a long stem with in-growth surface and prosthetic head alignment to the axis of forearm rotation.

9.
J Foot Ankle Surg ; 62(1): 91-95, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35752550

RESUMO

Although structural allograft has been previously described as acceptable practice for reconstructive foot and ankle surgery, results for an allograft bone wedge in Lapidus arthrodesis are unknown. Additionally, there is no consensus on the superiority of a single fixation construct in Lapidus cases. Our objective was (1) to report union rates for Lapidus arthrodesis with and without the use of an allograft bone wedge and (2) to determine if fixation construct impacts rates of union when using structural allograft. A review was performed for Lapidus cases with fixation constructs of 2 crossed compression screws (CS) and a medial locking plate with single transarticular screw (MPS), both with and without use of an allograft bone wedge. Inclusion required a CT scan to evaluate bony union. There was no significant difference in union rates (p = .41) between the use (90%) and the nonuse (97%) of an allograft bone wedge. Union rates were significantly different (p = .04) when comparing CS fixation (85%) and MPS fixation (98%). The comparative results between the fixation constructs highlight the importance of compression across the arthrodesis site as part of a robust fixation construct. Our findings demonstrate that the use of an allograft bone wedge in Lapidus arthrodesis may mitigate complications due to metatarsal shortening while providing satisfactory rates of union.


Assuntos
Hallux Valgus , Ossos do Metatarso , Humanos , Hallux Valgus/cirurgia , Tomografia Computadorizada por Raios X , Artrodese/métodos , Ossos do Metatarso/cirurgia , Placas Ósseas , Aloenxertos
10.
J Hand Surg Glob Online ; 4(6): 328-331, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36425377

RESUMO

Purpose: Distal radius fractures are the most common fractures in adults. Because of the prevalence of these injuries, patients may present with a repeat distal radius fracture on the same wrist through the site of a malunion. We clinically refer to this as an acute on chronic distal radius fracture. In this setting, the restoration of acceptable alignment can be challenging. There is little guidance in the literature for the management of these fractures. We report our experience with acute on chronic distal radius fractures. The secondary fracture plane was used to correct the prior deformity, and the construct was fixated with a fixed angle volar locking plate. Methods: Records of patients with malunion of the distal radius who experienced an acute fracture of the ipsilateral distal radius were reviewed. Inclusion required treatment with open reduction internal fixation using a distal fragment first technique and a volar locking plate through the extended flexor carpi radialis approach. Clinical outcomes and complications were collected. Results: Across 13 patients, the mean follow-up term was 13 months (range, 6-40 months). Radiographic union was noted in all patients. The mean visual analog scale score for pain was 1.8, and the mean Quick Disabilities of the Arm, Shoulder, and Hand score was 21.9. There were no recorded complications. Conclusion: Our results and described technique provide reproducible guidance for the management of acute on chronic distal radius fractures. These cases can be managed using the secondary fracture plane, a distal fragment first technique, and a volar locking plate to correct the preexisting deformity. Type of study/level of evidence: Therapeutic IV.

11.
J Wrist Surg ; 11(3): 214-218, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35837594

RESUMO

The volar rim of the distal radius is the only bony restraint to volar carpal subluxation. Higher loads across the volar rim require stable and rigid fixation to maintain reduction and allow healing while rehabilitation begins. Volar marginal fragments are not amenable to buttressing by fixed angle volar locking plates. Appropriate management of volar marginal fragments comprises two steps-recognition of their presence and rigid anatomical repair. The best opportunity for success in the presence of a volar marginal fragment is its adequate initial treatment. The purpose of this review is to reinforce the importance of a complete preoperative and intraoperative evaluation of distal radius fractures. Volar marginal fragments can easily be overlooked even following initial reduction and fixation. Understanding the relevant anatomy and loading parameters can facilitate intraoperative decisions on approach and fixation, which are integral to achieving optimal clinical outcomes.

12.
Tech Hand Up Extrem Surg ; 26(4): 214-217, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-35383724

RESUMO

A variety of fixation options exist for treatment of unstable proximal phalanx fractures. Variables which require consideration include the strength of fixation, the invasiveness of the technique and the postoperative rehabilitation protocol. Here we present a minimally invasive technique for dual headless compression screw fixation of proximal phalanx fractures which reduces extensor tendon violation and allows early motion in the immediate postoperative period.


Assuntos
Falanges dos Dedos da Mão , Fraturas Ósseas , Humanos , Falanges dos Dedos da Mão/cirurgia , Amplitude de Movimento Articular , Parafusos Ósseos , Fraturas Ósseas/cirurgia , Tendões , Fixação Interna de Fraturas/métodos
13.
Foot Ankle Spec ; : 19386400211067865, 2022 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-35048741

RESUMO

INTRODUCTION: The literature largely addresses questions of diagnostic accuracy and therapeutic accuracy. However, the magnitude of the clinical impact of syndesmosis injury is commonly described in intuitive yet qualitative terms. This systematic review aimed to quantify the impact of syndesmosis injury. METHODS: Published clinical outcomes data were used to compute an effect size reflecting the impact of syndesmosis injury. This was done within the clinical contexts of isolated syndesmosis injury and syndesmosis injury with concomitant ankle fracture. Clinical outcomes data included Olerud-Molander (OM) and American Orthopaedic Foot and Ankle Society (AOFAS) scores, visual analog scale for pain, and days missed from sport competition. Parametric data were compared with Student t tests. Effect size was computed using Cohen's d. RESULTS: In ankle fracture patients, syndesmosis injury demonstrated a large effect size for OM (d = 0.96) and AOFAS (d = 0.83) scores. In athletic populations without concomitant ankle fracture, syndesmosis injury demonstrated a large effect size on days missed from competition (d = 2.32). DISCUSSION: These findings confirm the magnitude of the negative impact of syndesmosis injury in athletic populations with isolated injury and in ankle fracture patients. In ankle fracture patients, this large negative effect remains despite surgery. Thus, syndesmosis repair may not fully mitigate the impact of the injury. LEVELS OF EVIDENCE: Level III: Systematic review.

14.
J Shoulder Elbow Surg ; 30(12): 2895-2903, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34293419

RESUMO

BACKGROUND: Although reverse shoulder arthroplasty (RSA) has shown satisfactory outcomes in rotator cuff-deficient shoulders, its performance in shoulders with an intact rotator cuff has not been fully elucidated. Shoulder osteoarthritis can present with alterations in glenoid morphology, which have contributed to inconsistent outcomes in anatomic shoulder replacement. The glenoid component is responsible for a predominance of these arthroplasty complications. Given these glenoid-related difficulties, RSA may provide a more favorable option. We aimed to summarize the current literature on rotator cuff intact osteoarthritis treated with primary RSA and to determine whether morphologic changes in the glenoid led to inferior outcomes. METHODS: A literature search was performed using an inclusion criterion of primary RSA for osteoarthritis with an intact rotator cuff. The Modified Coleman Methodology Score was calculated to analyze reporting quality. Following appropriate exclusions, of the 1002 studies identified by the databases, 13 were selected. RESULTS: Postoperative improvement in weighted means for Constant scores reached statistical significance (P = .02). The mean rate of major complications was 3.8%. A subset of 8 studies was created that detailed the following descriptions of altered glenoid morphology: "static posterior instability," "severe posterior subluxation," "posterior glenoid wear >20°," "significant posterior glenoid bone loss," "biconcave glenoid," "B2 glenoid," and "B/C glenoid." Within this subset, the mean complication rate was 4.7%, with 4 of the 7 studies having a rate ≤ 3%, and improvements in the Constant score (P = .002) and external rotation (P = .02) reached statistical significance. DISCUSSION: RSA as treatment for osteoarthritis with an intact rotator cuff provides optimal outcomes with low complication rates across a short term of follow up. Preoperative considerations for using reverse arthroplasty in the treatment of osteoarthritis with an intact rotator cuff include glenoid retroversion, posterior humeral subluxation, and glenoid bone loss. The attributes of reverse arthroplasty that contribute to favorable outcomes in arthritic shoulders include its semiconstrained design and robust glenoid fixation. Soft-tissue imbalances as a consequence of pathologic glenoid morphology and chronic humeral subluxation can be mitigated with the RSA semiconstrained design. Glenoid bone loss can be effectively managed with RSA's robust glenoid fixation, with and without the use of bone graft. The capability to lateralize the joint center of rotation may be valuable when faced with a medialized glenoid wear pattern. The current findings suggest that reverse arthroplasty can achieve highly favorable outcomes for glenohumeral osteoarthritis with an intact rotator cuff.


Assuntos
Artroplastia do Ombro , Artroplastia de Substituição , Osteoartrite , Articulação do Ombro , Humanos , Osteoartrite/cirurgia , Estudos Retrospectivos , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia
15.
J Foot Ankle Surg ; 60(4): 802-806, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33824076

RESUMO

There is currently no consensus on the importance of bone graft use in ankle arthrodesis. Despite this, bone graft is widely used. We aimed to summarize the available literature on primary open ankle arthrodesis fixated with cannulated screws in order to assess the importance of bone graft in achieving more favorable rates of fusion. PubMed and Embase were queried for articles reporting on primary open ankle arthrodesis fixated with cannulated screws which specified use or non-use of bone graft. Pooled data analysis was performed. Modified Coleman Methodology Scores were calculated to assess reporting quality. Twenty-seven studies met our inclusion criteria and were divided into three groups: no bone graft (NBG), fibular onlay with bone graft (FOBG), and use of bone graft (BG). All three groups had comparable fusion rates of 94.7%, 95.3%, and 95.1% respectively (p = .98). Number needed to treat was 7 and Absolute Risk Reduction was 14.8%. The reviewed literature was largely of moderate quality, with an overall Coleman score of 60.6 and no significance between the 3 groups (p = .93). In conclusion, primary open ankle arthrodesis fixated with cannulated screws generally had favorable fusion rates, and bone graft use did not have a significant effect on union rates. The available literature suggests that bone graft may not be needed in routine tibiotalar arthrodesis in low-risk patients. It may more significantly impact patients who are at high-risk of fusion failure, and dedicated research on this high-risk subset of patients is required.


Assuntos
Articulação do Tornozelo , Tornozelo , Artrodese , Parafusos Ósseos , Transplante Ósseo , Humanos
16.
JSES Rev Rep Tech ; 1(4): 329-334, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37588710

RESUMO

Background: As reverse shoulder arthroplasty (RSA) cases increase, so too will the need to revise subsequent failures. Many of the complications associated with revising anatomic total shoulder and hemiarthroplasty have been adequately addressed by RSA including glenoid bone deficiency, instability, and functional outcomes. However, the risk for complication when revising a failed reverse prosthesis may be more pronounced with increased bone and soft tissue deficiency. The ability for the reversed prosthesis to accommodate these insufficiencies following a prior reversed prosthesis is unclear. Methods: PubMed, Embase, and Google Scholar were queried for articles which fit the inclusion criteria of a reversed prosthesis used to revise a failed primary reverse prosthesis with a minimum follow-up of 12 months and clinical outcome reporting. Results: After exclusions, 9 studies reporting on 242 reverse shoulders with a mean follow-up of 40.29 months were analyzed. The differences between preoperative and postoperative weighted means were not significant for Constant (P = .26), American Shoulder and Elbow Surgeons Shoulder score (P = .61), SSV (P = .57), and visual analog scale for pain (P = .48). Functional improvements in elevation (74°-102°) and external rotation (18°-21°) were consistent with those reported for primary reverse procedures, although differences in preoperative and postoperative measures were not statistically significant. Patient satisfaction was 89% with a major complication rate of 25%. Discussion: The reverse shoulder prosthesis has proven satisfactory in revising hemiarthroplasty and anatomic total shoulder arthroplasty. The current results indicate RSA is also a satisfactory treatment option when revising a prior reverse prosthesis. Inherent to revision shoulder surgery is the obstacle of humeral and glenoid bone loss, an attenuated soft-tissue envelope, and instability. The reverse prosthesis may adequately address these commonly confronted difficulties with its inherent design characteristics. RSA provides a secure glenoid fixation for bone grafting, the ability to increase construct stability with component sizing, and a reliance on the deltoid for function. As our learning about revision of RSA improves, so will our ability to preemptively address potential issues which may lead to decreased complications in these cases. Despite the 25% rate of major complication, patients reported satisfaction of 89% which demonstrates the improvements in function and pain relief that are provided by the reverse prosthesis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA