Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
ACS Appl Mater Interfaces ; 15(25): 29914-29926, 2023 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-37314985

RESUMO

An approach to assess severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection (and past infection) was developed. For virus detection, the SARS-CoV-2 virus nucleocapsid protein (NP) was targeted. To detect the NP, antibodies were immobilized on magnetic beads to capture the NPs, which were subsequently detected using rabbit anti-SARS-CoV-2 nucleocapsid antibodies and alkaline phosphatase (AP)-conjugated anti-rabbit antibodies. A similar approach was used to assess SARS-CoV-2-neutralizing antibody levels by capturing spike receptor-binding domain (RBD)-specific antibodies utilizing RBD protein-modified magnetic beads and detecting them using AP-conjugated anti-human IgG antibodies. The sensing mechanism for both assays is based on cysteamine etching-induced fluorescence quenching of bovine serum albumin-protected gold nanoclusters where cysteamine is generated in proportion to the amount of either SARS-CoV-2 virus or anti-SARS-CoV-2 receptor-binding domain-specific immunoglobulin antibodies (anti-RBD IgG antibodies). High sensitivity can be achieved in 5 h 15 min for the anti-RBD IgG antibody detection and 6 h 15 min for virus detection, although the assay can be run in "rapid" mode, which takes 1 h 45 min for the anti-RBD IgG antibody detection and 3 h 15 min for the virus. By spiking the anti-RBD IgG antibodies and virus in serum and saliva, we demonstrate that the assay can detect the anti-RBD IgG antibodies with a limit of detection (LOD) of 4.0 and 2.0 ng/mL in serum and saliva, respectively. For the virus, we can achieve an LOD of 8.5 × 105 RNA copies/mL and 8.8 × 105 RNA copies/mL in serum and saliva, respectively. Interestingly, this assay can be easily modified to detect myriad analytes of interest.


Assuntos
COVID-19 , SARS-CoV-2 , Animais , Coelhos , COVID-19/diagnóstico , Soroalbumina Bovina , Cisteamina , Anticorpos Antivirais , Imunoglobulina G
2.
ESMO Open ; 5(2)2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32220948

RESUMO

OBJECTIVE: There are no validated approaches to predict benefit from adjuvant chemotherapy for resected patients with non-small-cell lung cancer (NSCLC). The aim of this study was to translate a 15-gene mRNA expression profile published by Zhu et al, shown to be prognostic and predictive of benefit, into a readily applicable immunohistochemistry (IHC) panel. METHODS: For seven of the genes in the gene expression profile (GEP) for which suitable commercial antibodies were available, we semiquantitatively assessed the IHC expression and prognostic significance for 173 patients treated at the Saint John Regional Hospital (SJRH). Cut-offs for high and low expression were defined for each marker and applied to IHC scores from 291 of the 482 patients in JBR.10, including patients on both the adjuvant chemotherapy and observation arms. The prognostic and predictive value of these markers on overall survival (OS) or recurrence-free survival (RFS) was assessed by Cox regression models. RESULTS: In the SJRH cohort, in 62 patients with resected stage II-III NSCLC, the prognostic significance of IHC assays for four proteins were concordant with Zhu's GEP results. Low FOSL2 (OS, HR=0.15; p=0.0001; RFS, HR=0.14; p<0.0001) and high STMN2 (RFS, HR=2.501; p=0.0197) were adverse prognostic factors. Low ATP1B1 and low TRIM14 expression trended toward worse OS and RFS. Validation of these markers with JBR.10 patients failed to show prognostic significance either individually or in combined risk classifications. Additionally, the interaction between these markers and chemotherapy treatment in predicting OS (FOSL2, p=0.52; STMN2 p=0.14; ATP1B1, p=0.33; TRIM14, p=0.81) or RFS (FOSL2, p=0.63; STMN2, p=0.12; ATP1B1, p=0.66; TRIM14, p=0.57) did not reach significance, individually or in combination panels. CONCLUSIONS: Zhu's GEP could not be translated into an IHC panel predictive of benefit from adjuvant chemotherapy. Future predictive biomarker analysis in the adjuvant NSCLC setting may need to focus on novel therapies.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Quimioterapia Adjuvante/métodos , Imuno-Histoquímica/métodos , Neoplasias Pulmonares/tratamento farmacológico , Transcriptoma/genética , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico
3.
Anal Sci ; 36(7): 813-819, 2020 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-31932523

RESUMO

A very simple and non-extractive spectrofluorometric method for the swift determination of aluminum at nano-trace levels using 2',3,4',5,7-pentahydroxyflavone (morin) has been developed. Morin reacts in a slightly acidic (0.005 - 0.025 M H2SO4) solution with aluminum in 20% ethanol to produce a highly fluorescent complex in aqueous solution, which has excitation and emission wavelengths of λex = 270 and λem = 565 nm, respectively. Linear calibration graphs were obtained for 0.01 - 800 µg L-1 of Al, providing a detection limit of 1 ng L-1. The limit of quantification of the reaction system was 10 ng L-1. The stoichiometric composition of chelate is 3:2 (Al:morin). The developed method was successfully used in the determination of aluminum in several Standard Reference Materials (SRM) as well as in some water, biological, hemodialysis solutions, food, pharmaceutical, soil sample, and complex synthetic mixtures. The results of the proposed method for biological and food analysis were found to be in excellent agreement with those obtained by AAS. The results of the proposed method for hemodialysis solutions were analogous with those obtained using the method described in British Pharmacopoeia within 95% confidence limits.


Assuntos
Alumínio/análise , Poluentes Ambientais/análise , Flavonoides/química , Contaminação de Alimentos/análise , Nanopartículas/análise , Poluentes Químicos da Água/análise , Contaminação de Medicamentos , Diálise Renal , Espectrometria de Fluorescência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA