Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
EJNMMI Phys ; 11(1): 36, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38581561

RESUMO

PURPOSE: A 2D image navigator (iNAV) based 3D whole-heart sequence has been used to perform MRI and PET non-rigid respiratory motion correction for hybrid PET/MRI. However, only the PET data acquired during the acquisition of the 3D whole-heart MRI is corrected for respiratory motion. This study introduces and evaluates an MRI-based respiratory motion correction method of the complete PET data. METHODS: Twelve oncology patients scheduled for an additional cardiac 18F-Fluorodeoxyglucose (18F-FDG) PET/MRI and 15 patients with coronary artery disease (CAD) scheduled for cardiac 18F-Choline (18F-FCH) PET/MRI were included. A 2D iNAV recorded the respiratory motion of the myocardium during the 3D whole-heart coronary MR angiography (CMRA) acquisition (~ 10 min). A respiratory belt was used to record the respiratory motion throughout the entire PET/MRI examination (~ 30-90 min). The simultaneously acquired iNAV and respiratory belt signal were used to divide the acquired PET data into 4 bins. The binning was then extended for the complete respiratory belt signal. Data acquired at each bin was reconstructed and combined using iNAV-based motion fields to create a respiratory motion-corrected PET image. Motion-corrected (MC) and non-motion-corrected (NMC) datasets were compared. Gating was also performed to correct cardiac motion. The SUVmax and TBRmax values were calculated for the myocardial wall or a vulnerable coronary plaque for the 18F-FDG and 18F-FCH datasets, respectively. RESULTS: A pair-wise comparison showed that the SUVmax and TBRmax values of the motion corrected (MC) datasets were significantly higher than those for the non-motion-corrected (NMC) datasets (8.2 ± 1.0 vs 7.5 ± 1.0, p < 0.01 and 1.9 ± 0.2 vs 1.2 ± 0.2, p < 0.01, respectively). In addition, the SUVmax and TBRmax of the motion corrected and gated (MC_G) reconstructions were also higher than that of the non-motion-corrected but gated (NMC_G) datasets, although for the TBRmax this difference was not statistically significant (9.6 ± 1.3 vs 9.1 ± 1.2, p = 0.02 and 2.6 ± 0.3 vs 2.4 ± 0.3, p = 0.16, respectively). The respiratory motion-correction did not lead to a change in the signal to noise ratio. CONCLUSION: The proposed respiratory motion correction method for hybrid PET/MRI improved the image quality of cardiovascular PET scans by increased SUVmax and TBRmax values while maintaining the signal-to-noise ratio. Trial registration METC162043 registered 01/03/2017.

2.
Cerebrovasc Dis Extra ; 13(1): 18-32, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36646051

RESUMO

INTRODUCTION: Microvascular rarefaction, the functional reduction in perfused microvessels and structural reduction of microvascular density, seems to be an important mechanism in the pathophysiology of small blood vessel-related disorders including vascular cognitive impairment (VCI) due to cerebral small vessel disease and heart failure with preserved ejection fraction (HFpEF). Both diseases share common risk factors including hypertension, diabetes mellitus, obesity, and ageing; in turn, these comorbidities are associated with microvascular rarefaction. Our consortium aims to investigate novel non-invasive tools to quantify microvascular health and rarefaction in both organs, as well as surrogate biomarkers for cerebral and/or cardiac rarefaction (via sublingual capillary health, vascular density of the retina, and RNA content of circulating extracellular vesicles), and to determine whether microvascular density relates to disease severity. METHODS: The clinical research program of CRUCIAL consists of four observational cohort studies. We aim to recruit 75 VCI patients, 60 HFpEF patients, 60 patients with severe aortic stenosis (AS) undergoing surgical aortic valve replacement as a pressure overload HFpEF model, and 200 elderly participants with mixed comorbidities to serve as controls. Data collected will include medical history, physical examination, cognitive testing, advanced brain and cardiac MRI, ECG, echocardiography, sublingual capillary health, optical coherence tomography angiography (OCTa), extracellular vesicles RNA analysis, and myocardial remodelling-related serum biomarkers. The AS cohort undergoing surgery will also have myocardial biopsy for histological microvascular assessment. DISCUSSION: CRUCIAL will examine the pathophysiological role of microvascular rarefaction in VCI and HFpEF using advanced brain and cardiac MRI techniques. Furthermore, we will investigate surrogate biomarkers for non-invasive, faster, easier, and cheaper assessment of microvascular density since these are more likely to be disseminated into widespread clinical practice. If microvascular rarefaction is an early marker of developing small vessel diseases, then measuring rarefaction may allow preclinical diagnosis, with implications for screening, risk stratification, and prevention. Further knowledge of the relevance of microvascular rarefaction and its underlying mechanisms may provide new avenues for research and therapeutic targets.


Assuntos
Disfunção Cognitiva , Insuficiência Cardíaca , Rarefação Microvascular , Humanos , Idoso , Insuficiência Cardíaca/diagnóstico por imagem , Volume Sistólico , Disfunção Cognitiva/diagnóstico , Biomarcadores , RNA , Estudos Observacionais como Assunto
3.
Eur Heart J Case Rep ; 6(1): ytab530, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35106444

RESUMO

BACKGROUND: Surgical epicardial atrial fibrillation (AF) ablation can be performed as a stand-alone (thoracoscopic) procedure or concomitant to other cardiac surgery. In hybrid AF ablation thoracoscopic surgical epicardial ablation is combined with a percutaneous endocardial ablation. The Medtronic Gemini-S clamp is a surgical tool that uses irrigated bipolar biparietal radiofrequency (RF) energy applied with two clamp lesions that overlap to create one epicardial box lesion including the posterior left atrial wall and the pulmonary veins. CASE SUMMARY: We describe three patients with therapy-refractory persistent AF and different stages of atrial remodelling in whom the Medtronic Cardioblate Gemini-S Irrigated RF Surgical Ablation System was used for hybrid AF ablation. Acute endocardial validation at the end of the hybrid ablation revealed a complete box lesion in all three cases. At 2-year follow-up, two out of three patients had recurrence of atrial arrhythmias. Invasive electro-anatomical mapping confirmed the persistence of the box lesion, and the mechanism of arrhythmia recurrence in both patients was unrelated to posterior left atrium or the pulmonary veins. The third patient has been without arrhythmia symptoms since the ablation procedure. A three-dimensional late gadolinium enhancement magnetic resonance imaging illustrates the ablation scar non-invasively in two cases. DISCUSSION: Thoracoscopic biparietal RF AF ablation with the Medtronic Cardioblate Gemini-S Irrigated RF Surgical Ablation System results in permanent transmural scar formation, irrespective of the stage of atrial remodelling, as shown in this small population by means of multimodality scar evaluation.

4.
Acta Derm Venereol ; 101(6): adv00474, 2021 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-33903919

RESUMO

Optical coherence tomography is a non-invasive imaging technique that enables high-resolution in vivo imaging of skin. Although optical coherence tomography is promising for diagnosing basal cell carcinoma, its limited penetration depth may impede basal cell carcinoma subtyping. This study evaluated whether topical application of glycerol can increase penetration depth and improve the image quality and visibility of characteristic features of basal cell carcinoma. A total of 61 patients with a total of 72 basal cell carcinomas were included. Optical coherence tomography scans were obtained before and after application of an 85% glyce-rol solution. The mean penetration depth of each optical coherence tomography scan was acquired by automatically tracing both skin surface and the point of signal loss using a custom-made MATLAB program. Mean ± standard deviation penetration depth increased from 883 ± 108 to 904 ± 88 µm before and after glycerol application, respectively (p = 0.005). Topical application of glycerol leads to a significant 2.4% increase in penetration depth. However, no significant differences in image quality and visibility of basal cell carcinoma features were found.


Assuntos
Carcinoma Basocelular , Neoplasias Cutâneas , Carcinoma Basocelular/diagnóstico por imagem , Carcinoma Basocelular/tratamento farmacológico , Glicerol , Humanos , Pele/diagnóstico por imagem , Neoplasias Cutâneas/diagnóstico por imagem , Neoplasias Cutâneas/tratamento farmacológico , Tomografia de Coerência Óptica
5.
Invest Radiol ; 56(5): 335-340, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33273374

RESUMO

MATERIALS AND METHODS: Fifty consecutive patients with previous cardiac arrhythmias, scheduled for high-resolution 3D LGE MRI, were prospectively enrolled between October 2017 and February 2020. Free-breathing 3D dark-blood LGE MRI with high isotropic resolution (1.6 × 1.6 × 1.6 mm) was performed using a conventional fixed TI (n = 25) or a dynamic TI (n = 25). The average increase in blood nulling TI per minute was obtained from Look-Locker scans before and after the 3D acquisition in the first fixed TI group. This average increment in TI was used as input to calculate the dynamic increment of the initial blood nulling TI value as set in the second dynamic TI group. Regions of interest were drawn in the left ventricular blood pool to assess mean signal intensity as a measure for blood pool suppression. Overall image quality, observer confidence, and scar demarcation were scored on a 3-point scale. RESULTS: Three-dimensional dark-blood LGE data sets were successfully acquired in 46/50 patients (92%). The calculated average TI increase of 2.3 ± 0.5 ms/min obtained in the first fixed TI group was incorporated in the second dynamic TI group and led to a significant decrease of 72% in the mean blood pool signal intensity compared with the fixed TI group (P < 0.001). Overall image quality (P = 0.02), observer confidence (P = 0.02), and scar demarcation (P = 0.01) significantly improved using a dynamic TI. CONCLUSIONS: A steadily increasing dynamic TI improves blood pool suppression for optimized dark-blood contrast and increases observer confidence in free-breathing 3D dark-blood LGE MRI with high isotropic resolution.


Assuntos
Meios de Contraste , Gadolínio , Cicatriz/patologia , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Respiração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA