Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Eur Heart J Cardiovasc Imaging ; 23(2): 229-237, 2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-33982071

RESUMO

AIMS: To compare cardiac magnetic resonance (CMR) measurement of T1 reactivity (ΔT1) with [15O]H2O positron emission tomography (PET) measurements of quantitative myocardial perfusion. METHODS AND RESULTS: Forty-three patients with suspected obstructed coronary artery disease underwent [15O]H2O PET and CMR at 1.5-T, including rest and adenosine stress T1 mapping (ShMOLLI) and late gadolinium enhancement to rule out presence of scar tissue. ΔT1 was determined for the three main vascular territories and compared with [15O]H2O PET-derived regional stress myocardial blood flow (MBF) and myocardial flow reserve (MFR). ΔT1 showed a significant but poor correlation with stress MBF (R2 = 0.04, P = 0.03) and MFR (R2 = 0.07, P = 0.004). Vascular territories with impaired stress MBF (i.e. ≤2.30 mL/min/g) demonstrated attenuated ΔT1 compared with vascular territories with preserved stress MBF (2.9 ± 2.2% vs. 4.1 ± 2.2%, P = 0.008). In contrast, ΔT1 did not differ between vascular territories with impaired (i.e. <2.50) and preserved MFR (3.2 ± 2.6% vs. 4.0 ± 2.1%, P = 0.25). Receiver operating curve analysis of ΔT1 resulted in an area under the curve of 0.66 [95% confidence interval (CI): 0.57-0.75, P = 0.009] for diagnosing impaired stress MBF and 0.62 (95% CI: 0.53-0.71, P = 0.07) for diagnosing impaired MFR. CONCLUSIONS: CMR stress T1 mapping has poor agreement with [15O]H2O PET measurements of absolute myocardial perfusion. Stress T1 and ΔT1 are lower in vascular territories with reduced stress MBF but have poor accuracy for detecting impaired myocardial perfusion.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Meios de Contraste , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Gadolínio , Humanos , Espectroscopia de Ressonância Magnética , Imagem de Perfusão do Miocárdio/métodos , Radioisótopos de Oxigênio , Tomografia por Emissão de Pósitrons/métodos
2.
Eur J Nucl Med Mol Imaging ; 47(7): 1688-1697, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31822958

RESUMO

PURPOSE: To compare cardiac magnetic resonance imaging (CMR) with [15O]H2O positron emission tomography (PET) for quantification of absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) in patients with coronary artery disease (CAD). METHODS: Fifty-nine patients with stable CAD underwent CMR and [15O]H2O PET. The CMR imaging protocol included late gadolinium enhancement to rule out presence of scar tissue and perfusion imaging using a dual sequence, single bolus technique. Absolute MBF was determined for the three main vascular territories at rest and during vasodilator stress. RESULTS: CMR measurements of regional stress MBF and MFR showed only moderate correlation to those obtained using PET (r = 0.39; P < 0.001 for stress MBF and r = 0.36; P < 0.001 for MFR). Bland-Altman analysis revealed a significant bias of 0.2 ± 1.0 mL/min/g for stress MBF and - 0.5 ± 1.2 for MFR. CMR-derived stress MBF and MFR demonstrated area under the curves of respectively 0.72 (95% CI: 0.65 to 0.79) and 0.76 (95% CI: 0.69 to 0.83) and had optimal cutoff values of 2.35 mL/min/g and 2.25 for detecting abnormal myocardial perfusion, defined as [15O]H2O PET-derived stress MBF ≤ 2.3 mL/min/g and MFR ≤ 2.5. Using these cutoff values, CMR and PET were concordant in 137 (77%) vascular territories for stress MBF and 135 (80%) vascular territories for MFR. CONCLUSION: CMR measurements of stress MBF and MFR showed modest agreement to those obtained with [15O]H2O PET. Nevertheless, stress MBF and MFR were concordant between CMR and [15O]H2O PET in 77% and 80% of vascular territories, respectively.


Assuntos
Doença da Artéria Coronariana , Circulação Coronária , Espectroscopia de Ressonância Magnética , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Idoso , Meios de Contraste , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Reserva Fracionada de Fluxo Miocárdico , Gadolínio , Humanos , Espectroscopia de Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/normas , Radioisótopos de Oxigênio , Tomografia por Emissão de Pósitrons/normas , Reprodutibilidade dos Testes
3.
J Magn Reson Imaging ; 49(5): 1391-1399, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30318731

RESUMO

BACKGROUND: Each ultrafast dynamic contrast-enhanced (DCE) MRI sequence for breast cancer generates thousands of images in a 4D stack that need to be reviewed by a radiologist. PURPOSE: To assess whether color intensity projections (CIP) effectively summarizes-using only the time of arrival (ToA) and amount of signal enhancement (AoE) of the contrast agent-the thousands of ultrafast images. STUDY TYPE: Retrospective cohort clinical trial. SUBJECTS: The study included 89 patients who had been scanned with an MRI beast protocol, of which 26 had breast cancer and 63 did not. FIELD STRENGTH/SEQUENCE: The 115-second ultrafast DCE sequence at 3T acquired 19 consecutive frames every 4.26 seconds with 152 slices per frame, yielding a 4D stack with 2888 2D images for each of water and fat. ASSESSMENT: For each slice of the water 4D stack a single CIP image was generated that encoded the ToA in the hue (red, orange, yellow, green, cyan, blue) and AoE in the brightness. Each of three experienced radiologists assigned a Breast Imaging and Reporting Data System (BI-RADS) score for each patient, first using only the CIP images, and subsequently using both CIP and the full 4D stack. STATISTICAL TESTS: The one-sided Fisher's exact test was used to determine statistical significance of both the sensitivity and specificity between the CIP alone and the CIP plus 4D stack. RESULTS: All malignancies were detected using only CIP by at least one of the radiologists. The CIP and CIP+4D sensitivities for reader 1 were 96% and 96% (P = 0.57), specificities were 59% and 65% (P = 0.29). For reader 2, the values were 96% and 100% (P = 0.51) with 62% and 71% (P = 0.17). For reader 3 the values were 92% and 96% (P = 0.50) with 51% and 62% (P = 0.07). DATA CONCLUSION: With a 95% sensitivity, CIP provides an effective summary of ultrafast DCE images of breast cancer. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:1391-1399.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Meios de Contraste , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/diagnóstico por imagem , Estudos de Coortes , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
4.
Sci Rep ; 7(1): 10021, 2017 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-28855717

RESUMO

Surgical reconstruction of cartilaginous defects remains a major challenge. In the current study, we aimed to identify an imaging strategy for the development of patient-specific constructs that aid in the reconstruction of nasal deformities. Magnetic Resonance Imaging (MRI) was performed on a human cadaver head to find the optimal MRI sequence for nasal cartilage. This sequence was subsequently used on a volunteer. Images of both were assessed by three independent researchers to determine measurement error and total segmentation time. Three dimensionally (3D) reconstructed alar cartilage was then additively manufactured. Validity was assessed by comparing manually segmented MR images to the gold standard (micro-CT). Manual segmentation allowed delineation of the nasal cartilages. Inter- and intra-observer agreement was acceptable in the cadaver (coefficient of variation 4.6-12.5%), but less in the volunteer (coefficient of variation 0.6-21.9%). Segmentation times did not differ between observers (cadaver P = 0.36; volunteer P = 0.6). The lateral crus of the alar cartilage was consistently identified by all observers, whereas part of the medial crus was consistently missed. This study suggests that MRI is a feasible imaging modality for the development of 3D alar constructs for patient-specific reconstruction.


Assuntos
Imageamento por Ressonância Magnética/métodos , Cartilagens Nasais/diagnóstico por imagem , Modelagem Computacional Específica para o Paciente , Procedimentos de Cirurgia Plástica/métodos , Impressão Tridimensional , Idoso , Feminino , Humanos , Cartilagens Nasais/cirurgia
5.
Radiology ; 272(1): 113-22, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24617731

RESUMO

PURPOSE: To investigate the effects of cell therapy on myocardial perfusion recovery after treatment of acute myocardial infarction (MI) with primary percutaneous coronary intervention (PCI). MATERIALS AND METHODS: In this HEBE trial substudy, which was approved by the institutional review board (trial registry number ISRCTN95796863), the authors assessed the effects of intracoronary infusion with bone marrow-derived mononuclear cells (BMMCs) or peripheral blood-derived mononuclear cells (PBMCs) on myocardial perfusion recovery by using cardiac magnetic resonance (MR) imaging after revascularization. In 152 patients with acute MI treated with PCI, cardiac MR imaging was performed after obtaining informed consent-before randomization to BMMC, PBMC, or standard therapy (control group)-and repeated at 4-month follow-up. Cardiac MR imaging consisted of cine, rest first-pass perfusion, and late gadolinium enhancement imaging. Perfusion was evaluated semiquantitatively with signal intensity-time curves by calculating the relative upslope (percentage signal intensity change). The relative upslope was calculated for the MI core, adjacent border zone, and remote myocardium. Perfusion differences among treatment groups or between baseline and follow-up were assessed with the Wilcoxon signed rank or Mann-Whitney U test. RESULTS: At baseline, myocardial perfusion differed between the MI core (median, 6.0%; interquartile range [IQR], 4.1%-8.0%), border zone (median, 8.4%; IQR, 6.4%-10.2%), and remote myocardium (median, 12.2%; IQR, 10.5%-15.9%) (P < .001 for all), with equal distribution among treatment groups. These interregional differences persisted at follow-up (P < .001 for all). No difference in perfusion recovery was found between the three treatment groups for any region. CONCLUSION: After revascularization of ST-elevation MI, cell therapy does not augment the recovery of resting perfusion in either the MI core or border zone.


Assuntos
Transplante de Medula Óssea , Terapia Baseada em Transplante de Células e Tecidos/métodos , Leucócitos Mononucleares/transplante , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/patologia , Infarto do Miocárdio/terapia , Traumatismo por Reperfusão Miocárdica/patologia , Traumatismo por Reperfusão Miocárdica/terapia , Miocárdio/patologia , Adulto , Idoso , Técnicas de Imagem de Sincronização Cardíaca , Terapia Combinada , Meios de Contraste , Circulação Coronária , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Masculino , Meglumina , Pessoa de Meia-Idade , Neovascularização Fisiológica , Compostos Organometálicos , Intervenção Coronária Percutânea , Recuperação de Função Fisiológica , Resultado do Tratamento
7.
Eur J Radiol ; 81(9): 2042-8, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21724349

RESUMO

BACKGROUND: Quantification of abdominal blood flow is essential for a variety of gastrointestinal and hepatic topics such as liver transplantation or metabolic flux measurement, but those need to be performed during surgery. It is not clear whether Duplex Doppler Ultrasound during surgery or MRI before surgery is the tool to choose. OBJECTIVE: To examine whether preoperative evaluation of abdominal blood flow using MRI could prove to be a useful and reliable alternative for the perioperative sonographic approach. METHODS: In this study portal and renal venous flow and hepatic arterial flow were sequentially quantified by preoperative MRI, preoperative and perioperative Duplex Doppler Ultrasound (DDUS). 55 Patients scheduled for major abdominal surgery were studied and methods and settings were compared. Additionally, average patient population values were compared. RESULTS: Mean (±SD) plasmaflow measured by perioperative DDUS, preoperative DDUS and MRI, respectively was 433±200/423±162/507±96 ml/min (portal vein); 96±70/74±41/108±91 ml/min (hepatic artery); 248±139/201±118/219±69 ml/min (renal vein). No differences between the different settings of DDUS measurement were detected. Equality of mean was observed for all measurements. Bland Altman Plots showed widespread margins. Hepatic arterial flow measurements correlated with each other, but portal and renal venous flow correlations were absent. CONCLUSIONS: Surgery and method (DDUS vs. MRI) do not affect mean flow values. Individual comparison is restricted due to wide range in measurements. Since MRI proves to be more reliable with respect to inter-observer variability, we recommend using mean MRI results in experimental setups.


Assuntos
Circulação Hepática , Angiografia por Ressonância Magnética/métodos , Veia Porta/patologia , Veia Porta/fisiopatologia , Artéria Renal/patologia , Artéria Renal/fisiopatologia , Circulação Renal , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Assistência Perioperatória/métodos , Veia Porta/cirurgia , Cuidados Pré-Operatórios/métodos , Artéria Renal/cirurgia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
J Magn Reson Imaging ; 32(1): 88-93, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20578015

RESUMO

PURPOSE: To investigate the incremental diagnostic value of dual-bolus over single-contrast-bolus first pass magnetic resonance myocardial perfusion imaging (MR-MPI) for detection of significant coronary artery disease (CAD). MATERIALS AND METHODS: Patients (n = 49) with suspected CAD underwent first pass adenosine stress and rest MR-MPI and invasive coronary angiography (CA). Gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) was injected with a prebolus (1 mL) and a large bolus (0.1 mmol/kg). For the single-bolus technique, the arterial input function (AIF) was obtained from the large-contrast bolus. For the dual-bolus technique, the AIF was reconstructed from the prebolus. Absolute myocardial perfusion was calculated by Fermi-model constrained deconvolution. Receiver operating characteristic (ROC) analysis was used to investigate diagnostic accuracy of MR myocardial perfusion imaging for detection of significant CAD on CA at vessel-based analysis. RESULTS: The area under the curve (AUC) of the minimal stress perfusion value for the detection of significant CAD using the single-bolus and dual-bolus technique was 0.85 +/- 0.04 (95% confidence interval [CI], 0.77-0.93) and 0.77 +/- 0.05 (95% CI, 0.67-0.86), respectively. CONCLUSION: In this study the dual-bolus technique had no incremental diagnostic value over single-bolus technique for detection of significant CAD with the used contrast concentrations.


Assuntos
Meios de Contraste , Doença da Artéria Coronariana/diagnóstico , Gadolínio DTPA , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Área Sob a Curva , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes
9.
Coron Artery Dis ; 13(7): 365-72, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12488645

RESUMO

BACKGROUND: Coronary flow velocity reserve (CFVR), defined as the ratio of maximal hyperaemic to baseline flow velocity, has been validated as a marker of physiological significance of a coronary lesion. Clinically, this parameter is measured invasively during X-ray angiography using the Doppler guide wire. With magnetic resonance (MR) imaging it is possible to quantify CFVR non-invasively. DESIGN: The purpose of the study was to compare CFVR, acquired with MR imaging and the Doppler guide wire in patients with coronary artery disease. METHODS: Twenty-two patients suffering from one- or two-vessel coronary artery disease as derived from diagnostic X-ray coronary angiography were included. Coronary flow velocity reserve was measured at baseline and during maximal hyperaemia, obtained by intravenous administration of adenosine using MR phase contrast velocity quantification. Within 2 weeks CFVR was measured invasively with a Doppler guide wire. RESULTS: In 26 coronary arteries CFVR was acquired with both techniques. Mean CFVR in the stenosed and healthy reference arteries was 1.5 +/- 0.7 and 2.7 +/- 1.0 (P < 0.01) respectively for MR measurements and 1.9 +/- 0.7 and 3.1 +/- 0.6 (P < 0.01) respectively for Doppler measurements. Bland-Altman analysis revealed a non-significant mean difference between the two techniques of 0.4 +/- 1.2. CONCLUSION: In a selected group of stable patients with coronary artery disease MR flow velocity quantification provides non-invasive data equivalent to the invasive Doppler guide wire data. Variability in both the MR and Doppler ultrasound measurement resulted in a significant scatter of data without systematic difference.


Assuntos
Circulação Coronária/fisiologia , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Imagem Cinética por Ressonância Magnética , Ultrassonografia Doppler , Ultrassonografia de Intervenção , Velocidade do Fluxo Sanguíneo , Análise por Conglomerados , Feminino , Humanos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Software
10.
J Am Coll Cardiol ; 40(10): 1848-55, 2002 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-12446070

RESUMO

OBJECTIVES: The purpose of this study was to assess the value of cardiovascular magnetic resonance (CMR)-determined graft flow and flow reserve in differentiating significant from non-significant vein graft disease. BACKGROUND: In patients after coronary artery bypass grafting (CABG), non-invasive testing may be helpful in the detection of recurrent graft disease. METHODS: Randomly selected patients (n = 21) scheduled for X-ray angiography because of recurrent chest complaints after CABG were included for evaluation of vein grafts (n = 40) by CMR. Three-dimensional contrast-enhanced CMR angiography was performed and followed by flow measurements at rest and during hyperemia in patent grafts only. Flow reserve was calculated when resting flow exceeded 20 ml/min. Analysis was based on four categories defined by X-ray angiography: occluded grafts (n = 3), grafts with stenosis >50% (n = 19), grafts with stenosis <50% with diseased graft run-off (n = 8), and grafts with stenosis <50% and normal run-off (n = 10). RESULTS: The CMR angiography demonstrated occlusion of three grafts. In nine of the 37 patent grafts, basal blood flow was <20 ml/min, all demonstrating significant stenosis at X-ray angiography. In grafts with resting flow >20 ml/min (n = 28), flow reserve significantly differed between grafts without stenosis and grafts with significant stenosis or with diseased run-off (2.5 +/- 0.7 vs. 1.8 +/- 0.9, p = 0.04). An algorithm combining basal volume flow <20 ml/min and graft flow reserve <2 had a sensitivity and specificity of 78% and 80% respectively for detecting grafts with significant stenosis or diseased run-off. CONCLUSIONS: This feasibility study showed that quantification of flow and flow reserve by CMR may serve as a non-invasive adjunct to differentiate between vein grafts without stenosis and grafts with significant stenosis or diseased run-off.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Ponte de Artéria Coronária , Imageamento por Ressonância Magnética , Adulto , Idoso , Anastomose Cirúrgica , Artérias/fisiopatologia , Artérias/cirurgia , Angiografia Coronária , Estenose Coronária/diagnóstico , Estenose Coronária/fisiopatologia , Estenose Coronária/cirurgia , Vasos Coronários/fisiopatologia , Vasos Coronários/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veia Safena/diagnóstico por imagem , Veia Safena/cirurgia , Sensibilidade e Especificidade , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA