Eur J Radiol ; 175: 111448, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38574510

RESUMO

PURPOSE: Aim of the recent study is to point out a method to optimize quality of CT scans in oncological patients with port systems. This study investigates the potential of photon counting computed tomography (PCCT) for reduction of beam hardening artifacts caused by port-implants in chest imaging by means of spectral reconstructions. METHOD: In this retrospective single-center study, 8 ROIs for 19 spectral reconstructions (polyenergetic imaging, monoenergetic reconstructions from 40 to 190 keV as well as iodine maps and virtual non contrast (VNC)) of 49 patients with pectoral port systems undergoing PCCT of the chest for staging of oncologic disease were measured. Mean values and standard deviation (SD) Hounsfield unit measurements of port-chamber associated hypo- and hyperdense artifacts, bilateral muscles and vessels has been carried out. Also, a structured assessment of artifacts and imaging findings was performed by two radiologists. RESULTS: A significant association of keV with iodine contrast as well as artifact intensity was noted (all p < 0.001). In qualitative assessment, utilization of 120 keV monoenergetic reconstructions could reduce severe and pronounced artifacts completely, as compared to lower keV reconstructions (p < 0.001). Regarding imaging findings, no significant difference between monoenergetic reconstructions was noted (all p > 0.05). In cases with very high iodine concentrations in the subclavian vein, image distortions were noted at 40 keV images (p < 0.01). CONCLUSIONS: The present study demonstrates that PCCT derived spectral reconstructions can be used in oncological imaging of the thorax to reduce port-derived beam-hardening artefacts. When evaluating image data sets within a staging, it can be particularly helpful to consider the 120 keV VMIs, in which the artefacts are comparatively low.


Assuntos
Artefatos , Radiografia Torácica , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Tomografia Computadorizada por Raios X/métodos , Radiografia Torácica/métodos , Estudos Retrospectivos , Adulto , Idoso de 80 Anos ou mais , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Fótons , Reprodutibilidade dos Testes
2.
Eur Radiol Exp ; 7(1): 45, 2023 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-37505296

RESUMO

BACKGROUND: In the management of cancer patients, determination of TNM status is essential for treatment decision-making and therefore closely linked to clinical outcome and survival. Here, we developed a tool for automatic three-dimensional (3D) localization and segmentation of cervical lymph nodes (LNs) on contrast-enhanced computed tomography (CECT) examinations. METHODS: In this IRB-approved retrospective single-center study, 187 CECT examinations of the head and neck region from patients with various primary diseases were collected from our local database, and 3656 LNs (19.5 ± 14.9 LNs/CECT, mean ± standard deviation) with a short-axis diameter (SAD) ≥ 5 mm were segmented manually by expert physicians. With these data, we trained an independent fully convolutional neural network based on 3D foveal patches. Testing was performed on 30 independent CECTs with 925 segmented LNs with an SAD ≥ 5 mm. RESULTS: In total, 4,581 LNs were segmented in 217 CECTs. The model achieved an average localization rate (LR), i.e., percentage of localized LNs/CECT, of 78.0% in the validation dataset. In the test dataset, average LR was 81.1% with a mean Dice coefficient of 0.71. For enlarged LNs with a SAD ≥ 10 mm, LR was 96.2%. In the test dataset, the false-positive rate was 2.4 LNs/CECT. CONCLUSIONS: Our trained AI model demonstrated a good overall performance in the consistent automatic localization and 3D segmentation of physiological and metastatic cervical LNs with a SAD ≥ 5 mm on CECTs. This could aid clinical localization and automatic 3D segmentation, which can benefit clinical care and radiomics research. RELEVANCE STATEMENT: Our AI model is a time-saving tool for 3D segmentation of cervical lymph nodes on contrast-enhanced CT scans and serves as a solid base for N staging in clinical practice and further radiomics research. KEY POINTS: • Determination of N status in TNM staging is essential for therapy planning in oncology. • Segmenting cervical lymph nodes manually is highly time-consuming in clinical practice. • Our model provides a robust, automated 3D segmentation of cervical lymph nodes. • It achieves a high accuracy for localization especially of enlarged lymph nodes. • These segmentations should assist clinical care and radiomics research.


Assuntos
Linfonodos , Redes Neurais de Computação , Humanos , Estudos Retrospectivos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Tomografia Computadorizada por Raios X/métodos , Estadiamento de Neoplasias
3.
Radiology ; 305(1): 19-27, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35727149

RESUMO

A 61-year-old man with an esophageal cancer diagnosis underwent staging dual-energy CT of the chest and abdomen in the portal venous phase after contrast media administration. Aside from the primary tumor and suspicious local lymph nodes, CT revealed hypoattenuating ambiguous liver lesions, an incidental right adrenal nodule, and a right renal lesion with soft-tissue attenuation. In addition, advanced atherosclerosis of the abdominal aorta and its major branches was noted. This article provides a case-based review of dual-energy CT technologies and their applications in the abdomen. The clinical utility of virtual monoenergetic images, virtual unenhanced images, and iodine maps is discussed.


Assuntos
Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Radiologia , Abdome , Meios de Contraste , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
4.
Int J Oral Maxillofac Implants ; 36(6): 1211-1218, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34919623

RESUMO

PURPOSE: Cone beam computed tomography (CBCT) is considered both reliable and safe and provides reproducible results in guided dental implant planning procedures. However, it has weaknesses in soft tissue contrast and is associated with radiation exposure. Recent studies showed promising results with magnetic resonance imaging (MRI) as a possible noninvasive, radiation-free, alternative imaging modality for dental indications. The purpose of this study was to evaluate the quality of 1.5 T MRI with a dedicated dental signal-amplification coil in comparison to CBCT for dental implant planning procedures. MATERIALS AND METHODS: Sixteen subjects undergoing preoperative MRI (3D HR T1w TSE and 3D HR T1w FFE) and CBCT were included in this prospective study. All imaging data were used for dental implant planning procedures using commercially available software. Two experts scored the planning as "ideal," "improvable," or "unacceptable." Furthermore, quantitative distances according to EuCC recommendations were collected. Finally, discrepancies between CBCT and 3D HR T1w TSE were analyzed. Statistical analysis was performed using the Mann-Whitney U test and analysis of variance (ANOVA). RESULTS: The dental implant planning procedure was technically feasibly using all imaging data. CBCT allowed for "ideal" placement in all cases. Ratings for 3D HR T1w TSE and 3D HR T1w FFE were 81.9%, 18.1%, and 0% and 54.2%, 30.0%, and 15.3% for ideal, improvable, and unacceptable, respectively, identifying 3D HR T1w TSE as superior compared with 3D HR T1w FFE. Head-to-head comparison between CBCT and 3D HR T1w TSE revealed no significant differences regarding the apical position of the implant of 1.2 ± 0.7 mm and 1.3 ± 0.5 mm coronally, respectively (P = .287). The deviation of the planed angle was 3.0 ± 1.2 degrees. In these merged data sets, the distance to the mandibular canal was significantly higher with 1.3 ± 0.8 mm, indicating better utilization of the existing bone. CONCLUSION: Within the limits of this pilot study, it can be reported that the dental image planning procedure is feasible using 1.5 T MRI with a dedicated dental coil and specific MRI sequences.


Assuntos
Canal Mandibular , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Imageamento por Ressonância Magnética , Projetos Piloto , Estudos Prospectivos
5.
PLoS One ; 16(6): e0252678, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34129650

RESUMO

OBJECTIVES: To investigate whether virtual monoenergetic images (VMI) and iodine maps derived from spectral detector computed tomography (SDCT) improve early assessment of technique efficacy in patients who underwent microwave ablation (MWA) for hepatocellular carcinoma (HCC) in liver cirrhosis. METHODS: This retrospective study comprised 39 patients with 49 HCC lesions treated with MWA. Biphasic SDCT was performed 7.7±4.0 days after ablation. Conventional images (CI), VMI and IM were reconstructed. Signal- and contrast-to-noise ratio (SNR, CNR) in the ablation zone (AZ), hyperemic rim (HR) and liver parenchyma were calculated using regions-of-interest analysis and compared between CI and VMI between 40-100 keV. Iodine concentration and perfusion ratio of HR and residual tumor (RT) were measured. Two readers evaluated subjective contrast of AZ and HR, technique efficacy (complete vs. incomplete ablation) and diagnostic confidence at determining technique efficacy. RESULTS: Attenuation of liver parenchyma, HR and RT, SNR of liver parenchyma and HR, CNR of AZ and HR were significantly higher in low-keV VMI compared to CI (all p<0.05). Iodine concentration and perfusion ratio differed significantly between HR and RT (all p<0.05; e.g. iodine concentration, 1.6±0.5 vs. 2.7±1.3 mg/ml). VMI50keV improved subjective AZ-to-liver contrast, HR-to-liver contrast, visualization of AZ margin and vessels adjacent to AZ compared to CI (all p<0.05). Diagnostic accuracy for detection of incomplete ablation was slightly higher in VMI50keV compared to CI (0.92 vs. 0.89), while diagnostic confidence was significantly higher in VMI50keV (p<0.05). CONCLUSIONS: Spectral detector computed tomography derived low-keV virtual monoenergetic images and iodine maps provide superior early assessment of technique efficacy of MWA in HCC compared to CI.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Micro-Ondas/uso terapêutico , Ablação por Radiofrequência/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Carcinoma Hepatocelular/complicações , Carcinoma Hepatocelular/cirurgia , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Fígado/cirurgia , Cirrose Hepática/complicações , Neoplasias Hepáticas/complicações , Neoplasias Hepáticas/cirurgia , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Razão Sinal-Ruído
6.
Diagnostics (Basel) ; 11(2)2021 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-33670457

RESUMO

Neuroendocrine tumors (NETs) are relatively rare neoplasms arising from the hormone-producing neuroendocrine system that can occur in various organs such as pancreas, small bowel, stomach and lung. As the majority of these tumors express somatostatin receptors (SSR) on their cell membrane, utilization of SSR analogs in nuclear medicine is a promising, but relatively costly approach for detection and localization. The aim of this study was to analyze the cost-effectiveness of 68Ga-DOTA-TATE PET/CT (Gallium-68 DOTA-TATE Positron emission tomography/computed tomography) compared to 111In-pentetreotide SPECT/CT (Indium-111 pentetreotide Single Photon emission computed tomography/computed tomography) and to CT (computed tomography) alone in detection of NETs. A decision model on the basis of Markov simulations evaluated lifetime costs and quality-adjusted life years (QALYs) related to either a CT, SPECT/CT or PET/CT. Model input parameters were obtained from publicized research projects. The analysis is grounded on the US healthcare system. Deterministic sensitivity analysis of diagnostic parameters and probabilistic sensitivity analysis predicated on a Monte Carlo simulation with 30,000 reiterations was executed. The willingness-to-pay (WTP) was determined to be $ 100,000/QALY. In the base-case investigation, PET/CT ended up with total costs of $88,003.07 with an efficacy of 4.179, whereas CT ended up with total costs of $88,894.71 with an efficacy of 4.165. SPECT/CT ended up with total costs of $89,973.34 with an efficacy of 4.158. Therefore, the strategies CT and SPECT/CT were dominated by PET/CT in the base-case scenario. In the sensitivity analyses, PET/CT remained a cost-effective strategy. This result was due to reduced therapy costs of timely detection. The additional costs of 68Ga-DOTA-TATE PET/CT when compared to CT alone are justified in the light of potential savings in therapy costs and better outcomes.

7.
Acta Radiol ; 62(2): 172-181, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32306744

RESUMO

BACKGROUND: Evaluation of small cystic lesions of the pancreas remains a challenging task, as due to their size appearance can be rather hypodense than clearly fluid-filled. PURPOSE: To evaluate whether additional information provided by novel dual-layer spectral-detector computed tomography (SDCT) imaging can improve assessment of these lesions. MATERIAL AND METHODS: For this retrospective study, we reviewed reports of 1192 contrast-enhanced portal-venous phase SDCT scans of the abdomen conducted between May 2017 and January 2019. On basis of the radiological report 25 small (≤1.5 cm) cystic pancreatic lesions in 22 patients were identified, in which additional short-term follow-up imaging was recommended to confirm/clarify cystic nature. Conventional images (CI) and spectral images (SI) including virtual-monoenergetic images at 40 keV (VMI), iodine-density and iodine-overlay images were reconstructed. Two readers indicated lesion conspicuity and confidence for presence of cystic nature on three-point scales. First, solely CI were evaluated, while in a second reading after a four-week interval, the combination of CI and corresponding SI were reviewed. Quantitatively, ROI-based mean attenuation was measured in CI and VMI. RESULTS: In the subjective reading, SI significantly improved lesion conspicuity (CI 2 [1-2], SI 3 [2-3], P < 0.001) and confidence regarding presence of cystic nature (CI 2 [1-2], SI 3 [3-3], P < 0.001). Inter-observer agreement depicted by intraclass correlation coefficient improved considerably from 0.51 with only CI to 0.85 when the combination with SI was used. Further, VMI displayed significantly higher signal-to-noise (CI 1.2 ± 0.8, VMI 3.2 ± 1.8, P < 0.001) and contrast-to-noise ratios (CI 2.6 ± 0.8, VMI 4.7 ± 1.9). CONCLUSION: Compared to CI alone, combination with SI significantly improves visualization and confidence in evaluation of small equivocal cystic pancreatic lesions.


Assuntos
Cisto Pancreático/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pâncreas/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS