Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 10(4)2021 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-33673247

RESUMO

BACKGROUND AND AIM: Recent randomized data comparing percutaneous mitral valve repair (PMVR) versus optimal medical treatment in patients with functional MR (FMR) seemed to highlight the importance of the learning curve not only for procedural outcomes but also for patient selection. The aim of the study was to compare a contemporary series of patients undergoing PMVR using a second-generation Mitraclip device (Mitraclip NT) with previous cohorts treated with a first-generation system. METHODS: This multicenter study collected individual data from 18 centers between 2012 and 2017. The cohort was divided into three groups according to the use of the first-generation Mitraclip during the first (control-1) or second half (control-2) or the Mitraclip NT system. RESULTS: A total of 545 consecutive patients were included in the study. Among all, 182 (33.3%), 183 (33.3%), and 180 (33.3%) patients underwent mitral repair in the control-1, control-2, and NT cohorts, respectively. Procedural success was achieved in 93.3% of patients without differences between groups. Major adverse events did not statistically differ among groups, but there was a higher rate of pericardial effusion in the control-1 group (4.3%, 0.6%, and 2.6%, respectively; p = 0.025). The composite endpoint of death, surgery, and admission for congestive heart failure (CHF) at 12 months was lower in the NT group (23.5% in control-1, 22.5% in control-2, and 8.3% in the NT group; p = 0.032). CONCLUSIONS: The present paper shows that contemporary clinical outcomes of patients undergoing PMVR with the Mitraclip system have improved over time.

3.
J Invasive Cardiol ; 20(3): E67-70, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18316834

RESUMO

A 2.5 x 32 mm Taxus Libert e stent was deployed at high pressure in the proximal right coronary artery (RCA) of a 71-year-old male patient, but the distal part of the lesion remained uncovered. A second stent (Driver 2.5 x 12 mm) could not be advanced through the first one and was withdrawn. The pullback traction resulted in dislodgement of the stent from its delivery balloon. Fluoroscopic examination suggested that the missing stent had traveled to the ascending aorta. Transesophageal echocardiography disclosed a dense, linear, mobile structure in the ascending aorta arising from the right coronary ostium. A 64-multislice computed tomographic scan revealed that both stents were entangled, with the first stent (Taxus 32 mm) elongated (approximately 90 mm in length), and the second one (Driver 12 mm) attached to the tail of the Taxus stent in the aorta. Stent retrieval was performed with a 15 mm snare loop catheter through a 7 Fr femoral sheath. Examination of the retrieved material revealed elongation of the Taxus stent entangled with the Driver stent. This case illustrates the potential for serious complications derived from stent entanglement, even with modern stent platforms, and how integrating noninvasive imaging modalities can provide crucial information regarding the cause of the complication and its solution.


Assuntos
Oclusão Coronária/etiologia , Vasos Coronários/cirurgia , Falha de Prótese , Stents/efeitos adversos , Procedimentos Cirúrgicos Vasculares/métodos , Síndrome Coronariana Aguda/terapia , Idoso , Angioplastia Coronária com Balão , Oclusão Coronária/diagnóstico por imagem , Ecocardiografia Transesofagiana , Humanos , Masculino , Tomografia Computadorizada Espiral
4.
Eur Heart J ; 29(10): 1296-306, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-17989075

RESUMO

AIMS: The aim of the study was to validate a novel formula for aortic area, based on the principle of continuity equation (CE), that substitutes Doppler-derived stroke volume (SV) by SV directly measured with real-time three-dimensional (RT3D) echo and semi-automated border detection. RT3D has proved outstanding accuracy for left ventricular volume calculation. So far, however, neither this potential has been applied to haemodynamic assessment, nor RT3D has succeeded in the evaluation of aortic valve disease. METHODS AND RESULTS: Aortic area was measured in 41 patients with aortic stenosis using Gorlin's equation, Hakki's formula, Doppler CE, two-dimensional Simpson's volumetric method, and by the novel RT3D method. RT3D has the best linear association and absolute agreement with Gorlin of all non-invasive methods r = 0.902, intraclass correlation coefficient (ICC) = 0.846, better than CE (r = 0.646, ICC = 0.626) and two-dimensional volumetric method (r = 0.627, ICC = 0.378). Linear and Passing-Bablok regression show that RT3D fits better to Gorlin (r(2) = 0.814) than CE (r(2) = 0.417) and two-dimensional method (r(2) = 0.393). Its accuracy is comparable to Hakki's formula, routinely employed in catheter laboratories. Inter- and intraobserver agreements (ICC) were, respectively, 0.732 and 0.985, better than CE (0.662, 0.857). RT3D also grades most efficiently the severity of aortic stenosis as mild, moderate, or severe (weighted kappa = 0.932). RT3D underestimates aortic area (95% CI 0.084-0.193). ROC curves, however, show that the optimal cutoff point to consider aortic stenosis severity remains close to 1 cm(2) (1.06 cm(2)). CONCLUSIONS: RT3D is more accurate than CE and than two-dimensional volumetric methods to calculate area and to grade the severity of aortic stenosis. Area obtained by three-dimensional echo is slightly underestimated, but its range is clinically negligible.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Idoso , Ecocardiografia Tridimensional/normas , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Curva ROC , Sensibilidade e Especificidade
5.
Rev Esp Cardiol ; 60 Suppl 1: 19-32, 2007 Feb.
Artigo em Espanhol | MEDLINE | ID: mdl-17352853

RESUMO

The range of applications of percutaneous coronary intervention (PCI) continues to expand and a growing number of patients are being treated, including those with extensive cardiovascular disease, more serious comorbid conditions, and more complex lesions. Even so, the success rate is high, serious complications are rare in stable patients, and the restenosis rate has been dramatically reduced by drug-eluting stents. Nevertheless, percutaneous techniques still have major limitations restricting their use in some type of lesions, such as bifurcations and total occlusions, and their role in relation to surgical revascularization has not yet been well defined in the treatment of the left main coronary artery or multivessel disease. The development of novel types of coated stent with better mechanical characteristics and a lower risk of occlusion will further expand the ambit of PCI. The role of PCI in the management of acute coronary syndromes is already well defined, and has increased the preference for an invasive rather than a conservative approach in high-risk patients without ST elevation and the preference for primary angioplasty rather than thrombolysis in those with ST elevation. The development and implementation of integrated coronary syndrome treatment networks will enable human and material resources to be used efficiently, and will guarantee rapid access to high-quality PCI for those who need it. The potential usefulness of combining cellular therapy with interventional procedures in the treatment of acute myocardial infarction has still to be determined. At present, there is extensive research into noncoronary interventions, which, in the not too distant future, could provide percutaneous treatment for the many elderly patients with severe aortic stenosis who are not currently eligible for surgery.


Assuntos
Angioplastia Coronária com Balão , Isquemia Miocárdica/terapia , Doença Aguda , Angina Instável/terapia , Terapia Combinada , Doença das Coronárias/terapia , Reestenose Coronária/prevenção & controle , Humanos , Infarto do Miocárdio/terapia , Síndrome
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA