1.
Bioengineering (Basel) ; 11(2)2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38391656

RESUMO

In revision operations, ceramic heads of modular hip implants can be replaced. As the surface of the stem taper can be damaged, additional adapter sleeves are applied. The components are usually connected manually by the surgeon in a one-step procedure by hammer impacts. In this study, we investigated a two-step joining procedure with reproducible impaction force. First, the adapter sleeve and head were joined quasi-statically with a force of 2 kN using an assembly device. In the second step, these components were applied to the stem taper using a pulse-controlled instrument. For reference, the joints were assembled according to standard conditions using a tensile testing machine. An average pull-off force of 1309 ± 201 N was achieved for the components joined by the instrument, and the average measured values for the components joined by the testing machine were 1290 ± 140 N. All specimens achieved a force >350 N when released and therefore met the acceptance criterion defined for this study. This study showed that a modified procedure in two steps with a defined force has a positive effect on the reproducibility of the measured joining forces compared to previous studies.

2.
Bioengineering (Basel) ; 10(10)2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37892910

RESUMO

Modern hip implants have a modular design. In case of wear or other damage it allows surgeons to change the tribological partners, i.e., the acetabular liner and femoral ball. In both revision and primary surgery, the secure joining of the implant components is important for the success of the operation. The two components, namely the ceramic liner and hip cup, are connected via a conical press connection and should be concentrically aligned to avoid chipping. Malseated liners can reduce the life span in situ. The amount of the joining force, which is usually applied via a hammer, depends on the surgeon. In this study, an alternative joining method for acetabular ceramic liners in hip cups was investigated, which intends to make the process more reproducible and thus safer. For this purpose, a handpiece was used to apply a defined force impulse of 4 kN. For the concentric alignment of a ceramic liner in the hip cup, an adapter was developed based on findings via a qualitative finite element (FE) analysis. Insertion and pushout tests of the acetabular cup-liner connection were performed in the laboratory with the new instrument (handpiece with the connected adapter) to evaluate the functionality of the instrument and the reproducibility of the new insertion method. For comparison, liners and acetabular cups were joined using a testing machine according to the standard. The presented results demonstrate the technical proof-of-concept of the new joining method under laboratory conditions. They meet the acceptance criteria of established manufacturers, which proves the equivalency to proven methods for joining modular implant components. To verify the improvement of the new joining method compared to the conventionally used joining method, an application-oriented study with different surgeons and the new joining instrument under clinical conditions is necessary.

3.
Materials (Basel) ; 14(17)2021 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-34501197

RESUMO

Minimally invasive surgery is increasingly used in many medical operations because of the benefits for the patients. However, for the surgeons, accessing the situs through a small incision or natural orifice comes with a reduction of the degrees of freedom of the instrument. Due to friction of the mechanical coupling, the haptic feedback lacks sensitivity that could lead to damage of the tissue. The approach of this work to overcome these problems is to develop a control concept for position control and force estimation with shape memory alloys (SMA) which could offer haptic feedback in a novel handheld instrument. The concept aims to bridge the gap between manually actuated laparoscopic instruments and surgical robots. Nickel-titanium shape memory alloys are used for actuation because of their high specific energy density. The work includes the manufacturing of a functional model as a proof of concept comprising the development of a suitable forceps mechanism and electronic circuit for position control and gripping force measurement, as well as designing an ergonomic user interface with haptic force feedback.

4.
Materials (Basel) ; 10(1)2017 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-28772412

RESUMO

The biomaterials used to maintain or replace functions in the human body consist mainly of metals, ceramics or polymers. In orthopedic surgery, metallic materials, especially titanium and its alloys, are the most common, due to their excellent mechanical properties, corrosion resistance, and biocompatibility. Aside from the established Ti6Al4V alloy, shape memory materials such as nickel-titanium (NiTi) have risen in importance, but are also discussed because of the adverse effects of nickel ions. These might be reduced by specific surface modifications. In the present in vitro study, the osteoblastic cell line MG-63 as well as primary human osteoblasts, fibroblasts, and macrophages were cultured on titanium alloys (forged Ti6Al4V, additive manufactured Ti6Al4V, NiTi, and Diamond-Like-Carbon (DLC)-coated NiTi) to verify their specific biocompatibility and inflammatory potential. Additive manufactured Ti6Al4V and NiTi revealed the highest levels of metabolic cell activity. DLC-coated NiTi appeared as a suitable surface for cell growth, showing the highest collagen production. None of the implant materials caused a strong inflammatory response. In general, no distinct cell-specific response could be observed for the materials and surface coating used. In summary, all tested titanium alloys seem to be biologically appropriate for application in orthopedic surgery.