Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Radiology ; 269(2): 378-86, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23788717

RESUMO

PURPOSE: To determine the diagnostic accuracy of dynamic computed tomographic (CT) perfusion imaging of the myocardium for the detection of hemodynamically relevant coronary artery stenosis compared with the accuracy of coronary angiography and fractional flow reserve (FFR) measurement. MATERIALS AND METHODS: This study was approved by the institutional review board and the Federal Radiation Safety Council (Bundesamt für Strahlenschutz). All patients provided written informed consent. Thirty-two consecutive patients in adenosine stress conditions underwent dynamic CT perfusion imaging (14 consecutive data sets) performed by using a 256-section scanner with an 8-cm detector and without table movement. Time to peak, area under the curve, upslope, and peak enhancement were determined after calculation of time-attenuation curves. In addition, myocardial blood flow (MBF) was determined quantitatively. Results were compared with those of coronary angiography and FFR measurement by using a receiver operating characteristic (ROC) analysis. In addition, threshold values based on the Youden index and sensitivity and specificity were calculated. RESULTS: Area under the ROC curve, sensitivity, and specificity, respectively, were 0.67, 41.4% (95% confidence interval [CI]: 23.5%, 61.1%), and 86.6% (95% CI: 76.0%, 93.7%) for time to peak; 0.74, 58.6% (95% CI: 38.9%, 76.5%), and 83.6% (95% CI: 72.5%, 91.5%) for area under the curve; 0.87, 82.8% (95% CI: 64.2%, 94.1%), and 88.1% (95% CI: 77.8%, 94.7%) for upslope; 0.83, 82.8% (95% CI: 64.2%, 94.1%), and 89.6% (95% CI: 79.6%, 95.7%) for peak enhancement; and 0.86, 75.9% (95% CI: 56.5%, 89.7%), and 100% (95% CI: 94.6%, 100%) for MBF. The thresholds determined by using the Youden index were 148.5 HU · sec for area under the curve, 12 seconds for time to peak, 2.5 HU/sec for upslope, 34 HU for peak enhancement, and 1.64 mL/g/min for MBF. CONCLUSION: The semiquantitative parameters upslope and peak enhancement and the quantitative parameter MBF showed similar high diagnostic accuracy. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.13121441/-/DC1.


Assuntos
Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Comorbidade , Meios de Contraste , Angiografia Coronária , Teste de Esforço , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Fatores de Risco , Sensibilidade e Especificidade
2.
J Card Surg ; 24(5): 541-3, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19538226

RESUMO

The appearance of re-stenosis after repair of an interrupted aortic arch may be a surgical challenge due to adhesions. Here, we describe an approach using off-pump coronary artery bypass grafting techniques to reach the descending aorta through a median sternotomy in a patient with aortic arch stenosis after conduit repair. The 17-year-old patient with diagnoses of interrupted aortic arch and ventricular septal defect presented after two previous operations (one left lateral thoracotomy and one median sternotomy) with a stenosed vascular graft between ascending and descending aorta. Surgery was done via re-sternotomy without cardio-pulmonary bypass. An extraanatomic graft was used to connect ascending and descending aorta. When performing the distal anastomosis, the heart was exposed using a standard suction device. This case demonstrates that the use of modern techniques may facilitate surgical approaches dramatically. In our opinion the above-described technique is the first choice for all patients requiring arch repair following multiple previous operations, performed via sternotomy and thoracotomy.


Assuntos
Aorta Torácica/cirurgia , Estenose da Valva Aórtica/cirurgia , Ponte Cardiopulmonar/métodos , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Adolescente , Feminino , Humanos , Masculino , Reoperação , Esternotomia/métodos , Toracotomia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA