Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Mol Genet Genomic Med ; 12(1): e2358, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38284444

RESUMO

BACKGROUND: Mega-corpus-callosum syndrome with cerebellar hypoplasia and cortical malformations is a rare neurological disorder that is associated with typical clinical and imaging features. The syndrome is caused by pathogenic variants in the MAST1 gene, which encodes a microtubule-associated protein that is predominantly expressed in postmitotic neurons in the developing nervous system. METHODS: Fetal DNA from umbilical cord blood samples and genomic DNA from peripheral blood lymphocytes were subjected to whole-exome sequencing. The potential causative variants were verified by Sanger sequencing. RESULTS: A 26-year-old primigravid woman was referred to our prenatal center at 25 weeks of gestation due to abnormal ultrasound findings in the brain of the fetus. The brain abnormalities included wide cavum septum pellucidum, shallow and incomplete bilateral lateral fissure cistern, bilateral dilated lateral ventricles, hyperplastic corpus callosum, lissencephaly, and cortical dysplasia. No obvious abnormalities were observed in the brainstem or cerebellum hemispheres, but the cerebellum vermis was small. Whole-exome sequencing identified a de novo, heterozygous missense variant, c.695T>C(p.Leu232Pro), in the MAST1 gene and a genetic diagnosis of mega-corpus-callosum syndrome was considered. CONCLUSION: This study is the first prenatal case of MAST1-related disorder reported in the Chinese population and has expanded the mutation spectrum of the MAST1 gene.


Assuntos
Vermis Cerebelar , Leucoencefalopatias , Malformações do Desenvolvimento Cortical , Malformações do Sistema Nervoso , Gravidez , Feminino , Humanos , Adulto , Vermis Cerebelar/diagnóstico por imagem , Cerebelo/diagnóstico por imagem , Cerebelo/anormalidades , Malformações do Desenvolvimento Cortical/genética , Feto/anormalidades , DNA , Deficiências do Desenvolvimento
2.
Zhonghua Yi Xue Yi Chuan Xue Za Zhi ; 40(10): 1306-1311, 2023 Oct 10.
Artigo em Chinês | MEDLINE | ID: mdl-37730237

RESUMO

OBJECTIVE: To assess the value of using flat-sided culture tubes for preparing chromosomes through chorionic villi (CV) and amniotic fluid (AF) cell cultures during prenatal diagnosis. METHODS: From February to March 2020, 157 CV samples and 147 AF samples subjected to prenatal diagnosis at the Maternal and Child Health Care Hospital of Guangxi Zhuang Autonomous Region were selected as the study subjects. For each sample, one flat-sided tube and one flask culture were set up by following the standard protocols. The methods were evaluated by comparing the cell growth, experimental process, quality of chromosome preparation and costs. RESULTS: The success rates for the culturing of CV and AF samples by the flat-sided culture tube method were 97.45% (153/157) and 97.96% (144/147), respectively. By contrast, the success rates for the conventional flask method were 98.72% (155/157) for CV and 98.64% (145/147) for AF samples. No significant difference was found between the two methods (P > 0.05). The average harvest time required by the flat-sided culture tube method was 8.45 days for CV and 9.43 days for AF cultures, whilst the average harvest time for conventional flask method was 9.05 days and 9.54 days, respectively. The flat-sided culture tube method for CV had required significantly shorter average harvest time than the conventional method (P < 0.001). No statistical significant difference was found in the average harvest time for AF by the two methods (P > 0.05). The conventional culturing method had required three containers with two sample transfers. By contrast, the flat-sided culture tube method was carried out in one tube without any sample transfer. The average total amount of medium used was 3.91 mL for each flat-sided culture tube and 6.26 mL for each conventional flask. CONCLUSION: The flat-sided culture tube method can provide a simple, cost-effective and error-reducing procedure for the CV and AF samples culture during prenatal diagnosis.


Assuntos
Amostra da Vilosidade Coriônica , Diagnóstico Pré-Natal , Criança , Feminino , Gravidez , Humanos , China , Líquido Amniótico , Proliferação de Células
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA