Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Eur Radiol ; 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38836939

RESUMO

OBJECTIVE: Improving prognostication to direct personalised therapy remains an unmet need. This study prospectively investigated promising CT, genetic, and immunohistochemical markers to improve the prediction of colorectal cancer recurrence. MATERIAL AND METHODS: This multicentre trial (ISRCTN 95037515) recruited patients with primary colorectal cancer undergoing CT staging from 13 hospitals. Follow-up identified cancer recurrence and death. A baseline model for cancer recurrence at 3 years was developed from pre-specified clinicopathological variables (age, sex, tumour-node stage, tumour size, location, extramural venous invasion, and treatment). Then, CT perfusion (blood flow, blood volume, transit time and permeability), genetic (RAS, RAF, and DNA mismatch repair), and immunohistochemical markers of angiogenesis and hypoxia (CD105, vascular endothelial growth factor, glucose transporter protein, and hypoxia-inducible factor) were added to assess whether prediction improved over tumour-node staging alone as the main outcome measure. RESULTS: Three hundred twenty-six of 448 participants formed the final cohort (226 male; mean 66 ± 10 years. 227 (70%) had ≥ T3 stage cancers; 151 (46%) were node-positive; 81 (25%) developed subsequent recurrence. The sensitivity and specificity of staging alone for recurrence were 0.56 [95% CI: 0.44, 0.67] and 0.58 [0.51, 0.64], respectively. The baseline clinicopathologic model improved specificity (0.74 [0.68, 0.79], with equivalent sensitivity of 0.57 [0.45, 0.68] for high vs medium/low-risk participants. The addition of prespecified CT perfusion, genetic, and immunohistochemical markers did not improve prediction over and above the clinicopathologic model (sensitivity, 0.58-0.68; specificity, 0.75-0.76). CONCLUSION: A multivariable clinicopathological model outperformed staging in identifying patients at high risk of recurrence. Promising CT, genetic, and immunohistochemical markers investigated did not further improve prognostication in rigorous prospective evaluation. CLINICAL RELEVANCE STATEMENT: A prognostic model based on clinicopathological variables including age, sex, tumour-node stage, size, location, and extramural venous invasion better identifies colorectal cancer patients at high risk of recurrence for neoadjuvant/adjuvant therapy than stage alone. KEY POINTS: Identification of colorectal cancer patients at high risk of recurrence is an unmet need for treatment personalisation. This model for recurrence, incorporating many patient variables, had higher specificity than staging alone. Continued optimisation of risk stratification schema will help individualise treatment plans and follow-up schedules.

2.
Surg Endosc ; 38(6): 3368-3377, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38710889

RESUMO

BACKGROUND: Transanal minimally invasive surgery (TAMIS) is an advanced technique for excision of early rectal cancers. Robotic TAMIS (r-TAMIS) has been introduced as technical improvement and potential alternative to total mesorectal excision (TME) in early rectal cancers and in frail patients. This study reports the perioperative and short-term oncological outcomes of r-TAMIS for local excision of early-stage rectal cancers. METHODS: Retrospective analysis of a prospectively collected r-TAMIS database (July 2021-July 2023). Demographics, clinicopathological features, short-term outcomes, recurrences, and survival were investigated. RESULTS: Twenty patients were included. Median age and body mass index were 69.5 (62.0-77.7) years and 31.0 (21.0-36.5) kg/m2. Male sex was prevalent (n = 12, 60.0%). ASA III accounted for 66.7%. Median distance from anal verge was 7.5 (5.0-11.7) cm. Median operation time was 90.0 (60.0-112.5) minutes. Blood loss was minimal. There were no conversions. Median postoperative stay was 2.0 (1.0-3.0) days. Minor and major complication rates were 25.0% and 0%, respectively. Seventeen (85.0%) patients had an adenocarcinoma whilst three patients had an adenoma. R0 rate was 90.0%. Most tumours were pT1 (55.0%), followed by pT2 (25.0%). One patient (5.0%) had a pT3 tumour. Specimen and tumour maximal median diameter were 51.0 (41.0-62.0) mm and 21.5 (17.2-42.0) mm, respectively. Median specimen area was 193.1 (134.3-323.3) cm2. Median follow-up was 15.5 (10.0-24.0) months. One patient developed local recurrence (5.0%). CONCLUSIONS: r-TAMIS, with strict postoperative surveillance, is a safe and feasible approach for local excision of early rectal cancer and may have a role in surgically unfit and elderly patients who refuse or cannot undergo TME surgery. Future prospective multicentre large-scale studies are needed to report the long-term oncological outcomes.


Assuntos
Neoplasias Retais , Procedimentos Cirúrgicos Robóticos , Cirurgia Endoscópica Transanal , Humanos , Neoplasias Retais/cirurgia , Neoplasias Retais/patologia , Masculino , Procedimentos Cirúrgicos Robóticos/métodos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Cirurgia Endoscópica Transanal/métodos , Resultado do Tratamento , Duração da Cirurgia , Tempo de Internação/estatística & dados numéricos , Recidiva Local de Neoplasia/epidemiologia
3.
Eur Radiol ; 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38488970

RESUMO

BACKGROUND: The Paris classification categorises colorectal polyp morphology. Interobserver agreement for Paris classification has been assessed at optical colonoscopy (OC) but not CT colonography (CTC). We aimed to determine the following: (1) interobserver agreement for the Paris classification using CTC between radiologists; (2) if radiologist experience influenced classification, gross polyp morphology, or polyp size; and (3) the extent to which radiologist classifications agreed with (a) colonoscopy and (b) a combined reference standard. METHODS: Following ethical approval for this non-randomised prospective cohort study, seven radiologists from three hospitals classified 52 colonic polyps using the Paris system. We calculated interobserver agreement using Fleiss kappa and mean pairwise agreement (MPA). Absolute agreement was calculated between radiologists; between CTC and OC; and between CTC and a combined reference standard using all available imaging, colonoscopic, and histopathological data. RESULTS: Overall interobserver agreement between the seven readers was fair (Fleiss kappa 0.33; 95% CI 0.30-0.37; MPA 49.7%). Readers with < 1500 CTC experience had higher interobserver agreement (0.42 (95% CI 0.35-0.48) vs. 0.33 (95% CI 0.25-0.42)) and MPA (69.2% vs 50.6%) than readers with ≥ 1500 experience. There was substantial overall agreement for flat vs protuberant polyps (0.62 (95% CI 0.56-0.68)) with a MPA of 87.9%. Agreement between CTC and OC classifications was only 44%, and CTC agreement with the combined reference standard was 56%. CONCLUSION: Radiologist agreement when using the Paris classification at CT colonography is low, and radiologist classification agrees poorly with colonoscopy. Using the full Paris classification in routine CTC reporting is of questionable value. CLINICAL RELEVANCE STATEMENT: Interobserver agreement for radiologists using the Paris classification to categorise colorectal polyp morphology is only fair; routine use of the full Paris classification at CT colonography is questionable. KEY POINTS: • Overall interobserver agreement for the Paris classification at CT colonography (CTC) was only fair, and lower than for colonoscopy. • Agreement was higher for radiologists with < 1500 CTC experience and for larger polyps. There was substantial agreement when classifying polyps as protuberant vs flat. • Agreement between CTC and colonoscopic polyp classification was low (44%).

4.
Eur Radiol ; 34(1): 455-464, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37526665

RESUMO

OBJECTIVES: The simple ultrasound activity score for Crohn's disease (SUS-CD) and bowel ultrasound score (BUSS) are promising intestinal ultrasound (IUS) indices of CD, but studied mainly in small settings with few sonographers. We compared SUS-CD and BUSS against histological and magnetic resonance enterography (MRE) reference standards in a post hoc analysis of a prospective multicentre, multireader trial. METHODS: Participants recruited to the METRIC trial (ISRCTN03982913) were studied, including those with available terminal ileal (TI) biopsies. Sensitivity and specificity of SUS-CD and BUSS for TI CD activity were calculated with 95% confidence intervals (CI), from the prospective observations of the original METRIC trial sonographers against the histological activity index (HAI) and the simplified magnetic resonance index of activity (sMARIA). RESULTS: We included 284 patients (median 31.5 years, IQR 23-46) from 8 centres, who underwent IUS and MRE. Of these, 111 patients had available terminal ileal biopsies with HAI scoring. Against histology, sensitivity and specificity for active disease were 79% (95% CI 69-86%) and 50% (31-69%) for SUS-CD, and 66% (56-75%) and 68% (47-84%) for BUSS, respectively. Compared to sMARIA, the sensitivity and specificity for active CD were 81% (74-86%) and 75% (66-83%) for SUS-CD, and 68% (61-74%) and 85% (76-91%) for BUSS, respectively. The sensitivity of SUS-CD was significantly greater than that of BUSS against HAI and sMARIA (p < 0.001), but its specificity was significantly lower than of BUSS against the MRE reference standard (p = 0.003). CONCLUSIONS: Particularly when compared to MRE activity scoring, SUS-CD and BUSS are promising tools in a real-world clinical setting. CLINICAL RELEVANCE STATEMENT: When tested using data from a multicentre, multireader diagnostic accuracy trial, the simple ultrasound activity score for Crohn's disease (SUS-CD) and bowel ultrasound score (BUSS) were clinically viable intestinal ultrasound indices that were reasonably sensitive and specific for terminal ileal Crohn's disease, especially when compared to a magnetic resonance reference standard. KEY POINTS: The simple ultrasound activity score for Crohn's disease and bowel ultrasound score are promising intestinal ultrasound indices of Crohn's disease but to date studied mainly in small settings with few sonographers. Compared to histology and the magnetic resonance reference standard in a multicentre, multireader setting, the sensitivity of simple ultrasound activity score for Crohn's disease is significantly greater than that of bowel ultrasound score. The specificity of simple ultrasound activity score for Crohn's disease was significantly lower than that of bowel ultrasound score compared to the magnetic resonance enterography reference standard. The specificity of both indices was numerically higher when the magnetic resonance enterography reference standard was adopted.


Assuntos
Doença de Crohn , Adulto , Humanos , Doença de Crohn/patologia , Íleo/diagnóstico por imagem , Íleo/patologia , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Estudos Prospectivos
6.
Radiology ; 303(2): 361-370, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35166585

RESUMO

Background Most radiologists reporting CT colonography (CTC) do not undergo compulsory performance accreditation, potentially lowering diagnostic sensitivity. Purpose To determine whether 1-day individualized training in CTC reporting improves diagnostic sensitivity of experienced radiologists for 6-mm or larger lesions, the durability of any improvement, and any associated factors. Materials and Methods This prospective, multicenter cluster-randomized controlled trial was performed in National Health Service hospitals in England and Wales between April 2017 and January 2020. CTC services were cluster randomized into intervention (1-day training plus feedback) or control (no training or feedback) arms. Radiologists in the intervention arm attended a 1-day workshop focusing on CTC reporting pitfalls with individualized feedback. Radiologists in the control group received no training. Sensitivity for 6-mm or larger lesions was tested at baseline and 1, 6, and 12 months thereafter via interpretation of 10 CTC scans at each time point. The primary outcome was the mean difference in per-lesion sensitivity between arms at 1 month, analyzed using multilevel regression after adjustment for baseline sensitivity. Secondary outcomes included per-lesion sensitivity at 6- and 12-month follow-up, sensitivity for flat neoplasia, and effect of prior CTC experience. Results A total of 69 hospitals were randomly assigned to the intervention (31 clusters, 80 radiologists) or control (38 clusters, 59 radiologists) arm. Radiologists were experienced (median, 500-999 CTC scans interpreted) and reported CTC scans routinely (median, 151-200 scans per year). One-month sensitivity improved after intervention (66.4% [659 of 992]) compared with sensitivity in the control group (42.4% [278 of 655]; difference = 20.8%; 95% CI: 14.6, 27.0; P < .001). Improvements were maintained at 6 (66.4% [572 of 861] vs 50.5% [283 of 560]; difference = 13.0%; 95% CI: 7.4, 18.5; P < .001) and 12 (63.7% [310 of 487] vs 44.4% [187 of 421]; difference = 16.7%; 95% CI: 10.3, 23.1; P < .001) months. This beneficial effect applied to flat lesions (difference = 22.7%; 95% CI: 15.5, 29.9; P < .001) and was independent of career experience (≥1500 CTC scans: odds ratio = 1.09; 95% CI: 0.88, 1.36; P = .22). Conclusion For radiologists evaluating CT colonography studies, a 1-day training intervention yielded sustained improvement in detection of clinically relevant colorectal neoplasia, independent of previous career experience. Clinical trial registration no. NCT02892721 © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Pickhardt in this issue. An earlier incorrect version appeared online and in print. This article was corrected on February 28, 2022.


Assuntos
Colonografia Tomográfica Computadorizada , Neoplasias Colorretais , Colonografia Tomográfica Computadorizada/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Detecção Precoce de Câncer , Humanos , Estudos Prospectivos , Medicina Estatal
7.
Abdom Radiol (NY) ; 46(1): 144-155, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32564208

RESUMO

PURPOSE: To evaluate the utility of mural and extramural sonographic features of Crohn's Disease as potential imaging biomarkers of inflammation and fibrosis against whole-mount histological sections. METHODS: Twelve Crohn's disease patients (Mean age 35(25-69), 7 males) underwent small bowel ultrasound prior to small bowel resection. Two radiologists in consensus graded multiple parameters including mural, mucosal and submucosal thickness, submucosal/mesenteric echogenicity and clarity and mural Doppler signal in 50 selected bowel cross-sections. Matching with histological sampling sites was facilitated via scanning of the resected specimen. A histopathologist scored acute and chronic inflammation, and fibrosis (using histological scoring systems) following analysis of whole mount block sections. The association between sonographic observations and histopathological scores was examined via univariable and multivariable analysis. RESULTS: In univariate analyses, bowel wall thickness (regression co-efficient and 95% CI 0.8 (0.3, 1.3) p = 0.001), mesenteric fat echogenicity (8.7(3.0, 14.5) p = 0.005), submucosal layer thickness (7.4(1.2, 13.5) p = 0.02), submucosal layer clarity (4.4(0.6, 8.2) p = 0.02) and mucosal layer thickness (4.6(1.8, 7.4) p = 0.001) were all significantly associated with acute inflammation. Mesenteric fat echogenicity (674(8.67, 52404) p = 0.009), submucosal layer thickness (79.9(2.16, 2951) p = 0.02) and mucosal layer thickness (13.6(1.54, 121) p = 0.02) were significantly associated with chronic inflammation. Submucosal layer echogenicity (p = 0.03), clarity (25.0(1.76, 356) p = 0.02) and mucosal layer thickness (53.8(3.19, 908) p = 0.006) were significantly associated with fibrosis. In multivariate analyses, wall and mucosal thickness remained significantly associated with acute inflammation (p = 0.02), mesenteric fat echogenicity with chronic inflammation (p = 0.009) and mucosal thickness (p = 0.006) with fibrosis. CONCLUSION: Multiple sonographic parameters are associated with histological phenotypes in Crohn's disease although there is overlap between ultrasonic stigmata of acute inflammation, chronic inflammation and fibrosis.


Assuntos
Doença de Crohn , Adulto , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Fibrose , Humanos , Inflamação/diagnóstico por imagem , Inflamação/patologia , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Masculino , Ultrassonografia
8.
Abdom Radiol (NY) ; 45(10): 3036-3045, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32037466

RESUMO

PURPOSE: To prospectively evaluate interobserver agreement for small bowel ultrasound (SBUS) in newly diagnosed and relapsing Crohn's disease. METHODS: A subset of patients recruited to a prospective trial comparing the diagnostic accuracy of MR enterography and SBUS underwent a second SBUS performed by one of a pool of six practitioners, who recorded the presence, activity and location of small bowel and colonic disease. Detailed segmental mural and extra-mural observations were also scored. Interobserver variability was expressed as percentage agreement with a construct reference standard, split by patient cohort, grouping disease as present or absent. Prevalence adjusted bias adjusted kappa (PABAK), and simple percentage agreement between practitioners, irrespective of the reference standard, were calculated. RESULTS: Thirty-eight patients (11 new diagnosis, 27 relapse) were recruited from two sites. Overall percentage agreement for small bowel disease presence against the consensus reference was 82% (52-95% (95%CI)), kappa coefficient (κ) 0.64, (substantial agreement) for new diagnosis and 81%, κ 0.63 (substantial agreement) for the relapsing cohort. Agreement for colonic disease presence was 64%, κ 0.27 (fair agreement) in new diagnosis and 78%,κ 0.56 (moderate agreement) in the relapsing cohort. Simple agreement between practitioners was 84% and 87% for small bowel and colonic disease presence respectively. Practitioners agreed on small bowel disease activity in 24/27 (89%) where both identified disease. Kappa agreement for detailed mural observations ranged from κ 0.00 to 1.00. CONCLUSION: There is substantial practitioner agreement for small bowel disease presence in newly diagnosed and relapsing CD patients, supporting wider dissemination of enteric US.


Assuntos
Doença de Crohn , Ultrassonografia , Doença de Crohn/diagnóstico por imagem , Humanos , Intestino Delgado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Variações Dependentes do Observador , Estudos Prospectivos
9.
Med Ultrason ; 21(3): 299-315, 2019 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-31476211

RESUMO

Transabdominal gastrointestinal ultrasound (GIUS) is unique in its capacity to examine the bowel non-invasively and in its physiological condition, including extra-intestinal features such as the splanchnic vessels, mesentery, omentum and lymph nodes- even at the bedside. Despite this, and its extensive documentation for its usefulness, it has only been fully implemented in a few European countries and expert centres. Therefore, the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) established a GIUS Task Force Group in 2014 consisting of international experts from 9 European countries with the objectives to standardize and promote the use of GIUS in a clinical setting. This is achieved by publishing clinical guidelines and recommendations on indications and use of GIUS and so far,4 guidelines have been published: first on "examination techniques and normal findings", second on "inflammatory bowel disease", third on "acute appendicitis and diverticulitis" and fourth on "transrectal and perineal ultrasound".This paper describes the ultrasound features of miscellaneous disorders such as celiac disease, cystic fibrosis, omental infarction, Meckel's diverticle, endometriosis, intestinal neoplasia, mucocele, amyloidosis, GVHD, foreign bodies, vasculitis, and pneumatosis cystoides intestinalis. Bowel ultrasound can be indicated in most of these conditions to investigate intestinal symptoms but in other cases the alterations of the bowel can be also an incidental finding that suggest other examinations which finally help to discover an unknown pathological condition.


Assuntos
Gastroenteropatias/diagnóstico por imagem , Ultrassonografia/métodos , Europa (Continente) , Trato Gastrointestinal/diagnóstico por imagem , Humanos , Sociedades Médicas
10.
Health Technol Assess ; 23(42): 1-162, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31432777

RESUMO

BACKGROUND: Magnetic resonance enterography and enteric ultrasonography are used to image Crohn's disease patients. Their diagnostic accuracy for presence, extent and activity of enteric Crohn's disease was compared. OBJECTIVE: To compare diagnostic accuracy, observer variability, acceptability, diagnostic impact and cost-effectiveness of magnetic resonance enterography and ultrasonography in newly diagnosed or relapsing Crohn's disease. DESIGN: Prospective multicentre cohort study. SETTING: Eight NHS hospitals. PARTICIPANTS: Consecutive participants aged ≥ 16 years, newly diagnosed with Crohn's disease or with established Crohn's disease and suspected relapse. INTERVENTIONS: Magnetic resonance enterography and ultrasonography. MAIN OUTCOME MEASURES: The primary outcome was per-participant sensitivity difference between magnetic resonance enterography and ultrasonography for small bowel Crohn's disease extent. Secondary outcomes included sensitivity and specificity for small bowel Crohn's disease and colonic Crohn's disease extent, and sensitivity and specificity for small bowel Crohn's disease and colonic Crohn's disease presence; identification of active disease; interobserver variation; participant acceptability; diagnostic impact; and cost-effectiveness. RESULTS: Out of the 518 participants assessed, 335 entered the trial, with 51 excluded, giving a final cohort of 284 (133 and 151 in new diagnosis and suspected relapse cohorts, respectively). Across the whole cohort, for small bowel Crohn's disease extent, magnetic resonance enterography sensitivity [80%, 95% confidence interval (CI) 72% to 86%] was significantly greater than ultrasonography sensitivity (70%, 95% CI 62% to 78%), with a 10% difference (95% CI 1% to 18%; p = 0.027). For small bowel Crohn's disease extent, magnetic resonance enterography specificity (95%, 95% CI 85% to 98%) was significantly greater than ultrasonography specificity (81%, 95% CI 64% to 91%), with a 14% difference (95% CI 1% to 27%). For small bowel Crohn's disease presence, magnetic resonance enterography sensitivity (97%, 95% CI 91% to 99%) was significantly greater than ultrasonography sensitivity (92%, 95% CI 84% to 96%), with a 5% difference (95% CI 1% to 9%). For small bowel Crohn's disease presence, magnetic resonance enterography specificity was 96% (95% CI 86% to 99%) and ultrasonography specificity was 84% (95% CI 65% to 94%), with a 12% difference (95% CI 0% to 25%). Test sensitivities for small bowel Crohn's disease presence and extent were similar in the two cohorts. For colonic Crohn's disease presence in newly diagnosed participants, ultrasonography sensitivity (67%, 95% CI 49% to 81%) was significantly greater than magnetic resonance enterography sensitivity (47%, 95% CI 31% to 64%), with a 20% difference (95% CI 1% to 39%). For active small bowel Crohn's disease, magnetic resonance enterography sensitivity (96%, 95% CI 92% to 99%) was significantly greater than ultrasonography sensitivity (90%, 95% CI 82% to 95%), with a 6% difference (95% CI 2% to 11%). There was some disagreement between readers for both tests. A total of 88% of participants rated magnetic resonance enterography as very or fairly acceptable, which is significantly lower than the percentage (99%) of participants who did so for ultrasonography. Therapeutic decisions based on magnetic resonance enterography alone and ultrasonography alone agreed with the final decision in 122 out of 158 (77%) cases and 124 out of 158 (78%) cases, respectively. There were no differences in costs or quality-adjusted life-years between tests. LIMITATIONS: Magnetic resonance enterography and ultrasonography scans were interpreted by practitioners blinded to clinical data (but not participant cohort), which does not reflect use in clinical practice. CONCLUSIONS: Magnetic resonance enterography has higher accuracy for detecting the presence, extent and activity of small bowel Crohn's disease than ultrasonography does. Both tests have variable interobserver agreement and are broadly acceptable to participants, although ultrasonography produces less participant burden. Diagnostic impact and cost-effectiveness are similar. Recommendations for future work include investigation of the comparative utility of magnetic resonance enterography and ultrasonography for treatment response assessment and investigation of non-specific abdominal symptoms to confirm or refute Crohn's disease. TRIAL REGISTRATION: Current Controlled Trials ISRCTN03982913. FUNDING: This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 23, No. 42. See the NIHR Journals Library website for further project information.


Crohn's disease is a waxing and waning lifelong inflammatory condition that affects the colon (large bowel) and small bowel. Treatment relies on accurately determining disease extent and underlying inflammation. Colonoscopy is very good for examining the colon, but it is invasive and, at best, can only visualise a few centimetres of the small bowel, so radiological imaging is very important. Magnetic resonance enterography (a type of magnetic resonance imaging scan) and ultrasonography are both radiological tests commonly performed in the NHS, and it is unclear which method is better. We performed a study to compare the accuracy of magnetic resonance enterography and ultrasonography for determining the extent of Crohn's disease in the bowel of participants newly diagnosed and in those participants with established Crohn's disease but with suspected deterioration. We also investigated how often radiologists agree with each other during test interpretation, the participant experience of undergoing the tests and their cost-effectiveness. We compared the tests in 284 participants (133 newly diagnosed and 151 with suspected deterioration). We found that both tests were accurate for detecting the presence (97% for magnetic resonance enterography and 92% for ultrasonography) and location (80% for magnetic resonance enterography and 70% for ultrasonography) of disease in the small bowel, but magnetic resonance enterography was better than ultrasonography for both (correctly classifying disease extent in 107 more participants for every 1000 participants with Crohn's disease). Magnetic resonance enterography was similarly better than ultrasonography at determining if the bowel was inflamed. The results were similar in newly diagnosed participants and those participants with suspected deterioration. Agreement between radiologists interpreting the same images was, at best, moderate for both tests. A total of 88% of participants tolerated magnetic resonance enterography well or fairly well, which was less than the percentage (99%) of participants who tolerated ultrasonography well or fairly well. Both tests had a similar effect on the treatment decisions made by doctors. Both tests were also similar in their value for money for the NHS.


Assuntos
Análise Custo-Benefício , Doença de Crohn/diagnóstico por imagem , Imageamento por Ressonância Magnética , Ultrassonografia , Adolescente , Adulto , Feminino , Humanos , Intestino Delgado , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Sensibilidade e Especificidade , Reino Unido , Adulto Jovem
12.
Ultraschall Med ; 40(2): 163-175, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30616263

RESUMO

An interdisciplinary task force of European experts summarizes the value of gastrointestinal ultrasound (GIUS) in the management of acute appendicitis and diverticulitis. Based on an extensive literature review, clinical recommendations for these highly common diseases in visceral medicine are presented.In patients with acute appendicitis, preoperative sonography has been established as a routine procedure in most European countries for medical and legal reasons. Routine sonography in these patients may reduce the rate of unnecessary surgery by half. The sensitivity, specificity, and accuracy of ultrasound reach values above 90 % and are equivalent to CT and MRI. However, the high operator dependence may be a problem, for example in point-of-care ultrasound in emergency departments. Structured training programs, quality controls and standardized ultrasound reporting should be increasingly implemented.In the case of suspected acute diverticulitis, "ultrasound first" should also be a basic element in the approach to all patients. Sonography can confirm the diagnosis and allows early risk stratification. As treatment strategies have become less aggressive and more tailored to the stage of diverticulitis, accurate staging has become increasingly important. GIUS and CT have proven to have similar sensitivity and specificity. Especially in cases of uncomplicated diverticulitis, GIUS will be the one and only imaging procedure. CT may work as a backup and has particular advantages for diverticulitis located in the distal sigmoid, inflammation deep in the small pelvis and insufficient ultrasound scanning conditions. This step-up approach (ultrasound first and CT only in case of a negative or inconclusive ultrasound result) has proven to yield the best accuracy.


Assuntos
Apendicite , Diverticulite , Doença Aguda , Apendicite/diagnóstico por imagem , Diverticulite/diagnóstico por imagem , Europa (Continente) , Humanos , Tomografia Computadorizada por Raios X , Ultrassonografia
13.
Lancet Gastroenterol Hepatol ; 3(8): 548-558, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29914843

RESUMO

BACKGROUND: Magnetic resonance enterography (MRE) and ultrasound are used to image Crohn's disease, but their comparative accuracy for assessing disease extent and activity is not known with certainty. Therefore, we did a multicentre trial to address this issue. METHODS: We recruited patients from eight UK hospitals. Eligible patients were 16 years or older, with newly diagnosed Crohn's disease or with established disease and suspected relapse. Consecutive patients had MRE and ultrasound in addition to standard investigations. Discrepancy between MRE and ultrasound for the presence of small bowel disease triggered an additional investigation, if not already available. The primary outcome was difference in per-patient sensitivity for small bowel disease extent (correct identification and segmental localisation) against a construct reference standard (panel diagnosis). This trial is registered with the International Standard Randomised Controlled Trial, number ISRCTN03982913, and has been completed. FINDINGS: 284 patients completed the trial (133 in the newly diagnosed group, 151 in the relapse group). Based on the reference standard, 233 (82%) patients had small bowel Crohn's disease. The sensitivity of MRE for small bowel disease extent (80% [95% CI 72-86]) and presence (97% [91-99]) were significantly greater than that of ultrasound (70% [62-78] for disease extent, 92% [84-96] for disease presence); a 10% (95% CI 1-18; p=0·027) difference for extent, and 5% (1-9; p=0·025) difference for presence. The specificity of MRE for small bowel disease extent (95% [85-98]) was significantly greater than that of ultrasound (81% [64-91]); a difference of 14% (1-27; p=0·039). The specificity for small bowel disease presence was 96% (95% CI 86-99) with MRE and 84% (65-94) with ultrasound (difference 12% [0-25]; p=0·054). There were no serious adverse events. INTERPRETATION: Both MRE and ultrasound have high sensitivity for detecting small bowel disease presence and both are valid first-line investigations, and viable alternatives to ileocolonoscopy. However, in a national health service setting, MRE is generally the preferred radiological investigation when available because its sensitivity and specificity exceed ultrasound significantly. FUNDING: National Institute of Health and Research Health Technology Assessment.


Assuntos
Doença de Crohn/diagnóstico por imagem , Intestino Delgado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Ultrassonografia , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Sensibilidade e Especificidade , Adulto Jovem
14.
Health Technol Assess ; 22(7): 1-114, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29402376

RESUMO

BACKGROUND: Pancreatic cancer diagnosis and staging can be difficult in 10-20% of patients. Positron emission tomography (PET)/computed tomography (CT) adds precise anatomical localisation to functional data. The use of PET/CT may add further value to the diagnosis and staging of pancreatic cancer. OBJECTIVE: To determine the incremental diagnostic accuracy and impact of PET/CT in addition to standard diagnostic work-up in patients with suspected pancreatic cancer. DESIGN: A multicentre prospective diagnostic accuracy and clinical value study of PET/CT in suspected pancreatic malignancy. PARTICIPANTS: Patients with suspected pancreatic malignancy. INTERVENTIONS: All patients to undergo PET/CT following standard diagnostic work-up. MAIN OUTCOME MEASURES: The primary outcome was the incremental diagnostic value of PET/CT in addition to standard diagnostic work-up with multidetector computed tomography (MDCT). Secondary outcomes were (1) changes in patients' diagnosis, staging and management as a result of PET/CT; (2) changes in the costs and effectiveness of patient management as a result of PET/CT; (3) the incremental diagnostic value of PET/CT in chronic pancreatitis; (4) the identification of groups of patients who would benefit most from PET/CT; and (5) the incremental diagnostic value of PET/CT in other pancreatic tumours. RESULTS: Between 2011 and 2013, 589 patients with suspected pancreatic cancer underwent MDCT and PET/CT, with 550 patients having complete data and in-range PET/CT. Sensitivity and specificity for the diagnosis of pancreatic cancer were 88.5% and 70.6%, respectively, for MDCT and 92.7% and 75.8%, respectively, for PET/CT. The maximum standardised uptake value (SUVmax.) for a pancreatic cancer diagnosis was 7.5. PET/CT demonstrated a significant improvement in relative sensitivity (p = 0.01) and specificity (p = 0.023) compared with MDCT. Incremental likelihood ratios demonstrated that PET/CT significantly improved diagnostic accuracy in all scenarios (p < 0.0002). PET/CT correctly changed the staging of pancreatic cancer in 56 patients (p = 0.001). PET/CT influenced management in 250 (45%) patients. PET/CT stopped resection in 58 (20%) patients who were due to have surgery. The benefit of PET/CT was limited in patients with chronic pancreatitis or other pancreatic tumours. PET/CT was associated with a gain in quality-adjusted life-years of 0.0157 (95% confidence interval -0.0101 to 0.0430). In the base-case model PET/CT was seen to dominate MDCT alone and is thus highly likely to be cost-effective for the UK NHS. PET/CT was seen to be most cost-effective for the subgroup of patients with suspected pancreatic cancer who were thought to be resectable. CONCLUSION: PET/CT provided a significant incremental diagnostic benefit in the diagnosis of pancreatic cancer and significantly influenced the staging and management of patients. PET/CT had limited utility in chronic pancreatitis and other pancreatic tumours. PET/CT is likely to be cost-effective at current reimbursement rates for PET/CT to the UK NHS. This was not a randomised controlled trial and therefore we do not have any information from patients who would have undergone MDCT only for comparison. In addition, there were issues in estimating costs for PET/CT. Future work should evaluate the role of PET/CT in intraductal papillary mucinous neoplasm and prognosis and response to therapy in patients with pancreatic cancer. STUDY REGISTRATION: Current Controlled Trials ISRCTN73852054 and UKCRN 8166. FUNDING: The National Institute for Health Research Health Technology Assessment programme.


Assuntos
Carcinoma Ductal Pancreático/diagnóstico , Carcinoma Ductal Pancreático/patologia , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/economia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Ductal Pancreático/diagnóstico por imagem , Análise Custo-Benefício , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Econométricos , Tomografia Computadorizada Multidetectores/economia , Tomografia Computadorizada Multidetectores/métodos , Estadiamento de Neoplasias , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/terapia , Pancreatite Crônica/diagnóstico , Pancreatite Crônica/patologia , Estudos Prospectivos , Anos de Vida Ajustados por Qualidade de Vida , Sensibilidade e Especificidade , Medicina Estatal , Reino Unido , Adulto Jovem
15.
BMC Gastroenterol ; 14: 142, 2014 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-25110044

RESUMO

BACKGROUND: Crohn's disease (CD) is a lifelong, relapsing and remitting inflammatory condition of the intestine. Medical imaging is crucial for diagnosis, phenotyping, activity assessment and detecting complications. Diverse small bowel imaging tests are available but a standard algorithm for deployment is lacking. Many hospitals employ tests that impart ionising radiation, of particular concern to this young patient population. Magnetic resonance enterography (MRE) and small bowel ultrasound (USS) are attractive options, as they do not use ionising radiation. However, their comparative diagnostic accuracy has not been compared in large head to head trials. METRIC aims to compare the diagnostic efficacy, therapeutic impact and cost effectiveness of MRE and USS in newly diagnosed and relapsing CD. METHODS: METRIC (ISRCTN03982913) is a multicentre, non-randomised, single-arm, prospective comparison study. Two patient cohorts will be recruited; those newly diagnosed with CD, and those with suspected relapse. Both will undergo MRE and USS in addition to other imaging tests performed as part of clinical care. Strict blinding protocols will be enforced for those interpreting MRE and USS. The Harvey Bradshaw index, C-reactive protein and faecal calprotectin will be collected at recruitment and 3 months, and patient experience will be assessed via questionnaires. A multidisciplinary consensus panel will assess all available clinical and imaging data up to 6 months after recruitment of each patient and will define the standard of reference for the presence, localisation and activity of disease against which the diagnostic accuracy of MRE and USS will be judged. Diagnostic impact of MRE and USS will be evaluated and cost effectiveness will be assessed. The primary outcome measure is the difference in per patient sensitivity between MRE and USS for the correct identification and localisation of small bowel CD. DISCUSSION: The trial is open at 5 centres with 46 patients recruited. We highlight the importance of stringent blinding protocols in order to delineate the true diagnostic accuracy of both imaging tests and discuss the difficulties of diagnostic accuracy studies in the absence of a single standard of reference, describing our approach utilising a consensus panel whilst minimising incorporation bias. TRIAL REGISTRATION: METRIC - ISRCTN03982913 - 05.11.13.


Assuntos
Doença de Crohn/diagnóstico , Intestino Delgado/diagnóstico por imagem , Adolescente , Adulto , Idoso , Estudos de Coortes , Análise Custo-Benefício , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Humanos , Intestino Delgado/patologia , Imageamento por Ressonância Magnética/economia , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Ultrassonografia/economia , Adulto Jovem
16.
Eur Radiol ; 24(9): 2309-18, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25001085

RESUMO

OBJECTIVES: To assess the cross-centre consistency of iodine enhancement, contrast-to-noise ratio and radiation dose in a multicentre perfusion CT trial of colorectal cancer. MATERIALS AND METHODS: A cylindrical water phantom containing different iodine inserts was examined on seven CT models in 13 hospitals. The relationship between CT number (Hounsfield units, HU) and iodine concentration (milligrams per millilitre) was established and contrast-to-noise ratios (CNRs) calculated. Radiation doses (CTDIvol, DLP) were compared across all sites. RESULTS: There was a linear relationship between CT number and iodine density. Iodine enhancement varied by a factor of at most 1.10, and image noise by at most 1.5 across the study sites. At an iodine concentration of 1 mg ml(-1) and 100 kV, CNRs ranged from 3.6 to 4.8 in the 220-mm phantom and from 1.4 to 1.9 in the 300-mm phantom. Doses varied by a factor of at most 2.4, but remained within study dose constraints. Iterative reconstruction algorithms did not alter iodine enhancement but resulted in reduced image noise by a factor of at most 2.2, allowing a potential dose decrease of at most 80% compared to filtered back projection (FBP). CONCLUSIONS: Quality control of CT performance across centres indicates that CNR values remain relatively consistent across all sites, giving acceptable image quality within the agreed dose constraints. KEY POINTS: Quality control is essential in a multicentre setting to enable CT quantification. CNRs in a body-sized phantom had the recommended value of at least 1.5. CTDIs and DLPs varied by factors of 1.8 and 2.4 respectively.


Assuntos
Algoritmos , Neoplasias Colorretais/diagnóstico por imagem , Iodo , Imagens de Fantasmas , Controle de Qualidade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Doses de Radiação , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA