Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Hip Int ; 33(1): 73-80, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33845623

RESUMO

BACKGROUND AND PURPOSE: Adding hydroxyapatite to a stem to enhance ingrowth is a matter of debate, even less is known about the long-term effect on stability by adding hydroxyapatite (HA). Continuous migration in the first 2-5 years is an indicator of failed osteointegration or pending failure, enhancing the risk of loosening within 10 years after initial surgery. We performed a double-blinded randomised RSA trial with 5-year follow-up, to compare and analyse migration characteristics of the hydroxyapatite uncoated (HA-) and hydroxyapatite coated (HA+) Zweymuller-type hip stem. PATIENTS AND METHODS: In this single-centre prospective randomised controlled trial 51 patients were randomised to receive either a HA- or a HA+ Zweymuller-type hip stem during total hip replacement. After 5 years, 35 patients were still eligible for follow-up evaluation. The migration pattern was measured by use of radio stereometric analysis (RSA) images up to 2 years to evaluate short-term migration, additionally RSA images were obtained 5 years postoperatively to assess late-term and continuous migration. Furthermore, the improvement of clinical outcome was analysed by HSS and HOOS ADL and pain subscales preoperative and after 5 years. RESULTS: After initial settling of the implant, no significant migration occurred up to 5 years post-surgery for HA+ as well as HA- prostheses. Continuous migration within the 2-5 years' time interval was not observed for both HA+ nor the HA- group in all directions (p < 0.05). No significant difference between both groups was observed (p < 0.10). In both groups the HHS and HOOS improved significantly at 5 years compared to baseline for both groups. Improvement was not altered by the hydroxyapatite coating. No significant difference between both groups was observed (p > 0.58). CONCLUSIONS: Addition of a hydroxyapatite coating did not influence the migration 5 years postoperatively for the Zweymuller-type hip stem.Clinical Trial Protocol number: NL 23524.048.08.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Durapatita , Seguimentos , Estudos Prospectivos , Materiais Revestidos Biocompatíveis , Desenho de Prótese , Falha de Prótese
2.
Foot Ankle Int ; 43(10): 1285-1294, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35786056

RESUMO

BACKGROUND: The ceramic coated implant (CCI) Evolution was a third-generation implant design used in approximately 2000 total ankle replacements (TARs) between 2003 and 2016. Because this implant was abandoned, long-term follow-up studies are lacking. METHODS: All patients undergoing TAR using a CCI prosthesis between 2004 and 2012 were included for analysis. Preoperatively the tibiotalar alignment was measured, and postoperatively the patients were followed up clinically, with radiographs and by questionnaire. The primary outcome was implant survival at 10 years of follow-up. Implant survival was also compared for (1) inflammatory joint disease vs noninflammatory joint disease and (2) preoperative tibiotalar neutral vs varus or valgus alignment. The secondary outcomes were complications, reoperations, and function (assessed by patient-reported outcome measures). RESULTS: Two hundred fifty-four TARs were performed in 237 patients. Two hundred twelve additional procedures were performed to achieve stable ankles. At 10-year follow-up, the survival was 67.5%, with an average time to revision of 4.5 years. The 10-year survival of the inflammatory joint disease group was 76.8% and of the noninflammatory joint group 63.1% (P = .44). In 248 TARs, the preoperative tibiotalar alignment was measured; (62% neutral, 25% varus, and 13% valgus), these showed 10-year survival rates of 74.7%, 48.2%, and 68.9% respectively (P = .07). The complication rate was 54%; 37% of patients underwent reoperation. At a mean of 8.5 years, postoperative satisfaction scored an average of 7.0 (SD 2.26) on a 0- to 10-point numeric rating scale. The mean Foot and Ankle Ability Measure sports subscore was 24.7, the mean Foot and Ankle Outcome Score (FAOS) sports subscore was 42.8, and the mean 36-Item Short Form Health Survey score was 40.0. Regarding daily activities, the mean FAOS was 81.0. CONCLUSION: This is currently the sole study reporting the long-term results of the CCI prosthesis. The survival and functional outcomes were inferior to other third-generation mobile-bearing ankle implants.


Assuntos
Artroplastia de Substituição do Tornozelo , Artropatias , Prótese Articular , Articulação do Tornozelo/cirurgia , Cerâmica , Seguimentos , Humanos , Artropatias/cirurgia , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
3.
Foot Ankle Surg ; 28(5): 543-549, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34116950

RESUMO

BACKGROUND: The National Institute for Health and Care Excellence criterion for hip replacements is a (projected) revision rate of less than 5% after 10 years. No such criterion is available for ankle prostheses. The objective of the current study is to compare survival rates of contemporary primary ankle prostheses to the hip-benchmark. METHODS: The PRISMA methodology was used. Eligible for inclusion were clinical studies reporting revision rates of currently available primary total ankle prostheses. Data was extracted using preconstructed forms. The total and prosthesis-specific annual revision rate was calculated. RESULTS: Fifty-seven articles of eight different ankle prostheses were included (n = 5371), totaling 513 revisions at an average 4.6 years of follow-up. An annual revision rate of 2.2 was found (i.e. an expected revision rate of 22% at 10 years). CONCLUSIONS: The expected 10-year revision rate of contemporary ankle prostheses is lower than the current benchmark for hip prostheses.


Assuntos
Artroplastia de Substituição do Tornozelo , Artroplastia de Quadril , Prótese Articular , Tornozelo , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação
4.
Knee Surg Sports Traumatol Arthrosc ; 30(8): 2707-2713, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33934194

RESUMO

BACKGROUND: In primary Total Knee Arthroplasty (TKA), it is still not clear if cemented or uncemented fixation has the best long-term survival. The Low Contact Stress (LCS) mobile-bearing (MB) knee system was introduced in 1977. The aim of this study is to investigate the long-term survival of this design with a minimum of 15-year follow-up. METHODS: A retrospective analysis was performed, with the primary endpoint for survival defined as revision. Cox regression analysis was performed to assess the association between type of fixation and the risk of revision, while correcting for potential confounders (diagnosis, design, age and sex). RESULTS: 1271 cases were included with inflammatory joint disease (IJD) (657 cases) and non-IJD (614 cases). TKAs were performed cemented in 522 cases and uncemented in 749 cases. A bicruciate retaining design was used in 180 cases, a rotating platform design in 174 cases and an anterior posterior glide posterior cruciate-retaining (PCR) design in 916 cases. Cumulative incidence of component revision at 15 years was 2.7% (95% CI 1.6; 4.5) for cemented and 10% (95% CI 8.1; 12.4) for uncemented TKA, respectively. The 20-year cumulative incidence was 2.9% (95% CI 1.7; 4.7) for cemented and 10.9% (95% CI 8.8; 13.4) for uncemented TKA, respectively. Age, non-IJD and PCR design were associated with a significantly higher risk of revision, regardless of the type of fixation. CONCLUSION: Long-term survival for patients undergoing cemented or uncemented TKA using the LCS MB system revealed lower revision rates for cemented fixation. Revision risk was higher in younger, non-IJD patients who had the PCR design, regardless of the type of fixation. For the LCS MB TKA design, it is recommended to use cemented fixation.


Assuntos
Cimentos Ósseos , Falha de Prótese , Humanos , Desenho de Prótese , Sistema de Registros , Reoperação/efeitos adversos , Estudos Retrospectivos , Análise de Sobrevida , Resultado do Tratamento
5.
Acta Orthop Belg ; 87(2): 327-331, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34529388

RESUMO

Trial fitting of the cup during total hip arthroplasty (THA) is done by trial cups, which do not resemble the real press-fit obtained by the definitive implant. Our goal is to judge feasibility of the X-pander® in clinical practice ; a device developed to mimic the real press-fit obtained by the definitive cup, to ensure satisfactory press-fit. In this feasibility study 45 experienced orthopaedic surgeons from 7 European countries filled in a structured survey after 78 primary THA and 31 revision surgeries, using the X-pander instead of traditional trial cups. Primary outcomes were decision change concerning cup size or further reaming and increased confidence regarding cup insertion and size. Additionally, potential association between the primary outcomes and procedure (primary or revi- sion), bone quality and experience of the surgeon were evaluated. In 33.3% of the primary and 32.2% of the revision cases the X-pander measurement changed the deci- sion and further reaming or change of cup size was decided. In 61.5% and 58.1% of respectively the primary and revision THAs the X-pander was judged to give fairly to much more reliable information than traditional trial cups. The X-pander could lead to less additional screw fixation, as stated in 37.2% of the primary and 25.8% of the revision cases and to better cup insertion in respectively 50.0% and 51.6%. This study validates that the X-pander may be a suitable option for accurate sizing and assessment of the reamed acetabulum and could replace traditional trial cups in THA.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/cirurgia , Estudos de Viabilidade , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação
6.
Bone Joint J ; 103-B(1): 98-104, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33380179

RESUMO

AIMS: For many designs of total knee arthroplasty (TKA) it remains unclear whether cemented or uncemented fixation provides optimal long-term survival. The main limitation in most studies is a retrospective or non-comparative study design. The same is true for comparative trials looking only at the survival rate as extensive sample sizes are needed to detect true differences in fixation and durability. Studies using radiostereometric analysis (RSA) techniques have shown to be highly predictive in detecting late occurring aseptic loosening at an early stage. To investigate the difference in predicted long-term survival between cemented, uncemented, and hybrid fixation of TKA, we performed a randomized controlled trial using RSA. METHODS: A total of 105 patients were randomized into three groups (cemented, uncemented, and hybrid fixation of the ACS Mobile Bearing (ACS MB) knee system, implantcast). RSA examinations were performed on the first day after surgery and at scheduled follow-up visits at three months, six months, one year, and two years postoperatively. Patient-reported outcome measures (PROMs) were obtained preoperatively and after two years follow-up. Patients and follow-up investigators were blinded for the result of randomization. RESULTS: RSA secondary stabilization did not show a significant difference between the three types of fixation. A maximum total point motion of less than 0.2 mm in the second postoperative year was shown in each group, which suggests stabilization of the implant. At 24 months after surgery, PROMs significantly improved compared to baseline in all treatment groups. No significant difference was observed between the three groups. CONCLUSION: Secondary stabilization measurements in this study demonstrated no significant difference between the groups. In all groups migration stabilized after initial settling of the implant. For this implant the long-term outcome is not expected to be influenced by the type of fixation to the bone. Cite this article: Bone Joint J 2021;103-B(1):98-104.


Assuntos
Artroplastia do Joelho/métodos , Cimentação , Prótese do Joelho , Análise Radioestereométrica , Adulto , Idoso , Idoso de 80 Anos ou mais , Cimentos Ósseos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Desenho de Prótese , Falha de Prótese
7.
World J Orthop ; 11(10): 442-452, 2020 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-33134107

RESUMO

BACKGROUND: Polyethylene (PE) particles produced by wear of the acetabular insert are thought to cause osteolysis and thereby aseptic loosening of the implant in total hip arthroplasty (THA). As highly cross-linked polyethylene (HXLPE) is presumed to give lower wear rates, in vivo studies are needed to confirm this. AIM: To compare the wear of REXPOL, a HXPLE, with conventional PE within the first five years after implantation using Roentgen stereophotogrammetric analysis (RSA). METHODS: Patients were randomised to receive either a HXLPE (REXPOL) or a conventional PE insert during primary THA. RSA images were obtained directly postoperative and after 6 wk, 12 wk, 6 mo, 12 mo, 24 mo and five years. Functional outcomes were assessed using the Hip Injury and Osteoarthritis Outcome Score and Harris Hip Score at baseline and five years after surgery. RESULTS: The HXLPE (REXPOL) showed less wear in the latero-medial direction. Significant wear rates of conventional PE were seen in the latero-medial and center-proximal direction and in volume and corrected volume, whereas the REXPOL did not show these outcomes over time. Improvement from baseline in functional outcome did not significantly differ. CONCLUSION: Total 3D wear is less in THAs inserted with a REXPOL inlay than a conventional PE inlay after five years. This study confirms, for the first, that the REXPOL HXLPE inlay is preferred to standard PE.

8.
Foot Ankle Int ; 40(5): 553-561, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30700155

RESUMO

BACKGROUND: Total ankle replacement (TAR) is gaining popularity as a treatment option for ankle osteoarthritis. Long-term implant survival is a critical outcome to determine the success of the TAR implant. The Buechel-Pappas (BP) implant is a second-generation mobile bearing implant. The aim of this study was to analyze the BP implant survivorship at 10-year follow-up, make a subanalysis between patient groups, and evaluate long-term functional outcomes. METHODS: Data of 86 patients who received 101 BP implants between 1993 and 2010 were obtained from a prospectively documented database. Subanalyses were done for patients diagnosed with inflammatory joint disease and noninflammatory joint disease, and patients with preoperative tibiotalar neutral and nonneutral alignment. A Kaplan-Meier curve was used for survival analysis. Long-term functional outcomes were assessed with the following patient-reported outcome measures: Foot and Ankle Outcome Score (FAOS), Foot and Ankle Ability Measure (FAAM), Short Form-36 (SF-36) Stand Version 2.0 Health Survey and 3 anchor questions. RESULTS: The survival rate of the BP implant at 10 years was 86% (95% confidence interval, 78%-93%). A total of 31 patients (36%) required 55 reoperations, and in 13 patients (15%) a revision procedure was performed. In this series, no significant difference in 10-year survival rate was found between neither the inflammatory joint disease and noninflammatory joint disease group ( P = .47), nor the tibiotalar neutral and nonneutral alignment group ( P = .16). At a mean follow-up of 16.8 years for 21 patients, the mean FAOS activities of daily living (ADL) and FAAM ADL subscale scores were 75/100 and 56/100 points. The mean physical component summary (PCS) and mental component summary (MCS) of the SF-36 were 34/100 and 51/100 points, respectively. CONCLUSION: A survival rate of 86% was found at 10-year follow-up for the Buechel-Pappas implant. Our series demonstrated no significant difference in 10-year survival rates between the 2 patient subgroups. Long-term results of the various functional outcomes varied between poor and moderate. LEVEL OF EVIDENCE: Level II, prospective cohort study.


Assuntos
Articulação do Tornozelo/patologia , Articulação do Tornozelo/cirurgia , Artroplastia de Substituição do Tornozelo/instrumentação , Osteoartrite/cirurgia , Falha de Prótese/tendências , Reoperação/estatística & dados numéricos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Estudos Prospectivos , Desenho de Prótese
9.
Orthop J Sports Med ; 6(3): 2325967118759631, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29568784

RESUMO

BACKGROUND: Diagnosing an anterior cruciate ligament (ACL) rupture based on a physical examination remains a challenge for both surgeons and physical therapists. The lever sign test was developed to overcome the practical limitations of other tests and to optimize diagnosis. An evaluation of the measurement properties of the lever sign test is needed to make adequate interpretations in practice. PURPOSE: To evaluate the reliability and diagnostic value of the lever sign test. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: A total of 94 patients were recruited between November 2014 and July 2016. Patients were included if they were at least 16 years old, suffered from knee trauma, and had indications for knee arthroscopic surgery. Lever sign, anterior drawer, Lachman, and pivot-shift test outcomes were examined by an orthopaedic/trauma surgeon and a physical therapist. A test-retest design was used to investigate interrater reliability. Moreover, the lever sign test outcomes, alone and in combination with the other diagnostic tests, were compared with arthroscopic results, which served as the gold standard for the test's diagnostic value. RESULTS: The lever sign test and pivot-shift test had kappa values exceeding 0.80 for interrater reliability. The kappa values for the anterior drawer test and Lachman test were 0.80 and 0.77, respectively. The lever sign test showed the highest specificity (100%) and the lowest sensitivity (39%) when compared with the other 3 tests. Moreover, its positive and negative predictive values were 100% and 65%, respectively, while an accuracy of 71% was calculated. Clustering the lever sign test parallel with the other 3 tests resulted in the highest accuracy of 91%. CONCLUSION: The lever sign test appears to have high interrater reliability and is the most specific test, showing a maximal positive predictive value. A positive lever sign test result indicates an ACL rupture. These results support the added value of the lever sign test for diagnosing ACL ruptures.

10.
Hip Int ; 28(2): 115-121, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28967054

RESUMO

INTRODUCTION: An ongoing discussion is whether using a hydroxyapatite coating enhances the ingrowth and longevity of a femoral stem in total hip arthroplasty. The best way to predict speed of ingrowth and long-term outcome is by evaluating micromotion by radiostereometric analysis. To study the effect of hydroxyapatite (HA) coating on the migration of the SL-PLUS hip stem, we performed a prospective double blind randomised controlled trial comparing the early migration of the hydroxyapatite (HA)-coated SL-PLUS stem compared to the Standard (non-coated) SL-PLUS stem. PATIENTS AND METHODS: 51 patients were randomly assigned to receive either an uncoated or a HA-coated femoral component during total hip replacement. RSA images were obtained direct postoperatively and at 6 weeks, 12 weeks, 6 months, 12 months and 24 months. HOOS scores were obtained preoperative and at final follow-up. RESULTS: RSA evaluation demonstrated significant migration up to 3 months postoperatively in both groups. After initial setting no significant migration was observed. There was no significant difference in migration between the HA-coated group and the uncoated group. Both Harris Hip Score (HHS) and HOOS domain scores (pain and ADL) significantly improved compared to baseline at 24 months after surgery in both treatment groups (p<0.001 for all comparisons). Improvement did not differ significantly between the 2 groups. CONCLUSIONS: At 2 years follow-up, the HA-coated and uncoated Zweymuller type, distal fitting stem do not show different migration patterns.


Assuntos
Artroplastia de Quadril/métodos , Materiais Revestidos Biocompatíveis , Durapatita , Fêmur/cirurgia , Migração de Corpo Estranho/prevenção & controle , Prótese de Quadril , Idoso , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Falha de Prótese , Análise Radioestereométrica , Fatores de Tempo , Resultado do Tratamento
11.
Eur J Orthop Surg Traumatol ; 28(1): 79-84, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28656366

RESUMO

An eponym is a person after whom an eponymous term is named. These eponymous terms are easy shorthand in communication between surgeons. Therefore, they are often used and hard to eradicate. We discuss eponymous terms that describe anatomical features and fracture types in the knee. With these terms, an overview of the historical background of the eponym and its current clinical implication is discussed. The eponymous terms discussed are Gerdy tubercle, Pellegrini-Stieda lesion, Segond fracture, Hoffa fracture and fat pad. The meaning of the eponymous term is clarified, the biography of the namegiver given and its contemporary clinical implication discussed. Since eponymous terms are used frequently in inter-collegial discussion and literature, the meaning should be clear for everyone, since otherwise it might give room for misunderstanding.


Assuntos
Anatomia/história , Epônimos , Fraturas do Fêmur/história , Artropatias/história , Terminologia como Assunto , Fraturas da Tíbia/história , França , Alemanha , História do Século XVIII , História do Século XIX , História do Século XX , Humanos , Itália , Joelho/anatomia & histologia , Procedimentos Ortopédicos/história
12.
Arch Orthop Trauma Surg ; 136(7): 1007-14, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27139185

RESUMO

After the low friction arthroplasty by John Charnley was no longer confined to specialized hospitals but commonplace in the general orthopedic practice, the issue remained how to most optimally reach the hip. The names of the authors of these approaches remain in a lot of cases connected to the approach. By evaluating the original articles in which the approaches are described we ascertain the original description and technique. By various sources we obtained the (short) biography of the people whose name is connected to the approach. Our research covers the biographies of colleagues Smith-Petersen, Watson-Jones, Hardinge, Charnley, Moore and Ludloff. The eponymous approaches are shown and described after the short biography on each individual. This study shows that without the work of our colleagues we cannot proceed in our profession. An understanding and knowledge of the people who dedicated themselves to developing the orthopedic surgery to the high standard it has today is the least honour we should give them.


Assuntos
Artroplastia de Quadril/história , Articulação do Quadril/cirurgia , Procedimentos Ortopédicos/história , Artroplastia de Quadril/métodos , Epônimos , História do Século XIX , História do Século XX , Humanos , Masculino , Ortopedia
14.
J Shoulder Elbow Surg ; 24(3): 369-75, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25595361

RESUMO

Eponyms are common in medicine and in orthopaedic surgery. For future reference and historical considerations, we present common eponyms in elbow fracture surgery. We describe in short the biography of the name giver and give, where possible, the original description on which the eponym was based. Whether eponyms should continue to be used is a question that remains unanswered, but if we use them, knowledge of the original description can prevent confusion and knowledge of the historical background sheds light on the interesting roots of our profession.


Assuntos
Lesões no Cotovelo , Articulação do Cotovelo/cirurgia , Epônimos , Fixação Interna de Fraturas/história , Fraturas Ósseas/história , Fraturas Ósseas/diagnóstico , Fraturas Ósseas/cirurgia , História do Século XIX , História do Século XX , Humanos
15.
J Am Podiatr Med Assoc ; 104(3): 287-90, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24901589

RESUMO

We present a case of a snowboard injury that caused a combination of a complete deltoid and anterior talofibular ligament rupture, without bony or syndesmotic injury. Initial surgical repair for both ligaments was performed. We describe the etiology of this injury to demonstrate the cause and existence of medial and lateral ankle ligament rupture without osseous and syndesmotic involvement and to create awareness of these types of injuries.


Assuntos
Traumatismos do Tornozelo/cirurgia , Músculo Deltoide/lesões , Ligamentos Laterais do Tornozelo/lesões , Ligamentos Articulares/transplante , Procedimentos de Cirurgia Plástica/métodos , Esqui/lesões , Traumatismos do Tornozelo/diagnóstico por imagem , Traumatismos do Tornozelo/etiologia , Músculo Deltoide/cirurgia , Seguimentos , Humanos , Escala de Gravidade do Ferimento , Ligamentos Laterais do Tornozelo/cirurgia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Traumatismo Múltiplo/diagnóstico , Traumatismo Múltiplo/cirurgia , Procedimentos Ortopédicos/métodos , Amplitude de Movimento Articular/fisiologia , Recuperação de Função Fisiológica , Medição de Risco , Ruptura/diagnóstico , Ruptura/cirurgia , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
17.
J Bone Oncol ; 2(1): 30-2, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26909269

RESUMO

In 2007 a 9½-year-old boy was treated with resection, extracorporeal irradiation and re-implantation of the right scapula. He also received chemotherapy. During five year follow-up shoulder function remained largely intact. Subtotal resorption of the scapula occurred, leaving only the glenohumeral joint intact. Sensibility and strength are intact. To date there is no sign of local or metastatic recurrence.

19.
Dig Surg ; 27(4): 279-84, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20689288

RESUMO

AIM: This study was designed to determine the effect of treating hemorrhoids with the Doppler-guided hemorrhoidal artery ligation (DG-HAL) procedure. METHODS: From June 2005 to March 2008, 244 consecutive hemorrhoidal patients underwent hemorroidal artery ligation performed with the DG-HAL system from AMI. All patients were evaluated postoperatively with a proctologic examination and interview. Further follow-up was performed by telephone with a standardized questionnaire. When indicated, patients revisited the clinic for further examination and treatment. RESULTS: 244 patients were treated with DG-HAL. The mean follow-up time was 18.4 months (range 1.4-37.2). Sixty-seven percent of the patients had an improvement of symptoms after one treatment. Fifty-three patients (22%) underwent a second procedure because of persisting symptoms. Thirteen patients (25%) underwent a second DG-HAL and 40 (75%) underwent rubber band ligation. In total, 69% of the patients had a good response using the DG-HAL technique. Multivariate logistic regression analysis revealed prolapse to be an independent risk factor for persistent symptoms (OR = 2.38, 95% CI 1.10-5.15). Patients with grades 3 and 4 hemorrhoids had a higher risk of developing recurrent disease (OR = 4.94, 95% CI 0.67-36.42). CONCLUSION: DG-HAL seems to be an effective procedure for treating low-grade hemorrhoids. A resection procedure should be the treatment for patients with recurrent disease.


Assuntos
Hemorroidas/diagnóstico por imagem , Hemorroidas/cirurgia , Reto/irrigação sanguínea , Procedimentos Cirúrgicos Vasculares/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artérias/diagnóstico por imagem , Artérias/cirurgia , Estudos de Coortes , Feminino , Humanos , Tempo de Internação , Ligadura/métodos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Análise Multivariada , Dor Pós-Operatória/fisiopatologia , Satisfação do Paciente , Reto/cirurgia , Recidiva , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Resultado do Tratamento , Ultrassonografia Doppler , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA