Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Biomaterials ; 85: 54-64, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26854391

RESUMO

A single nanomaterial with multiple imaging contrasts and functions is highly desired for multiscale theragnosis. Herein, we demonstrate single 1-1.9 µm infrared-active FePt alloy nanoparticles (FePt NPs) offering unprecedented four-contrast-in-one molecular imaging - computed tomography (CT), magnetic resonance imaging (MRI), photoacoustic (PA) imaging, and high-order multiphoton luminescence (HOMPL) microscopy. The PA response of FePt NPs outperforms that of infrared-active gold nanorods by 3- to 5.6-fold under identical excitation fluence and particle concentrations. HOMPL (680 nm) of an isolated FePt NP renders spatial full-width-at-half-maximum values of 432 nm and 300 nm beyond the optical diffraction limit for 1230-nm and 920-nm excitation, respectively. The in vivo targeting function was successfully visualized using HOMPL, PA imaging, CT, and MRI, thereby validating FePt as a single nanomaterial system covering up to four types (Optical/PA/CT/MRI) of molecular imaging contrast, ranging from the microscopic level to whole-body scale investigation.


Assuntos
Meios de Contraste/química , Ferro/química , Nanopartículas Metálicas/química , Imagem Molecular , Platina/química , Animais , Linhagem Celular Tumoral , Luminescência , Imageamento por Ressonância Magnética , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Nanotubos/química , Técnicas Fotoacústicas , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
2.
Sci Rep ; 5: 8879, 2015 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-25748390

RESUMO

Using in vivo second harmonic generation (SHG) and third harmonic generation (THG) microscopies, we tracked the course of collagen remodeling over time in the same melanoma microenvironment within an individual mouse. The corresponding structural and morphological changes were quantitatively analyzed without labeling using an orientation index (OI), the gray level co-occurrence matrix (GLCM) method, and the intensity ratio of THG to SHG (RTHG/SHG). In the early stage of melanoma development, we found that collagen fibers adjacent to a melanoma have increased OI values and SHG intensities. In the late stages, these collagen networks have more directionality and less homogeneity. The corresponding GLCM traces showed oscillation features and the sum of squared fluctuation VarGLCM increased with the tumor sizes. In addition, the THG intensities of the extracellular matrices increased, indicating an enhanced optical inhomogeneity. Multiplying OI, VarGLCM, and RTHG/SHG together, the combinational collagen remodeling (CR) index at 4 weeks post melanoma implantation showed a 400-times higher value than normal ones. These results validate that our quantitative indices of SHG and THG microscopies are sensitive enough to diagnose the collagen remodeling in vivo. We believe these indices have the potential to help the diagnosis of skin cancers in clinical practice.


Assuntos
Colágenos Fibrilares/metabolismo , Colágenos Fibrilares/ultraestrutura , Melanoma/metabolismo , Melanoma/ultraestrutura , Neoplasias Cutâneas/ultraestrutura , Microambiente Tumoral/fisiologia , Animais , Linhagem Celular Tumoral , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Microscopia/métodos , Neoplasias Cutâneas/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA