RESUMO
Introduction: Tumour Mutation Burden (TMB) is a potential biomarker for immune cancer therapies. Here we investigated parameters that might affect TMB using duplicate cytology smears obtained from endobronchial ultrasound transbronchial needle aspiration (EBUS TBNA)-sampled malignant lymph nodes. Methods: Individual Diff-Quik cytology smears were prepared for each needle pass. DNA extracted from each smear underwent sequencing using large gene panel (TruSight Oncology 500 (TSO500 - Illumina)). TMB was estimated using the TSO500 Local App v. 2.0 (Illumina). Results: Twenty patients had two or more Diff-Quik smears (total 45 smears) which passed sequencing quality control. Average smear TMB was 8.7 ± 5.0 mutations per megabase (Mb). Sixteen of the 20 patients had paired samples with minimal differences in TMB score (average difference 1.3 ± 0.85). Paired samples from 13 patients had concordant TMB (scores below or above a threshold of 10 mutations/Mb). Markedly discrepant TMB was observed in four cases, with an average difference of 11.3 ± 2.7 mutations/Mb. Factors affecting TMB calling included sample tumour content, the amount of DNA used in sequencing, and bone fide heterogeneity of node tumour between paired samples. Conclusion: TMB assessment is feasible from EBUS-TBNA smears from a single needle pass. Repeated samples of a lymph node station have minimal variation in TMB in most cases. However, this novel data shows how tumour content and minor change in site of node sampling can impact TMB. Further study is needed on whether all node aspirates should be combined in 1 sample, or whether testing independent nodes using smears is needed.
RESUMO
INTRODUCTION: Maximising alternative sample types for genomics in advanced lung cancer is important because bronchoscopic samples may sometimes be insufficient for this purpose. Further, the clinical applications of comprehensive molecular analysis such as whole genome sequencing (WGS) are rapidly developing. Diff-Quik cytology smears from EBUS TBNA is an alternative source of DNA, but its feasibility for WGS has not been previously demonstrated. METHODS: Diff-Quik smears were collected along with research cell pellets. RESULTS: Tumour content of smears were compared to research cell pellets from 42 patients, which showed good correlation (Spearman correlation 0.85, P < 0.0001). A subset of eight smears underwent WGS, which presented similar mutation profiles to WGS of the matched cell pellet. DNA yield was predicted using a regression equation of the smears cytology features, which correctly predicted DNA yield > 1500 ng in 7 out of 8 smears. CONCLUSIONS: WGS of commonly collected Diff-Quik slides is feasible and their DNA yield can be predicted.
Assuntos
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patologia , Biópsia por Agulha Fina , Endossonografia , Sequenciamento Completo do Genoma , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Broncoscopia , Linfonodos/patologiaRESUMO
BACKGROUND: Cytology smears are commonly collected during endobronchial ultrasound-guided transbronchial needle aspiration (EBUS TBNA) procedures but are rarely used for molecular testing. Studies are needed to demonstrate their great potential, in particular for the prediction of malignant cell DNA content and for utility in molecular diagnostics using large gene panels. METHODS: A prospective study was performed on samples from 66 patients with malignant lymph nodes who underwent EBUS TBNA. All patients had air-dried, Diff-Quik cytology smears and formalin-fixed, paraffin-embedded cell blocks collected for cytopathology and molecular testing. One hundred eighty-five smears were evaluated by microscopy to estimate malignant cell percentage and abundance and to calculate smear size and were subjected to DNA extraction. DNA from 56 smears from 27 patients was sequenced with the TruSight Oncology 500 assay (Illumina). RESULTS: Each microscopy parameter had a significant effect on the DNA yield. An algorithm was developed that predicted a >50-ng DNA yield of a smear with an area under the curve of 0.86. Fifty DNA samples (89%) with varying malignant yields were successfully sequenced. Low-malignant-cell content (<25%) and smear area (<15%) were the main reasons for failure. All standard-of-care mutations were detected in replicate smears from individual patients, regardless of malignant cell content. Tier 1/2 mutations were discovered in two cases where standard-of-care specimens were inadequate for sequencing. Smears were scored for tumor mutation burden. CONCLUSIONS: Microscopy of Diff-Quik smears can triage samples for comprehensive panel sequencing, which highlights smears as an excellent alternative to traditional testing with cell blocks.
Assuntos
Neoplasias Pulmonares , Humanos , Estudos Prospectivos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patologia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Mutação , Linfonodos/patologiaRESUMO
Introduction: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS TBNA) is an important means of obtaining a tissue for advanced lung cancer. Optimizing the EBUS TBNA needling technique is important to maintain procedural simplicity and maximize sample quality for emerging molecular diagnostics. Methods: We prospectively explored three versus 10 agitations of the needle in sequential passes into the lymph node using separate needles. Resulting Diff-Quik cytology smears were quantitatively assessed using microscopic (tumor cell cellularity, abundance scores, erythrocyte contamination) and DNA yields. Microscopy was reported by two cytopathologists, and an inter-rater assessment was made by four additional cytopathologists. Results: In 86 patients confirmed as having malignant disease by EBUS TBNA (45 males, 41 females), a mean of 5.3 smears were made per patient with a total of 459 smears scored by pathologists and 168 paired smears extracted for DNA. There was no significant difference between three versus 10 agitations for smear cellularity (p = 0.44), DNA yield (p = 0.84), or DNA integrity (p = 0.20), but there was significantly less contamination by erythrocytes from three agitations (chi-square p = 0.008). There was significantly more DNA in the first pass into the node using three agitations than with other passes and with 10 agitations (pass × agitations interaction, p = 0.031). Reviewing pathologists correctly classified smears as more than or equal to 25% cellularity 86.3% of the time (κ = 0.63 [95% confidence interval: 0.55-0.71]). Conclusions: Three agitations are noninferior to 10 agitations for overall abundance of malignant cells and DNA content on smears. A smear with adequate DNA for panel sequencing could almost always be made with the first needle pass using three agitations.
RESUMO
Iron is typically the dominant metal in the ultrafine fraction of airborne particulate matter. Various studies have investigated the toxicity of inhaled nano-sized iron oxide particles (FeOxNPs) but their results have been contradictory, with some indicating no or minor effects and others finding effects including oxidative stress and inflammation. Most studies, however, did not use materials reflecting the characteristics of FeOxNPs present in the environment. We, therefore, analysed the potential toxicity of FeOxNPs of different forms (Fe3O4, α-Fe2O3 and γ-Fe2O3) reflecting the characteristics of high iron content nano-sized particles sampled from the environment, both individually and in a mixture (FeOx-mix). A preliminary in vitro study indicated Fe3O4 and FeOx-mix were more cytotoxic than either form of Fe2O3 in human bronchial epithelial cells (BEAS-2B). Follow-up in vitro (0.003, 0.03, 0.3 µg/mL, 24 h) and in vivo (Sprague-Dawley rats, nose-only exposure, 50 µg/m3 and 500 µg/m3, 3 h/d × 3 d) studies therefore focused on these materials. Experiments in vitro explored responses at the molecular level via multi-omics analyses at concentrations below those at which significant cytotoxicity was evident to avoid detection of responses secondary to toxicity. Inhalation experiments used aerosol concentrations chosen to produce similar levels of particle deposition on the airway surface as were delivered in vitro. These were markedly higher than environmental concentrations. No clinical signs of toxicity were seen nor effects on BALF cell counts or LDH levels. There were also no significant changes in transcriptomic or metabolomic responses in lung or BEAS-2B cells to suggest adverse effects.
Assuntos
Lesão Pulmonar Aguda/fisiopatologia , Inflamação/fisiopatologia , Pulmão/efeitos dos fármacos , Nanopartículas Magnéticas de Óxido de Ferro/toxicidade , Lesão Pulmonar Aguda/induzido quimicamente , Aerossóis/química , Aerossóis/toxicidade , Poluentes Atmosféricos/toxicidade , Animais , Linhagem Celular , Humanos , Inflamação/induzido quimicamente , Exposição por Inalação , Pulmão/patologia , Material Particulado/toxicidade , Ratos , Ratos Sprague-DawleyRESUMO
Epidemiological studies have shown that the main risk arising from exposure to plutonium aerosols is lung cancer, with other detrimental effects in the bone and liver. A realistic assessment of these risks, in turn, depends on the accuracy of the dosimetric models used to calculate doses in such studies. A state-of-the-art biokinetic model for plutonium, based on the current International Commission on Radiological Protection biokinetic model, has been developed for this purpose in an epidemiological study involving the plutonium exposure of Mayak workers in Ozersk, Russia. One important consequence of this model is that the lung dose is extremely sensitive to the fraction (fb) of plutonium, which becomes bound to lung tissue after it dissolves. It has been shown that if just 1% of the material becomes bound in the bronchial region, this will double the lung dose. Furthermore, fb is very difficult to quantify from experimental measurements. This paper summarizes the work carried out thus far to quantify fb. Bayesian techniques have been used to analyze data from different sources, including both humans and dogs, and the results suggest a small, but nonzero, fraction of < 1%. A Bayesian analysis of 20 Mayak workers exposed to plutonium nitrate suggests an fb between 0 and 0.3%. Based on this work, the International Commission on Radiological Protection is currently considering the adoption of a value of 0.2% for the default bound fraction for all actinides in its forthcoming recommendations on internal dosimetry. In an attempt to corroborate these findings, further experimental work has been carried out by the US Transuranium and Uranium Registries. This work has involved direct measurements of plutonium in the respiratory tract tissues of workers who have been exposed to soluble plutonium nitrate. Without binding, one would not expect to see any activity remaining in the lungs at long times after exposure since it would have been cleared by the natural process of mucociliary clearance. Further supportive study of workers exposed to plutonium oxide is planned. This paper ascertains the extent to which these results corroborate previous inferences concerning the bound fraction.
Assuntos
Teorema de Bayes , Pulmão/metabolismo , Modelos Biológicos , Exposição Ocupacional/análise , Plutônio/análise , Animais , Cães , Humanos , Pulmão/efeitos da radiação , Plutônio/farmacocinética , Doses de Radiação , Distribuição TecidualRESUMO
This paper presents a review and analysis of available data on background levels of polonium-210 in urine. It was established that 819 measurements could be considered to correspond to natural background levels, excluding a large number of values identified by the original investigators as potentially due to an artificial source or due to recognised enhancement of dietary intake. Almost 550 measurements were extracted from studies reported in the literature; additional measurements were contributions of previously unpublished data by authors of more recent papers. The majority of the measurements (462) were single samples from individuals but 357 values were repeat measurements provided by 81 subjects and for these the mean value for each subject was used. The final dataset consisted of measurements from 543 individuals. Analysis of the measurements confirmed the data was log normally distributed with mean and median values of 15.5 mBq d-1 and 11 mBq d-1 in urine samples, respectively. While the overall range was from 0.3-111 mBq d-1, almost 90% of the measurements were less than 30 mBq d-1, 95% were less than 45 mBq d-1, and 99% less than 70 mBq d-1. Separate analysis of data for smokers and non-smokers suggested a modest increase in smokers of up to 5 mBq d-1. Perhaps reflecting the importance of dietary differences such as seafood consumption, a marked difference between countries was observed in the range of results. While for most countries, 95% or more of results were below 30 mBq d-1, China and Italy were notable exceptions, with greater than 20% of values above this level.
Assuntos
Polônio/urina , Dieta , Humanos , Fumar/urinaRESUMO
Mr Litvinenko died on 23 November 2006, having been poisoned with polonium-210 on 1 November, with evidence of a previous poisoning attempt during October 2006. Measurements of 210Po in urine samples were made for a large number of people to determine whether they may have been contaminated. In the majority of cases, measured levels were attributable to the presence of 210Po from normal dietary sources. For a small number of cases, elevated levels provided evidence of direct contamination associated with the poisonings. For one individual, while estimated doses were below thresholds for irreversible organ damage, a notably increased risk of cancer can be inferred. The use of the chelating agent, unithiol, to increase 210Po excretion in this case was only moderately effective in reducing doses received.
Assuntos
Síndrome Aguda da Radiação/diagnóstico , Monitoramento Ambiental/métodos , Homicídio , Polônio/intoxicação , Monitoramento Epidemiológico , Pessoas Famosas , Humanos , Londres , Masculino , Exposição Ocupacional , Logradouros Públicos , Doses de Radiação , Distribuição TecidualRESUMO
Rapid on-site evaluation (ROSE) of endobronchial ultrasound-guided transbronchial needle aspirates (EBUS-TBNA) has not been compared to final detailed cytological analysis in patients with suspected sarcoidosis. To assess the diagnostic accuracy of EBUS-TBNA with ROSE in patients with suspected sarcoidosis, a prospective two-centre study performed EBUS-TBNA with ROSE of cellular material followed by transbronchial lung biopsy (TBLB) and endobronchial biopsy (EBB). The diagnostic accuracy of EBUS-TBNA with ROSE was compared to the final cytological assessment and to TBLB and EBB. Analysis confirmed 49 out of 60 cases of sarcoidosis. ROSE sensitivity was 87.8% (specificity 91%, positive predictive value 97.7%). ROSE slide interpretation in combination with the final fixed slide and cell block preparations had a sensitivity of 91.8% (specificity 100%, positive predictive value 100%). 67% of patients were confirmed as having sarcoidosis on TBLB and 29% on EBB. Interobserver agreement between cytotechnologists and pathologists was very good (κ=0.91, 95% CI 0.80-1.0 and κ=0.91, 95% CI 0.79-1.0, respectively). EBUS-TBNA with ROSE has high diagnostic accuracy and interobserver agreement and informs the bronchoscopist in theatre whether additional diagnostic procedures need to be undertaken. EBUS-TBNA with ROSE should therefore be considered as the first-line investigation of sarcoidosis.
Assuntos
Brônquios/patologia , Sarcoidose Pulmonar/diagnóstico por imagem , Sarcoidose Pulmonar/diagnóstico , Sarcoidose Pulmonar/patologia , Adulto , Biópsia , Biópsia por Agulha Fina , Broncoscopia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , UltrassonografiaRESUMO
Three new polypropionate metabolites, 6Z,8E-Δ(8)-siphonarienfuranone (1), 6E,8E-Δ(8)-siphonarienfuranone (2), and 6E,8E-3-hydroxy-4,6,8,10,12-pentamethylpentadeca-6,8-dien-5-one (3), and the known polypropionate siphonarienfuranone (4) were isolated from the intertidal South African marine mollusk Siphonaria oculus. Evidence is presented to suggest that 1, 2, and 4 may cyclize from an acylic precursor on chromatographic workup of the acetone extract of this mollusk.
Assuntos
Furanos/isolamento & purificação , Moluscos/química , Polímeros/isolamento & purificação , Propionatos/isolamento & purificação , Animais , Furanos/química , Biologia Marinha , Estrutura Molecular , Polímeros/química , Propionatos/química , África do Sul , EstereoisomerismoAssuntos
Biópsia por Agulha Fina/métodos , Brônquios/diagnóstico por imagem , Brônquios/patologia , Endossonografia/métodos , Neoplasias Pulmonares/patologia , Adulto , Idoso , Biópsia por Agulha Fina/efeitos adversos , Endossonografia/efeitos adversos , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico , Masculino , Pessoa de Meia-Idade , Estadiamento de NeoplasiasRESUMO
This review focuses on the role of endobronchial ultrasound-guided transbronchial needle aspiration in day-to-day pulmonology practice. Case examples are given of the common indications for endobronchial ultrasound-guided transbronchial needle aspiration which are: (i) lung cancer staging; (ii) confirming a diagnosis of malignancy in thoracic lymph nodes; (iii) diagnosing central pulmonary masses; (iv) sarcoidosis; and (v) inflammatory/benign thoracic lymph nodes. The technique is widely used, and after appropriate training by experienced bronchoscopists can be easily integrated into a bronchoscopy service.
Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico , Humanos , Neoplasias Pulmonares/patologia , Estadiamento de Neoplasias , PneumologistasRESUMO
The accidental or deliberate dispersal of radioactive aerosols into the public environment may require urgent assessments of radiation dose to be made to aid decisions on whether treatment should be implemented, or to reassure the public that doses are acceptably low. However, rapid assessments will be difficult due to lack of information on factors such as the particle size distribution and biokinetic characteristics of the aerosol. A procedure is described that relates the amount of activity of a radionuclide in the body and excreta to time after intake for a specified dose, taking into account the likely variations in aerosol size and differences in the biokinetic behaviour of the same or different chemical forms of the radionuclide. The implementation of the procedure for an intake of caesium-137 and a dose level of 1 mSv is described and the information presented graphically. Figures for other specified dose levels can be produced by simply scaling the data by an appropriate factor. The figures can also be used to assess the most appropriate monitoring procedure and indicate the uncertainty in the assessed dose according to the parameter and parameter values used. This approach is proposed for rapid decisions on public reassurance when potentially large numbers of people are involved. It is not intended as a substitute for individual dose assessment.