Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
JACC Cardiovasc Imaging ; 17(8): 847-860, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38795109

RESUMO

BACKGROUND: In patients with low-gradient aortic stenosis (AS) and low transvalvular flow, dobutamine stress echocardiography (DSE) is recommended to determine AS severity, whereas the degree of aortic valve calcification (AVC) supposedly correlates with AS severity according to current European and American guidelines. OBJECTIVES: The purpose of this study was to assess the relationship between AVC and AS severity as determined using echocardiography and DSE in patients with aortic valve area <1 cm2 and peak aortic valve velocity <4.0 m/s. METHODS: All patients underwent DSE to determine AS severity and multislice computed tomography to quantify AVC. Receiver-operating characteristics curve analysis was used to assess the diagnostic value of AVC for AS severity grading as determined using echocardiography and DSE in men and women. RESULTS: A total of 214 patients were included. Median age was 78 years (25th-75th percentile: 71-84 years) and 25% were women. Left ventricular ejection fraction was reduced (<50%) in 197 (92.1%) patients. Severe AS was diagnosed in 106 patients (49.5%). Moderate AS was diagnosed in 108 patients (50.5%; in 77 based on resting transthoracic echocardiography, in 31 confirmed using DSE). AVC score was high (≥2,000 for men or ≥1,200 for women) in 47 (44.3%) patients with severe AS and in 47 (43.5%) patients with moderate AS. AVC sensitivity was 44.3%, specificity was 56.5%, and positive and negative predictive values for severe AS were 50.0% and 50.8%, respectively. Area under the receiver-operating characteristics curve was 0.508 for men and 0.524 for women. CONCLUSIONS: Multi-slice computed tomography-derived AVC scores showed poor discrimination between grades of AS severity using DSE and cannot replace DSE in the diagnostic work-up of low-gradient severe AS.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Calcinose , Ecocardiografia sob Estresse , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Masculino , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/patologia , Calcinose/diagnóstico por imagem , Calcinose/fisiopatologia , Idoso de 80 Anos ou mais , Reprodutibilidade dos Testes , Curva ROC , Função Ventricular Esquerda , Área Sob a Curva , Volume Sistólico , Hemodinâmica
2.
Int J Cardiovasc Imaging ; 40(1): 15-25, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37815685

RESUMO

Bedside quantification of stroke volume (SV) and left ventricular ejection fraction (LVEF) is valuable in hemodynamically compromised patients. Miniaturized handheld ultrasound (HAND) devices are now available for clinical use. However, the performance level of HAND devices for quantified cardiac assessment is yet unknown. The aim of this study was to compare the validity of HAND measurements with standard echocardiography (SE) and three-dimensional echocardiography (3DE). Thirty-six patients were scanned with HAND, SE and 3DE. LVEF and SV quantification was done with automated software for the HAND, SE and 3DE dataset. The image quality of HAND and SE was evaluated by scoring segmental endocardial border delineation (2 = good, 1 = poor, 0 = invisible). LVEF and SV of HAND was evaluated against SE and 3DE using correlation and Bland-Altman analysis. The correlation, bias, and limits of agreement (LOA) between HAND and SE were 0.68 [0.46:0.83], 1.60% [- 2.18:5.38], and 8.84% [- 9.79:12.99] for LVEF, and 0.91 [0.84:0.96], 1.32 ml [- 0.36:4.01], 15.54 ml [- 18.70:21.35] for SV, respectively. Correlation, bias, and LOA between HAND and 3DE were 0.55 [0.6:0.74], - 0.56% [- 2.27:1.1], and 9.88% [- 13.29:12.17] for LVEF, and 0.79 [0.62:0.89], 6.78 ml [2.34:11.21], 12.14 ml [- 26.32:39.87] for SV, respectively. The image quality scores were 9.42 ± 2.0 for the apical four chamber views of the HAND dataset and 10.49 ± 1.7 for the SE dataset and (P < 0.001). Clinically acceptable accuracy, precision, and image quality was demonstrated for HAND measurements compared to SE. In comparison to 3DE, HAND showed a clinically acceptable accuracy and precision for LVEF quantification.


Assuntos
Ecocardiografia Tridimensional , Função Ventricular Esquerda , Humanos , Volume Sistólico , Ventrículos do Coração/diagnóstico por imagem , Valor Preditivo dos Testes , Ecocardiografia , Ecocardiografia Tridimensional/métodos , Reprodutibilidade dos Testes
3.
JAMA Netw Open ; 6(7): e2323112, 2023 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-37436747

RESUMO

Importance: It is suggested that patients with Cutibacterium acnes endocarditis often present without fever or abnormal inflammatory markers. However, no study has yet confirmed this statement. Objective: To assess the clinical characteristics and outcomes of patients with C acnes endocarditis. Design, Setting, and Participants: A case series of 105 patients presenting to 7 hospitals in the Netherlands and France (4 university hospitals and 3 teaching hospitals) with definite endocarditis according to the modified Duke criteria between January 1, 2010, and December 31, 2020, was performed. Clinical characteristics and outcomes were retrieved from medical records. Cases were identified by blood or valve and prosthesis cultures positive for C acnes, retrieved from the medical microbiology databases. Infected pacemaker or internal cardioverter defibrillator lead cases were excluded. Statistical analysis was performed in November 2022. Main Outcomes and Measures: Main outcomes included symptoms at presentation, presence of prosthetic valve endocarditis, laboratory test results at presentation, time to positive results of blood cultures, 30-day and 1-year mortality rates, type of treatment (conservative or surgical), and endocarditis relapse rates. Results: A total of 105 patients (mean [SD] age, 61.1 [13.9] years; 96 men [91.4%]; 93 patients [88.6%] with prosthetic valve endocarditis) were identified and included. Seventy patients (66.7%) did not experience fever prior to hospital admission, nor was it present at hospitalization. The median C-reactive protein level was 3.6 mg/dL (IQR, 1.2-7.5 mg/dL), and the median leukocyte count was 10.0 × 103/µL (IQR, 8.2-12.2 × 103/µL). The median time to positive blood culture results was 7 days (IQR, 6-9 days). Surgery or reoperation was indicated for 88 patients and performed for 80 patients. Not performing the indicated surgical procedure was associated with high mortality rates. Seventeen patients were treated conservatively, in accordance with the European Society of Cardiology guideline; these patients showed relatively high rates of endocarditis recurrence (5 of 17 [29.4%]). Conclusions and Relevance: This case series suggests that C acnes endocarditis was seen predominantly among male patients with prosthetic heart valves. Diagnosing C acnes endocarditis is difficult due to its atypical presentation, with frequent absence of fever and inflammatory markers. The prolonged time to positivity of blood culture results further delays the diagnostic process. Not performing a surgical procedure when indicated seems to be associated with higher mortality rates. For prosthetic valve endocarditis with small vegetations, there should be a low threshold for surgery because this group seems prone to endocarditis recurrence.


Assuntos
Doenças Transmissíveis , Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/terapia , Próteses Valvulares Cardíacas/efeitos adversos , Endocardite/complicações , Eletrocardiografia
4.
Ann Lab Med ; 43(3): 253-262, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36544337

RESUMO

Background: Heart failure (HF) biomarkers have prognostic value. The aim of this study was to combine HF biomarkers into an objective classification system for risk stratification of patients with HF. Methods: HF biomarkers were analyzed in a population of HF outpatients and expressed relative to their cut-off values (N-terminal pro-B-type natriuretic peptide [NT-proBNP] >1,000 pg/mL, soluble suppression of tumorigenesis-2 [ST2] >35 ng/mL, growth differentiation factor-15 [GDF-15] >2,000 pg/mL, and fibroblast growth factor-23 [FGF-23] >95.4 pg/mL). Biomarkers that remained significant in multivariable analysis were combined to devise the Heartmarker score. The performance of the Heartmarker score was compared to the widely used New York Heart Association (NYHA) classification based on symptoms during ordinary activity. Results: HF biomarkers of 245 patients were analyzed, 45 (18%) of whom experienced the composite endpoint of HF hospitalization, appropriate implantable cardioverter-defibrillator shock, or death. HF biomarkers were elevated more often in patients that reached the composite endpoint than in patients that did not reach the endpoint. NT-proBNP, ST2, and GDF-15 were independent predictors of the composite endpoint and were thus combined as the Heartmarker score. The event-free survival and distance covered in 6 minutes of walking decreased with an increasing Heartmarker score. Compared with the NYHA classification, the Heartmarker score was better at discriminating between different risk classes and had a comparable relationship to functional capacity. Conclusions: The Heartmarker score is a reproducible and intuitive model for risk stratification of outpatients with HF, using routine biomarker measurements.


Assuntos
Insuficiência Cardíaca , Humanos , Biomarcadores , Fator 15 de Diferenciação de Crescimento/sangue , Fator 15 de Diferenciação de Crescimento/química , Insuficiência Cardíaca/diagnóstico , Proteína 1 Semelhante a Receptor de Interleucina-1 , Peptídeo Natriurético Encefálico/sangue , Peptídeo Natriurético Encefálico/química , Fragmentos de Peptídeos , Prognóstico , Fator de Crescimento de Fibroblastos 23/sangue , Fator de Crescimento de Fibroblastos 23/química
5.
J Am Soc Echocardiogr ; 35(1): 105-115.e8, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34389469

RESUMO

BACKGROUND: Functional mitral regurgitation (FMR) can be subclassified on the basis of its proportionality relative to left ventricular (LV) volume and function, indicating potential differences in underlying etiology. The aim of this study was to evaluate the association of FMR proportionality with FMR reduction, heart failure hospitalization and mortality after transcatheter edge-to-edge mitral valve repair (TEER). METHODS: This multicenter registry included 241 patients with symptomatic heart failure with reduced LV ejection fraction treated with TEER for moderate to severe or greater FMR. FMR proportionality was graded on preprocedural transthoracic echocardiography using the ratio of the effective regurgitant orifice area to LV end-diastolic volume. Baseline characteristics, follow-up transthoracic echocardiography, and 2-year clinical outcomes were compared between groups. RESULTS: Median LV ejection fraction, effective regurgitant orifice area and LV end-diastolic volume index were 30% (interquartile range [IQR], 25%-35%), 27 mm2, and 107 mL/m2 (IQR, 90-135 mL/m2), respectively. Median effective regurgitant orifice area/LV end-diastolic volume ratio was 0.13 (IQR, 0.10-0.18). Proportionate FMR (pFMR) and disproportionate FMR (dFMR) was present in 123 and 118 patients, respectively. Compared with patients with pFMR, those with dFMR had higher baseline LV ejection fractions (median, 32% [IQR, 27%-39%] vs 26% [IQR, 22%-33%]; P < .01). Early FMR reduction with TEER was more pronounced in patients with dFMR (odds ratio, 0.45; 95% CI, 0.28-0.74; P < .01) than those with pFMR, but not at 12 months (odds ratio, 0.93; 95% CI, 0.53-1.63; P = .80). Overall, in 35% of patients with initial FMR reduction after TEER, FMR deteriorated again at 1-year follow-up. Rates of 2-year all-cause mortality and heart failure hospitalization were 30% (n = 66) and 37% (n = 76), with no differences between dFMR and pFMR. CONCLUSIONS: TEER resulted in more pronounced early FMR reduction in patients with dFMR compared with those with pFMR. Yet after initial improvement, FMR deteriorated in a substantial number of patients, calling into question durable mitral regurgitation reductions with TEER in selected patients. The proportionality framework may not identify durable TEER responders.


Assuntos
Insuficiência da Valva Mitral , Ecocardiografia , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
6.
Ann Card Anaesth ; 24(4): 500-502, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34747766

RESUMO

A 69-year-old patient underwent an urgent aortic valve replacement because of Streptococcus agalactiae endocarditis of his native aortic valve. Since a rapid progression of the former abscess cavity into an aortic root pseudoaneurysm with increasing paravalvular regurgitation during postoperative follow-up, reoperation was performed. In the preoperative transesophageal echocardiography (TEE) images the pseudoaneurysm completely surrounds the left coronary artery (LCA) without any signs of myocardial ischemia.


Assuntos
Falso Aneurisma , Endocardite Bacteriana , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Idoso , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Reoperação
7.
Open Heart ; 7(1): e001138, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32518657

RESUMO

Background: Loss of high-molecular-weight multimers (HMWMs) of von Willebrand factor (vWF) occurs due to high shear stress in patients with aortic stenosis. As symptoms of aortic stenosis occur during exercise, measurement of vWF during exercise might identify patients with aortic stenosis of clinical importance. The aim of this pilot study is to evaluate whether vWF changes over time as a result of exercise in patients with asymptomatic moderate or severe aortic stenosis. Methods: Ten subjects were analysed for changes in vWF by measuring HMWMs and closure time with adenosine diphosphate (CT-ADP). All subjects underwent a full stress test on a bicycle ergometer. At rest and at peak exercise, a transthoracic echocardiogram was performed. HMWMs and CT-ADP were assessed at baseline, during and after exercise. Results: HMWMs and CT-ADP did not change significantly during exercise, p=0.45 and p=0.65, respectively. HMWMs and CT-ADP correlated well, Spearman's rho -0.621, p<0.001. HMWMs during peak exercise did not correlate with maximal velocity measured, p=0.21. CT-ADP during exercise correlated well with the maximal echocardiographic velocity over the aortic valve (AV), rho 0.82, p=0.04. Conclusions: In a cohort of 10 patients with moderate or severe aortic stenosis, we observed no significant change in vWF biomarkers during exercise. Peak CT-ADP during exercise showed a good correlation with peak AV velocity measured with echo. Although CT-ADP is an easy test to perform and could be an alternative for peak AV velocity measured during exercise, our results suggest that it can only detect large changes in shear stress.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Teste de Esforço , Fator de von Willebrand/análise , Difosfato de Adenosina/sangue , Idoso , Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/fisiopatologia , Ciclismo , Biomarcadores/sangue , Ecocardiografia sob Estresse , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Fatores de Tempo
8.
J Card Surg ; 35(3): 672-674, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31945220

RESUMO

Mitral valve (MV) surgery is the second most performed valve operation in Europe. MV pathology is associated with atrial fibrillation, and, therefore, frequently combined with rhythm surgery and left atrial appendage exclusion (LAAE). Currently, no guidelines exist regarding the follow up after LAAE postoperative. Postoperative imaging with computed tomography (CT), in the absence of complaints, will inherently reveal unsuspected cardiac and noncardiac findings with potential clinical significance. However, poststernotomy alterations are nonspecific and often overlap with normal postoperative changes and could, therefore, not directly be recognized. Virtual three-dimensional (3D) CT reconstructions can help us to visualize 2D structures, especially in areas where structures overlap like coronary arteries or when devices (atrial clip, MV prosthesis) cause scattering artifacts. Advanced imaging reconstructions and 3D printing can enhance understanding of the cardiac anatomy in the postoperative phase and help us to determine follow-up strategies.


Assuntos
Implante de Prótese de Valva Cardíaca , Processamento de Imagem Assistida por Computador/métodos , Valva Mitral/diagnóstico por imagem , Valva Mitral/patologia , Impressão Tridimensional , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Período Pós-Operatório
9.
Eur Heart J Case Rep ; 4(6): 1-5, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33623859

RESUMO

BACKGROUND: COVID-19 is a novel disease that has been associated with changes in haemostasis and increased risk of thrombosis, especially in patients who are critically ill. CASE SUMMARY: a 71-year-old patient presented to the emergency department with acute respiratory failure. The patient had been discharged from the hospital 1 day before, after apparent recovery of a proven COVID-19 infection. Relevant medical history reports polycythemia vera. The diagnostic work-up included a CT-scan of the thorax, revealing bilateral sub-segmental pulmonary embolism. An echocardiogram showed a dilated right ventricle with poor systolic function and a large multi-lobar thrombus. Forty-eight hours after initiation of treatment with therapeutic anticoagulation the thrombus was no longer seen on the echocardiogram. DISCUSSION: This case confirms the high risk of thrombosis in COVID-19 infection as has been described in recent literature. It demonstrates the severity of the coagulopathy given the presence of both bilateral sub-segmental pulmonary embolism and right ventricular thrombus, despite treatment with prophylactic anticoagulation. Remarkable in this case is the fact that the patient had a myeloproliferative neoplasm (polycythaemia vera). This is associated with an increased risk of thrombosis, especially in the presence of erythrocytosis, leucocytosis, and/or inflammation.

10.
Interact Cardiovasc Thorac Surg ; 21(2): 183-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25972592

RESUMO

OBJECTIVES: Literature reporting on large patient groups with the long-term follow-up is limited due to the low incidence of myxomas. This single-centre, retrospective study reports on the long-term follow-up (e.g. complications, recurrence and survival) of a substantial patient group operated for cardiac myxomas. METHODS: Patients were retrospectively selected from a prospectively obtained database comprising patients who had undergone cardiac surgery in the Catharina Hospital from 1990 onwards. Baseline characteristics and perioperative data were obtained from the database. In case of insufficient information, medical reports were analysed. The echocardiogram and clinical follow-up data were collected at outpatient clinics. RESULTS: Eighty-two patients were included, of which 48 were females with a mean age of 61.3 years (±13.8). The main presenting symptom was dyspnoea (29.3%), followed by chest pain (24.4%), palpitations (19.5%) and embolism (15.9%). Atrial fibrillation was the most frequent complication; directly postoperative (22%) and at the long-term follow-up (26.3%). The follow-up was completed in 95.1%, with a mean echocardiographic follow-up time of 72 months and with a longest follow-up of almost 23 years. There were no myxoma recurrences. Thirteen patients (16.5%) deceased during the follow-up, with a mean time of 9 years after surgery. CONCLUSIONS: Myxomas carry the risk of severe complications. Surgical excision is the only option of treatment and gives excellent early and long-term results. Recurrence rates are low in case of non-hereditary myxomas, even in case of irradical excision. The echocardiographic follow-up therefore could be called into question.


Assuntos
Átrios do Coração/cirurgia , Neoplasias Cardíacas/cirurgia , Mixoma/cirurgia , Idoso , Fibrilação Atrial/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Estudos Retrospectivos , Resultado do Tratamento
11.
Eur J Cardiothorac Surg ; 47(2): e47-53, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25473031

RESUMO

OBJECTIVES: Recently, transcatheter aortic valve implantation has been introduced, but one of its complications is left bundle branch block (LBBB), a conduction disturbance that has been associated with increased mortality. We investigated the incidence and fate of both right bundle branch block (RBBB) and LBBB after aortic valve replacement (AVR) using a retrospective analysis. We also studied the predictive value of both disorders for all-cause mortality. METHODS: All patients who underwent AVR, with or without concomitant coronary artery bypass grafting surgery, between 2002 and 2010 in our centre were included. All-cause mortality was compared between patients who did and those who did not develop persistent new bundle branch block (BBB) within 7 days postoperatively. Patients were not eligible if one of their electrocardiogram (ECG) recordings prior to AVR showed a BBB or pacemaker activity. A postoperative period of 3-12 months was used to collect follow-up ECGs. RESULTS: Of the 2279 AVR patients, 2033 patients were eligible for analysis. After excluding patients lacking baseline or follow-up ECG (n = 269), 1764 patients remained for analysis. Early LBBB and RBBB occurred in 71 (4.0%) and 92 (5.2%) patients, respectively. At follow-up, LBBB was persistent in 29 patients (1.6%) and RBBB in 74 patients (4.2%). During a median follow-up of 4.5 (2.4-6.5) years, the mortality rate was 16.3% (n = 271) in patients without BBB, 24.1% (n = 7) in patients with persistent LBBB and 18.9% (n = 14) in patients with persistent RBBB (log-rank P = 0.49). Though, in univariate analysis, the hazard ratio for mortality was 1.54 and 1.10 for LBBB and RBBB, respectively, the small numbers precluded identifying AVR-induced LBBB and RBBB as a predictor of mortality. CONCLUSIONS: In the current practice of AVR, persistent postoperative LBBB and RBBB occur infrequently (∼ 5% of cases), a percentage less than half of that in current transcatheter aortic valve implantation procedures. Given the adverse effects of LBBB, the lower prevalence of procedure-induced LBBB in AVR should be taken into account while deciding which valve replacement procedure is chosen for a patient.


Assuntos
Valva Aórtica/cirurgia , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/mortalidade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Idoso , Arritmias Cardíacas , Bloqueio de Ramo/epidemiologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Fatores de Risco
12.
Cardiovasc Ultrasound ; 11: 36, 2013 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-24134671

RESUMO

BACKGROUND: Contrast-enhanced ultrasound (CEUS) has recently been proposed as a minimally- invasive, alternative method for blood volume measurement. This study aims at comparing the accuracy of CEUS and the classical thermodilution techniques for volume assessment in an in-vitro set-up. METHODS: The in-vitro set-up consisted of a variable network between an inflow and outflow tube and a roller pump. The inflow and outflow tubes were insonified with an ultrasound array transducer and a thermistor was placed in each tube. Indicator dilution curves were made by injecting indicator which consisted of an ultrasound-contrast-agent diluted in ice-cold saline. Both acoustic intensity- and thermo-dilution curves were used to calculate the indicator mean transit time between the inflow and outflow tube. The volumes were derived by multiplying the estimated mean transit time by the flow rate. We compared the volumes measured by CEUS with the true volumes of the variable network and those measured by thermodilution by Bland-Altman and intraclass-correlation analysis. RESULTS: The measurements by CEUS and thermodilution showed a very strong correlation (rs = 0.94) with a modest volume underestimation by CEUS of -40 ± 28 mL and an overestimation of 84 ± 62 mL by thermodilution compared with the true volumes. Both CEUS and thermodilution showed a high statistically significant correlation with the true volume (rs = 0.97 (95% CI, 0.95 - 0.98; P<0.0001) and rs = 0.96 (95% CI, 0.94 - 0.98; P<0.0001, respectively). CONCLUSIONS: CEUS volume estimation provides a strong correlation with both the true volumes in-vitro and volume estimation by thermodilution. It may therefore represent an interesting alternative to the standard, invasive thermodilution technique.


Assuntos
Determinação do Volume Sanguíneo/métodos , Ecocardiografia Transesofagiana/instrumentação , Ecocardiografia Transesofagiana/métodos , Imagens de Fantasmas , Fosfolipídeos , Hexafluoreto de Enxofre , Volume Sanguíneo/fisiologia , Meios de Contraste/administração & dosagem , Desenho de Equipamento , Humanos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Fosfolipídeos/administração & dosagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Hexafluoreto de Enxofre/administração & dosagem , Termodiluição
13.
Pediatr Res ; 73(4 Pt 1): 427-34, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23329199

RESUMO

BACKGROUND: Cardiac dysfunction is reported to occur after severe perinatal asphyxia. We hypothesized that anesthesia of the mother with propofol during emergency cesarean section (c-section) would result in less cardiac injury (troponin T) in preterm fetuses exposed to global severe asphyxia in utero than anesthesia with isoflurane. We tested whether propofol decreases the activity of proapoptotic caspase-3 by activating the antiapoptotic AKT kinase family and the signal transducer and activator of transcription-3 (STAT-3). METHODS: Pregnant ewes were randomized to receive either propofol or isoflurane anesthesia. A total of 44 late-preterm lambs were subjected to in utero umbilical cord occlusion (UCO), resulting in asphyxia and cardiac arrest, or sham treatment. After emergency c-section, each fetus was resuscitated, mechanically ventilated, and supported under anesthesia for 8 h using the same anesthetic as the one received by its mother. RESULTS: At 8 h after UCO, the fetuses whose mothers had received propofol anesthesia had lower plasma troponin T levels, and showed a trend toward a higher median left ventricular ejection fraction (LVEF) of 84% as compared with 74% for those whose mothers had received isoflurane. Postasphyxia activation of caspase-3 was lower in association with propofol anesthesia than with isoflurane. Postasphyxia levels of STAT-3 and the AKT kinase family rose 655% and 500%, respectively with the use of propofol anesthesia for the mother. CONCLUSION: The use of propofol for maternal anesthesia results in less cardiac injury in late-preterm lambs subjected to asphyxia than the use of isoflurane anesthesia. The underlying mechanism may be activation of the antiapoptotic STAT-3 and AKT pathways.


Assuntos
Anestésicos Intravenosos/administração & dosagem , Asfixia Neonatal/terapia , Cesárea , Parada Cardíaca/terapia , Miocárdio/patologia , Nascimento Prematuro , Propofol/administração & dosagem , Disfunção Ventricular Esquerda/prevenção & controle , Anestésicos Inalatórios/administração & dosagem , Animais , Animais Recém-Nascidos , Asfixia Neonatal/sangue , Asfixia Neonatal/fisiopatologia , Biomarcadores/sangue , Caspase 3/metabolismo , Modelos Animais de Doenças , Ativação Enzimática , Feminino , Idade Gestacional , Parada Cardíaca/sangue , Parada Cardíaca/fisiopatologia , Humanos , Recém-Nascido , Isoflurano/administração & dosagem , Ligadura , Miocárdio/metabolismo , Fosforilação , Gravidez , Proteínas Proto-Oncogênicas c-akt/metabolismo , Respiração Artificial , Ressuscitação , Fator de Transcrição STAT3/metabolismo , Ovinos , Volume Sistólico/efeitos dos fármacos , Fatores de Tempo , Troponina T/sangue , Ultrassonografia , Cordão Umbilical/cirurgia , Disfunção Ventricular Esquerda/sangue , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA