Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Radiology ; 312(2): e232380, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-39105648

RESUMO

Background It is unclear whether breast US screening outcomes for women with dense breasts vary with levels of breast cancer risk. Purpose To evaluate US screening outcomes for female patients with dense breasts and different estimated breast cancer risk levels. Materials and Methods This retrospective observational study used data from US screening examinations in female patients with heterogeneously or extremely dense breasts conducted from January 2014 to October 2020 at 24 radiology facilities within three Breast Cancer Surveillance Consortium (BCSC) registries. The primary outcomes were the cancer detection rate, false-positive biopsy recommendation rate, and positive predictive value of biopsies performed (PPV3). Risk classification of participants was performed using established BCSC risk prediction models of estimated 6-year advanced breast cancer risk and 5-year invasive breast cancer risk. Differences in high- versus low- or average-risk categories were assessed using a generalized linear model. Results In total, 34 791 US screening examinations from 26 489 female patients (mean age at screening, 53.9 years ± 9.0 [SD]) were included. The overall cancer detection rate per 1000 examinations was 2.0 (95% CI: 1.6, 2.4) and was higher in patients with high versus low or average risk of 6-year advanced breast cancer (5.5 [95% CI: 3.5, 8.6] vs 1.3 [95% CI: 1.0, 1.8], respectively; P = .003). The overall false-positive biopsy recommendation rate per 1000 examinations was 29.6 (95% CI: 22.6, 38.6) and was higher in patients with high versus low or average 6-year advanced breast cancer risk (37.0 [95% CI: 28.2, 48.4] vs 28.1 [95% CI: 20.9, 37.8], respectively; P = .04). The overall PPV3 was 6.9% (67 of 975; 95% CI: 5.3, 8.9) and was higher in patients with high versus low or average 6-year advanced cancer risk (15.0% [15 of 100; 95% CI: 9.9, 22.2] vs 4.9% [30 of 615; 95% CI: 3.3, 7.2]; P = .01). Similar patterns in outcomes were observed by 5-year invasive breast cancer risk. Conclusion The cancer detection rate and PPV3 of supplemental US screening increased with the estimated risk of advanced and invasive breast cancer. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Helbich and Kapetas in this issue.


Assuntos
Densidade da Mama , Neoplasias da Mama , Detecção Precoce de Câncer , Ultrassonografia Mamária , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Detecção Precoce de Câncer/métodos , Ultrassonografia Mamária/métodos , Medição de Risco , Adulto , Mama/diagnóstico por imagem , Mama/patologia , Estados Unidos , Idoso , Programas de Rastreamento/métodos , Sistema de Registros
2.
Radiol Imaging Cancer ; 6(3): e230161, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38578209

RESUMO

Purpose To evaluate long-term trends in mammography screening rates and identify sociodemographic and breast cancer risk characteristics associated with return to screening after the COVID-19 pandemic. Materials and Methods In this retrospective study, statewide screening mammography data of 222 384 female individuals aged 40 years or older (mean age, 58.8 years ± 11.7 [SD]) from the Vermont Breast Cancer Surveillance System were evaluated to generate descriptive statistics and Joinpoint models to characterize screening patterns during 2000-2022. Log-binomial regression models estimated associations of sociodemographic and risk characteristics with post-COVID-19 pandemic return to screening. Results The proportion of female individuals in Vermont aged 50-74 years with a screening mammogram obtained in the previous 2 years declined from a prepandemic level of 61.3% (95% CI: 61.1%, 61.6%) in 2019 to 56.0% (95% CI: 55.7%, 56.3%) in 2021 before rebounding to 60.7% (95% CI: 60.4%, 61.0%) in 2022. Screening adherence in 2022 remained substantially lower than that observed during the 2007-2010 apex of screening adherence (66.1%-67.0%). Joinpoint models estimated an annual percent change of -1.1% (95% CI: -1.5%, -0.8%) during 2010-2022. Among the cohort of 95 644 individuals screened during January 2018-March 2020, the probability of returning to screening during 2020-2022 varied by age (eg, risk ratio [RR] = 0.94 [95% CI: 0.93, 0.95] for age 40-44 vs age 60-64 years), race and ethnicity (RR = 0.84 [95% CI: 0.78, 0.90] for Black vs White individuals), education (RR = 0.84 [95% CI: 0.81, 0.86] for less than high school degree vs college degree), and by 5-year breast cancer risk (RR = 1.06 [95% CI: 1.04, 1.08] for very high vs average risk). Conclusion Despite a rebound to near prepandemic levels, Vermont mammography screening rates have steadily declined since 2010, with certain sociodemographic groups less likely to return to screening after the pandemic. Keywords: Mammography, Breast, Health Policy and Practice, Neoplasms-Primary, Epidemiology, Screening Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Neoplasias da Mama , COVID-19 , Feminino , Humanos , Pessoa de Meia-Idade , Mamografia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Pandemias/prevenção & controle , Estudos Retrospectivos , Detecção Precoce de Câncer/métodos , COVID-19/epidemiologia , Fatores de Risco , Sistema de Registros
3.
Cancer ; 129(16): 2456-2468, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37303202

RESUMO

BACKGROUND: There are no consensus guidelines for supplemental breast cancer screening with whole-breast ultrasound. However, criteria for women at high risk of mammography screening failures (interval invasive cancer or advanced cancer) have been identified. Mammography screening failure risk was evaluated among women undergoing supplemental ultrasound screening in clinical practice compared with women undergoing mammography alone. METHODS: A total of 38,166 screening ultrasounds and 825,360 screening mammograms without supplemental screening were identified during 2014-2020 within three Breast Cancer Surveillance Consortium (BCSC) registries. Risk of interval invasive cancer and advanced cancer were determined using BCSC prediction models. High interval invasive breast cancer risk was defined as heterogeneously dense breasts and BCSC 5-year breast cancer risk ≥2.5% or extremely dense breasts and BCSC 5-year breast cancer risk ≥1.67%. Intermediate/high advanced cancer risk was defined as BCSC 6-year advanced breast cancer risk ≥0.38%. RESULTS: A total of 95.3% of 38,166 ultrasounds were among women with heterogeneously or extremely dense breasts, compared with 41.8% of 825,360 screening mammograms without supplemental screening (p < .0001). Among women with dense breasts, high interval invasive breast cancer risk was prevalent in 23.7% of screening ultrasounds compared with 18.5% of screening mammograms without supplemental imaging (adjusted odds ratio, 1.35; 95% CI, 1.30-1.39); intermediate/high advanced cancer risk was prevalent in 32.0% of screening ultrasounds versus 30.5% of screening mammograms without supplemental screening (adjusted odds ratio, 0.91; 95% CI, 0.89-0.94). CONCLUSIONS: Ultrasound screening was highly targeted to women with dense breasts, but only a modest proportion were at high mammography screening failure risk. A clinically significant proportion of women undergoing mammography screening alone were at high mammography screening failure risk.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Detecção Precoce de Câncer/métodos , Mamografia/métodos , Fatores de Risco , Ultrassonografia Mamária , Programas de Rastreamento/métodos , Densidade da Mama
4.
Radiology ; 307(5): e223142, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37249433

RESUMO

Background Prior cross-sectional studies have observed that breast cancer screening with digital breast tomosynthesis (DBT) has a lower recall rate and higher cancer detection rate compared with digital mammography (DM). Purpose To evaluate breast cancer screening outcomes with DBT versus DM on successive screening rounds. Materials and Methods In this retrospective cohort study, data from 58 breast imaging facilities in the Breast Cancer Surveillance Consortium were collected. Analysis included women aged 40-79 years undergoing DBT or DM screening from 2011 to 2020. Absolute differences in screening outcomes by modality and screening round were estimated during the study period by using generalized estimating equations with marginal standardization to adjust for differences in women's risk characteristics across modality and round. Results A total of 523 485 DBT examinations (mean age of women, 58.7 years ± 9.7 [SD]) and 1 008 123 DM examinations (mean age, 58.4 years ± 9.8) among 504 863 women were evaluated. DBT and DM recall rates decreased with successive screening round, but absolute recall rates in each round were significantly lower with DBT versus DM (round 1 difference, -3.3% [95% CI: -4.6, -2.1] [P < .001]; round 2 difference, -1.8% [95% CI: -2.9, -0.7] [P = .003]; round 3 or above difference, -1.2% [95% CI: -2.4, -0.1] [P = .03]). DBT had significantly higher cancer detection (difference, 0.6 per 1000 examinations [95% CI: 0.2, 1.1]; P = .009) compared with DM only for round 3 and above. There were no significant differences in interval cancer rate (round 1 difference, 0.00 per 1000 examinations [95% CI: -0.24, 0.30] [P = .96]; round 2 or above difference, 0.04 [95% CI: -0.19, 0.31] [P = .76]) or total advanced cancer rate (round 1 difference, 0.00 per 1000 examinations [95% CI: -0.15, 0.19] [P = .94]; round 2 or above difference, -0.06 [95% CI: -0.18, 0.11] [P = .43]). Conclusion DBT had lower recall rates and could help detect more cancers than DM across three screening rounds, with no difference in interval or advanced cancer rates. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Skaane in this issue.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasias da Mama/epidemiologia , Densidade da Mama , Estudos Retrospectivos , Estudos Transversais , Detecção Precoce de Câncer/métodos , Mamografia/métodos , Programas de Rastreamento/métodos
5.
AJR Am J Roentgenol ; 219(6): 854-868, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35544374

RESUMO

Annual surveillance mammography is recommended for breast cancer survivors on the basis of observational studies and meta-analyses showing reduced breast cancer mortality and improved quality of life. However, breast cancer survivors are at higher risk of subsequent breast cancer and have a fourfold increased risk of interval breast cancers compared with individuals without a personal history of breast cancer. Supplemental surveillance modalities offer increased cancer detection compared with mammography alone, but utilization is variable, and benefits must be balanced with possible harms of false-positive findings. In this review, we describe the current state of mammographic surveillance, summarize evidence for supplemental surveillance in breast cancer survivors, and explore a risk-based approach to selecting surveillance imaging strategies. Further research identifying predictors associated with increased risk of interval second breast cancers and development of validated risk prediction tools may help physicians and patients weigh the benefits and harms of surveillance breast imaging and decide on a personalized approach to surveillance for improved breast cancer outcomes.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/epidemiologia , Qualidade de Vida , Mamografia/métodos , Mama/diagnóstico por imagem , Sobreviventes , Detecção Precoce de Câncer/métodos
6.
Radiology ; 303(2): 287-294, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34665032

RESUMO

Background The COVID-19 pandemic reduced mammography use, potentially delaying breast cancer diagnoses. Purpose To examine breast biopsy recommendations and breast cancers diagnosed before and during the COVID-19 pandemic by mode of detection (screen detected vs symptomatic) and women's characteristics. Materials and Methods In this secondary analysis of prospectively collected data, monthly breast biopsy recommendations after mammography, US, or both with subsequent biopsy performed were examined from 66 facilities of the Breast Cancer Surveillance Consortium between January 2019 and September 2020. The number of monthly and cumulative biopsies recommended and performed and the number of subsequent cancers diagnosed during the pandemic period (March 2020 to September 2020) were compared with data from the prepandemic period using Wald χ2 tests. Analyses were stratified by mode of detection and race or ethnicity. Results From January 2019 to September 2020, 17 728 biopsies were recommended and performed, with 6009 cancers diagnosed. From March to September 2020, there were substantially fewer breast biopsy recommendations with cancer diagnoses when compared with the same period in 2019 (1650 recommendations in 2020 vs 2171 recommendations in 2019 [24% fewer], P < .001), predominantly due to fewer screen-detected cancers (722 cancers in 2020 vs 1169 cancers in 2019 [38% fewer], P < .001) versus symptomatic cancers (895 cancers in 2020 vs 965 cancers in 2019 [7% fewer], P = .27). The decrease in cancer diagnoses was largest in Asian (67 diagnoses in 2020 vs 142 diagnoses in 2019 [53% fewer], P = .06) and Hispanic (82 diagnoses in 2020 vs 145 diagnoses in 2019 [43% fewer], P = .13) women, followed by Black women (210 diagnoses in 2020 vs 287 diagnoses in 2019 [27% fewer], P = .21). The decrease was smallest in non-Hispanic White women (1128 diagnoses in 2020 vs 1357 diagnoses in 2019 [17% fewer], P = .09). Conclusion There were substantially fewer breast biopsies with cancer diagnoses during the COVID-19 pandemic from March to September 2020 compared with the same period in 2019, with Asian and Hispanic women experiencing the largest declines, followed by Black women. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Heller in this issue.


Assuntos
Neoplasias da Mama , COVID-19 , Biópsia , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Feminino , Humanos , Pandemias
7.
Breast Cancer Res ; 23(1): 105, 2021 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-34753492

RESUMO

BACKGROUND: Elevated mammographic breast density is a strong breast cancer risk factor with poorly understood etiology. Increased deposition of collagen, one of the main fibrous proteins present in breast stroma, has been associated with increased mammographic density. Collagen fiber architecture has been linked to poor outcomes in breast cancer. However, relationships of quantitative collagen fiber features assessed in diagnostic biopsies with mammographic density and lesion severity are not well-established. METHODS: Clinically indicated breast biopsies from 65 in situ or invasive breast cancer cases and 73 frequency matched-controls with a benign biopsy result were used to measure collagen fiber features (length, straightness, width, alignment, orientation and density (fibers/µm2)) using second harmonic generation microscopy in up to three regions of interest (ROIs) per biopsy: normal, benign breast disease, and cancer. Local and global mammographic density volumes were quantified in the ipsilateral breast in pre-biopsy full-field digital mammograms. Associations of fibrillar collagen features with mammographic density and severity of biopsy diagnosis were evaluated using generalized estimating equation models with an independent correlation structure to account for multiple ROIs within each biopsy section. RESULTS: Collagen fiber density was positively associated with the proportion of stroma on the biopsy slide (p < 0.001) and with local percent mammographic density volume at both the biopsy target (p = 0.035) and within a 2 mm perilesional ring (p = 0.02), but not with global mammographic density measures. As severity of the breast biopsy diagnosis increased at the ROI level, collagen fibers tended to be less dense, shorter, straighter, thinner, and more aligned with one another (p < 0.05). CONCLUSIONS: Collagen fiber density was positively associated with local, but not global, mammographic density, suggesting that collagen microarchitecture may not translate into macroscopic mammographic features. However, collagen fiber features may be markers of cancer risk and/or progression among women referred for biopsy based on abnormal breast imaging.


Assuntos
Densidade da Mama , Mama/metabolismo , Mama/patologia , Colágeno/metabolismo , Adulto , Idoso , Mama/diagnóstico por imagem , Doenças Mamárias/diagnóstico por imagem , Doenças Mamárias/metabolismo , Doenças Mamárias/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Feminino , Humanos , Biópsia Guiada por Imagem , Mamografia , Microscopia , Pessoa de Meia-Idade , Células Estromais/metabolismo , Células Estromais/patologia
8.
Prev Med ; 152(Pt 2): 106741, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34302837

RESUMO

Breast cancer is the most common cancer and the second most common cause of cancer mortality among women in the United States. Efforts to promote breast cancer control in rural settings face specific challenges. Access to breast cancer screening, diagnosis, and treatment services is impaired by shortages of primary care and specialist providers, and geographic distance from medical facilities. Women in rural areas have comparable breast cancer mortality rates compared to women in urban settings, but this is due in large part to lower incidence rates and masks a substantial rural/urban disparity in breast cancer survival among women diagnosed with breast cancer. Mammography screening utilization rates are slightly lower among rural women than their urban counterparts, with a corresponding increase in late stage breast cancer. Differences in breast cancer survival persist after controlling for stage at diagnosis, largely due to disparities in access to treatment. Travel distance to treatment centers is the most substantial barrier to improved breast cancer outcomes in rural areas. While numerous interventions have been demonstrated in controlled studies to be effective in promoting treatment access and adherence, widespread dissemination in public health and clinical practice remains lacking. Efforts to improve breast cancer control in rural areas should focus on implementation strategies for improving access to breast cancer treatments.


Assuntos
Neoplasias da Mama , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/prevenção & controle , Detecção Precoce de Câncer , Feminino , Acessibilidade aos Serviços de Saúde , Humanos , Mamografia , População Rural , Estados Unidos , População Urbana
9.
J Natl Cancer Inst ; 113(9): 1161-1167, 2021 09 04.
Artigo em Inglês | MEDLINE | ID: mdl-33778894

RESUMO

BACKGROUND: The coronavirus disease 2019 (COVID-19) pandemic led to a near-total cessation of mammography services in the United States in mid-March 2020. It is unclear if screening and diagnostic mammography volumes have recovered to prepandemic levels and whether use has varied by women's characteristics. METHODS: We collected data on 461 083 screening mammograms and 112 207 diagnostic mammograms conducted during January 2019 through July 2020 at 62 radiology facilities in the Breast Cancer Surveillance Consortium. We compared monthly screening and diagnostic mammography volumes before and during the pandemic stratified by age, race and ethnicity, breast density, and family history of breast cancer. RESULTS: Screening and diagnostic mammography volumes in April 2020 were 1.1% (95% confidence interval [CI] = 0.5% to 2.4%) and 21.4% (95% CI = 18.7% to 24.4%) of the April 2019 prepandemic volumes, respectively, but by July 2020 had rebounded to 89.7% (95% CI = 79.6% to 101.1%) and 101.6% (95% CI = 93.8% to 110.1%) of the July 2019 prepandemic volumes, respectively. The year-to-date cumulative volume of screening and diagnostic mammograms performed through July 2020 was 66.2% (95% CI = 60.3% to 72.6%) and 79.9% (95% CI = 75.4% to 84.6%), respectively, of year-to-date volume through July 2019. Screening mammography rebound was similar across age groups and by family history of breast cancer. Monthly screening mammography volume in July 2020 for Black, White, Hispanic, and Asian women reached 96.7% (95% CI = 88.1% to 106.1%), 92.9% (95% CI = 82.9% to 104.0%), 72.7% (95% CI = 56.5% to 93.6%), and 51.3% (95% CI = 39.7% to 66.2%) of the July 2019 prepandemic volume, respectively. CONCLUSIONS: Despite a strong overall rebound in mammography volume by July 2020, the rebound lagged among Asian and Hispanic women, and a substantial cumulative deficit in missed mammograms accumulated, which may have important health consequences.


Assuntos
Neoplasias da Mama/diagnóstico , COVID-19/epidemiologia , Detecção Precoce de Câncer/estatística & dados numéricos , Etnicidade/psicologia , Mamografia/estatística & dados numéricos , Sistema de Registros/estatística & dados numéricos , SARS-CoV-2/isolamento & purificação , Adulto , Idoso , Neoplasias da Mama/psicologia , COVID-19/virologia , Feminino , Humanos , Pessoa de Meia-Idade , Estados Unidos/epidemiologia
10.
Cancer Epidemiol Biomarkers Prev ; 30(1): 80-88, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33082201

RESUMO

BACKGROUND: There is widespread interest in discriminating indolent from aggressive ductal carcinoma in situ (DCIS). We sought to evaluate collagen organization in the DCIS tumor microenvironment in relation to pathologic characteristics and patient outcomes. METHODS: We retrieved fixed tissue specimens for 90 DCIS cases within the population-based Vermont DCIS Cohort. We imaged collagen fibers within 75 µm of the tumor/stromal boundary on hematoxylin and eosin-stained slides using multiphoton microscopy with second-harmonic generation. Automated software quantified collagen fiber length, width, straightness, density, alignment, and angle to the tumor/stroma boundary. Factor analysis identified linear combinations of collagen fiber features representing composite attributes of collagen organization. RESULTS: Multiple collagen features were associated with DCIS grade, necrosis pattern, or periductal fibrosis (P < 0.05). After adjusting for treatments and nuclear grade, risk of recurrence (defined as any second breast cancer diagnosis) was lower among cases with greater collagen fiber width [hazard ratio (HR), 0.57 per one standard deviation increase; 95% confidence interval (CI), 0.39-0.84] and fiber density (HR, 0.60; 95% CI, 0.42-0.85), whereas risk was elevated among DCIS cases with higher fiber straightness (HR, 1.47; 95% CI, 1.05-2.06) and distance to the nearest two fibers (HR, 1.47; 95% CI, 1.06-2.02). Fiber length, alignment, and fiber angle were not associated with recurrence (P > 0.05). Five composite factors were identified, accounting for 72.4% of the total variability among fibers; three were inversely associated with recurrence (HRs ranging from 0.60 to 0.67; P ≤ 0.01). CONCLUSIONS: Multiple aspects of collagen organization around DCIS lesions are associated with recurrence risk. IMPACT: Collagen organization should be considered in the development of prognostic DCIS biomarker signatures.


Assuntos
Neoplasias da Mama/patologia , Carcinoma Intraductal não Infiltrante/patologia , Colágeno/metabolismo , Recidiva Local de Neoplasia , Adulto , Idoso , Estudos de Coortes , Colágeno/ultraestrutura , Feminino , Humanos , Pessoa de Meia-Idade , Sistema de Registros
11.
Radiology ; 297(3): 545-553, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33048032

RESUMO

BackgroundDigital breast tomosynthesis (DBT) combined with digital mammography (DM) is increasingly used in the United States instead of DM alone for breast cancer screening. Early screening outcomes incorporating synthetic mammography (SM) with DBT have suggested that SM is an acceptable non-radiation dose alternative to DM.PurposeTo compare multicenter outcomes from breast cancer screening with SM/DBT versus DM/DBT.Materials and MethodsThis was a retrospective study of consecutive screening mammograms obtained at two institutions. Eligible studies consisted of 34 106 DM/DBT examinations between October 3, 2011, and October 31, 2014, and 34 180 SM/DBT examinations between January 7, 2015, and February 2, 2018, at the University of Pennsylvania and 51 148 DM/DBT examinations between January 1, 2012, and May 31, 2016, and 31 929 SM/DBT examinations between June 1, 2016, and March 30, 2018, at the University of Vermont. Demographics of women who attended screening and results from screening were recorded. Recall rate, biopsy rate, false-negative rate, cancer detection rate, positive predictive value, sensitivity, and specificity were calculated according to modality and institution. Descriptive statistics, χ2 tests, and logistic regression were used in analysis.ResultsThe study included 151 363 screening examinations among 151 363 women (mean age, 58.1 years ± 10.9 [standard deviation]). The unadjusted recall rate was lower with SM/DBT than with DM/DBT (7.0% [4630 of 66 109 examinations] for SM/DBT vs 7.9% [6742 of 85 254 examinations] for DM/DBT; P < .01). However, after multivariable adjustment, SM/DBT was associated with a slightly higher recall rate compared with DM/DBT (adjusted odds ratio [OR], 1.06; adjusted 95% CI: 1.01, 1.11; P = .02). Similarly, after multivariable adjustment, SM/DBT was associated with slightly lower specificity compared with DM/DBT (adjusted OR, 0.95; adjusted 95% CI: 0.90, 0.99; P = .02). There was no statistically significant difference in biopsy rate (P = .54), false-negative rate (P = .38), cancer detection rate (P = .55), invasive or in situ cancer detection rate (P = .52 and P = .98, respectively), positive predictive value (P = .78), or sensitivity (P = .33) for SM/DBT versus DM/DBT overall or within either institution (P > .05 for all).ConclusionBreast cancer screening performance is maintained within benchmarks when synthetic mammography replaces digital mammography in digital breast tomosynthesis imaging.© RSNA, 2020Online supplemental material is available for this article.See also the editorial by Lång in this issue.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Biópsia , Densidade da Mama , Detecção Precoce de Câncer , Feminino , Humanos , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
12.
JAMA Netw Open ; 3(7): e2011792, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32721031

RESUMO

Importance: Digital mammography (DM) and digital breast tomosynthesis (DBT) are used for routine breast cancer screening. There is minimal evidence on performance outcomes by age, screening round, and breast density in community practice. Objective: To compare DM vs DBT performance by age, baseline vs subsequent screening round, and breast density category. Design, Setting, and Participants: This comparative effectiveness study assessed 1 584 079 screening examinations of women aged 40 to 79 years without prior history of breast cancer, mastectomy, or breast augmentation undergoing screening mammography at 46 participating Breast Cancer Surveillance Consortium facilities from January 2010 to April 2018. Exposures: Age, Breast Imaging Reporting and Data System breast density category, screening round, and modality. Main Outcomes and Measures: Absolute rates and relative risks (RRs) of screening recall and cancer detection. Results: Of 1 273 492 DM and 310 587 DBT examinations analyzed, 1 028 891 examinations (65.0%) were of white non-Hispanic women; 399 952 women (25.2%) were younger than 50 years; and 671 136 women (42.4%) had heterogeneously dense or extremely dense breasts. Adjusted differences in DM vs DBT performance were largest on baseline examinations: for example, per 1000 baseline examinations in women ages 50 to 59, recall rates decreased from 241 examinations for DM to 204 examinations for DBT (RR, 0.84; 95% CI, 0.73-0.98), and cancer detection rates increased from 5.9 with DM to 8.8 with DBT (RR, 1.50; 95% CI, 1.10-2.08). On subsequent examinations, women aged 40 to 79 years with heterogeneously dense breasts had improved recall rates and improved cancer detection with DBT. For example, per 1000 examinations in women aged 50 to 59 years, the number of recall examinations decreased from 102 with DM to 93 with DBT (RR, 0.91; 95% CI, 0.84-0.98), and cancer detection increased from 3.7 with DM to 5.3 with DBT (RR, 1.42; 95% CI, 1.23-1.64). Women aged 50 to 79 years with scattered fibroglandular density also had improved recall and cancer detection rates with DBT. Women aged 40 to 49 years with scattered fibroglandular density and women aged 50 to 79 years with almost entirely fatty breasts benefited from improved recall rates without change in cancer detection rates. No improvements in recall or cancer detection rates were observed in women with extremely dense breasts on subsequent examinations for any age group. Conclusions and Relevance: This study found that improvements in recall and cancer detection rates with DBT were greatest on baseline mammograms. On subsequent screening mammograms, the benefits of DBT varied by age and breast density. Women with extremely dense breasts did not benefit from improved recall or cancer detection with DBT on subsequent screening rounds.


Assuntos
Densidade da Mama/fisiologia , Neoplasias da Mama/diagnóstico , Mamografia/normas , Programas de Rastreamento/normas , Adulto , Idoso , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Serviços de Saúde Comunitária/métodos , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Mamografia/métodos , Mamografia/estatística & dados numéricos , Programas de Rastreamento/métodos , Programas de Rastreamento/estatística & dados numéricos , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros/estatística & dados numéricos
13.
JAMA Netw Open ; 3(3): e201759, 2020 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-32227180

RESUMO

Importance: Many US radiologists have screening mammography recall rates above the expert-recommended threshold of 12%. The influence of digital breast tomosynthesis (DBT) on the distribution of radiologist recall rates is uncertain. Objective: To evaluate radiologists' recall and cancer detection rates before and after beginning interpretation of DBT examinations. Design, Setting, and Participants: This cohort study included 198 radiologists from 104 radiology facilities in the Breast Cancer Surveillance Consortium who interpreted 251 384 DBT and 2 000 681 digital mammography (DM) screening examinations from 2009 to 2017, including 126 radiologists (63.6%) who interpreted DBT examinations during the study period and 72 (36.4%) who exclusively interpreted DM examinations (to adjust for secular trends). Data were analyzed from April 2018 to July 2019. Exposures: Digital breast tomosynthesis and DM screening examinations. Main Outcomes and Measures: Recall rate and cancer detection rate. Results: A total of 198 radiologists interpreted 2 252 065 DM and DBT examinations (2 000 681 [88.8%] DM examinations; 251 384 [11.2%] DBT examinations; 710 934 patients [31.6%] aged 50-59 years; 1 448 981 [64.3%] non-Hispanic white). Among the 126 radiologists (63.6%) who interpreted DBT examinations, 83 (65.9%) had unadjusted DM recall rates of no more than 12% before using DBT, with a median (interquartile range) recall rate of 10.0% (7.5%-13.0%). On DBT examinations, 96 (76.2%) had an unadjusted recall rate of no more than 12%, with a median (interquartile range) recall rate of 8.8% (6.3%-11.3%). A secular trend in recall rate was observed, with the multivariable-adjusted risk of recall on screening examinations declining by 1.2% (95% CI, 0.9%-1.5%) per year. After adjusting for examination characteristics and secular trends, recall rates were 15% lower on DBT examinations compared with DM examinations interpreted before DBT use (relative risk, 0.85; 95% CI, 0.83-0.87). Adjusted recall rates were significantly lower on DBT examinations compared with DM examinations interpreted before DBT use for 45 radiologists (35.7%) and significantly higher for 18 (14.3%); 63 (50.0%) had no statistically significant change. The unadjusted cancer detection rate on DBT was 5.3 per 1000 examinations (95% CI, 5.0-5.7 per 1000 examinations) compared with 4.7 per 1000 examinations (95% CI, 4.6-4.8 per 1000 examinations) on DM examinations interpreted before DM use (multivariable-adjusted risk ratio, 1.21; 95% CI, 1.11-1.33). Conclusions and Relevance: In this study, DBT was associated with an overall decrease in recall rate and an increase in cancer detection rate. However, our results indicated that there is wide variability among radiologists, including a subset of radiologists who experienced increased recall rates on DBT examinations. Radiology practices should audit radiologist DBT screening performance and consider additional DBT training for radiologists whose performance does not improve as expected.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia , Radiologistas , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/epidemiologia , Estudos de Coortes , Feminino , Humanos , Mamografia/métodos , Mamografia/estatística & dados numéricos , Pessoa de Meia-Idade , Radiologistas/normas , Radiologistas/estatística & dados numéricos , Estados Unidos
14.
J Clin Med ; 9(1)2020 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-31963437

RESUMO

The association of progesterone/progesterone metabolites with elevated mammographic breast density (MBD) and delayed age-related terminal duct lobular unit (TDLU) involution, strong breast cancer risk factors, has received limited attention. Using a reliable liquid chromatography-tandem mass-spectrometry assay, we quantified serum progesterone/progesterone metabolites and explored cross-sectional relationships with MBD and TDLU involution among women, ages 40-65, undergoing diagnostic breast biopsy. Quantitative MBD measures were estimated in pre-biopsy digital mammograms. TDLU involution was quantified in diagnostic biopsies. Adjusted partial correlations and trends across MBD/TDLU categories were calculated. Pregnenolone was positively associated with percent MBD-area (MBD-A, rho: 0.30; p-trend = 0.01) among premenopausal luteal phase women. Progesterone tended to be positively associated with percent MBD-A among luteal phase (rho: 0.26; p-trend = 0.07) and postmenopausal (rho: 0.17; p-trend = 0.04) women. Consistent with experimental data, implicating an elevated 5α-pregnanes/3α-dihydroprogesterone (5αP/3αHP) metabolite ratio in breast cancer, higher 5αP/3αHP was associated with elevated percent MBD-A among luteal phase (rho: 0.29; p-trend = 0.08), but not postmenopausal women. This exploratory analysis provided some evidence that endogenous progesterone and progesterone metabolites might be correlated with MBD, a strong breast cancer risk factor, in both pre- and postmenopausal women undergoing breast biopsy. Additional studies are needed to understand the role of progesterone/progesterone metabolites in breast tissue composition and breast cancer risk.

15.
J Am Coll Radiol ; 17(1 Pt A): 31-37, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31415739

RESUMO

Synthesized digital mammography (SM) was developed to replace digital mammography (DM) in digital breast tomosynthesis (DBT) imaging to reduce radiation dose. This survey assessed utilization and attitudes regarding SM in DBT screening. The study was institutional review board exempt. An online survey was sent to members of the Society of Breast Imaging in June 2018. Questions included practice information, utilization of DBT and SM, perception of change in recall rates (RRs) and cancer detection rates (CDRs) with SM-DBT versus DM-DBT, and attitudes regarding SM versus DM in DBT screening. χ2 Tests were used to compare response frequencies across groups. In all, 312 of 2,600 Society of Breast Imaging members responded to the survey (12%). Of respondents, 96% reported DBT capability, and 83% reported SM capability. Of those without SM, the most cited reasons were cost or administration and image quality concerns (both 32%). In addition, 40% reported combined SM and DM use in DBT screens, and 52% reported SM use without DM in the majority of DBT screens. The overall satisfaction with SM was 3.4 of 5 (1-5 scale). Most cited SM advantages were decreased dose (85%) and increased lesion conspicuity (27%). The most cited SM disadvantages were calcification characterization (61%) and decreased image quality (31%). Most respondents were unsure if CDRs changed (44%) and RR changed (30%) with few reporting adverse outcomes (6% RR increase, 1% CDR decrease). Most radiologists screening with DBT have SM, but only one-half have replaced DM with SM. Despite few reported adverse screening outcomes with SM-DBT, radiologists have concerns about image quality, specifically calcification characterization.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Programas de Rastreamento/métodos , Padrões de Prática Médica/estatística & dados numéricos , Densidade da Mama , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Estudos Prospectivos , Revisão da Utilização de Recursos de Saúde
16.
NPJ Breast Cancer ; 5: 43, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31754628

RESUMO

Breast density, a breast cancer risk factor, is a radiologic feature that reflects fibroglandular tissue content relative to breast area or volume. Its histology is incompletely characterized. Here we use deep learning approaches to identify histologic correlates in radiologically-guided biopsies that may underlie breast density and distinguish cancer among women with elevated and low density. We evaluated hematoxylin and eosin (H&E)-stained digitized images from image-guided breast biopsies (n = 852 patients). Breast density was assessed as global and localized fibroglandular volume (%). A convolutional neural network characterized H&E composition. In total 37 features were extracted from the network output, describing tissue quantities and morphological structure. A random forest regression model was trained to identify correlates most predictive of fibroglandular volume (n = 588). Correlations between predicted and radiologically quantified fibroglandular volume were assessed in 264 independent patients. A second random forest classifier was trained to predict diagnosis (invasive vs. benign); performance was assessed using area under receiver-operating characteristics curves (AUC). Using extracted features, regression models predicted global (r = 0.94) and localized (r = 0.93) fibroglandular volume, with fat and non-fatty stromal content representing the strongest correlates, followed by epithelial organization rather than quantity. For predicting cancer among high and low fibroglandular volume, the classifier achieved AUCs of 0.92 and 0.84, respectively, with epithelial organizational features ranking most important. These results suggest non-fatty stroma, fat tissue quantities and epithelial region organization predict fibroglandular volume. The model holds promise for identifying histological correlates of cancer risk in patients with high and low density and warrants further evaluation.

17.
Cancer Prev Res (Phila) ; 12(12): 861-870, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31645342

RESUMO

Delayed terminal duct lobular unit (TDLU) involution is associated with elevated mammographic breast density (MD). Both are independent breast cancer risk factors among women with benign breast disease (BBD). Prior digital analyses of normal breast tissues revealed that epithelial nuclear density (END) and TDLU involution are inversely correlated. Accordingly, we examined associations of END, TDLU involution, and MD in BBD clinical biopsies. This study included digitized images of 262 representative image-guided hematoxylin and eosin-stained biopsies from 224 women diagnosed with BBD, enrolled within the cross-sectional BREAST-Stamp project that were visually assessed for TDLU involution (TDLU count/100 mm2, median TDLU span and median acini count per TDLU). A digital algorithm estimated nuclei count per unit epithelial area, or END. Single X-ray absorptiometry of prebiopsy ipsilateral craniocaudal digital mammograms measured global and localized MD surrounding the biopsy region. Adjusted ordinal logistic regression models assessed relationships between tertiles of TDLU and END measures. Analysis of covariance examined mean differences in MD across END tertiles. TDLU measures were positively associated with increasing END tertiles [TDLU count/100 mm2, ORT3vsT1: 3.42, 95% confidence interval (CI), 1.87-6.28; acini count/TDLUT3vsT1, OR: 2.40, 95% CI, 1.39-4.15]. END was significantly associated with localized, but not, global MD. Relationships were most apparent among patients with nonproliferative BBD. These findings suggest that quantitative END reflects different but complementary information to the histologic information captured by visual TDLU and radiologic MD measures and merits continued evaluation in assessing cellularity of breast parenchyma to understand the etiology of BBD.


Assuntos
Neoplasias da Mama/prevenção & controle , Mama/patologia , Epitélio/patologia , Doença da Mama Fibrocística/diagnóstico , Interpretação de Imagem Assistida por Computador , Absorciometria de Fóton , Adulto , Fatores Etários , Idoso , Algoritmos , Mama/diagnóstico por imagem , Densidade da Mama , Neoplasias da Mama/epidemiologia , Estudos Transversais , Feminino , Doença da Mama Fibrocística/patologia , Humanos , Biópsia Guiada por Imagem/métodos , Modelos Logísticos , Mamografia , Pessoa de Meia-Idade , Fatores de Risco
18.
Am J Prev Med ; 57(3): 394-402, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31377088

RESUMO

INTRODUCTION: Despite healthcare reforms mandating expanded insurance coverage and reduced out-of-pocket costs for preventive care, cancer screening rates remain relatively static. No study has measured cancer screening rates for multiple tests among non-Medicare patients. METHODS: This retrospective, population-based claims analysis, conducted in 2016-2017, of commercially insured and Medicaid-insured women aged 30-59 years enrolled in IBM MarketScan Commercial and Medicaid Databases (containing approximately 90 and 17 million enrollees, respectively) during 2010-2015 describes screening rates for breast, cervical, and colorectal cancer. Key outcomes were (1) proportion screened for breast, cervical, and colorectal cancer among the age-eligible population compared with accepted age-based recommendations and (2) proportion with longer-than-recommended intervals between tests. RESULTS: One half (54.7%) of commercially insured women aged 40-59 years (n=1,538,444) were screened three or more times during the 6-year study period for breast cancer; for Medicaid-insured women (n=78,897), the rates were lower (23.7%). One third (43.4%) of commercially insured and two thirds (68.9%) of Medicaid-insured women had a >2.5-year gap between mammograms. Among women aged 30-59 years, 59.3% of commercially insured women and 31.4% of Medicaid-insured women received two or more Pap tests. The proportion of patients with a >3.5-year gap between Pap tests was 33.9% (commercially insured) and 57.1% (Medicaid-insured). Among women aged 50-59 years, 63.3% of commercially insured women and 47.2% of Medicaid-insured women were screened at least one time for colorectal cancer. Almost all women aged 30-59 years (commercially insured, 99.1%; Medicaid-insured, 98.9%) had at least one healthcare encounter. CONCLUSIONS: Breast and cervical cancer screenings remain underutilized among both commercially insured and Medicaid-insured populations, with lower rates among the Medicaid-insured population. However, almost all women had at least one healthcare encounter, suggesting opportunities for better coordinated care.


Assuntos
Neoplasias da Mama/prevenção & controle , Neoplasias Colorretais/prevenção & controle , Programas de Rastreamento/estatística & dados numéricos , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Neoplasias do Colo do Útero/prevenção & controle , Adulto , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/economia , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/economia , Detecção Precoce de Câncer/economia , Detecção Precoce de Câncer/normas , Detecção Precoce de Câncer/estatística & dados numéricos , Feminino , Planos de Seguro com Fins Lucrativos/economia , Planos de Seguro com Fins Lucrativos/legislação & jurisprudência , Planos de Seguro com Fins Lucrativos/normas , Planos de Seguro com Fins Lucrativos/estatística & dados numéricos , Gastos em Saúde/estatística & dados numéricos , Humanos , Programas de Rastreamento/economia , Programas de Rastreamento/normas , Medicaid/economia , Medicaid/legislação & jurisprudência , Medicaid/normas , Medicaid/estatística & dados numéricos , Pessoa de Meia-Idade , Patient Protection and Affordable Care Act/economia , Patient Protection and Affordable Care Act/legislação & jurisprudência , Guias de Prática Clínica como Assunto , Estudos Retrospectivos , Estados Unidos , Neoplasias do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/economia
19.
Breast Cancer Res ; 21(1): 81, 2019 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-31337427

RESUMO

BACKGROUND: Mammographic density (MD) is a strong breast cancer risk factor that reflects fibroglandular and adipose tissue composition, but its biologic underpinnings are poorly understood. Insulin-like growth factor binding proteins (IGFBPs) are markers that may be associated with MD given their hypothesized role in breast carcinogenesis. IGFBPs sequester IGF-I, limiting its bioavailability. Prior studies have found positive associations between circulating IGF-I and the IGF-I:IGFBP-3 ratio and breast cancer risk. We evaluated the associations of IGF-I, IGFBP-3, and six other IGFBPs with MD. METHODS: Serum IGF measures were quantified in 296 women, ages 40-65, undergoing diagnostic image-guided breast biopsy. Volumetric density measures (MD-V) were assessed in pre-biopsy digital mammograms using single X-ray absorptiometry. Area density measures (MD-A) were estimated by computer-assisted thresholding software. Age, body mass index (BMI), and BMI2-adjusted linear regression models were used to examine associations of serum IGF measures with MD. Effect modification by BMI was also assessed. RESULTS: IGF-I and IGFBP-3 were not strongly associated with MD after BMI adjustment. In multivariable analyses among premenopausal women, IGFBP-2 was positively associated with both percent MD-V (ß = 1.49, p value = 0.02) and MD-A (ß = 1.55, p value = 0.05). Among postmenopausal women, positive relationships between IGFBP-2 and percent MD-V (ß = 2.04, p = 0.003) were observed; the positive associations between IGFBP-2 and percent MD-V were stronger among lean women (BMI < 25 kg/m2) (ß = 5.32, p = 0.0002; p interaction = 0.0003). CONCLUSIONS: In this comprehensive study of IGFBPs and MD, we observed a novel positive association between IGFBP-2 and MD, particularly among women with lower BMI. In concert with in vitro studies suggesting a dual role of IGFBP-2 on breast tissue, promoting cell proliferation as well as inhibiting tumorigenesis, our findings suggest that further studies assessing the role of IGFBP-2 in breast tissue composition, in addition to IGF-1 and IGFBP-3, are warranted.


Assuntos
Densidade da Mama , Neoplasias da Mama/sangue , Neoplasias da Mama/diagnóstico , Biópsia Guiada por Imagem , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/sangue , Fator de Crescimento Insulin-Like I/metabolismo , Adulto , Biomarcadores , Estudos Transversais , Feminino , Humanos , Mamografia , Pessoa de Meia-Idade , Fatores de Risco
20.
JAMA Oncol ; 5(5): 635-642, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30816931

RESUMO

IMPORTANCE: Breast cancer screening examinations using digital breast tomosynthesis (DBT) has been shown to be associated with decreased false-positive test results and increased breast cancer detection compared with digital mammography (DM). Little is known regarding the size and stage of breast cancer types detected and their association with age and breast density. OBJECTIVE: To determine whether screening examinations using DBT detect breast cancers that are associated with an improved prognosis and to compare the detection rates by patient age and breast density. DESIGN, SETTING, AND PARTICIPANTS: This retrospective analysis of prospective cohort data from 3 research centers in the Population-based Research Optimizing Screening Through Personalized Regimens (PROSPR) consortium included data of women aged 40 to 74 years who underwent screening examinations using DM and DBT from January 1, 2011, through September 30, 2014. Statistical analysis was performed from November 8, 2017, to August 14, 2018. EXPOSURES: Use of DBT as a supplement to DM at breast cancer screening examination. MAIN OUTCOMES AND MEASURES: Recall rate, cancer detection rate, positive predictive value, biopsy rate, and distribution of invasive cancer subtypes. RESULTS: Among 96 269 women (mean [SD] patient age for all examinations, 55.9 [9.0] years), patient age was 56.4 (9.0) years for DM and 54.6 (8.9) years for DBT. Of 180 340 breast cancer screening examinations, 129 369 examinations (71.7%) used DM and 50 971 examinations (28.3%) used DBT. Screening examination with DBT (73 of 99 women [73.7%]) was associated with the detection of smaller, more often node-negative, HER2-negative, invasive cancers compared with DM (276 of 422 women [65.4%]). Screening examination with DBT was also associated with lower recall (odds ratio, 0.64; 95% CI, 0.57-0.72; P < .001) and higher cancer detection (odds ratio, 1.41; 95% CI, 1.05-1.89; P = .02) compared with DM for all age groups even when stratified by breast density. The largest increase in cancer detection rate and the greatest shift toward smaller, node-negative invasive cancers detected with DBT was for women aged 40 to 49 years. For women aged 40 to 49 years with nondense breasts, the cancer detection rate for examinations using DBT was 1.70 per 1000 women higher compared with the rate using DM; for women with dense breasts, the cancer detection rate was 2.27 per 1000 women higher for DBT. For these younger women, screening with DBT was associated with only 7 of 28 breast cancers (25.0%) categorized as poor prognosis compared with 19 of 47 breast cancers (40.4%) when screening with DM. CONCLUSIONS AND RELEVANCE: The findings suggest that screening with DBT is associated with increased specificity and an increased proportion of breast cancers detected with better prognosis compared with DM. In the subgroup of women aged 40 to 49 years, routine DBT screening may have a favorable risk-benefit ratio.


Assuntos
Densidade da Mama , Neoplasias da Mama/diagnóstico , Mama/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Mamografia/métodos , Programas de Rastreamento/métodos , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA