Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
2.
J Shoulder Elbow Surg ; 19(7): 1076-84, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20363159

RESUMO

BACKGROUND: The purpose of this study was to describe the pathoanatomy of patients diagnosed with rheumatoid arthritis and rotator cuff deficiency and report their outcomes following reverse shoulder arthroplasty. METHODS: Twenty-one shoulders were evaluated prospectively. Nine had no prior surgery, 9 had a failed rotator cuff repair, and 3 had a failed arthroplasty. Patients were followed for a minimum of 2 years (average, 36 months). All patients had preoperative radiographs and 19 shoulders had an MRI or CT available for evaluation of muscular and bony deficiency. Radiographs at most recent follow-up were evaluated for loosening and scapular notching. RESULTS: All outcome measures improved significantly: ASES scores improved from 28 preoperatively to 82 postoperatively (P < .0001); SST scores improved from 1 to 7 (P < .0001); VAS pain scores improved from 7 to 1 (P < .0001); VAS function scores improved from 3 to 6 (P=.0058); elevation improved from 52° to 126° (P < .0001); abduction improved from 55° to 116° (P=.0002); external rotation improved from 19° to 33° (P=.02); and internal rotation improved from S1 to L4 (P=.02). Twelve patients rated their outcome as excellent, 6 as good, 2 as satisfactory, and 1 as unsatisfactory. Severe glenoid erosion was seen in 10 of the shoulders and 5 of the defects required structural grafting. Three patients (14%) sustained a complication that required reoperation: 2 for infection and 1 for periprosthetic fracture. CONCLUSIONS: In patients with rheumatoid arthritis and rotator cuff deficiency, reverse shoulder arthroplasty can provide improvement in function and decreased pain.


Assuntos
Artrite Reumatoide/cirurgia , Artroplastia de Substituição/métodos , Articulação do Ombro/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Medição da Dor , Recuperação de Função Fisiológica , Manguito Rotador/patologia , Lesões do Manguito Rotador , Tomografia Computadorizada por Raios X , Resultado do Tratamento
3.
J Shoulder Elbow Surg ; 19(4): 570-9, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19800258

RESUMO

HYPOTHESIS: A retrospective analysis was conducted of 2 consecutive groups of patients undergoing total shoulder arthroplasty (TSA) for primary osteoarthritis. One group was treated with formal physical therapy (PT), and one group was treated with home-based, physician-guided PT. We hypothesized that patients with a formal postoperative PT protocol would have significantly better postoperative clinical outcomes than patients with no formal PT. METHODS: Group A (43 patients) had a standard PT program. Group B (38 patients) had a home-based, physician-guided PT program. Clinical outcomes (preoperatively, 3, 6, and 12 months and most recent follow-up) were analyzed. A minimum sample size of 31 patients gives power to detect a 10-point American Shoulder and Elbow Surgeons (ASES) score (alpha=0.05, beta=0.80). RESULTS: ASES and Simple Shoulder Test (SST) scores significantly improved in both groups at all follow-up periods. Forward flexion and abduction were significantly improved in group B at all time points, whereas an initial improvement in forward flexion and abduction in group A was lost at final follow-up. There were no significant differences in final ASES or SST scores between groups at final follow-up. However, forward flexion, abduction, and the Short Form-36 physical component summary in group B were significantly better than group A at final follow-up. No significant improvements in internal rotation or SF-36 mental component summary were seen within or between the groups at final follow-up. Overall, there was no difference in patient satisfaction, with 88% satisfaction in group A and 95% satisfaction in group B (chi(2)=0.471, P=.4924). CONCLUSIONS: A home-based, physician-guided therapy program may provide adequate rehabilitation after TSA, allowing for a reduction in cost for the overall procedure.


Assuntos
Artroplastia de Substituição/métodos , Osteoartrite/reabilitação , Modalidades de Fisioterapia , Avaliação de Programas e Projetos de Saúde , Articulação do Ombro , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/fisiopatologia , Osteoartrite/cirurgia , Satisfação do Paciente , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Estudos Retrospectivos , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
4.
J Shoulder Elbow Surg ; 18(5): 717-23, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19278872

RESUMO

BACKGROUND: The aim of this study is to document a single surgeon's experience performing revision reverse shoulder arthroplasty after baseplate failure. METHODS: Revision reverse shoulder arthroplasty (RSA) for mechanical failure of the glenoid baseplate after RSA was performed in 14 patients. Clinical and radiographic data were collected preoperatively, prior to baseplate failure, after baseplate failure, and at latest follow-up after revision (average, 33 months). RESULTS: When comparing the pre-operative values to post-revision, ASES, forward elevation, and abduction were significantly improved. There was no significant difference in any of the outcome measures when comparing the prefailure data to the post-revision data. The post-revision prosthesis-scapular neck angle (PSNA) showed a significant increase in inferior tilt of the baseplate when compared to pre-failure PSNA (P < .001). Two patients (14%) required a second revision RSA for glenoid baseplate failure (1) and dislocation (1); 1 additional patient developed a postoperative hematoma which resolved without surgery. CONCLUSION: Revision RSA for the treatment of glenoid baseplate mechanical failure can restore pain relief and function to the levels gained after the index RSA.


Assuntos
Artroplastia de Substituição/efeitos adversos , Artroplastia de Substituição/métodos , Falha de Prótese , Amplitude de Movimento Articular/fisiologia , Articulação do Ombro/cirurgia , Idoso , Idoso de 80 Anos ou mais , Placas Ósseas , Estudos de Coortes , Feminino , Seguimentos , Humanos , Prótese Articular , Masculino , Pessoa de Meia-Idade , Medição da Dor , Satisfação do Paciente , Desenho de Prótese , Qualidade de Vida , Radiografia , Recuperação de Função Fisiológica , Reoperação/métodos , Estudos Retrospectivos , Medição de Risco , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA