1.
Phys Imaging Radiat Oncol ; 13: 44-49, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32551371

RESUMO

BACKGROUND AND PURPOSE: Computed tomography (CT) scanning is the basis for radiation treatment planning, but the 50-cm standard scanning field of view (sFOV) may be too small for imaging larger patients. We evaluated the 65-cm high-definition (HD) FOV of a large-bore CT scanner for CT number accuracy, geometric distortion, image quality degradation, and dosimetric accuracy of photon treatment plans. MATERIALS AND METHODS: CT number accuracy was tested by placing two 16-cm acrylic phantoms on either side of a 40-cm phantom to simulate a large patient extending beyond the 50-cm-diameter standard scanning FOV. Dosimetric accuracy was tested using anthropomorphic pelvis and thorax phantoms, with additional acrylic body parts on either side of the phantoms. Two volumetric modulated arc therapy beams (a 15-MV and a 6-MV) were used to cover the planning target volumes. Two-dimensional dose distributions were evaluated with GAFChromic film and point dose accuracy was checked with multiple thermoluminescent dosimeter (TLD) capsules placed in the phantoms. Image quality was tested by placing an American College of Radiology accreditation phantom inside the 40-cm phantom. RESULTS: The HD FOV showed substantial changes in CT numbers, with differences of 314 HU-725 HU at different density levels. The volume of the body parts extending into the HD FOV was distorted. However, TLD-reported doses for all PTVs agreed within ± 3%. Dose agreement in organs at risk were within the passing criteria, and the gamma index pass rate was >97%. Image quality was degraded. CONCLUSIONS: The HD FOV option is adequate for RT simulation and met accreditation standards, although care should be taken during contouring because of reduced image quality.

2.
Br J Radiol ; 93(1107): 20190669, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31799859

RESUMO

OBJECTIVE: This study is part of ongoing efforts aiming to transit from measurement-based to combined patient-specific quality assurance (PSQA) in intensity-modulated proton therapy (IMPT). A Monte Carlo (MC) dose-calculation algorithm is used to improve the independent dose calculation and to reveal the beam modeling deficiency of the analytical pencil beam (PB) algorithm. METHODS: A set of representative clinical IMPT plans with suboptimal PSQA results were reviewed. Verification plans were recalculated using an MC algorithm developed in-house. Agreements of PB and MC calculations with measurements that quantified by the γ passing rate were compared. RESULTS: The percentage of dose planes that met the clinical criteria for PSQA (>90% γ passing rate using 3%/3 mm criteria) increased from 71.40% in the original PB calculation to 95.14% in the MC recalculation. For fields without beam modifiers, nearly 100% of the dose planes exceeded the 95% γ passing rate threshold using the MC algorithm. The model deficiencies of the PB algorithm were found in the proximal and distal regions of the SOBP, where MC recalculation improved the γ passing rate by 11.27% (p < 0.001) and 16.80% (p < 0.001), respectively. CONCLUSIONS: The MC algorithm substantially improved the γ passing rate for IMPT PSQA. Improved modeling of beam modifiers would enable the use of the MC algorithm for independent dose calculation, completely replacing additional depth measurements in IMPT PSQA program. For current users of the PB algorithm, further improving the long-tail modeling or using MC simulation to generate the dose correction factor is necessary. ADVANCES IN KNOWLEDGE: We justified a change in clinical practice to achieve efficient combined PSQA in IMPT by using the MC algorithm that was experimentally validated in almost all the clinical scenarios in our center. Deficiencies in beam modeling of the current PB algorithm were identified and solutions to improve its dose-calculation accuracy were provided.


Assuntos
Algoritmos , Método de Monte Carlo , Terapia com Prótons/normas , Garantia da Qualidade dos Cuidados de Saúde , Radioterapia de Intensidade Modulada/normas , Análise de Dados , Humanos , Terapia com Prótons/instrumentação , Terapia com Prótons/métodos , Controle de Qualidade , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Radioterapia de Intensidade Modulada/instrumentação , Radioterapia de Intensidade Modulada/métodos , Reprodutibilidade dos Testes , Síncrotrons
3.
Int J Part Ther ; 3(1): 37-50, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-31772974

RESUMO

PURPOSE: To determine whether a hybrid intensity-modulated proton therapy (IMPT) and passive scattered proton therapy (PSPT) technique, termed HimpsPT, could be adopted as an alternative delivery method for patients demanding scanning beam proton therapy. PATIENTS AND METHODS: We identified 3 representative clinical cases-an oropharyngeal cancer, skull base chordoma, and stage III non-small-cell lung cancer-that had been treated with IMPT at our center. We retrospectively redesigned these cases using HimpsPT. The PSPT plans for all three cases were designed with the same prescriptions as those used in the IMPT plans. In this way, the whole treatment was delivered using alternating or sequential PSPT and IMPT. RESULTS: All HimpsPT plans met the clinical dose criteria and were of similar quality as the IMPT plans. In the skull base case, the mixed plan was more effective at sparing the brain stem because the sharp penumbra of the aperture in the PSPT plans was not present in the IMPT plans. The HimpsPT plans were more robust than the clinical IMPT plans generated without robust optimization. CONCLUSION: The HimpsPT delivery technique can achieve a treatment-plan quality similar to that of IMPT, even in the most challenging clinical cases. In addition, at centers equipped with both scattering and scanning beam capabilities, the HimpsPT technique may allow more patients to benefit from scanning beam technology.