RESUMO
Aims: The optimal bearing surface design for medial unicompartmental knee arthroplasty (UKA) remains controversial. The aim of this study was to compare outcomes of fixed-bearing (FB) and mobile-bearing (MB) UKAs from a single high-volume institution. Methods: Prospectively collected data were reviewed for all primary cemented medial UKAs performed by seven surgeons from January 2006 to December 2022. A total of 2,999 UKAs were identified, including 2,315 FB and 684 MB cases. The primary outcome measure was implant survival. Secondary outcomes included 90-day and cumulative complications, reoperations, component revisions, conversion arthroplasties, range of motion, and patient-reported outcome measures. Overall mean age at surgery was 65.7 years (32.9 to 94.3), 53.1% (1,593/2,999) of UKAs were implanted in female patients, and demographics between groups were similar (p > 0.05). The mean follow-up for all UKAs was 3.7 years (0.0 to 15.6). Results: Using revision for any reason as an endpoint, five-year survival for FB UKAs was 97.2% (95% CI 96.4 to 98.1) compared to 96.0% for MB (95% CI 94.1 to 97.9; p = 0.008). The FB group experienced fewer component revisions (14/2,315, 0.6% vs 12/684, 1.8%; p < 0.001) and conversion arthroplasties (38/2315, 1.6% vs 24/684, 3.5%; p < 0.001). A greater number of MB UKAs underwent revision due to osteoarthritis progression (FB = 21/2,315, 0.9% vs MB = 16/684, 2.3%; p = 0.003). In the MB group, 12 (1.8%) subjects experienced bearing dislocations which required revision surgery. There were 15 early periprosthetic tibia fractures (0.6%) in the FB group compared to 0 for MB (p = 0.035). Conclusion: In similar patient populations, FB UKAs demonstrated slightly higher survival than a commonly used MB design. Adverse event profiles differed by bearing type, with an increased risk of bearing dislocation and OA progression with MB designs, and early periprosthetic tibia fractures for FB designs.
Assuntos
Artroplastia do Joelho , Prótese do Joelho , Desenho de Prótese , Falha de Prótese , Reoperação , Humanos , Feminino , Artroplastia do Joelho/métodos , Masculino , Idoso , Pessoa de Meia-Idade , Reoperação/estatística & dados numéricos , Idoso de 80 Anos ou mais , Adulto , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular , Resultado do Tratamento , Estudos Retrospectivos , Complicações Pós-Operatórias/epidemiologia , Medidas de Resultados Relatados pelo Paciente , Estudos ProspectivosRESUMO
BACKGROUND: Advances in total hip arthroplasty (THA) have resulted in evolving revision indications and intraoperative techniques, which can influence the exposure of trainees to complex cases. We report 3 decades of revision experience from a tertiary referral center that trains fellows, comparing the reasons for revision and the complexity of revisions over time. METHODS: We retrospectively reviewed all revision THAs performed at our institution from 1990 to 2022. Revision diagnoses, components revised, types of revision implants used, and exposure techniques were collected. A "complex" revision was defined as a case that involved an extended trochanteric osteotomy, triflange and cup-cage construct, or acetabular augment. RESULTS: A total of 3,556 THA revisions were identified (108 revisions/year). Aseptic loosening was the most common indication in 1990 to 1999 (45 per year), but decreased to 28.3/year in 2010 to 2019. From 1990 to 1999 and 2010 to 2019, fracture increased from 3.1 to 7.3 per year, infection from 2.9/year to 16.9/year, and metallosis from 0.1 to 13.2 per year. Both component revision were common from 1990 to 1994 (42.6 per year), while polyethylene exchange was most common in 2010 to 2019 (43.3 per year). A decrease was observed in "complex" cases over time: 14.8 extended trochanteric osteotomies/year in 2000 to 2004 compared to 5.4 per year in 2018 to 2022, 4.5 triflange and cup-cage constructs/year in 2004 to 2007 compared to 0.8 per year in 2018 to 2022, and 4 acetabular augments per year in 2009 to 2012 compared to 1 per year in 2018 to 2022. CONCLUSIONS: Indications for revision have changed over the decades, while the number of "complex" revisions has gradually decreased, presumably due to advances in implants and materials. If this trend extends to other training institutions, the next generation of arthroplasty surgeons will have less exposure to complex revisions during their training.
Assuntos
Artroplastia de Quadril , Distinções e Prêmios , Falha de Prótese , Reoperação , Humanos , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Masculino , Feminino , Prótese de Quadril , Pessoa de Meia-Idade , IdosoRESUMO
Aims: The first aim of this study was to evaluate whether preoperative renal function is associated with postoperative changes in whole blood levels of metal ions in patients who have undergone a Birmingham Hip Resurfacing (BHR) arthroplasty with a metal-on-metal bearing. The second aim was to evaluate whether exposure to increased cobalt (Co) and chromium (Cr) levels for ten years adversely affected renal function. Methods: As part of a multicentre, prospective post-approval study, whole blood samples were sent to a single specialized laboratory to determine Co and Cr levels, and the estimated glomerular filtration rate (eGFR). The study included patients with 117 unrevised unilateral BHRs. There were 36 females (31%). The mean age of the patients at the time of surgery of 51.3 years (SD 6.5), and they all had preoperative one-, four-, five-, and ten-year laboratory data. The mean follow-up was 10.1 years (SD 0.2). Results: Median Co levels at one year postoperatively increased significantly compared with the preoperative values, by a factor of 9.7, from 0.13 to 1.26 ppb (p < 0.001), and the median Cr levels increased significantly by a factor of 2.5, from 0.60 to 1.50 ppb (p < 0.001). Lower preoperative eGFRs were associated with significantly larger increases in Co at one year compared with the preoperative levels (ρ = -0.26; p = 0.005), but there was no relationship between preoperative eGFRs and changes in Cr at one year (ρ = -0.13; p = 0.153). Metal levels remained relatively constant with the passage of time, with a median ten-year value of 1.12 ppb for Co and 1.29 ppb for Cr. There was no significant relationship between the Co and Cr levels at ten-year follow-up and the change in eGFR from the preoperative level to that at ten years (ρ = -0.02; p = 0.827 for Co; ρ = -0.008; p = 0.933 for Cr). Conclusion: Although patients with lower preoperative eGFRs tended to have larger increases in Co levels at one year, increased metal levels for patients who underwent unilateral BHR did not adversely affect renal function during the first ten postoperative years.
Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Feminino , Humanos , Pessoa de Meia-Idade , Prótese de Quadril/efeitos adversos , Taxa de Filtração Glomerular , Estudos Prospectivos , Próteses Articulares Metal-Metal/efeitos adversos , Desenho de Prótese , Metais , Cobalto , CromoRESUMO
BACKGROUND: Infection following total knee arthroplasty (TKA) remains a challenging clinical problem. Using American Joint Replacement Registry data, this study examined factors related to the incidence and timing of infection. METHODS: Primary TKAs performed from January 2012 through December 2018 among patients ≥65 years of age at surgery were queried from the American Joint Replacement Registry and merged with Medicare data to enhance capture of revisions for infection. Multivariate Cox regressions incorporating patient, surgical, and institutional factors were used to produce hazard ratios (HRs) associated with revision for infection and mortality after revision for infection. RESULTS: Among 525,887 TKAs, 2,821 (0.54%) were revised for infection. Men had an increased risk of revision for infection at all-time intervals (≤90 days, HR = 2.06, 95% CI: 1.75-2.43, P < .0001; >90 days to 1 year, HR = 1.90, 95% CI: 1.58-2.28, P < .0001; >1 year, HR = 1.57, 95% CI: 1.37-1.79, P < .0001). TKAs performed for osteoarthritis had an increased risk of revision for infection at ≤90 days (HR = 2.01, 95% CI: 1.45-2.78, P < .0001) but not at later times. Mortality was more likely among patients who had a Charlson Comorbidity Index (CCI) ≥ 5 compared to those who had a CCI ≤ 2 (HR = 3.21, 95% CI: 1.35-7.63, P = .008). Mortality was also more likely among older patients (HR = 1.61 for each decade, 95% CI: 1.04-2.49, P = .03). CONCLUSION: Based on primary TKAs performed in the United States, men were found to have a persistently higher risk of revision for infection, while a diagnosis of osteoarthritis was associated with a significantly higher risk only during the first 90 days after surgery.
Assuntos
Artroplastia do Joelho , Artroplastia de Substituição , Prótese do Joelho , Osteoartrite do Joelho , Masculino , Humanos , Idoso , Estados Unidos/epidemiologia , Artroplastia do Joelho/efeitos adversos , Dados de Saúde Coletados Rotineiramente , Reoperação , Falha de Prótese , Medicare , Osteoartrite do Joelho/cirurgia , Osteoartrite do Joelho/etiologia , Sistema de Registros , Fatores de Risco , Prótese do Joelho/efeitos adversosRESUMO
Crosslinking substantially reduces the wear of ultra-high molecular weight polyethylene (UHMWPE) used in total hip arthroplasty (THA) but some reports have indicated that first generation liners manufactured without antioxidants may be vulnerable to in vivo oxidation. This study evaluated maximum oxidation using Fourier transform infrared spectroscopy per ASTM F2102-06ε1 and linear head penetration using a coordinate measuring machine among 66 revision-retrieved THA components with in vivo durations ranging from 0.02 to 24.6 years. These included 30 liners crosslinked with 5 Mrad of gamma radiation and then melted, 13 non-crosslinked, never-irradiated liners sterilized with gas plasma and 23 non-crosslinked, never-irradiated liners sterilized with ethylene oxide. All liners were vacuum-sealed and stored at -20°C prior to analysis with the exception of three retrievals of each material type that were stored in air for 9.9 to 21.5 years. All 57 vacuum-sealed and frozen retrievals demonstrated good oxidative stability with maximum oxidation indices (OIs) less than 1.0 and 75% (43/57) of these liners had maximum OIs less than 0.1. Linear penetration measurements were lower in the crosslinked liners compared to non-crosslinked retrievals. Although instances of oxidation and embrittlement were found after ex vivo storage in air among liners that did not have free radicals at the time of implantation, in vivo oxidation does not appear to be a clinical concern through the first decade of service for crosslinked liners and at up to 25 years after surgery for non-crosslinked liners.
Assuntos
Artroplastia de Quadril , Prótese de Quadril , Radicais Livres , Humanos , Polietileno/química , Polietilenos/química , Desenho de Prótese , Falha de Prótese , ReoperaçãoRESUMO
BACKGROUND: One purported benefit of the direct anterior approach (DAA) for total hip arthroplasty (THA) is a lower rate of postoperative dislocation. METHODS: An institutional database was used to identify 8840 primary THAs performed from 2003 to 2020 including 5065 (57%) performed using the DAA and 3775 (43%) performed via the posterior approach (PA). Direction and mechanism of dislocation were determined from chart review. Outcomes were compared using Kaplan-Meier survivorship with dislocation as the endpoint and a Cox multivariate regression was used to investigate factors associated with dislocation. The mean follow-up was 1.7 ± 2.0 years for the DAA and 3.1 ± 3.3 years for the PA. RESULTS: The 0.5% (26/5065) incidence of dislocation among DAA hips was significantly less than the 3.3% (126/3775) among PA cases (P < .001). The majority of dislocations were posterior (DAA 57%, PA 79%) and occurred during activities of daily living (DAA 82%, PA 77%). Five-year survivorship was significantly higher for the DAA group compared to the PA group (99.1% vs 95.4%, P < .001). Dislocation risk was 4.9 times higher for the PA compared to the DAA (hazard ratio = 4.9, 95% confidence interval = 3.2-7.5, P < .001). Increasing head diameter reduced the risk (hazard ratio = 0.70, 95% confidence interval = 0.57-0.86, P < .001). The 0.2% incidence (10/5065) of revision for instability among the DAA group was significantly lower than the 1.1% (43/3775) rate for the PA group (P < .001). CONCLUSION: Compared to primary THAs performed with the PA, DAA cases had a lower risk of dislocation, higher survivorship with dislocation as an endpoint, and a lower risk of revision for instability in this single institution cohort.
Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Atividades Cotidianas , Artroplastia de Quadril/efeitos adversos , Luxação do Quadril/epidemiologia , Luxação do Quadril/etiologia , Luxação do Quadril/prevenção & controle , Humanos , Reoperação , Estudos RetrospectivosRESUMO
BACKGROUND: Revision total hip arthroplasty with modular component exchange can limit morbidity by retaining well-fixed components but dislocation has been a relatively frequent postoperative complication. This study evaluated the effect of surgical approach on dislocation rate in a modern revision cohort. METHODS: From 2010 to 2020, 248 aseptic head and liner exchanges were performed at a single institution. The mean patient age at revision was 64.9 ± 10.4 years and 50% (123/248) were performed among males. Indications for revision included 140 (56%) for polyethylene wear, 68 (27%) for failed metal-on-metal components, and 40 (16%) for instability. The mean follow-up after revision was 2.3 years. RESULTS: Thirty (12%) hips dislocated at a mean of 0.6 years (range 0.01-4.6) postoperatively. The dislocation rate by revision approach was 17% (9/54) for the direct anterior, 6% (5/80) for the direct lateral, and 14% (16/114) for the posterolateral approach (P = .13). Hips revised by the direct anterior approach that dislocated were more abducted (51 ± 8 vs 45 ± 8, P = .05) and more anteverted (26 ± 9 vs 20 ± 7, P = .04) than non-dislocators. Among all 248 hips, cups with more than 48° of abduction were 2.6 times more likely to dislocate (P = .01). Head diameter, neck length, patient age, and gender were not associated with dislocation (P ≥ .20). CONCLUSION: Dislocation remains a common complication after head and liner exchange regardless of approach. Cup position is associated with postoperative instability and must be critically evaluated during preoperative planning.
Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Luxação do Quadril/epidemiologia , Luxação do Quadril/etiologia , Luxação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Polietileno , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos RetrospectivosRESUMO
PURPOSE: Accurate component placement and restoration of patient anatomy are critical in total hip arthroplasty (THA) surgery. Although intraoperative radiographs are sometimes utilized, it is unclear whether this practice can improve accuracy. MATERIALS AND METHODS: This study evaluated acetabular cup abduction, anteversion, leg length, and offset among 100 posterior approach THAs performed without imaging (No X-ray group) and compared them to a subsequent series of 100 THAs where an intraoperative radiograph was taken with the trial components in place (X-ray group). THAs were performed using a posterior approach by a single, experienced surgeon whose goal was to place the cup at 45° of abduction and 30° of anteversion. Supine anteroposterior pelvic digital radiographs taken at the first (nominal 4-week) postoperative visit were used for measurements. RESULTS: Slight differences in cup abduction (47°±6° vs 44°±6°, respectively, P=0.003) and anteversion angle (35°±6° vs 31°±6°, respectively, P<0.001) were observed between the X-ray and No X-ray groups; however, a similar proportion of cups within 10° of the target angles was observed (76% vs 83%, respectively, P=0.22). No difference in offset measurements (1.1±6.6 mm vs 0.3±6.9 mm, respectively, P=0.42) or leg lengths (0.3±3.8 mm vs 0.3±4.8 mm, respectively, P=0.94) was observed between the X-ray and No X-ray groups; however, the X-ray group showed less leg length variation (P=0.05). CONCLUSION: In this study, the routine use of intraoperative radiographs was not associated with improved implant positioning for uncomplicated primary THA.
RESUMO
BACKGROUND: The BIRMINGHAM HIP Resurfacing (BHR) system is a metal-on-metal hip implant system approved by the U.S. Food and Drug Administration in 2006. The approval required a multicenter, prospective, post-market-approval study. Our purpose is to report the current results at 10 years of follow-up. METHODS: Between October 2006 and December 2009, 280 primary BHR procedures were performed at 5 sites. Outcome measures included Kaplan-Meier survivorship, reasons for revision, radiographic component stability and osteolysis, Harris hip scores, and metal levels including cobalt and chromium. The mean age at the time of the procedure was 51.3 ± 7.1 years, 74% (206) of 280 BHRs were implanted in male patients, the mean body mass index was 27.8 ± 4.4 kg/m2, and 95% (265) of 280 hips had a primary diagnosis of osteoarthritis. The mean follow-up among all 280 hips was 9.0 ± 2.5 years. Prior to 10-year follow-up, 20 hips were revised and 5 patients representing 5 hips had died. Among the remaining 255 hips, 218 (85%) met the minimum follow-up of 10 years. RESULTS: The 10-year survival free from all-cause component revision was 92.9% (95% confidence interval [CI], 89.8% to 96.1%) for all hips and 96.0% (95% CI, 93.1% to 98.9%) among male patients <65 years old at the time of the procedure. Reasons for revision included femoral loosening (n = 5), femoral neck fracture (n = 3), pseudotumor (n = 3), osteolysis (n = 2), and acetabular loosening (n = 1), as well as 6 revisions for a combination of pain, noise, or metal levels. Among unrevised hips, the median Harris hip score improved from preoperatively (59) to 1 year postoperatively (99; p < 0.001) and remained stable through 10 years postoperatively (99; p = 0.08). Radiographically, 5% (10) of 218 unrevised hips had osteolysis with no component migration. Median metal levels had increased at 1 year postoperatively (cobalt: from 0.12 ppb preoperatively to 1.5 ppb at 1 year postoperatively, p < 0.001; chromium: from 0.6 ppb preoperatively to 1.7 ppb at 1 year postoperatively, p < 0.001), then remained stable through 5 years before slightly decreasing at 10 years postoperatively (cobalt: 1.3 ppb, p < 0.001; chromium: 1.4 ppb, p < 0.001). CONCLUSIONS: This prospective, multicenter, post-market-approval study demonstrated that the BHR implant system is safe and effective through 10 years of follow-up, particularly among young male patients. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril/efeitos adversos , Próteses Articulares Metal-Metal/efeitos adversos , Osteoartrite do Quadril/cirurgia , Falha de Prótese , Adulto , Idoso , Artroplastia de Quadril/efeitos adversos , Aprovação de Equipamentos , Feminino , Seguimentos , Prótese de Quadril/estatística & dados numéricos , Humanos , Masculino , Próteses Articulares Metal-Metal/estatística & dados numéricos , Pessoa de Meia-Idade , Estudos Prospectivos , Reoperação/estatística & dados numéricos , Resultado do Tratamento , Estados Unidos , United States Food and Drug Administration , Adulto JovemRESUMO
AIMS: The purpose of this study is to examine six types of bearing surfaces implanted at a single institution over three decades to determine whether the reasons for revision vary among the groups and how long it takes to identify differences in survival. METHODS: We considered six cohorts that included a total of 1,707 primary hips done between 1982 and 2010. These included 223 conventional polyethylene sterilized with γ irradiation in air (CPE-GA), 114 conventional polyethylene sterilized with gas plasma (CPE-GP), 116 crosslinked polyethylene (XLPE), 1,083 metal-on-metal (MOM), 90 ceramic-on-ceramic (COC), and 81 surface arthroplasties (SAs). With the exception of the COC, all other groups used cobalt-chromium (CoCr) femoral heads. The mean follow-up was 10 (0.008 to 35) years. Descriptive statistics with revisions per 100 component years (re/100 yr) and survival analysis with revision for any reason as the endpoint were used to compare bearing surfaces. RESULTS: XLPE liners demonstrated a lower cumulative incidence of revision at 15 years compared to the CPE-GA and CPE-GP groups owing to the absence of wear-related revisions (4% for XLPE vs 18%, p = 0.02, and 15%, p = 0.003, respectively). Revisions for adverse local tissue reactions occurred exclusively among the MOM (0.8 re/100 year) and SA groups (0.1 re/100 year). The revision rate for instability was lower among hips with 36 mm and larger head sizes compared to smaller head sizes (0.2% vs 2%, p < 0.001). CONCLUSION: The introduction of XLPE has eliminated wear-related revisions through 15-year follow-up compared to CPE-GP and CPE-GA. Dislocation incidence has been reduced with the introduction of larger diameter heads but remains a persistent concern. The potential for adverse local tissue reactions with MOM requires continued follow-up. Cite this article: Bone Joint J 2020;102-B(7 Supple B):105-111.
Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Desenho de Prótese , Falha de Prótese/tendências , Adulto , Idoso , Cerâmica , Ligas de Cromo , Estudos de Coortes , Seguimentos , Humanos , Instabilidade Articular/cirurgia , Masculino , Próteses Articulares Metal-Metal , Pessoa de Meia-Idade , Polietileno , Reoperação/estatística & dados numéricos , VirginiaRESUMO
BACKGROUND: The hypothetical association between health-care errors and the transition of the medical academic year has been termed the "July effect." Data supporting its existence are conflicting, particularly in orthopedic surgery, and prior studies have inappropriately grouped fellows with resident trainees. No studies to date have examined whether a training initiation effect exists among surgical fellows in adult reconstructive orthopedics. METHODS: This is a level IV retrospective cohort study reviewing 15,650 primary hip and knee arthroplasties performed from 2006 to 2016 at a single institution. Forty arthroplasty fellows were trained during this 10-year period. Primary outcome measures included intraoperative complications, additional procedures, revisions, and nonoperative complications within 90 days of surgery. These complication rates were analyzed by quarter of academic year and by temporal progression through three-month fellowship rotations. RESULTS: There were no differences in intraoperative complication, revision, or nonoperative complication rates between any academic quarter. There was a single statistically lower rate of additional procedures in the third quarter (1.2%) than in the fourth quarter (1.8%, P = .04). The most common complication in this subset was wound dehiscence for patients undergoing hip arthroplasty and stiffness for patients undergoing knee arthroplasty. There was no difference in complication rates during the first, second, or third month as fellows progressed through a single rotation. CONCLUSION: This study does not support the existence of a training-initiation effect among fellows in adult hip and knee reconstruction. Graduated autonomy can be safely employed in a fellowship program without negatively impacting patient outcomes, ensuring the continued high-caliber training of future surgeons.
Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Internato e Residência , Ortopedia , Adulto , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Bolsas de Estudo , Humanos , Ortopedia/educação , Estudos RetrospectivosRESUMO
BACKGROUND: To better define the optimal alignment target for medial fixed-bearing unicompartmental knee arthroplasty (UKA), this study compares the postoperative mechanical alignment of well-functioning UKAs against 2 groups of failed UKAs, including revisions for progression of lateral compartment osteoarthritis ("Progression") and revisions for aseptic loosening or subsidence ("Loosening"). METHODS: From our prospective institutional database of 3351 medial fixed-bearing UKAs performed since 2000, we identified 37 UKAs revised for Progression and 61 UKAs revised for Loosening. Each of these revision cohorts was matched based on age at surgery, gender, body mass index, and postoperative range of motion with unrevised UKAs that had at least 10 years of follow-up and a Knee Society Score of 70 or greater without subtracting points for alignment ("Success" groups). Postoperative alignment was quantified by the hip-knee-ankle (HKA) angle measured on long-leg alignment radiographs. RESULTS: The mean HKA angle at 4-month follow-up for the Progression group was 0.3° ± 3.6° of valgus compared to 4.4° ± 2.6° of varus for the matched Success group (P < 0.001). For the Loosening group, the mean HKA angle was 6.1° ± 3.1° of varus versus 4.0° ± 2.7° of varus for the matched Success group (P < 0.001). CONCLUSIONS: Patients with well-functioning UKAs at 10 years exhibited mild varus mechanical alignment of approximately 4°, whereas patients revised for progression of osteoarthritis averaged more valgus and those revised for loosening or subsidence averaged more varus. The optimal mechanical alignment for medial fixed-bearing UKA survival with contemporary polyethylene is likely slight varus.
Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Estudos Prospectivos , Estudos Retrospectivos , Resultado do TratamentoRESUMO
BACKGROUND: Crosslinked polyethylene (XLPE) liners used for primary THA have demonstrated lower wear rates than noncrosslinked, conventional polyethylene (CPE) liners through the first decade of clinical service. However, little high-quality evidence is currently available regarding the second decade performance of these implants and it remains uncertain whether the onset of osteolysis has simply been delayed or if the wear associated with XLPE liners will remain low enough that osteolysis will not occur. It is also unknown how the potential reductions in wear and osteolysis will influence long-term revision rates. QUESTIONS/PURPOSES: Do patients who underwent THA with XLPE liners demonstrate (1) a lower rate of revision for wear-related complications; (2) a reduced wear rate; and (3) a lower frequency of osteolysis compared with those with CPE liners? METHODS: Over an 18-month period from 1999 to 2000, 226 patients who had 236 primary THAs consented to participate in a randomized controlled trial conducted at one institution. To be eligible for intraoperative randomization, patients had to be implanted with a 28-mm cobalt-chrome alloy femoral head, a 4-mm lateralized liner, and the same cup and stem design. Six patients with six THAs were excluded intraoperatively because they did not receive study components for reasons unrelated to the liner material. The remaining 230 THAs among 220 patients were randomized to XLPE liners or CPE liners. The mean age at surgery was 62 ± 11 years and there were no differences in age, gender, or body mass index among the groups. There was no differential loss to followup between the study groups; among patients not known to be deceased or having undergone revision, minimum 14-year radiographic followup is available for 85 THAs including 46 with XLPE and 39 with CPE liners. Polyethylene wear was measured radiographically using Martell's Hip Analysis Suite and areas of osteolysis were evaluated before revision or at most recent followup. Revision rates at 15 years using reoperation for any reason and revision for wear or osteolysis were calculated using cumulative incidence considering patient death as a competing risk. RESULTS: The cumulative incidence of revision at 15 years using reoperation for wear-related complications as an endpoint was lower in the XLPE group than the CPE group (0%, 95% confidence interval [CI], 0%-0% versus 12%, 95% CI, 7%-19%; p < 0.001). Among unrevised THAs with minimum 14-year radiographic followup, the mean steady-state linear wear rate for THAs with XLPE liners was lower than the mean linear wear rate for the THAs with CPE liners (0.03 ± 0.05 versus 0.17 ± 0.09 mm/year; mean difference, 0.14; 95% CI, 0.11-0.17; p < 0.001). Osteolysis of any size was noted among 9% (four of 46) of the hips in the XLPE group and 46% (18 of 39) of the hips in the CPE group (odds ratio, 0.19; 95% CI, 0.07-0.51; p < 0.001). CONCLUSIONS: This randomized study with followup into the second decade demonstrated reductions in revision, wear, and osteolysis associated with the use of XLPE. The low wear rates and absence of any mechanical failures among the XLPE liners at long-term followup affirm the durability of these components that did not incorporate antioxidants. Although osteolysis has not been eliminated, it occurs infrequently and has not caused any clinical problems to date. LEVEL OF EVIDENCE: Level I, therapeutic study.
Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Reagentes de Ligações Cruzadas/química , Articulação do Quadril/cirurgia , Prótese de Quadril , Osteólise/prevenção & controle , Polietileno/química , Falha de Prótese , Idoso , Feminino , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise/diagnóstico por imagem , Osteólise/etiologia , Osteólise/cirurgia , Estudos Prospectivos , Desenho de Prótese , Fatores de Proteção , Reoperação , Fatores de Risco , Estresse Mecânico , Fatores de Tempo , Resultado do Tratamento , VirginiaRESUMO
BACKGROUND: Scrutiny from the federal government and the media regarding the safety of 1 surgeon doing cases in 2 operating rooms (ORs) on the same day, prompted us to examine our own institutional data. Over the past 11 years, surgeons at our facility have operated consecutively in 1 OR on a given day or used 2 alternating ORs. This study compares these cases with a focus on revisions and complications in both groups. METHODS: Six surgeons performed a total of 16,916 primary hip and knee arthroplasties from 2006-2016. 7002 cases (41%) were consecutive cases (CCs) and 9914 cases (59%) were overlapping cases (OCs). Intraoperative complications, component revisions, and postoperative complications within 90 days of surgery were compared between the CC and OC groups. RESULTS: There was no difference in intraoperative complication rates between the two groups (CC 1.6% vs. OC 1.7%, relative risk 1.082, 95% confidence interval 0.852 to 1.375, P = .52). There was no difference in 90-day component revision rates among the CC and OC groups (0.66% vs. 0.85% respectively, relative risk = 1.290, 95% confidence interval 0.901 to 1.845, P = .19). There was also no difference in 90-day complication rates among the CC and OC groups (1.33% vs. 1.45% respectively, relative risk = 1.094, 95% confidence interval 0.844 to 1.417, P = .54). CONCLUSION: This large study of a single institution with multiple surgeons over an 11-year period shows no compromise in patient safety or outcomes when comparing cases done in either consecutive or overlapping rooms.
Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Salas Cirúrgicas/organização & administração , Segurança do Paciente , Admissão e Escalonamento de Pessoal , Complicações Pós-Operatórias/etiologia , Adulto , Idoso , Distinções e Prêmios , Índice de Massa Corporal , Feminino , História do Século XXI , Humanos , Complicações Intraoperatórias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Ortopedia/história , Estudos Retrospectivos , Fatores de Risco , CirurgiõesRESUMO
BACKGROUND: Length of stay after total hip arthroplasty (THA) has decreased over the last two decades. However, published studies that have examined same-day and early discharge protocols after THA have been done in highly selected patient groups operated on by senior surgeons in a nonrandomized fashion without control subjects. QUESTIONS/PURPOSES: The purpose of this study was to evaluate and compare patients undergoing THA who are discharged on the same day as the surgery ("outpatient," less than 12-hour stay) with those who are discharged after an overnight hospital stay ("inpatient") with regard to the following outcomes: (1) postoperative pain; (2) perioperative complications and healthcare provider visits (readmission, emergency department or physician office); and (3) relative work effort for the surgeon's office staff. METHODS: A prospective, randomized study was conducted at two high-volume adult reconstruction centers between July 2014 and September 2015. Patients who were younger than 75 years of age at surgery, who could ambulate without a walker, who were not on chronic opioids, and whose body mass index was less than 40 kg/m2 were invited to participate. All patients had a primary THA performed by the direct anterior approach with spinal anesthesia at a hospital facility. Study data were evaluated using an intention-to-treat analysis. A total of 220 patients participated, of whom 112 were randomized to the outpatient group and 108 were randomized to the inpatient group. Of the 112 patients randomized to outpatient surgery, 85 (76%) were discharged as planned. Of the remaining 27 patients, 26 were discharged after one night in the hospital and one was discharged after two nights. Of the 108 patients randomized to inpatient surgery with an overnight hospital stay, 81 (75%) were discharged as planned. Of the remaining 27 patients, 18 met the discharge criteria on the day of their surgery and elected to leave the same day, whereas nine patients stayed two or more nights. RESULTS: On the day of surgery, there was no difference in visual analog scale (VAS) pain among patients who were randomized to discharge on the same day and those who were randomized to remain in the hospital overnight (outpatient 2.8 ± 2.5, inpatient 3.3 ± 2.3, mean difference -0.5, 95% confidence interval [CI], -1.1 to 0.1, p = 0.12). On the first day after surgery, outpatients had higher VAS pain (at home) than inpatients (3.7 ± 2.3 versus 2.8 ± 2.1, mean difference 0.9, 95% CI, 0.3-1.5, p = 0.005). With the numbers available, there was no difference in the number of reoperations, hospital readmissions without reoperation, emergency department visits without hospital readmission, or acute office visits. At 4-week followup, there was no difference in the number of phone calls and emails with the surgeon's office (outpatient: 2.4 ± 1.9, inpatient: 2.4 ± 2.2, mean difference 0, 95% CI, -0.5 to 0.6, p = 0.94). CONCLUSIONS: Outpatient THA can be implemented in a defined patient population without requiring additional work for the surgeon's office. Because 24% (27 of 112) of patients planning to have outpatient surgery were not able to be discharged the same day, facilities to accommodate an overnight stay should be available. LEVEL OF EVIDENCE: Level I, therapeutic study.
Assuntos
Procedimentos Cirúrgicos Ambulatórios , Artroplastia de Quadril , Distinções e Prêmios , Articulação do Quadril/cirurgia , Pacientes Internados , Admissão do Paciente , Adulto , Idoso , Procedimentos Cirúrgicos Ambulatórios/efeitos adversos , Artroplastia de Quadril/efeitos adversos , Serviço Hospitalar de Emergência , Feminino , Articulação do Quadril/fisiopatologia , Hospitais com Alto Volume de Atendimentos , Humanos , Análise de Intenção de Tratamento , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Visita a Consultório Médico , Medição da Dor , Dor Pós-Operatória/etiologia , Alta do Paciente , Readmissão do Paciente , Philadelphia , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Virginia , Carga de TrabalhoRESUMO
This study compared the femoral stem revision and loosening rates in primary total hip arthroplasty between 2 different approaches and stem designs. Recent reports comparing the direct anterior approach with either the posterior or lateral approach showed that patients undergoing the direct anterior approach have less pain and an accelerated functional recovery in the early postoperative period. After converting to an anterior approach, the authors observed an increased rate of femoral stem revision. From 2003 to 2009, a posterior or lateral approach was used to insert 514 stems of 2 designs. These cases included the use of an extensively coated cobalt-chrome stem (n=232) or a straight, dual-tapered, proximally porous-coated titanium stem (n=282). In the following years, from 2009 to 2012, 594 short, proximally coated, titanium tapered-wedge stems were inserted through a direct anterior approach. The revision rates of femoral stems inserted through a posterior approach or a lateral approach were compared with those inserted via a direct anterior approach. No stem revisions occurred in the posterior approach group or the lateral approach group, and 5 stems were revised in the anterior approach group for periprosthetic fracture or aseptic loosening (0.8%). Significantly more stem revisions occurred after the use of the new stem design and a direct anterior approach (P=.04).
Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Desenho de Prótese , Reoperação , Adulto , Idoso , Idoso de 80 Anos ou mais , Ligas de Cromo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Titânio , Adulto JovemRESUMO
Adverse reaction to metal debris (ARMD) involving the hip joint has emerged as an important reason for failure and revision among patients with metal-on-metal (MOM) hip arthroplasty. To the authors' knowledge, there are no reports of adverse radiographic sequelae in the greater trochanter subsequent to revision for ARMD. The authors describe clinical and radiographic findings in 2 patients who developed greater trochanteric fragmentation 1 to 2 years after conversion of their failed MOM hips to polyethylene bearings. Both patients had solid pseudotumors with tissue necrosis. Several reports describe various clinical features of ARMD. Although poor outcomes have been demonstrated after some MOM revisions, to the authors' knowledge, no reports document greater trochanter fragmentation in ARMD. The current patients highlight the fact that tissue damage occurring with MOM bearing hips can involve bone in addition to soft tissue even after a pseudotumor has been removed and serum metal levels have decreased to normal levels after revision. Unlike the greater trochanteric fractures historically associated with polyethylene wear and osteolysis, no evidence of bone cysts or lesions was found prior to the fractures and neither fracture healed with conservative treatment. For these 2 patients, the authors believe the tissue necrosis included both soft tissue and bone. The necrotic bone resorbed gradually after removal of the MOM bearing, resulting in bone fragmentation with ongoing symptoms. These patients emphasize and remind us that damage is not only limited to soft tissues, but also includes bone. Surgeons should be aware of this radiographic finding and the associated clinical symptoms.
Assuntos
Artroplastia de Quadril/instrumentação , Necrose da Cabeça do Fêmur/etiologia , Fraturas do Quadril/etiologia , Prótese de Quadril/efeitos adversos , Metais/efeitos adversos , Osteoartrite do Quadril/cirurgia , Falha de Prótese , Feminino , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Necrose da Cabeça do Fêmur/cirurgia , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Polietilenos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Radiografia , Reoperação , Resultado do TratamentoRESUMO
Minimally invasive unicondylar arthroplasty (UKA) continues to gain popularity for the management of patients with degenerative arthritis limited to one compartment of the knee. In this study, we examine a series of 517 fixed-bearing, cemented unicompartmental knee components implanted in patients to manage degenerative arthritis in the medial compartment of their knee. All UKAs were performed at a single institution using the same fixed-bearing design. In this study we sought to examine the survivorship of the UKA components and the mechanisms of failure for the knees that were revised. The survivorship and revision rate with this implant were similar to those found in other published reports of fixed-bearing unicompartmental arthroplasties performed through minimally invasive surgical techniques.
Assuntos
Artroplastia do Joelho/métodos , Artropatias/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho , Falha de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Desenho de Prótese , Reoperação , Estudos RetrospectivosRESUMO
BACKGROUND: During the mid-1990s when our institution was using a press-fit porous-coated cup without supplemental initial fixation for primary THA, the manufacturer transitioned from gamma irradiation to gas plasma for the terminal sterilization of their polyethylene liners. QUESTIONS/PURPOSES: At minimum 10-year followup, we asked whether the fixation achieved by solely relying on a press-fit would be durable and how different liner sterilization methods affected radiographic wear, osteolysis, and survivorship. PATIENTS AND METHODS: We retrospectively reviewed 373 patients who underwent 398 primary THAs with a press-fit porous-coated cup between March 1995 and December 1996. Mean age at time of surgery was 61.5 ± 13.3 years and mean followup was 10.4 ± 3.7 years. We determined reasons for revision, survivorship, femoral head penetration, osteolysis, and wear-related complications. RESULTS: Among 20 revisions involving any component, seven were associated with wear and osteolysis. Kaplan-Meier survivorship, using component revision for any reason as an end point, was 95.7% (95% confidence interval, 93.6%-97.9%) at 10 years. Noncrosslinked liners sterilized with gas plasma demonstrated a mean head penetration rate of 0.20 ± 0.09 mm/year compared with 0.13 ± 0.07 mm/year for liners sterilized with gamma irradiation in air and 0.09 ± 0.04 mm/year for liners sterilized with gamma-irradiation with barrier packaging without oxygen. THAs with increased volumetric wear tended to demonstrate larger osteolytic lesions (r = 0.40) and there tended to be less osteolysis among the liners sterilized with gamma-irradiation with barrier packaging without oxygen. However, there was no difference in survivorship among the sterilization groups and there has been no cup or stem loosening associated with osteolysis. CONCLUSIONS: Durable biologic fixation through 10-year followup can be achieved by solely relying on an initial press-fit. Noncrosslinking gas plasma for terminal sterilization of the polyethylene liners was associated with greater head penetration rate than gamma irradiation. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.