Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Med Chem ; 67(14): 11841-11867, 2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-38990855

RESUMO

The cannabinoid receptor type 1 (CB1R) is pivotal within the endocannabinoid system regulating various signaling cascades with effects in appetite regulation, pain perception, memory formation, and thermoregulation. Still, understanding of CB1R's cellular signaling, distribution, and expression dynamics is very fragmentary. Real-time visualization of CB1R is crucial for addressing these questions. Selective drug-like CB1R ligands with a defined pharmacological profile were investigated for the construction of CB1R fluorescent probes using a reverse design-approach. A modular design concept with a diethyl glycine-based building block as the centerpiece allowed for the straightforward synthesis of novel probe candidates. Validated by computational docking studies, radioligand binding, and cAMP assay, this systematic approach allowed for the identification of novel pyrrole-based CB1R fluorescent probes. Application in fluorescence-based target-engagement studies and live cell imaging exemplify the great versatility of the tailored CB1R probes for investigating CB1R localization, trafficking, pharmacology, and its pathological implications.


Assuntos
Corantes Fluorescentes , Receptor CB1 de Canabinoide , Corantes Fluorescentes/química , Corantes Fluorescentes/síntese química , Receptor CB1 de Canabinoide/metabolismo , Humanos , Simulação de Acoplamento Molecular , Células HEK293 , Ligantes , Pirróis/química , Pirróis/farmacologia , Pirróis/síntese química , Relação Estrutura-Atividade , AMP Cíclico/metabolismo
2.
Chemistry ; : e202401928, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38842498

RESUMO

Herein, we report the synthesis and sensing characteristics of 4,4'-methoxy-substituted BODIPY fluorescent probes (O-BODIPYs) 3, 4 and 5 equipped with differently sized benzo-crown ethers (cf. Scheme 1, 3 (benzo-15-crown-5), 4 (benzo-18-crown-6) and 5 (benzo-21-crown7)). O-BODIPYs 3, 4 and 5 exhibited in comparison to their known F-BODIPY analogues 3a, 4a and 5a (cf. Scheme 1) an improved solubility in aqueous medium and higher fluorescence quantum yields. Fluorometric study in aqueous solutions of 3, 4 and 5 in the presence of different cations show cation induced fluorescence enhancements (FE). Compared to the benzo-crown ether substituted F-BODIPY analogues 3a, 4a and 5a, we found for the free O-BODIPYs 3, 4 and 5 higher fluorescence quantum yields (φf) but lower cation induced FEs. We show that in aqueous medium the fluorescence quenching process (OFF switching), a photoinduced electron transfer, in O-BODIPYs 3, 4 and 5 is less effective and consequently sensitive and selective ON switching of the fluorescence by cations, too. Albeit these observations the novel benzo-21-crown-7 equipped fluorescent probe 5 exhibits a good fluorometric Ba2+ selectivity and Ba2+ sensitivity in conjunction to their aqueous solubility.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA