1.
Artigo em Inglês | MEDLINE | ID: mdl-37372644

RESUMO

Firefighters are at an increased risk of cancer due to their occupational exposure to combustion byproducts, especially when those compounds penetrate the firefighter personal protective equipment (PPE) ensemble. This has led to questions about the impact of base layers (i.e., shorts vs. pants) under PPE ensembles. This study asked 23 firefighters to perform firefighting activities while wearing one of three different PPE ensembles with varying degrees of protection. Additionally, half of the firefighters unzipped their jackets after the scenario while the other half kept their jackets zipped for five additional minutes. Several volatile organic compound (VOC) and naphthalene air concentrations outside and inside of hoods, turnout jackets, and turnout pants were evaluated; biological (urinary and exhaled breath) samples were also collected. VOCs and naphthalene penetrated the three sampling areas (hoods, jackets, pants). Significant (p-value < 0.05) increases from pre- to post-fire for some metabolites of VOCs (e.g., benzene, toluene) and naphthalene were found. Firefighters wearing shorts and short sleeves absorbed higher amounts of certain compounds (p-value < 0.05), and the PPE designed with enhanced interface control features appeared to provide more protection from some compounds. These results suggest that firefighters can dermally absorb VOCs and naphthalene that penetrate the PPE ensemble.


Assuntos
Poluentes Ocupacionais do Ar , Bombeiros , Exposição Ocupacional , Hidrocarbonetos Policíclicos Aromáticos , Humanos , Poluentes Ocupacionais do Ar/análise , Naftalenos , Exposição Ocupacional/análise , Equipamento de Proteção Individual , Hidrocarbonetos Policíclicos Aromáticos/análise
2.
Int J Hyg Environ Health ; 248: 114095, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36508961

RESUMO

A plethora of chemicals are released into the air during combustion events, including a class of compounds called polycyclic aromatic hydrocarbons (PAHs). PAHs have been implicated in increased risk of cancer and cardiovascular disease, both of which are disease endpoints of concern in structural firefighters. Current commercially available personal protective equipment (PPE) typically worn by structural firefighters during fire responses have gaps in interfaces between the ensemble elements (e.g., hood and jacket) that allow for ingress of contaminants and dermal exposure. This pilot study aims to use silicone passive sampling to assess improvements in dermal protection afforded by a novel configuration of PPE, which incorporates a one-piece liner to eliminate gaps in two critical interfaces between pieces of gear. The study compared protection against parent and alkylated PAHs between the one-piece liner PPE and the standard configuration of PPE with traditional firefighting jacket and pants. Mannequins (n = 16) dressed in the PPE ensembles were placed in a Fireground Exposure Simulator for 10 min, and exposed to smoke from a combusting couch. Silicone passive samplers were placed underneath PPE at vulnerable locations near interfaces in standard PPE, and in the chamber air, to measure PAHs and calculate the dermal protection provided by both types of PPE. Silicone passive sampling methodology and analyses using gas chromatography with mass-spectrometry proved to be well-suited for this intervention study, allowing for the calculation and comparison of worker protection factors for 51 detected PAHs. Paired comparisons of the two PPE configurations found greater sum 2-3 ring PAH exposure underneath the standard PPE than the intervention PPE at the neck and chest, and at the chest for 4-7 ring PAHs (respective p-values: 0.00113, 0.0145, and 0.0196). Mean worker protection factors of the intervention PPE were also greater than the standard PPE for 98% of PAHs at the neck and chest. Notably, the intervention PPE showed more than 30 times the protection compared to the standard PPE against two highly carcinogenic PAHs, dibenzo[a,l]pyrene and benzo[c]fluorene. Nine of the detected PAHs in this study have not been previously reported in fireground exposure studies, and 26 other chemicals (not PAHs) were detected using a large chemical screening method on a subset of the silicone samplers. Silicone passive sampling appears to be an effective means for measuring dermal exposure reduction to fireground smoke, providing evidence in this study that reducing gaps in PPE interfaces could be further pursued as an intervention to reduce dermal exposure to PAHs, among other chemicals.


Assuntos
Poluentes Ocupacionais do Ar , Bombeiros , Exposição Ocupacional , Hidrocarbonetos Policíclicos Aromáticos , Humanos , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/análise , Poluentes Ocupacionais do Ar/análise , Silicones/análise , Projetos Piloto , Equipamento de Proteção Individual
3.
Fire Technol ; 59(6): 3255-3282, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38650825

RESUMO

Firefighters' or instructors' exposure to airborne chemicals during live-fire training may depend on fuels being burned, fuel orientation and participants' location within the structure. This study was designed to evaluate the impact of different control measures on exposure risk to combustion byproducts during fire dynamics training where fuel packages are mounted at or near the ceiling. These measures included substitution of training fuels (low density wood fiberboard, oriented strand board (OSB), pallets, particle board, plywood) and adoption of engineering controls such as changing the location of the instructor and students using the structure. Experiments were conducted for two different training durations: the typical six ventilation cycle (6-cycle) and a shorter three ventilation cycle (3-cycle) with a subset of training fuels. In Part A of this series, we characterized the fire dynamics within the structure, including the ability of each fuel to provide an environment that achieves the training objectives. Here, in Part B, airborne chemical concentrations are reported at the location where fire instructors would typically be operating. We hypothesized that utilizing a training fuel package with solid wood pallets would result in lower concentrations of airborne contaminants at the rear instructor location than wood-based sheet products containing additional resins and/or waxes. In the 6-cycle experiments (at the rear instructor location), OSB-fueled fires produced the highest median concentrations of benzene and 1,3 butadiene, plywood-fueled fires produced the highest total polycyclic aromatic hydrocarbon (PAH) concentrations, particle board-fueled fires produced the highest methyl isocyanate concentrations, and pallet-fueled fires produced the highest hydrogen chloride concentrations. All fuels other than particle board produced similarly high levels of formaldehyde at the rear instructor location. The OSB fuel package created the most consistent fire dynamics over 6-cycles, while fiberboard resulted in consistent fire dynamics only for the first three cycles. In the follow-on 3-cycle experiment, PAH, benzene, and aldehyde concentrations were similar for the OSB and fiberboard-fueled fires. Air sampling did not identify any clear differences between training fires from burning solid wood pallets and those that incorporate wood-based sheet products for this commonly employed fuel arrangement with fuels mounted high in the compartment. However, it was found that exposure can be reduced by moving firefighters and instructors lower in the compartment and/or by moving the instructor in charge of ventilation from the rear of the structure (where highest concentrations were consistently measured) to an outside position.

4.
Vet Surg ; 51(7): 1106-1110, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35815735

RESUMO

OBJECTIVE: To assess the effect of repeated freezing and thawing on the suture pull-out strength in arytenoid and cricoid cartilages subjected to the laryngoplasty (LP) procedure. STUDY DESIGN: Ex vivo experimental study. SAMPLE POPULATION: Ten grossly normal equine cadaveric larynges. METHODS: Bilateral LP constructs were created using a standard LP technique. One hemilarynx was randomly allocated to the single freeze and thaw group and the other allocated to the repeated freeze and thaw (3 complete cycles) group. The suture ends of each LP construct were attached to a load frame and subjected to monotonic loading until construct failure. Mean load (N) and displacement (mm) at LP construct failure were compared between groups. RESULTS: All LP constructs failed by suture pull through the arytenoid cartilage. The mean load at failure was similar between groups (118.9 ± 25.5 N in the single freeze and thaw group and 113.4 ± 20.5 N in the repeated freeze and thaw group, P = .62). The mean displacement at failure was similar between groups (54.4 ± 15.1 mm in the single freeze and thaw group and 54.4 ± 15.4 mm in the repeated freeze and thaw group, P = .99). CONCLUSION: Repeated freezing and thawing did not affect the suture pullout strength of the arytenoid and cricoid cartilages. CLINICAL SIGNIFICANCE: Laryngeal specimens that have been subjected to repeated freezing and thawing can be utilized in the experimental evaluation of LP procedures because there is no alteration of the suture pull-out strength of the relevant cartilages.


Assuntos
Congelamento , Laringoplastia , Suturas , Animais , Cartilagem Aritenoide/cirurgia , Cadáver , Cartilagem Cricoide/cirurgia , Cavalos/cirurgia , Laringoplastia/métodos , Laringoplastia/veterinária , Suturas/veterinária
5.
J Occup Environ Hyg ; 19(9): 538-557, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35853136

RESUMO

The international fire service community is actively engaged in a wide range of activities focused on development, testing, and implementation of effective approaches to reduce exposure to contaminants and the related cancer risk. However, these activities are often viewed independent of each other and in the absence of the larger overall effort of occupational health risk mitigation. This narrative review synthesizes the current research on fire service contamination control in the context of the National Institute for Occupational Safety and Health (NIOSH) Hierarchy of Controls, a framework that supports decision making around implementing feasible and effective control solutions in occupational settings. Using this approach, we identify evidence-based measures that have been investigated and that can be implemented to protect firefighters during an emergency response, in the fire apparatus and at the fire station, and identify several knowledge gaps that remain. While a great deal of research and development has been focused on improving personal protective equipment for the various risks faced by the fire service, these measures are considered less effective. Administrative and engineering controls that can be used during and after the firefight have also received increased research interest in recent years. However, less research and development have been focused on higher level control measures such as engineering, substitution, and elimination, which may be the most effective, but are challenging to implement. A comprehensive approach that considers each level of control and how it can be implemented, and that is mindful of the need to balance contamination risk reduction against the fire service mission to save lives and protect property, is likely to be the most effective.


Assuntos
Bombeiros , Neoplasias , Exposição Ocupacional , Saúde Ocupacional , Contaminação de Medicamentos , Humanos , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Equipamento de Proteção Individual
6.
Int J Hyg Environ Health ; 242: 113969, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35421664

RESUMO

INTRODUCTION: Firefighters are exposed to volatile organic compounds (VOCs) during structural fire responses and training fires, several of which (e.g., benzene, acrolein, styrene) are known or probable carcinogens. Exposure studies have found that firefighters can absorb chemicals like benzene even when self-contained breathing apparatus (SCBA) are worn, suggesting that dermal absorption contributes to potentially harmful exposures. However, few studies have characterized VOC metabolites in urine from firefighters. OBJECTIVES: We quantified VOC metabolites in firefighters' urine following live firefighting activity across two field studies. METHODS: In two separate controlled field studies, spot urine was collected before and 3 h after firefighters and firefighter students responded to simulated residential and training fires. Urine was also collected from instructors from the training fire study before the first and 3 h after the last training scenario for each day (instructors led three training scenarios per day). Samples were analyzed for metabolites of VOCs to which firefighters may be exposed. RESULTS: In the residential fire study, urinary metabolites of xylenes (2MHA), toluene (BzMA), and styrene (MADA) increased significantly (at 0.05 level) from pre- to post-fire. In the training fire study, MADA concentrations increased significantly from pre- to post-fire for both firefighter students and instructors. Urinary concentrations of benzene metabolites (MUCA and PhMA) increased significantly from pre- to post-fire for instructors, while metabolites of xylenes (3MHA+4MHA) and acrolein (3HPMA) increased significantly for firefighter students. The two highest MUCA concentrations measured post-shift from instructors exceeded the BEI of 500 µg/g creatinine. CONCLUSIONS: Some of the metabolites that were significantly elevated post-fire are known or probable human carcinogens (benzene, styrene, acrolein); thus, exposure to these compounds should be eliminated or reduced as much as possible through the hierarchy of controls. Given stringent use of SCBA, it appears that dermal exposure contributes in part to the levels measured here.


Assuntos
Poluentes Ocupacionais do Ar , Bombeiros , Incêndios , Exposição Ocupacional , Hidrocarbonetos Policíclicos Aromáticos , Compostos Orgânicos Voláteis , Acroleína , Poluentes Ocupacionais do Ar/análise , Benzeno/análise , Carcinógenos , Bombeiros/educação , Humanos , Exposição Ocupacional/análise , Hidrocarbonetos Policíclicos Aromáticos/urina , Estirenos , Compostos Orgânicos Voláteis/análise , Xilenos
7.
Int J Hyg Environ Health ; 240: 113900, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34902715

RESUMO

The fire service has become more aware of the potential for adverse health outcomes due to occupational exposure to hazardous combustion byproducts. Because of these concerns, personal protective equipment (PPE) manufacturers have developed new protection concepts like particulate-blocking hoods to reduce firefighters' exposures. Additionally, fire departments have implemented exposure reduction interventions like routine laundering of PPE after fire responses. This study utilized a fireground exposure simulator (FES) with 24 firefighters performing firefighting activities on three consecutive days wearing one of three PPE ensembles (stratified by hood design and treatment of PPE): 1) new knit hood, new turnout jacket and new turnout pants 2) new particulate-blocking hood, new turnout jacket and new turnout pants or 3) laundered particulate-blocking hood, laundered turnout jacket and laundered turnout pants. As firefighters performed the firefighting activities, personal air sampling on the outside and inside the turnout jacket was conducted to quantify exposures to volatile organic compounds (VOCs) and naphthalene. Pre- and immediately post-fire exhaled breath samples were collected to characterize the absorption of VOCs. Benzene, toluene, and naphthalene were found to diffuse through and/or around the turnout jacket, as inside jacket benzene concentrations were often near levels reported outside the turnout jacket (9.7-11.7% median benzene reduction from outside the jacket to inside the jacket). The PPE ensemble did not appear to affect the level of contamination found inside the jacket for the compounds evaluated here. Benzene concentrations in exhaled breath increased significantly from pre to post-fire for all three groups (p-values < 0.05). The difference of pre-to post-fire benzene exhaled breath concentrations were positively associated with inside jacket and outside jacket benzene concentrations, even though self-contained breathing apparatus (SCBA) were worn during each response. This suggests the firefighters can absorb these compounds via the dermal route.


Assuntos
Poluentes Ocupacionais do Ar , Bombeiros , Exposição Ocupacional , Hidrocarbonetos Policíclicos Aromáticos , Poluentes Ocupacionais do Ar/análise , Benzeno/análise , Humanos , Naftalenos , Exposição Ocupacional/análise , Equipamento de Proteção Individual , Hidrocarbonetos Policíclicos Aromáticos/análise , Tolueno
8.
Vet Surg ; 50(7): 1409-1417, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34309058

RESUMO

OBJECTIVE: To evaluate the airway mechanics of modified toggle LP constructs in an airflow chamber model and compare these to the airway mechanics of standard LP constructs. STUDY DESIGN: Ex-vivo experimental study. SAMPLE POPULATION: Fifty-one equine cadaveric larynges. METHODS: Bilateral LP constructs were performed using a modified toggle (n = 23) or a standard (n = 21) LP technique. Constructs were tested in an airflow model before and after cyclic loading which was designed to mimic postoperative swallowing. The cross-sectional area (CSA), peak translaryngeal airflow (L/s), and impedance (cmH2 0/L/s) were determined and compared between LP constructs before and after cycling. RESULTS: The mean CSA of the rima glottidis of the modified toggle LP constructs was 15.2 ± 2.6 cm2 before and 14.7 ± 2.6 cm2 after cyclic loading, and the mean CSA of the rima glottidis of the standard LP constructs was 16.4 ± 2.9 cm2 before and 15.7 ± 2.8 cm2 after cyclic loading. The modified toggle LP constructs had similar peak translaryngeal impedance before and after cyclic loading (p = .13); however, the standard LP constructs had higher peak translaryngeal impedance after cyclic loading (p = .02). CONCLUSION: The modified toggle and standard LP constructs had comparable airway mechanics in an ex-vivo model. CLINICAL SIGNIFICANCE: Further investigation is warranted to determine the extent to which the modified toggle LP technique restores normal airway function in horses with RLN.


Assuntos
Laringoplastia , Laringe , Animais , Glote , Cavalos , Laringoplastia/veterinária , Vácuo
9.
Int J Hyg Environ Health ; 236: 113782, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34119852

RESUMO

Firefighters may encounter items containing flame retardants (FRs), including organophosphate flame retardants (OPFRs) and polybrominated diphenyl ethers (PBDEs), during structure fires. This study utilized biological monitoring to characterize FR exposures in 36 firefighters assigned to interior, exterior, and overhaul job assignments, before and after responding to controlled residential fire scenarios. Firefighters provided four urine samples (pre-fire and 3-h, 6-h, and 12-h post-fire) and two serum samples (pre-fire and approximately 23-h post-fire). Urine samples were analyzed for OPFR metabolites, while serum samples were analyzed for PBDEs, brominated and chlorinated furans, and chlorinated dioxins. Urinary concentrations of diphenyl phosphate (DPhP), a metabolite of triphenyl phosphate (TPhP), bis(1,3-dichloro-2-propyl) phosphate (BDCPP), a metabolite of tris(1,3-dichloro-2-propyl) phosphate (TDCPP), and bis(2-chloroethyl) phosphate (BCEtP), a metabolite of tris(2-chloroethyl) phosphate (TCEP), increased from pre-fire to 3-hr and 6-hr post-fire collection, but only the DPhP increase was statistically significant at a 0.05 level. The 3-hr and 6-hr post-fire concentrations of DPhP and BDCPP, as well as the pre-fire concentration of BDCPP, were statistically significantly higher than general population levels. BDCPP pre-fire concentrations were statistically significantly higher in firefighters who previously participated in a scenario (within the past 12 days) than those who were responding to their first scenario as part of the study. Similarly, firefighters previously assigned to interior job assignments had higher pre-fire concentrations of BDCPP than those previously assigned to exterior job assignments. Pre-fire serum concentrations of 2,3,4,7,8-pentachlorodibenzofuran (23478-PeCDF), a known human carcinogen, were also statistically significantly above the general population levels. Of the PBDEs quantified, only decabromodiphenyl ether (BDE-209) pre- and post-fire serum concentrations were statistically significantly higher than the general population. These results suggest firefighters absorbed certain FRs while responding to fire scenarios.


Assuntos
Dioxinas , Bombeiros , Incêndios , Retardadores de Chama , Furanos , Éteres Difenil Halogenados/análise , Humanos , Organofosfatos
10.
Artigo em Inglês | MEDLINE | ID: mdl-35673618

RESUMO

The fire service research community around the world has focused substantial resources on reducing firefighter risk for sudden cardiac events and chemical exposures that may lead to cancer. Research presented here summarizes important lessons learned from a full-scale residential Fire Study that allowed quantification of the risks as well as the effectiveness of interventions to reduce those risks. To address fireground exposure concerns, personal protective equipment (PPE) and administrative controls exist. But, these controls are not always straightforward to apply. Leadership and management concerns with ongoing implementation of these controls are introduced and opportunities for change management are discussed. While research provides a solid basis upon which to institute policy and practice, fireground leadership and management is critical to ensure appropriate implementation.

11.
Int J Hyg Environ Health ; 222(7): 991-1000, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31272797

RESUMO

INTRODUCTION: Training fires may constitute a major portion of some firefighters' occupational exposures to smoke. However, the magnitude and composition of those exposures are not well understood and may vary by the type of training scenario and fuels. OBJECTIVES: To understand how structure fire training contributes to firefighters' and instructors' select chemical exposures, we conducted biological monitoring during exercises involving combustion of pallet and straw and oriented strand board (OSB) or the use of simulated smoke. METHODS: Urine was analyzed for metabolites of polycyclic aromatic hydrocarbons (PAHs) and breath was analyzed for volatile organic compounds (VOCs) including benzene. RESULTS: Median concentrations of nearly all PAH metabolites in urine increased from pre-to 3-hr post-training for each scenario and were highest for OSB, followed by pallet and straw, and then simulated smoke. For instructors who supervised three trainings per day, median concentrations increased at each collection. A single day of OSB exercises led to a 30-fold increase in 1-hydroxypyrene for instructors, culminating in a median end-of-shift concentration 3.5-fold greater than median levels measured from firefighters in a previous controlled-residential fire study. Breath concentrations of benzene increased 2 to 7-fold immediately after the training exercises (with the exception of simulated smoke training). Exposures were highest for the OSB scenario and instructors accumulated PAHs with repeated daily exercises. CONCLUSIONS: Dermal absorption likely contributed to the biological levels as the respiratory route was well protected. Training academies should consider exposure risks as well as instructional objectives when selecting training exercises.


Assuntos
Poluentes Ocupacionais do Ar/análise , Benzeno/análise , Bombeiros , Exposição Ocupacional/análise , Hidrocarbonetos Policíclicos Aromáticos/urina , Poluentes Ocupacionais do Ar/urina , Monitoramento Biológico , Testes Respiratórios , Expiração , Feminino , Bombeiros/educação , Incêndios , Humanos , Masculino , Ensino
12.
J Occup Environ Hyg ; 16(5): 355-366, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30932751

RESUMO

Biomarker measurements can provide unambiguous evidence of environmental exposures as well as the resultant biological responses. Firefighters have a high rate of occupational cancer incidence, which has been proposed to be linked in part to their increased environmental exposure to byproducts of combustion and contaminants produced during fire responses. In this article, the uptake and elimination of targeted volatile organic compounds were investigated by collecting the exhaled breath of firefighters on sorbent tubes before and after controlled structure burns and analyzing samples using automated thermal desorption-gas chromatography (ATD-GC/MS). Volatile organic compounds exposure was assessed by grouping the data according to firefighting job positions as well as visualizing the data at the level of the individual firefighter to determine which individuals had expected exposure responses. When data were assessed at the group level, benzene concentrations were found to be elevated post-exposure in both fire attack, victim search, and outside ventilation firefighting positions. However, the results of the data analysis at the individual level indicate that certain firefighters may be more susceptible to post-exposure volatile organic compounds increases than others, and this should be considered when assessing the effectiveness of firefighting protective gear. Although this work focuses on firefighting activity, the results can be translated to potential human health and ecological effects from building and forest fires.


Assuntos
Testes Respiratórios , Bombeiros , Incêndios , Exposição Ocupacional/análise , Adulto , Poluentes Ocupacionais do Ar/análise , Benzeno/análise , Biomarcadores/análise , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Orgânicos Voláteis/análise
13.
J Occup Environ Hyg ; 16(2): 129-140, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30427284

RESUMO

Firefighters are occupationally exposed to products of combustion containing polycyclic aromatic hydrocarbons (PAHs) and flame retardants (FRs), potentially contributing to their increased risk for certain cancers. Personal protective equipment (PPE), including firefighter hoods, helps to reduce firefighters' exposure to toxic substances during fire responses by providing a layer of material on which contaminants deposit prior to reaching the firefighters skin. However, over time hoods that retain some contamination may actually contribute to firefighters' systemic dose. We investigated the effectiveness of laundering to reduce or remove contamination on the hoods, specifically PAHs and three classes of FRs: polybrominated diphenyl ethers (PBDEs), non-PBDE flame retardants (NPBFRs), and organophosphate flame retardants (OPFRs). Participants in the study were grouped into crews of 12 firefighters who worked in pairs by job assignment while responding to controlled fires in a single-family residential structure. For each pair of firefighters, one hood was laundered after every scenario and one was not. Bulk samples of the routinely laundered and unlaundered hoods from five pairs of firefighters were collected and analyzed. Residual levels of OPFRs, NPBFRs, and PAHs were lower in the routinely laundered hoods, with total levels of each class of chemicals being 56-81% lower, on average, than the unlaundered hoods. PBDEs, on average, were 43% higher in the laundered hoods, most likely from cross contamination. After this initial testing, four of the five unlaundered exposed hoods were subsequently laundered with other heavily exposed (unlaundered) and unexposed (new) hoods. Post-laundering evaluation of these hoods revealed increased levels of PBDEs, NPBFRs, and OPFRs in both previously exposed and unexposed hoods, indicating cross contamination. For PAHs, there was little evidence of cross contamination and the exposed hoods were significantly less contaminated after laundering (76% reduction; p = 0.011). Further research is needed to understand how residual contamination on hoods could contribute to firefighters' systemic exposures.


Assuntos
Bombeiros , Retardadores de Chama/análise , Lavanderia , Hidrocarbonetos Policíclicos Aromáticos/análise , Roupa de Proteção , Incêndios , Éteres Difenil Halogenados/análise , Humanos , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle
14.
PLoS One ; 13(8): e0201830, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30130361

RESUMO

Firefighting activities appear to increase the risk of acute and chronic lung disease, including malignancy. While self-contained breathing apparatuses (SCBA) mitigate exposures to inhalable asphyxiates and carcinogens, firefighters frequently remove SCBA during overhaul when the firegrounds appear clear of visible smoke. Using a mouse model of overhaul without airway protection, the impact of fireground environment exposure on lung gene expression was assessed to identify transcripts potentially critical to firefighter-related chronic pulmonary illnesses. Lung tissue was collected 2 hrs post-overhaul and evaluated via whole genome transcriptomics by RNA-seq. Although gas metering showed that the fireground overhaul levels of carbon monoxide (CO), carbon dioxide (CO2), hydrogen cyanine (HCN), hydrogen sulfide (H2S) and oxygen (O2) were within NIOSH ceiling recommendations, 3852 lung genes were differentially expressed when mice exposed to overhaul were compared to mice on the fireground but outside the overhaul environment. Importantly, overhaul exposure was associated with an up/down-regulation of 86 genes with a fold change of 1.5 or greater (p<0.5) including the immunomodulatory-linked genes S100a8 and Tnfsf9 (downregulation) and the cancer-linked genes, Capn11 and Rorc (upregulation). Taken together these findings indicate that, without respiratory protection, exposure to the fireground overhaul environment is associated with transcriptional changes impacting proteins potentially related to inflammation-associated lung disease and cancer.


Assuntos
Poluentes Ocupacionais do Ar/efeitos adversos , Bombeiros , Doenças do Sistema Imunitário/metabolismo , Exposição por Inalação/efeitos adversos , Pneumopatias/metabolismo , Pulmão/metabolismo , Animais , Estudos de Coortes , Incêndios , Regulação da Expressão Gênica , Doenças do Sistema Imunitário/epidemiologia , Pneumopatias/epidemiologia , Masculino , Camundongos Endogâmicos C57BL , Modelos Animais , Exposição Ocupacional , Dispositivos de Proteção Respiratória , Fatores de Risco , Transcriptoma
15.
Ann Occup Hyg ; 58(7): 830-45, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24906357

RESUMO

Turnout gear provides protection against dermal exposure to contaminants during firefighting; however, the level of protection is unknown. We explored the dermal contribution to the systemic dose of polycyclic aromatic hydrocarbons (PAHs) and other aromatic hydrocarbons in firefighters during suppression and overhaul of controlled structure burns. The study was organized into two rounds, three controlled burns per round, and five firefighters per burn. The firefighters wore new or laundered turnout gear tested before each burn to ensure lack of PAH contamination. To ensure that any increase in systemic PAH levels after the burn was the result of dermal rather than inhalation exposure, the firefighters did not remove their self-contained breathing apparatus until overhaul was completed and they were >30 m upwind from the burn structure. Specimens were collected before and at intervals after the burn for biomarker analysis. Urine was analyzed for phenanthrene equivalents using enzyme-linked immunosorbent assay and a benzene metabolite (s-phenylmercapturic acid) using liquid chromatography/tandem mass spectrometry; both were adjusted by creatinine. Exhaled breath collected on thermal desorption tubes was analyzed for PAHs and other aromatic hydrocarbons using gas chromatography/mass spectrometry. We collected personal air samples during the burn and skin wipe samples (corn oil medium) on several body sites before and after the burn. The air and wipe samples were analyzed for PAHs using a liquid chromatography with photodiode array detection. We explored possible changes in external exposures or biomarkers over time and the relationships between these variables using non-parametric sign tests and Spearman tests, respectively. We found significantly elevated (P < 0.05) post-exposure breath concentrations of benzene compared with pre-exposure concentrations for both rounds. We also found significantly elevated post-exposure levels of PAHs on the neck compared with pre-exposure levels for round 1. We found statistically significant positive correlations between external exposures (i.e. personal air concentrations of PAHs) and biomarkers (i.e. change in urinary PAH metabolite levels in round 1 and change in breath concentrations of benzene in round 2). The results suggest that firefighters wearing full protective ensembles absorbed combustion products into their bodies. The PAHs most likely entered firefighters' bodies through their skin, with the neck being the primary site of exposure and absorption due to the lower level of dermal protection afforded by hoods. Aromatic hydrocarbons could have been absorbed dermally during firefighting or inhaled during the doffing of gear that was off-gassing contaminants.


Assuntos
Benzeno/análise , Bombeiros , Incêndios , Exposição Ocupacional/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Poluentes Ocupacionais do Ar/análise , Benzeno/toxicidade , Biomarcadores/urina , Monitoramento Ambiental/métodos , Humanos , Exposição por Inalação/análise , Exposição Ocupacional/efeitos adversos , Hidrocarbonetos Policíclicos Aromáticos/toxicidade , Roupa de Proteção , Absorção Cutânea