Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Neurointervention ; 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38615689

RESUMO

PURPOSE: In this study, we determined whether there were significant differences in procedure time, radiation dose, fluoroscopy time, and total contrast media dose when unruptured wideneck bifurcation aneurysms (WNBAs) were treated with the Woven EndoBridge (WEB) device and stent-assisted coil (SAC) embolization. MATERIALS AND METHODS: The WEB device and SAC embolization (14:17) were used to treat 31 cases of internal carotid artery bifurcation, anterior communicating artery, middle cerebral artery bifurcation, and basilar bifurcation aneurysms between August 2021 and December 2022. The procedure time, radiation dose, fluoroscopy time, and total contrast medium dose between the 2 treatment groups were compared and analyzed. In the WEB device group, the results between operators were compared, and the follow-up radiologic outcomes were investigated. RESULTS: The procedure and fluoroscopy times were significantly shorter in the WEB device group. Radiation and total contrast media dose were also significantly smaller in the WEB device, but there was no significant difference in results between operators. The follow-up radiological outcome showed adequate occlusion in 83.3% (10/12) of cases. CONCLUSION: The WEB device can be used as an alternative treatment method among the available endovascular treatment methods for WNBAs to reduce radiation exposure and the dose of contrast media when used adequately with appropriate indications.

2.
Acta Radiol ; 65(6): 654-662, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38623647

RESUMO

BACKGROUND: Post-contrast T1-Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions (SPACE) is the preferred 3D T1 spin-echo sequence for evaluating brain metastases, regardless of the prolonged scan time. PURPOSE: To evaluate the application of accelerated post-contrast T1-SPACE with iterative denoising (ID) for intracranial enhancing lesions in oncologic patients. MATERIAL AND METHODS: For evaluation of intracranial lesions, 108 patients underwent standard and accelerated T1-SPACE during the same imaging session. Two neuroradiologists evaluated the overall image quality, artifacts, degree of enhancement, mean contrast-to-noise ratiolesion/parenchyma, and number of enhancing lesions for standard and accelerated T1-SPACE without ID. RESULTS: Although there was a significant difference in the overall image quality and mean contrast-to-noise ratiolesion/parenchyma between standard and accelerated T1-SPACE without ID and accelerated SPACE with and without ID, there was no significant difference between standard and accelerated T1-SPACE with ID. Accelerated T1-SPACE showed more artifacts than standard T1-SPACE; however, accelerated T1-SPACE with ID showed significantly fewer artifacts than accelerated T1-SPACE without ID. Accelerated T1-SPACE without ID showed a significantly lower number of enhancing lesions than standard- and accelerated T1-SPACE with ID; however, there was no significant difference between standard and accelerated T1-SPACE with ID, regardless of lesion size. CONCLUSION: Although accelerated T1-SPACE markedly decreased the scan time, it showed lower overall image quality and lesion detectability than the standard T1-SPACE. Application of ID to accelerated T1-SPACE resulted in comparable overall image quality and detection of enhancing lesions in brain parenchyma as standard T1-SPACE. Accelerated T1-SPACE with ID may be a promising replacement for standard T1-SPACE.


Assuntos
Artefatos , Neoplasias Encefálicas , Meios de Contraste , Estudos de Viabilidade , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Humanos , Neoplasias Encefálicas/diagnóstico por imagem , Feminino , Estudos Retrospectivos , Masculino , Pessoa de Meia-Idade , Idoso , Imageamento por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Adulto , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Razão Sinal-Ruído , Idoso de 80 Anos ou mais , Aumento da Imagem/métodos
3.
Curr Med Imaging ; 19(7): 784-787, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36437728

RESUMO

BACKGROUND: Diffuse large B-cell lymphomas are the most common type of non-Hodgkin lymphoma. Because cutaneous lymphomas predominantly originate from the T cells, primary cutaneous diffuse large B-cell lymphomas are considered a rare subtype of extranodal diffuse large B-cell lymphomas that commonly involve the subcutaneous tissues of the trunk and extremities. To date, only a single case of facial primary cutaneous diffuse large B-cell lymphoma has been reported in the literature. CASE REPORT: We present a case of primary cutaneous diffuse large B-cell lymphoma presented with a small painless nodule in the right nasolabial fold that had persisted for 10 days in a 67-year-old man. Ultrasonographic findings of this lesion mimicked the features of a complicated epidermal inclusion cyst. Primary cutaneous diffuse large B-cell lymphoma was confirmed by an excisional biopsy of the mass. CONCLUSION: The diagnosis of primary cutaneous diffuse large B-cell lymphomas presenting as "oops lesions" in daily clinical practice can be challenging due to their rarity and nonspecific clinical and radiological findings. Therefore, clinical suspicion and awareness are critical for the accurate diagnosis and management of patients with palpable soft tissue masses in the head and neck region.


Assuntos
Linfoma Difuso de Grandes Células B , Neoplasias Cutâneas , Masculino , Humanos , Lactente , Sulco Nasogeniano/diagnóstico por imagem , Sulco Nasogeniano/patologia , Linfoma Difuso de Grandes Células B/diagnóstico por imagem , Neoplasias Cutâneas/diagnóstico por imagem
4.
Acta Radiol ; 64(7): 2245-2252, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36575592

RESUMO

BACKGROUND: Computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) is highly affected by respiratory motion; however, respiratory motion of target nodule during the PTNB and its effect on CT-guided lung biopsy have not been studied. PURPOSE: To investigate the effect of the respiratory motion of pulmonary nodules on CT-guided PTNB. MATERIAL AND METHODS: We retrospectively reviewed the procedural CT scans of 426 pulmonary nodules that underwent PTNB during quiet breathing. Maximal and average respiratory motions were measured using the difference of table position of the targeted nodule between multiple procedural scans. Diagnostic performance, complications, and technical factors of PTNB in nodules with large motion (maximal motion >1 cm) were compared with those in nodules with small motion (≤1 cm). RESULTS: The mean maximal and average respiratory motions between tidal volume breathing were 5.4 ± 4.4 and 2.7 ± 2.6 mm, respectively. Sensitivity and accuracy were 93.1% and 96.1% in nodules with large motion, compared with 94.7% and 95.9% in nodules with small motion, respectively. Respiratory targeting (P < 0.001), needle modulation (P < 0.001), motion artifact of target (P < 0.001), target disappearance from scans (P < 0.001), and number of performed CT scans (P < 0.001) were significantly higher in the large motion group, with no significant difference in radiation dose and complications between the groups. CONCLUSION: The respiratory motion of pulmonary nodules during CT-guided PTNB may cause technical difficulties but does not affect diagnostic performance nor complications associated with PTNB.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Humanos , Neoplasias Pulmonares/patologia , Estudos Retrospectivos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Biópsia por Agulha/métodos , Biópsia Guiada por Imagem/métodos , Radiografia Intervencionista/métodos
5.
Taehan Yongsang Uihakhoe Chi ; 83(3): 719-723, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-36238521

RESUMO

Rosai-Dorfman Disease (RDD) is a rare lymphoproliferative disease, and the occurrence of isolated intracranial RDD is extremely rare. Most cases of intracranial RDDs present as dural masses showing homogenous enhancement on MRI, which makes it difficult to differentiate these masses from meningiomas before surgery unless massive cervical lymphadenopathy is observed. We herein report a rare case of isolated intracranial RDD in a 65-year-old male. Brain MRI revealed a well-defined enhancing mass-like lesion involving the right frontal convexity and subtle diffusion restriction. However, only a subtle blush was observed on the preoperative cerebral angiogram. Although instances of isolated intracranial RDD are rare, it should be considered as a potential differential diagnosis when a dural mass with hypovascularity is visualized on the cerebral angiogram.

6.
J Comput Assist Tomogr ; 46(2): 294-299, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35297585

RESUMO

OBJECTIVE: The aim of the study was to retrospectively evaluate the safety and accuracy of computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) of lung lesions during quiet breathing. METHODS: We investigated the diagnostic performance and complication rate of 585 procedures in 563 patients (357 men; mean age, 67.7 years), who underwent CT-guided PTNBs during quiet breathing, aided by a respiratory targeting technique from May 2017 to July 2019. Differences between the cases with and without respiratory targeting were analyzed. Logistic regression analyses were performed to examine the development of pneumothorax and hemoptysis. RESULTS: Percutaneous transthoracic needle biopsy samples were successfully obtained in 574 of 585 procedures (98.1%). Final diagnoses included: 410 malignant cases, 119 benign cases, and 45 indeterminate cases. The sensitivity, specificity, and accuracy of diagnosis were 94.4%, 100%, and 95.7%, respectively. Use of respiratory targeting was associated with younger age (P = 0.004), smaller lesion size (P < 0.001), peripheral location (P = 0.003), shorter distance from the diaphragm (P < 0.001), lower lobe location (P < 0.001), prone position (P = 0.004), and visible motion artifact (P < 0.001). Pneumothorax and hemoptysis rates were 22.9% and 7.9%, respectively. Upon multivariate analysis, emphysema (P = 0.002) was the only independent risk factor for pneumothorax, whereas distance from the pleura greater than 2 cm (P < 0.001), tissue sampling 3 times or more (P = 0.003), and a less experienced operator (P < 0.001) were risk factors for hemoptysis. CONCLUSIONS: Computed tomography-guided PTNB during quiet breathing with respiratory targeting yielded high diagnostic performance with a slightly higher rate of complications. Free-breathing PTNB can be applied in clinical practice, based on lesion location and risk factors for complications.


Assuntos
Biópsia Guiada por Imagem , Neoplasias Pulmonares , Radiografia Intervencionista , Idoso , Humanos , Biópsia Guiada por Imagem/métodos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
7.
Taehan Yongsang Uihakhoe Chi ; 81(2): 428-435, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36237394

RESUMO

Herein, we report a case of synchronous bilateral triple negative invasive ductal breast carcinoma in a patient with discrepant pathologic response to neoadjuvant chemotherapy. Right and left breast cancer stages at the initial diagnosis were T1cN0M0 and T4dN3aM0, respectively. The patient was identified as a BRCA1 mutation carrier and treated with four cycles of adriamycin and cyclophosphamide, followed by four cycles of docetaxel. Bilateral breast cancer stages decreased with the first regimen. However, the bilateral breast cancers showed discrepant responses to chemotherapy with docetaxel. The right breast cancer showed a continuous tumor volume reduction while the left breast cancer showed marked progression. Finally, the tumor size was 0.3 cm and 12 cm in the right and left mastectomy specimens, respectively. As bilateral breast cancers of the same subtype may show discrepant responses to neoadjuvant chemotherapy, close monitoring and follow-up imaging are required to avoid delayed surgery.

9.
Asia Pac J Clin Oncol ; 16(2): e131-e138, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31111595

RESUMO

BACKGROUND: The purpose of our study is to evaluate risk factors for the development of pulmonary fibrosis in the baseline computed tomography (CT) during the course of chemotherapy-induced pneumonitis (CIP). METHODS: We retrospectively identified 80 cases of CIP by clinical, radiological, and pathological findings. When fibrosis developed during the follow-up, the extent of pulmonary fibrosis was evaluated at final follow-up CT in terms of a 5% volumetric score for six zones. Univariate and multivariate analyses were performed to identify the clinical and radiological risk factors for the development of fibrosis and severe fibrosis over 11% in extent. RESULTS: Fibrosis occurred in 26 of the 80 total patients (32.5%) during a mean 5.6 months of follow up. Risk factors for developing fibrosis were revealed as preexisting interstitial lung disease (ILD) and moderate to severe emphysema in multivariate analysis (OR = 10.12, 95% CI = 2.35-43.66, and OR = 12.85, 95% CI = 2.81-58.82, respectively). Risk factors for developing severe fibrosis over 11% in extent were revealed as a moderate to severe emphysema (OR = 5.78, 95% CI = 1.07-31.26) in multivariate analysis. CONCLUSIONS: Moderate to severe emphysema as well as preexisting ILD visible on baseline CT are risk factors for developing pulmonary fibrosis in the course of CIP. Thin-section CT may be helpful to predict the risk of pulmonary fibrosis before administering chemotherapy.


Assuntos
Quimioterapia de Indução/efeitos adversos , Pneumonia/induzido quimicamente , Fibrose Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pneumonia/patologia , Fibrose Pulmonar/patologia , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
10.
Artigo em Inglês | MEDLINE | ID: mdl-31781047

RESUMO

Background: Benign thyroid follicular tumors without histological evidence of carcinoma can metastasize. However, the pathogenesis of metastasis remains unclear. Here, the new proposed terminology, "non-invasive follicular thyroid neoplasm with papillary-like nuclear features" should be considered. We present a case of an encapsulated type of follicular variant of papillary thyroid carcinoma (FVPTC) that exhibited distant lung and brain metastases and was initially diagnosed as follicular adenoma. Case Report: In December 2006, a 64-year-old woman underwent ultrasonography-guided fine-needle aspiration of the right thyroid nodule at our hospital because of a palpable right neck mass. Right lobectomy was performed, and a follicular adenoma was diagnosed. In October 2015, she visited our hospital owing to dry cough and mild dyspnea and underwent computed tomography-guided transthoracic core needle biopsy for the lung nodule owing to probably multiple lung metastasis on chest X-ray and computed tomography. Based on retrospective analysis of the primary thyroid tumor and lung nodule specimen, an encapsulated follicular variant of papillary thyroid carcinoma with lung metastasis was confirmed. Conclusion: We report a case of an encapsulated follicular variant of papillary thyroid carcinoma with unexpected metastasis to the lung 9 years after thyroid surgery in a patient who was initially diagnosed as follicular adenoma. A careful close follow-up with re-examination of the histopathology specimen may be needed in patients who were diagnosed with benign thyroid follicular tumors.

11.
Sci Rep ; 9(1): 7027, 2019 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-31065031

RESUMO

In ultrasound (US)-guided fine-needle aspiration (FNA) of solid thyroid nodules (STN) using liquid-based cytology (LBC), the most appropriate needle size for LBC remains unclear. This study compared the cytological adequacy and complications associated with using 23- and 25-gauge needles in US-guided FNA of STNs using LBC. US-guided FNA was performed in consecutive patients by one radiologist to diagnose STNs ≥ 5 mm in the largest diameter. The one-sampling technique through a single needle puncture and multiple to-and-fro needle motions was used in each patient. The 23- and 25-guage needles were used consecutively each day. After FNA, the pain and complications experienced by each patient were investigated by a nurse, who was blinded to the information of needle gauge used. A cytopathologist retrospectively analyzed the cytological adequacy and cellularity of the cases. Of the 99 STNs, eight (8.1%) exhibited inadequate cytology (4 each with 23- and 25-gauge needles). The rate of cytological adequacy was not statistically different between the groups (p = 0.631). The mean pain scale values with 23- and 25-gauge needles were 2.1 ± 1.3 and 1.6 ± 1.3, respectively (p = 0.135). There were no significant complications in either group. In conclusion, both 23- and 25-gauge needles are useful in LBC because cytological adequacy and complications were not statistically different with both sizes of the needles.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Biópsia Líquida/instrumentação , Dor/diagnóstico , Nódulo da Glândula Tireoide/diagnóstico , Adulto , Idoso , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/efeitos adversos , Feminino , Humanos , Biópsia Líquida/efeitos adversos , Masculino , Pessoa de Meia-Idade , Dor/etiologia , Medição da Dor , Estudos Prospectivos , Estudos Retrospectivos , Nódulo da Glândula Tireoide/patologia
12.
Child Neurol Open ; 6: 2329048X19826288, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30783608

RESUMO

Acute encephalopathy with biphasic seizures and late reduced diffusion is a subtype of acute encephalopathy described in a cohort of Japanese children. Few cases have been reported in countries other than Japan. It is characterized clinically by biphasic seizures and late reduced subcortical diffusion on magnetic resonance imaging (MRI). We report the case of a 3-year-old Korean girl with acute encephalopathy with biphasic seizures and late reduced diffusion who presented with status epilepticus associated with fever and pneumonia. Human adenovirus was detected from a respiratory specimen using multiplex real-time reverse transcriptase polymerase chain reaction. After 5 days, she developed a second cluster of seizures followed by altered consciousness, aphasia, stereotypic movement, and developmental regression. Her brain MRI showed symmetrical and extensive restricted diffusion in the subcortical white matter, which finally resulted in global brain atrophy, consistent with acute encephalopathy with biphasic seizures and late reduced diffusion. Here, we report a case of acute encephalopathy with biphasic seizures and late reduced diffusion associated with preceding adenoviral pneumonia.

13.
Neuroradiology ; 61(7): 747-755, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30684114

RESUMO

PURPOSE: To evaluate the diagnostic performance, image quality, artifacts, and radiation doses of virtual non-contrast (VNC) images, relative to true non-contrast (TNC) images, in patients with surgically clipped aneurysms. METHODS: Seventy-six patients who underwent unenhanced computed tomography (CT) and dual-energy (DE)-CT angiography after surgical clipping of 85 intracranial aneurysms were included in the study. Diagnostic performances of VNC and TNC images were compared with respect to sensitivity, specificity, and positive and negative predictive values. The results of quantitative and qualitative analyses were compared between VNC and TNC images. Radiation doses were also compared between VNC and TNC images. RESULTS: Diagnostic performance of VNC images was lower than that of TNC images; however, addition of contrast-enhanced images improved diagnostic performance. Image noise and mean attenuation of VNC images were significantly higher than those of TNC images in the centrum semiovale, cerebellum, and pons. The quality of VNC images was excellent or sufficient (85.5% for observer 1, 85.5% for observer 2), and complete acceptance of VNC images was achieved in 64.5% for observer 1 and in 71.0% for observer 2; however, the addition of contrast-enhanced images increased the level of acceptance (92.0% for observer 1, 90.9% for observer 2). Clip artifacts were significantly lower in VNC images than in TNC images. CT dose index, dose-length product, and effective dose were significantly lower without TNC images. CONCLUSION: VNC images showed lower diagnostic performance and image quality, and higher image noise than TNC images; however, VNC images could reduce clip artifacts and radiation doses.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Meios de Contraste , Feminino , Humanos , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
14.
Medicina (Kaunas) ; 56(1)2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31906183

RESUMO

Background and Objectives: To investigate the diagnostic performance of F-18 fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) and subsequent ultrasonography (US) for determining cervical nodal metastasis in oncology patients. Materials and Methods: Fifty-nine cervical lymph nodes (LNs) initially detected by PET/CT with subsequent neck US were included in this retrospective study. All LNs were subjected to US-guided fine-needle aspiration or core needle biopsy. The maximum standardized uptake value (SUVmax) and sonographic features were assessed. Results: Forty-three of 59 cervical LNs detected by PET/CT were malignant. PET/CT alone showed a highest diagnostic value for metastatic LNs with 81.4% sensitivity, 68.8% specificity, and 78% accuracy when SUVmax ≥5.8 was applied as an optimal cut-off value. Combined PET/CT and subsequent US diagnoses for determining nodal metastasis showed the following diagnostic performance: 81.4% sensitivity, 87.5% specificity, and 83.1% accuracy. There was a significant difference in the diagnostic performance between the two diagnostic imaging approaches (p = 0.006). Conclusions: Combined diagnosis using subsequent US showed a significantly higher diagnostic performance for determining nodal metastasis in the neck. Therefore, we believe that our proposed diagnostic strategy using subsequent US can be helpful in evaluating cervical LNs on PET/CT. Moreover, our results clarify the need for US-guided tissue sampling in oncology patients.


Assuntos
Linfonodos/diagnóstico por imagem , Metástase Linfática/diagnóstico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Linfonodos/fisiopatologia , Metástase Linfática/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Pescoço/diagnóstico por imagem , Pescoço/fisiopatologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Retrospectivos , Ultrassonografia/métodos
15.
PLoS One ; 13(8): e0202687, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30118506

RESUMO

This study investigated the role of BRAF mutation analysis in thyroid fine-needle aspiration (FNA) samples compared to ultrasonographic and cytological diagnoses. A total 316 patients underwent ultrasonography (US)-guided FNA with BRAFV600E mutation analysis to diagnose thyroid nodules. One hundred sixteen patients with insufficient US images (n = 6), follow-up loss (n = 43), or unknown final diagnosis (n = 67) were excluded from the study. Comparisons between US diagnoses, cytological diagnoses, and BRAF mutation analysis were performed. Of 200 thyroid nodules, there was US diagnosis with 1 false negative and 11 false positive cases, cytological diagnosis with 10 false negative and 2 false positive cases, and BRAFV600E mutation analysis with 19 false negative and 2 false positive cases. The sensitivity, specificity, positive and negative predictive values, and accuracy of BRAFV600E mutation analysis were 83.2%, 98.1%, 97.5%, 86.6%, and 91%, respectively. Of the 18 nodules with Bethesda category III, 9 were true positive, 6 were true negative, 3 was a false negative, and none were false positive on BRAF mutation analysis. In conclusion, we recommend that BRAFV600E mutation analysis only be performed for evaluating thyroid nodules with Bethesda category III, regardless of US diagnosis.


Assuntos
Proteínas Proto-Oncogênicas B-raf/genética , Nódulo da Glândula Tireoide/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Análise Mutacional de DNA , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Reações Falso-Negativas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Polimorfismo de Nucleotídeo Único , Estudos Retrospectivos , Nódulo da Glândula Tireoide/genética , Nódulo da Glândula Tireoide/patologia , Ultrassonografia , Adulto Jovem
16.
Artigo em Inglês | MEDLINE | ID: mdl-30072958

RESUMO

Background: The objective of this study was to compare the postoperative neck pain and discomfort, swallowing difficulty, and voice change after conventional open thyroidectomy (COT), endoscopic thyroidectomy (ET), or robotic thyroidectomy (RT) performed by a single surgeon. Methods: From January 2013 to December 2017, 254 patients underwent COT, ET, or RT performed by a single surgeon and completed a postoperative symptom survey conducted in the outpatient clinic by three nurses. The survey collected information on postoperative neck pain and discomfort, swallowing difficulty, and voice change. Results: Of the 254 patients, 169 underwent COT, 32 underwent ET, and 53 underwent RT. The mean age in the COT, ET, and RT groups was 50.1, 44.5, and 41.6 years, respectively. The mean interval between thyroidectomy and survey in the COT, ET, and RT groups was 42.7, 50.2, and 9.2 months, respectively. Postoperative neck pain was significantly higher in the ET and RT groups than in the COT group (p = 0.026). The average neck impairment index score in the RT group was significantly higher than that in the COT group (p < 0.001). There were no significant differences in pain scale scores, swallowing difficulty, swallowing impairment index, voice change, and voice hand index among the three groups. Conclusions: There were no significant differences in postoperative voice change or swallowing difficulty among the COT, ET, and RT groups, whereas neck pain and discomfort were more common after ET and RT than COT.

17.
Artigo em Inglês | MEDLINE | ID: mdl-29867759

RESUMO

BACKGROUND: The ultrasonographic characteristics and difference for various subtypes of papillary thyroid carcinoma (PTC) are still unclear. The aim of this study was to compare the ultrasonographic features of PTC according to its subtype in patients undergoing thyroid surgery. METHODS: In total, 140 patients who underwent preoperative thyroid ultrasonography (US) and thyroid surgery between January 2016 and December 2016 were included. The ultrasonographic features and the Korean Thyroid Imaging Reporting and Data System (K-TIRADS) category of each thyroid nodule were retrospectively evaluated by a single radiologist, and differences in ultrasonographic features according to the PTC subtype were assessed. RESULTS: According to histopathological analyses, there were 97 classic PTCs (62.2%), 34 follicular variants (21.8%), 5 tall cell variants (3.2%), 2 oncocytic variants (1.3%), 1 Warthin-like variant (0.6%), and 1 diffuse sclerosing variant (0.6%). Most PTCs were classified under K-TIRADS category 5. Among the ultrasonographic features, the nodule margin and the presence of calcification were significantly different among the PTC subtypes. A spiculated/microlobulated margin was the most common type of margin, regardless of the PTC subtype. In particular, all tall cell variants exhibited a spiculated/microlobulated margin. The classic PTC group exhibited the highest prevalence of intranodular calcification, with microcalcification being the most common. The prevalence of multiplicity and nodal metastasis was high in the tall cell variant group. CONCLUSION: The majority of PTCs in the present study belonged to K-TIRADS category 5, regardless of the subtype. Our findings suggest that ultrasonographic features are not useful for distinguishing PTC subtypes.

18.
BMC Med Imaging ; 18(1): 12, 2018 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-29764382

RESUMO

BACKGROUND: This study aimed to assess the appropriate number of sessions and interval of routine follow-up ultrasonography (US) in patients who underwent total thyroidectomy for papillary thyroid carcinoma (PTC). METHODS: Between January 2008 and December 2009, 569 patients underwent total thyroidectomy for PTC. Of the 569 patients, 44 were excluded from the study because of no US follow-up data for the neck (n = 43) or owing to indeterminate tumor recurrence/persistence (n = 1). The follow-up US for all the patients was performed by a single radiologist. Based on the cytohistopathological results, tumor recurrence/persistence was determined. RESULTS: In the 525 patients, the mean interval to the last follow-up US was 54.7 months, and the mean number of follow-up US sessions was 4.4. Of the 525 patients, 31 (5.9%) showed nodal (n = 30) and non-nodal (n = 1) tumor recurrence/persistence. Patient age and N stage were independently associated with tumor recurrence/persistence. Among patients showing tumor recurrence/persistence after total thyroidectomy, the time at first detection of suspicious US findings on follow-up US was ≤8 months in 2 patients, between 10 and 23 months in 21, and ≥ 25 months in 8. In a receiver operating characteristic curve analysis, the number of sessions and interval of the provided follow-up US were inappropriate for the detection of tumor recurrence/persistence. CONCLUSIONS: For the detection of tumor recurrence/persistence after total thyroidectomy in PTC patients, routine US follow-up with a 1- or 2-year interval may be excessive.


Assuntos
Recidiva Local de Neoplasia/diagnóstico por imagem , Câncer Papilífero da Tireoide/diagnóstico por imagem , Câncer Papilífero da Tireoide/cirurgia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Testes Diagnósticos de Rotina , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/epidemiologia , Curva ROC , Câncer Papilífero da Tireoide/epidemiologia , Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/cirurgia , Neoplasias da Glândula Tireoide/epidemiologia , Tireoidectomia , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia , Adulto Jovem
19.
Artigo em Inglês | MEDLINE | ID: mdl-29593648

RESUMO

BACKGROUND: No previous study has employed the frequency and interval of follow-up ultrasonography (US) during the first 10 years after total thyroidectomy in patients with papillary thyroid carcinoma (PTC). The aim of this study was to determine the appropriate frequency and interval of follow-up US during the first 10 years in patients who have undergone total thyroidectomy for PTC. METHODS: Two hundred seventy-two patients underwent total thyroidectomy for PTC at our institution from January 2006 to December 2007. Nineteen patients were excluded because of lack of US follow-up data for the neck. Follow-up US was performed by one of two radiologists in all patients. Tumor recurrence/persistence was confirmed by histopathology. RESULTS: The mean interval between surgery and the final follow-up US examination was 79.0 months, and the mean number of follow-up US sessions was 5.9 in the 253 evaluable patients. Eleven patients (4.3%) developed tumor recurrence/persistence, which was detected on follow-up US within 5 years after total thyroidectomy in all cases. T and N stages were independently associated with tumor recurrence/persistence. The interval between surgery and first suspicion of tumor recurrence/persistence on follow-up US was ≤12 months in six patients and 20, 35, 41, 53, and 60 months in the remaining five patients. CONCLUSION: For detection of tumor recurrence/persistence after total thyroidectomy in patients with PTC, one or two sessions of follow-up US during the first 2 years, depending on T and N stages and one session of follow-up US in every second year during the following 8 years may be appropriate.

20.
J Comput Assist Tomogr ; 41(6): 937-940, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28448414

RESUMO

OBJECTIVE: No previous studies have investigated thyroid calcification on computed tomography (CT) quantitatively by using Hounsfield unit (HU) values. This study aimed to analyze quantitative HU values of thyroid calcification on preoperative neck CT and to assess the characteristics of benign and malignant calcified thyroid nodules (CTNs). MATERIALS AND METHODS: Two hundred twenty patients who underwent neck CT before thyroid surgery from January 2015 to June 2016 were included. On soft-tissue window CT images, CTNs with calcified components of 3 mm or larger in minimum diameter were included in this study. The HU values and types of CTNs were determined and analyzed. RESULTS: Of 61 CTNs in 49 patients, there were 42 malignant nodules and 19 benign nodules. The mean largest diameter of the calcified component was 5.3 (2.5) mm (range, 3.1-17.1 mm). A statistically significant difference was observed in the HU values of calcified portions between benign and malignant CTNs, whereas there was no significant difference in patient age or sex or in the size, location, or type of each CTN. Of the 8 CTNs with pure calcification, 3 exhibited a honeycomb pattern on bone window CT images, and these 3 CTNs were all diagnosed as papillary thyroid carcinoma on histopathological examination. CONCLUSIONS: Hounsfield unit values of CTNs may be helpful for differentiating malignancy from benignity.


Assuntos
Calcinose/diagnóstico por imagem , Doenças da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Calcinose/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Doenças da Glândula Tireoide/complicações , Nódulo da Glândula Tireoide/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA