Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Perinatol ; 40(8): 1193-1201, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32433510

RESUMO

OBJECTIVE: To test the hypothesis that infants born <30 weeks' gestation supported by Seattle-PAP will have lower rates of continuous positive airway pressure (CPAP) failure than infants supported with conventional, Fisher&Paykel-CPAP (FP-CPAP). STUDY DESIGN: Randomized trial (3/2017-01/2019) at 5 NICUs. The primary outcome was CPAP failure; subgroup analyses (gestational age, receipt antenatal corticosteroids) were performed. RESULTS: A total of 232 infants were randomized. Infants in the Seattle-PAP and FP-CPAP groups had mean gestational ages of 27.0 and 27.2 weeks, respectively. We observed no differences in rates of treatment failure between Seattle-PAP (40/112, 35.7%) and FP-CPAP (38/120, 31.7%; risk difference, 4.1%; 95% CI, -8.1-16.2; P = 0.51). Subgroup analysis indicated no differences in rates of CPAP failure. We observed no differences between the two groups in frequencies of adverse events or duration of respiratory support. CONCLUSIONS: Among infants born <30 weeks' gestation, rates of CPAP failure did not differ between Seattle-PAP and FP-CPAP.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Síndrome do Desconforto Respiratório do Recém-Nascido , Feminino , Idade Gestacional , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal , Gravidez , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia
2.
PLoS One ; 13(3): e0193807, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29590143

RESUMO

BACKGROUND: Almost one million prematurely born infants die annually from respiratory insufficiency, predominantly in countries with limited access to respiratory support for neonates. The primary hypothesis tested in the present study was that a modified device for bubble nasal continuous positive airway pressure (Bn-CPAP) would provide lower work of spontaneous breathing, estimated by esophageal pressure-rate products. METHODS: Infants born <32 weeks gestation and stable on Bn-CPAP with FiO2 <0.30 were studied within 72 h following delivery. Esophageal pressures during spontaneous breathing were measured during 2 h on standard Bn-CPAP, then 2 h with Bn-CPAP using a modified bubble device presently termed Seattle-PAP, which produces a different pattern of pressure fluctuations and which provided greater respiratory support in preclinical studies, then 2 h on standard Bn-CPAP. RESULTS: All 40 infants enrolled completed the study and follow-up through 36 wks post menstrual age or hospital discharge, whichever came first. No infants were on supplemental oxygen at completion of follow-up. No infants developed pneumothoraces or nasal trauma, and no adverse events attributed to the study were observed. Pressure-rate products on the two devices were not different, but effort of breathing, assessed by areas under esophageal pressure-time curves, was lower with Seattle-PAP than with standard Bn-CPAP. CONCLUSION: Use of Seattle-PAP to implement Bn-CPAP lowers the effort of breathing exerted even by relatively healthy spontaneously breathing premature neonates. Whether the lower effort of breathing observed with Seattle-PAP translates to improvements in neonatal mortality or morbidity will need to be determined by studies in appropriate patient populations.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Recém-Nascido Prematuro/fisiologia , Respiração , Ampicilina/uso terapêutico , Análise de Variância , Antibacterianos/uso terapêutico , Área Sob a Curva , Esôfago/efeitos dos fármacos , Esôfago/fisiopatologia , Feminino , Seguimentos , Gentamicinas/uso terapêutico , Frequência Cardíaca , Humanos , Lactente , Recém-Nascido , Modelos Lineares , Masculino , Esforço Físico/efeitos dos fármacos , Pressão , Respiração/efeitos dos fármacos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA