Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
J Magn Reson Imaging ; 57(6): 1865-1875, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36315000

RESUMO

BACKGROUND: Three-dimensional (3D) multiecho balanced steady-state free precession (ME-bSSFP) has previously been demonstrated in preclinical hyperpolarized (HP) 13 C-MRI in vivo experiments, and it may be suitable for clinical metabolic imaging of prostate cancer (PCa). PURPOSE: To validate a signal simulation framework for the use of sequence parameter optimization. To demonstrate the feasibility of ME-bSSFP for HP 13 C-MRI in patients. To evaluate the metabolism in PCa measured by ME-bSSFP. STUDY TYPE: Retrospective single-center cohort study. PHANTOMS/POPULATION: Phantoms containing aqueous solutions of [1-13 C] lactate (2.3 M) and [13 C] urea (8 M). Eight patients (mean age 67 ± 6 years) with biopsy-confirmed Gleason 3 + 4 (n = 7) and 4 + 3 (n = 1) PCa. FIELD STRENGTH/SEQUENCES: 1 H MRI at 3 T with T2 -weighted turbo spin-echo sequence used for spatial localization and spoiled dual gradient-echo sequence used for B0 -field measurement. ME-bSSFP sequence for 13 C MR spectroscopic imaging with retrospective multipoint IDEAL metabolite separation. ASSESSMENT: The primary endpoint was the analysis of pyruvate-to-lactate conversion in PCa and healthy prostate regions of interest (ROIs) using model-free area under the curve (AUC) ratios and a one-directional kinetic model (kP ). The secondary objectives were to investigate the correlation between simulated and experimental ME-bSSFP metabolite signals for HP 13 C-MRI parameter optimization. STATISTICAL TESTS: Pearson correlation coefficients with 95% confidence intervals and paired t-tests. The level of statistical significance was set at P < 0.05. RESULTS: Strong correlations between simulated and empirical ME-bSSFP signals were found (r > 0.96). Therefore, the simulation framework was used for sequence optimization. Whole prostate metabolic HP 13 C-MRI, observing the conversion of pyruvate into lactate, with a temporal resolution of 6 seconds was demonstrated using ME-bSSFP. Both assessed metrics resulted in significant differences between PCa (mean ± SD) (AUC = 0.33 ± 012, kP  = 0.038 ± 0.014) and healthy (AUC = 0.15 ± 0.10, kP  = 0.011 ± 0.007) ROIs. DATA CONCLUSION: Metabolic HP 13 C-MRI in the prostate using ME-bSSFP allows for differentiation between aggressive PCa and healthy tissue. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1.


Assuntos
Neoplasias da Próstata , Ácido Pirúvico , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Ácido Pirúvico/química , Ácido Pirúvico/metabolismo , Estudos Retrospectivos , Estudos de Coortes , Neoplasias da Próstata/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ácido Láctico
2.
Radiologe ; 62(5): 385-393, 2022 May.
Artigo em Alemão | MEDLINE | ID: mdl-35258684

RESUMO

Over the years the development of field strength in magnetic resonance imaging (MRI) has continued to increase from the low-field systems in the early years (0.2-0.5 T) to 1.5 T to 3 T to 7 T and more. In the last 2 years, there has been a renewed interest in MRI at lower fields, mainly driven by the development of "dry" superconductive magnets. The following article demonstrates that this renewed interest for lower fields is not a déjà vu purely driven by economic needs. The field strength appears to be from yesterday, but the combination with the tremendous improvements and innovations of all relevant components-gradients, radiofrequency system and especially new algorithms including the use of artificial intelligence (AI)-allow the realization of diagnostically adequate MRI without compromise in patient throughput and efficiency. In addition to the lower field, there are also some inherent advantages, e.g., for MRI of the lung and of metallic implants and especially for interventional MRI. It has already been shown that many of the devices used for interventional procedures (catheters, biopsy needles) can be used at lower fields without costly modifications. In addition, low-field MRI also allows the robust use of highly efficient sampling methods like spiral MRI. It is therefore safe to predict that low-field MRI is not only a cost-efficient compromise, but has the potential to open up new fields of application.


Assuntos
Inteligência Artificial , Imageamento por Ressonância Magnética , Algoritmos , Humanos , Imageamento por Ressonância Magnética/métodos , Imãs , Próteses e Implantes
3.
NMR Biomed ; 34(1): e4400, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32869915

RESUMO

MR is a prominent technology to investigate diseases, with millions of clinical procedures performed every year. Metabolic dysfunction is one common aspect associated with many diseases. Thus, understanding and monitoring metabolic changes is essential to develop cures for many illnesses, including for example cancer and neurodegeneration. MR methodologies are especially suited to study endogenous metabolites and processes within an organism in vivo, which has led to many insights about physiological functions. Advancing metabolic MR techniques is therefore key to further understand physiological processes. Here, we introduce an approach based on nuclear spin singlet states to specifically filter metabolic signals and particularly show that singlet-filtered glutamate can be observed distinctly in the hippocampus of a living mouse in vivo. This development opens opportunities to make use of the singlet spin phenomenon in vivo and besides its use as a filter to provide scope for new contrast agents.


Assuntos
Espectroscopia de Ressonância Magnética , Animais , Simulação por Computador , Imageamento por Ressonância Magnética , Masculino , Metaboloma , Camundongos Endogâmicos C57BL
4.
Radiother Oncol ; 150: 128-135, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32544609

RESUMO

BACKGROUND AND PURPOSE: Hypoxia is an essential metabolic marker that determines chemo- and radiation resistance in head-and-neck squamous cell carcinoma (HNSCC) patients. Our exploratory analysis aimed to identify multiparametric MRI (mpMRI) parameters linked to hypoxia that might be used as surrogate for [18F]FMISO-PET in diagnosis and chemoradiation treatment (CRT) of HNSCC. MATERIALS AND METHODS: 21 patients undergoing definitive CRT for HNSCC were prospectively imaged with serial [18F]FMISO-PET and 3 Tesla mpMRI for T1- and T2-weighted and dynamic contrast-enhanced perfusion and diffusion-weighted measurements (ktrans, ve, kep, ADC) in weeks 0, 2 and 5 and FDG-PET in week 0. [18F]FMISO-PET-derived hypoxic subvolumes (HSV) and complementary non-hypoxic subvolumes (nonHSV) were created for tumor and lymph nodes and projected on the mpMRI scans after PET/MRI co-registration. MpMRI and [18F]FMISO-PET parameters within HSVs and nonHSVs were statistically compared. RESULTS: FMISO-PET-based HSVs of the primary tumors on MRI were characterized by lower ADC at all time points (p = 0.012 at baseline; p = 0.015 in week 2) and reduced interstitial space volume fraction ve and perfusion ktrans at baseline (p = 0.006, p = 0.047) compared to nonHSVs. Hypoxic lymph nodes were characterized by significantly lower ADC values at baseline (p = 0.039), but not at later time points and a reduction in ktrans-based perfusion at week 2 (p = 0.018). CONCLUSION: MpMRI parameters differ significantly between hypoxic and non-hypoxic tumor regions, defined on FMISO-PET/CT as gold standard and might represent surrogate markers for tumor hypoxia. These findings suggest that mpMRI may be useful in the future as a surrogate modality for hypoxia imaging in order to personalize CRT.


Assuntos
Neoplasias de Cabeça e Pescoço , Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/terapia , Humanos , Hipóxia , Misonidazol/análogos & derivados , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos
5.
NMR Biomed ; 33(6): e4291, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32154970

RESUMO

The aim of this study was to acquire the transient MRI signal of hyperpolarized tracers and their metabolites efficiently, for which specialized imaging sequences are required. In this work, a multi-echo balanced steady-state free precession (me-bSSFP) sequence with Iterative Decomposition with Echo Asymmetry and Least squares estimation (IDEAL) reconstruction was implemented on a clinical 3 T positron-emission tomography/MRI system for fast 2D and 3D metabolic imaging. Simulations were conducted to obtain signal-efficient sequence protocols for the metabolic imaging of hyperpolarized biomolecules. The sequence was applied in vitro and in vivo for probing the enzymatic exchange of hyperpolarized [1-13 C]pyruvate and [1-13 C]lactate. Chemical shift resolution was achieved using a least-square, iterative chemical species separation algorithm in the reconstruction. In vitro, metabolic conversion rate measurements from me-bSSFP were compared with NMR spectroscopy and free induction decay-chemical shift imaging (FID-CSI). In vivo, a rat MAT-B-III tumor model was imaged with me-bSSFP and FID-CSI. 2D metabolite maps of [1-13 C]pyruvate and [1-13 C]lactate acquired with me-bSSFP showed the same spatial distributions as FID-CSI. The pyruvate-lactate conversion kinetics measured with me-bSSFP and NMR corresponded well. Dynamic 2D metabolite mapping with me-bSSFP enabled the acquisition of up to 420 time frames (scan time: 180-350 ms/frame) before the hyperpolarized [1-13 C]pyruvate was relaxed below noise level. 3D metabolite mapping with a large field of view (180 × 180 × 48 mm3 ) and high spatial resolution (5.6 × 5.6 × 2 mm3 ) was conducted with me-bSSFP in a scan time of 8.2 seconds. It was concluded that Me-bSSFP improves the spatial and temporal resolution for metabolic imaging of hyperpolarized [1-13 C]pyruvate and [1-13 C]lactate compared with either of the FID-CSI or EPSI methods reported at 3 T, providing new possibilities for clinical and preclinical applications.


Assuntos
Ácido Láctico/metabolismo , Espectroscopia de Ressonância Magnética , Ácido Pirúvico/metabolismo , Animais , Espectroscopia de Ressonância Magnética Nuclear de Carbono-13 , Simulação por Computador , Espectroscopia de Prótons por Ressonância Magnética , Ratos Endogâmicos F344 , Processamento de Sinais Assistido por Computador , Fatores de Tempo
6.
Radiat Oncol ; 13(1): 183, 2018 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-30241555

RESUMO

Following the publication of this article [1], the authors noticed that figures 2, 3, 4 and 5 were in the incorrect order and thus had incorrect captions.

7.
Radiat Oncol ; 13(1): 159, 2018 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-30157883

RESUMO

BACKGROUND: To assess the effect of radiochemotherapy (RCT) on proposed tumour hypoxia marker transverse relaxation time (T2*) and to analyse the relation between T2* and 18F-misonidazole PET/CT (FMISO-PET) and 18F-fluorodeoxyglucose PET/CT (FDG-PET). METHODS: Ten patients undergoing definitive RCT for squamous cell head-and-neck cancer (HNSCC) received repeat FMISO- and 3 Tesla T2*-weighted MRI at weeks 0, 2 and 5 during treatment and FDG-PET at baseline. Gross tumour volumes (GTV) of tumour (T), lymph nodes (LN) and hypoxic subvolumes (HSV, based on FMISO-PET) and complementary non-hypoxic subvolumes (nonHSV) were generated. Mean values for T2* and SUVmean FDG were determined. RESULTS: During RCT, marked reduction of tumour hypoxia on FMISO-PET was observed (T, LN), while mean T2* did not change significantly. At baseline, mean T2* values within HSV-T (15 ± 5 ms) were smaller compared to nonHSV-T (18 ± 3 ms; p = 0.051), whereas FDG SUVmean (12 ± 6) was significantly higher for HSV-T (12 ± 6) than for nonHSV-T (6 ± 3; p = 0.026) and higher for HSV-LN (10 ± 4) than for nonHSV-LN (5 ± 2; p ≤ 0.011). Correlation between FMISO PET and FDG PET was higher than between FMSIO PET and T2* (R2 for GTV-T (FMISO/FDG) = 0.81, R2 for GTV-T (FMISO/T2*) = 0.32). CONCLUSIONS: Marked reduction of tumour hypoxia between week 0, 2 and 5 found on FMISO PET was not accompanied by a significant T2*change within GTVs over time. These results suggest a relation between tumour oxygenation status and T2* at baseline, but no simple correlation over time. Therefore, caution is warranted when using T2* as a substitute for FMISO-PET to monitor tumour hypoxia during RCT in HNSCC patients. TRIAL REGISTRATION: DRKS, DRKS00003830 . Registered 23.04.2012.


Assuntos
Quimiorradioterapia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/terapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Carcinoma de Células Escamosas de Cabeça e Pescoço/terapia , Hipóxia Tumoral , Fracionamento da Dose de Radiação , Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/metabolismo , Humanos , Imageamento por Ressonância Magnética/métodos , Misonidazol/análogos & derivados , Consumo de Oxigênio , Estudos Prospectivos , Radiossensibilizantes , Compostos Radiofarmacêuticos , Carcinoma de Células Escamosas de Cabeça e Pescoço/metabolismo , Fatores de Tempo , Carga Tumoral , Hipóxia Tumoral/efeitos dos fármacos , Hipóxia Tumoral/efeitos da radiação
8.
Magn Reson Med ; 77(6): 2153-2166, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27343201

RESUMO

PURPOSE: Achieving higher spatial resolution and improved brain coverage while mitigating in-plane susceptibility artifacts in the assessment of perfusion parameters, such as cerebral blood volume, in echo planar imaging (EPI)-based dynamic susceptibility contrast weighted cerebral perfusion measurements. METHODS: PEAK-EPI, an EPI sequence with interleaved readout trajectories and three different strategies for autocalibration-signal acquisition (inplace, dynamic extra and extra) is presented. Performance of each approach is analyzed in vivo based on flip angle variation induced dynamics, assessing temporal fidelity, temporal SNR and g-factors. All approaches are compared with conventional GRAPPA reconstructions. PEAK-EPI with inplace autocalibration-signal at R = 5 is then compared with the standard clinical EPI protocol in six patients, using two half-dose dynamic susceptibility contrast weighted cerebral perfusion measurements per subject. RESULTS: PEAK-EPI acquisition facilitates a substantial increase of spatial resolution at a higher number of slices per TR and provides improved SNR compared to conventional GRAPPA. High dependency of the resulting reconstruction quality on the type of autocalibration-signal acquisition is observed. PEAK-EPI with inplace autocalibration-signal achieves high temporal fidelity and initial feasibility is shown. CONCLUSION: The obtained high resolution cerebral blood volume maps reveal more detailed information than in corresponding standard EPI measurements and facilitate detailed delineation of tumorous tissue. Magn Reson Med 77:2153-2166, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Determinação do Volume Sanguíneo/métodos , Volume Sanguíneo , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/fisiopatologia , Imagem Ecoplanar/métodos , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Adulto , Algoritmos , Circulação Cerebrovascular , Humanos , Masculino , Reprodutibilidade dos Testes , Tamanho da Amostra , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
9.
MAGMA ; 28(4): 305-14, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25381180

RESUMO

OBJECTIVE: To develop and test in a clinical setting a double-echo segmented echo planar imaging (DEPI) pulse sequence for proton resonance frequency (PRF)-based temperature monitoring that is faster than conventional PRF thermometry pulse sequences and not affected by thermal changes in tissue conductivity. MATERIALS AND METHODS: Four tumor patients underwent between one and nine magnetic resonance (MR)-guided regional hyperthermia treatments. During treatment, the DEPI sequence and a FLASH PRF sequence were run in an interleaved manner to compare the results from both sequences in the same patients and same settings. Temperature maps were calculated based on the phase data of both sequences. Temperature measurements of both techniques were compared using Passing and Bablok regression and the Bland-Altman method. RESULTS: The temperature results from the DEPI and FLASH sequences, on average, do not differ by more than ΔT = 1 °C. DEPI images showed typically more artifacts and approximately a twofold lower signal-to-noise ratio (SNR), but a sufficient temperature precision of 0.5°, which would theoretically allow for a fivefold higher frame rate. CONCLUSION: The results indicate that DEPI can replace slower temperature measurement techniques for PRF-based temperature monitoring during thermal treatments. The higher acquisition speed can be exploited for hot spot localization during regional hyperthermia as well as for temperature monitoring during fast thermal therapies.


Assuntos
Imagem Ecoplanar/métodos , Hipertermia Induzida , Neoplasias/terapia , Termometria/métodos , Idoso , Humanos , Imagem por Ressonância Magnética Intervencionista , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Razão Sinal-Ruído , Resultado do Tratamento
10.
Knee Surg Sports Traumatol Arthrosc ; 22(11): 2655-61, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23716013

RESUMO

PURPOSE: The aim of the present study was to investigate the influence of knee flexion and weight bearing on the Tibial Tuberosity-Trochlear Groove (TTTG) distance. MATERIALS AND METHODS: Magnetic resonance imaging of the knee was carried out in 8 healthy volunteers. An open 0.25 T scanner equipped with a C-shaped permanent tilting magnet allowing examinations in weight-bearing conditions was used for the present investigation. A 3D gradient-echo sequence with axial slice orientation was obtained in a lying and an upright position with the knee straight and at 30° of knee flexion. The medial, central and lateral trochlear heights as well as the TTTG were determined. RESULTS: The mean medial trochlear height was 76.2 ± 4%, the central trochlear height was 72.2 ± 3%, and lateral trochlear height was 82.9 ± 3 %. The mean TTTG distance was 11.6 ± 4.4 mm in lying position at 0° knee flexion and 7.3 ± 2.9 mm (n.s.) at 30° knee flexion. Under weight bearing, the mean TTTG was significantly smaller at both 0° knee flexion 6.3 ± 3.2 mm (p = 0.040) and 30° knee flexion 4.9 ± 3.9 mm (p = 0.006) compared to the lying position with 0° knee flexion. CONCLUSION: Tibial Tuberosity-Trochlear Groove distance depends on both knee flexion angle and weight bearing. The latter only seems to be of relevance in full extension.


Assuntos
Fêmur/anatomia & histologia , Articulação do Joelho/anatomia & histologia , Articulação Patelofemoral/anatomia & histologia , Tíbia/anatomia & histologia , Adulto , Feminino , Fêmur/fisiologia , Humanos , Articulação do Joelho/fisiologia , Imageamento por Ressonância Magnética , Masculino , Articulação Patelofemoral/fisiologia , Amplitude de Movimento Articular , Tíbia/fisiologia , Suporte de Carga
11.
Nat Commun ; 4: 2946, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24336292

RESUMO

Nuclear magnetic resonance spectroscopy and imaging (MRI) play an indispensable role in science and healthcare but use only a tiny fraction of their potential. No more than ≈10 p.p.m. of all ¹H nuclei are effectively detected in a 3-Tesla clinical MRI system. Thus, a vast array of new applications lays dormant, awaiting improved sensitivity. Here we demonstrate the continuous polarization of small molecules in solution to a level that cannot be achieved in a viable magnet. The magnetization does not decay and is effectively reinitialized within seconds after being measured. This effect depends on the long-lived, entangled spin-order of parahydrogen and an exchange reaction in a low magnetic field of 10⁻³ Tesla. We demonstrate the potential of this method by fast MRI and envision the catalysis of new applications such as cancer screening or indeed low-field MRI for routine use and remote application.


Assuntos
Análise Química do Sangue/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Análise Química do Sangue/instrumentação , Catálise , Desenho de Equipamento , Etanol/química , Humanos , Hidrogênio/química , Campos Magnéticos , Magnetismo , Metanol/química , Neoplasias/diagnóstico , Neoplasias/patologia , Piridinas/química , Água/química
12.
Arthroscopy ; 29(2): 317-24, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23273892

RESUMO

PURPOSE: The virtual graft length kinematics of 3 operative techniques were investigated and compared with kinematics of the native coracoclavicular ligaments. METHODS: Thirteen healthy volunteers underwent magnetic resonance imaging (MRI) of the shoulder in 30° increments of abduction (0° to 120°). A 3-dimensional model of the coracoid process (CP) and the clavicle (CL) was created. Footprints of the conoid and the trapezoid ligament were identified. At the CP the potential fixation sites of 3 techniques for reconstruction of the coracoclavicular ligaments (CCLs) were marked. The techniques investigated were (1) horizontal transcoracoid drilling (TH), (2) transclavicular-transcoracoid drilling (TT), and (3) tendon graft passage underneath (PU) the coracoid process. Distances between the clavicular and coracoidal footprints of the coracoclavicular ligaments and to the virtual footprints on the coracoid process were determined for each abduction increment. RESULTS: All methods investigated resulted in a significantly longer virtual trapezoidal graft (P = .001). In PU, in addition, the virtual conoidal graft was significantly longer. TT resulted in a virtual conoidal graft and conoid ligament of equal length. TH showed identical length and distance regulation of the virtual conoidal graft and the conoid ligament, but significant shortening of the virtual trapezoidal graft during abduction. PU showed isometry of the virtual trapezoidal and conoidal grafts. CONCLUSIONS: None of the described procedures for graft fixation restores the kinematics of the native coracoclavicular ligaments. Graft fixation techniques should be chosen with respect to the preoperative type of instability. Persisting isolated vertical instability might benefit from fixation of the conoidal grafts at the native clavicular footprint. For horizontal clavicular instabilities, techniques more preserving of trapezoid ligament kinematics might be favorable. CLINICAL RELEVANCE: The data suggest that the technique of fixation in conoid and trapezoid ligament reconstruction should depend on the underlying type of instability.


Assuntos
Ligamentos Articulares/fisiopatologia , Escápula/fisiologia , Ombro/fisiologia , Adulto , Fenômenos Biomecânicos , Clavícula/fisiologia , Feminino , Humanos , Imageamento Tridimensional , Ligamentos/fisiologia , Imageamento por Ressonância Magnética , Masculino , Escápula/cirurgia , Ombro/cirurgia , Tendões/transplante , Adulto Jovem
13.
J Magn Reson Imaging ; 36(4): 841-6, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22707436

RESUMO

PURPOSE: To evaluate the ability of conventional and ultra-short or zero echo time MRI for imaging of soft and solid dental components in and ex vivo. MATERIALS AND METHODS: Turbo spin echo (TSE), ultra-short echo time (UTE), and zero echo time (ZTE) MRI were performed on extracted (human and equine) teeth and in vivo using whole-body and small-bore MR systems at 3 T, 7T, and 9.4T, respectively. RESULTS: At an isotropic resolution of (600 µm)(3) , strong signal of soft-tissue, e.g., mucosa and nerves with excellent contrast was achieved using TSE at 3T in vivo. No signal, though, was obtained from solid components, e.g., teeth (due to short T(2) ). In contrast, dentin, cementum as well as enamel of extracted teeth were readily depicted using UTE and ZTE at a resolution of ≈ (150 µm)(3) at 7T and 9.4T. In particular, ZTE provided higher signal in enamel. CONCLUSION: As an alternative to X-ray based methods like cone-beam computed tomography (CT) or conventional CT, the presented results demonstrate the potential of ZTE and UTE MRI as a radiation-free imaging modality, delivering contrast of soft and solid components at the same time.


Assuntos
Tecido Conjuntivo/patologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Dente Molar/patologia , Doenças Dentárias/patologia , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Magn Reson Med ; 68(1): 86-97, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22127877

RESUMO

Susceptibility differences among tissues were recently used for highlighting complementary contrast in MRI different from the conventional T(1), T(2), or spin density contrasts. This method, based on the signal phase, previously showed improved image contrast of human or rodent neuroarchitecture in vivo, although direct MR phase imaging of cellular architecture was not available until recently. In this study, we present for the first time the ability of microcoil-based phase MRI to resolve the structure of human glioma neurospheres at significantly improved resolutions (10 × 10 µm(2)) with direct optical image correlation. The manganese chloride property to function as a T(1) contrast agent enabled a closer examination of cell physiology with MRI. Specifically the temporal changes of manganese chloride uptake, retention and release time within and from individual clusters were assessed. The optimal manganese chloride concentration for improved MR signal enhancement was determined while keeping the cellular viability unaffected. The presented results demonstrate the possibilities to reveal structural and functional observation of living glioblastoma human-derived cells. This was achieved through the combination of highly sensitive microcoils, high magnetic field, and methods designed to maximize contrast to noise ratio. The presented approach may provide a powerful multimodal tool that merges structural and functional information of submilimeter biological samples.


Assuntos
Glioma/patologia , Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Manganês , Microscopia Confocal/instrumentação , Esferoides Celulares/patologia , Meios de Contraste , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Miniaturização , Estatística como Assunto
15.
MAGMA ; 24(3): 137-45, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21331647

RESUMO

OBJECT: The aim of this study was to demonstrate the feasibility of MR microimaging on a conventional 9.4 T horizontal animal MRI system using commercial available microcoils in combination with only minor modifications to the system, thereby opening this field to a larger community. MATERIALS AND METHODS: Commercially available RF microcoils designed for high-resolution NMR spectrometers were used in combination with a custom-made probehead. For this purpose, changes within the transmit chain and modifications to the adjustment routines and image acquisition sequences were made, all without requiring expensive hardware. To investigate the extent to which routine operation and high-resolution imaging is possible, the quality of phantom images was analysed. Surface and solenoidal microcoils were characterized with regard to their sensitive volume and signal-to-noise ratio. In addition, the feasibility of using planar microcoils to achieve high-resolution images of living glioma cells labelled with MnCl(2) was investigated. RESULTS: The setup presented in this work allows routine acquisition of high-quality images with high SNR and isotropic resolutions up to 10 µm within an acceptable measurement time. CONCLUSION: This study demonstrates that MR microscopy can be applied at low cost on animal MR imaging systems, which are in widespread use. The successful imaging of living glioma cells indicates that the technique promises to be a useful tool in biomedical research.


Assuntos
Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Espectroscopia de Ressonância Magnética/instrumentação , Microscopia/instrumentação , Animais , Técnicas de Cultura de Células , Desenho de Equipamento , Estudos de Viabilidade , Humanos , Espectroscopia de Ressonância Magnética/métodos , Imagens de Fantasmas
16.
J Angiogenes Res ; 1: 5, 2009 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-19946413

RESUMO

BACKGROUND: Vandetanib is a once-daily oral inhibitor of VEGFR, EGFR and RET signaling pathways. In patients with advanced colorectal cancer and liver metastases, the effect of vandetanib on tumor vasculature was assessed using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). METHODS: Eligible patients received vandetanib 100 or 300 mg/day. DCE-MRI (iAUC(60 )and K(trans)) was used to quantify the primary endpoints of tumor perfusion and vascular permeability. An exploratory assessment of tumor oxygenation was performed using MRI/T2*. All MRI parameters were measured at baseline (twice) and on days 2, 8, 29 and 57. RESULTS: Twenty-two patients received vandetanib (n = 10, 100 mg; n = 12, 300 mg). Baseline measurements of iAUC(60 )and K(trans )were reproducible, with low intrapatient coefficients of variation (11% and 24%, respectively). Estimates of mean % changes from baseline were -3.4% (100 mg) and -4.6% (300 mg) for iAUC(60), and -4.6% (100 mg) and -2.7% (300 mg) for K(trans); these changes were not significantly different between doses. The exploratory T2* measurement showed a significant increase at 300 mg versus 100 mg (P = 0.006). Both doses of vandetanib were generally well tolerated; common toxicities were fatigue, rash and diarrhea (majority CTC grade 1 or 2). The pharmacokinetic profile of vandetanib was similar to that observed previously. There were no RECIST-defined objective responses; five patients experienced stable disease >/=8 weeks. CONCLUSION: In this study in patients with advanced colorectal cancer, vandetanib did not modulate gadolinium uptake in tumor vasculature and tissue measured by the DCE-MRI parameters iAUC(60 )and K(trans). TRIAL REGISTRATION: NCT00496509 (ClinicalTrials.gov); D4200C00050 (AstraZeneca).

17.
Tissue Eng Part C Methods ; 15(3): 455-62, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19348591

RESUMO

OBJECTIVE: To describe dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) as a practical tool for longitudinal assessment of angiogenesis in biomaterials. BACKGROUND: There is a lack of suitable methods for in vivo evaluation of the integration of biomaterials in a clinical setting. In oncology, DCE-MRI is used for the longitudinal monitoring of altered tumor angiogenesis during therapy. Thus, we investigated whether DCE-MRI enables to assess the integration of biomaterials over time. METHODS: The tested material was bovine bone matrix applied in a bilateral sinus lift procedure in combination with concentrated mononuclear cells, including mesenchymal stem cells and autologous thrombin. To assess the development of new blood vessels inside the biomaterial, DCE-MRI was carried out before and 11, 25, 53, and 104 days after surgery. Perfusionparameters were calculated according to the model of Tofts. RESULTS: Analysis of the data revealed increasing parameters for perfusion and blood supply within the transplant over time. It was possible to determine the values for each transplantation site and each point of time separately. CONCLUSION: DCE-MRI is appropriate to repetitively survey angiogenesis and integration of biomaterials in patients. It seems appropriate as a valuable indicator of treatment response or failure, with consecutive adaption of the therapy regime.


Assuntos
Imageamento por Ressonância Magnética/métodos , Transplante de Células-Tronco Mesenquimais/métodos , Microvasos/citologia , Microvasos/crescimento & desenvolvimento , Neovascularização Fisiológica/fisiologia , Idoso , Células Cultivadas , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Resultado do Tratamento
18.
Ann Thorac Surg ; 87(4): 1187-95, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19324149

RESUMO

BACKGROUND: The efficacy of surgical ventricular reconstruction (SVR) for ischemic cardiomyopathy has never been truly quantified. Methods to assess ventricular flow have not been applied to these patients. The objective is to develop a volume-independent technique for assessing the effects of ischemic remodeling and SVR on left ventricular blood flow dynamics. METHODS: Cardiac magnetic resonance images from a healthy volunteer and from a patient before and after SVR were segmented and transformed to generate a grid model of the heart by generating numeric grids and running third-order approximations to achieve 850 grid images per cardiac cycle. These grids formed the skeletal structure of our patient-specific time-dependent ventricular geometry model, the Karlsruhe Heart Model, used for modeling fluid dynamics. We modeled flow, ejection fraction, and blood washout from the ventricle. The model was validated using a silicone ventricle and mock circulation. RESULTS: In the healthy heart and before SVR, ejection fractions were 0.61 and 0.15 and left ventricular volumes were 166 mL and 175 mL, respectively. Surgical ventricular reconstruction decreased left ventricular volume by one fourth. Postoperative ejection fraction was 0.18 in the patient. Post-SVR shape was more spherical than preoperatively and also more spherical than the healthy heart. Ventricular flow patterns in the patient were significantly altered by SVR. However, fluid washout from the ventricle was similar before and after SVR but worse than in the healthy heart. CONCLUSIONS: Fluid dynamic modeling of the heart is possible based on cardiac magnetic resonance imaging data and enables volume-independent quantitative assessment of the surgical procedure. In the future, preoperative modeling for patients with remodeled ventricles may help to achieve optimized post-SVR flow characteristics and potentially outcomes.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiomiopatias/cirurgia , Ventrículos do Coração/cirurgia , Remodelação Ventricular/fisiologia , Adulto , Cardiomiopatias/diagnóstico , Cardiomiopatias/etiologia , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Isquemia Miocárdica/complicações , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia
19.
J Thorac Cardiovasc Surg ; 136(2): 400-7, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18692649

RESUMO

OBJECTIVES: In light of the ongoing discussion about flow-mediated arterial remodeling, it was the aim of this report to demonstrate the detailed assessment of 3-dimensional vascular hemodynamics by high-field magnetic resonance imaging in healthy volunteers and to illustrate its potential in comparison with results in a patient with stenosis. MATERIALS AND METHODS: All examinations consisted of flow-sensitive 4-dimensional magnetic resonance imaging at 3 Tesla. Retrospective blood flow visualization and segmental quantification of wall shear stress and oscillatory shear index were performed. The results from 11 healthy individuals were compared with a 13-year-old patient with aortic stenosis who received a combined protocol with time-resolved 3-dimensional magnetic resonance angiography before and 5 and 9 months after intervention. RESULTS: Evaluation of normal blood flow characteristics demonstrated predominantly right-handed helical flow in the ascending aorta. Vortex formation was observed in 1 of 11 volunteers. Consistently high segmental wall shear stress was found along the circumference of the ascending aorta (average wall shear stress = 0.191 +/- 0.06 N/m(2)) and descending aorta (average 0.191 +/- 0.06 N/m(2)). Compared with volunteers, the patient revealed substantial flow changes proximal and distal to the stenosis. Blood flow alterations in the ascending aorta were also observed associated with changes in velocities and wall shear stress that gradually normalized after intervention. CONCLUSION: Flow-sensitive 4-dimensional magnetic resonance imaging at 3 Tesla can provide deeper insights into hemodynamic alterations in the diagnosis and follow-up of aortic pathologies. These findings indicate the potential of the methodology for the evaluation of effects of localized pathologies on the entire vascular system, which will have to be confirmed in future studies.


Assuntos
Aorta/fisiologia , Velocidade do Fluxo Sanguíneo , Angiografia por Ressonância Magnética , Adolescente , Adulto , Idoso , Aorta/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Meios de Contraste , Feminino , Humanos , Imageamento Tridimensional , Masculino , Resistência ao Cisalhamento
20.
J Cardiovasc Magn Reson ; 10: 30, 2008 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-18538035

RESUMO

Aneurysm formation is a life-threatening complication after operative therapy in coarctation. The identification of patients at risk for the development of such secondary pathologies is of high interest and requires a detailed understanding of the link between vascular malformation and altered hemodynamics. The routine morphometric follow-up by magnetic resonance angiography is a well-established technique. However, the intrinsic sensitivity of magnetic resonance (MR) towards motion offers the possibility to additionally investigate hemodynamic consequences of morphological changes of the aorta. We demonstrate two cases of aneurysm formation 13 and 35 years after coarctation surgery based on a Waldhausen repair with a subclavian patch and a Vosschulte repair with a Dacron patch, respectively. Comprehensive flow visualization by cardiovascular MR (CMR) was performed using a flow-sensitive, 3-dimensional, and 3-directional time-resolved gradient echo sequence at 3T. Subsequent analysis included the calculation of a phase contrast MR angiography and color-coded streamline and particle trace 3D visualization. Additional quantitative evaluation provided regional physiological information on blood flow and derived vessel wall parameters such as wall shear stress and oscillatory shear index. The results highlight the individual 3D blood-flow patterns associated with the different vascular pathologies following repair of aortic coarctation. In addition to known factors predisposing for aneurysm formation after surgical repair of coarctation these findings indicate the importance of flow sensitive CMR to follow up hemodynamic changes with respect to the development of vascular disease.


Assuntos
Aneurisma Aórtico/diagnóstico , Coartação Aórtica/cirurgia , Imageamento por Ressonância Magnética , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Adulto , Aneurisma Aórtico/etiologia , Velocidade do Fluxo Sanguíneo , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA