2.
J Neurosurg Spine ; : 1-7, 2020 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-32032959

RESUMO

OBJECTIVE: The level of radiation awareness by surgeons and residents in spinal surgery does not match the ubiquity of fluoroscopy in operating rooms in the United States. The present method of monitoring radiation exposure may contribute to the current deficiency in radiation awareness. Current dosimeters involve a considerable lag from the time that the surgical team is exposed to radiation to the time that they are provided with that exposure data. The objective of the current study was to assess the feasibility of monitoring radiation exposure in operating room personnel during lateral transpsoas lumbar interbody fusion (LLIF) and minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) procedures by using a wearable personal device with real-time feedback. METHODS: Operating room staff participating in minimally invasive surgical procedures under a single surgeon during a 6-month period were prospectively enrolled in this study. All radiation dose exposures were recorded for each member of the surgical team (surgeon, assistant surgeon, scrub nurse, and circulating nurse) using a personal dosimeter (DoseAware). Radiation doses were recorded in microsieverts (µSv). Comparisons between groups were made using ANOVA with the Tukey post hoc test and Student t-test. RESULTS: Thirty-nine patients underwent interbody fusions: 25 underwent LLIF procedures (14 LLIF alone, 11 LLIF with percutaneous screw placement [PSP]) and 14 underwent MI-TLIF. For each operative scenario per spinal level, the surgeon experienced significantly higher (p < 0.035) average radiation exposure (LLIF: 167.9 µSv, LLIF+PSP: 424.2 µSv, MI-TLIF: 397.9 µSv) than other members of the team, followed by the assistant surgeon (LLIF: 149.7 µSv, LLIF+PSP: 242.3 µSv, MI-TLIF: 274.9 µSv). The scrub nurse (LLIF: 15.4 µSv, LLIF+PSP: 125.7 µSv, MI-TLIF: 183.0 µSv) and circulating nurse (LLIF: 1.2 µSv, LLIF+PSP: 9.2 µSv, MI-TLIF: 102.3 µSv) experienced significantly lower exposures. Radiation exposure was not correlated with the patient's body mass index (p ≥ 0.233); however, it was positively correlated with increasing patient age (p ≤ 0.004). CONCLUSIONS: Real-time monitoring of radiation exposure is currently feasible and shortens the time between exposure and the availability of information regarding that exposure. A shortened feedback loop that offers more reliable and immediate data would conceivably raise the level of concern for radiation exposure in spinal surgeries and could alter patterns of behavior, leading to decreased exposures. Further studies are ongoing to determine the effect of real-time dosimetry in spinal surgery.

3.
World Neurosurg ; 122: e805-e811, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30391598

RESUMO

BACKGROUND: Visualization of the anatomy in minimally invasive surgery (MIS) of the spine is limited and dependent on radiographic imaging, leading to increased radiation exposure to patients and surgical staff. Ultra-low-radiation imaging (ULRI) with image enhancement is a novel technology that may reduce radiation in the operating room. The aim of this study was to compare radiation emission between standard-dose and ULRI fluoroscopy with image enhancement in patients undergoing MIS of the spine. METHODS: This study prospectively enrolled 60 consecutive patients who underwent lateral lumbar interbody fusion, lateral lumbar interbody fusion with percutaneous pedicle screws, or MIS transforaminal lumbar interbody fusion. Standard-dose fluoroscopy was used in 31 cases, and ULRI with image enhancement was used in 29 cases. All imaging emission and radiation doses were recorded. RESULTS: Radiation emission per level was significantly less with ULRI than with standard-dose fluoroscopy for lateral lumbar interbody fusion (36.4 mGy vs. 119.8 mGy, P < 0.001), per screw placed in lateral lumbar interbody fusion (15.4 mGy per screw vs. 47.1 mGy per screw, P < 0.001), and MIS transforaminal lumbar interbody fusion (24.4 mGy vs. 121.6 mGy, P = 0.003). These differences represented reductions in radiation emission of 69.6%, 67.3%, and 79.9%. Total radiation doses per case were also significantly decreased for the transpsoas approach by 68.8%, lateral lumbar interbody fusion with percutaneous pedicle screws by 65.8%, and MIS transforaminal lumbar interbody fusion by 81.0% (P ≤ 0.004). CONCLUSIONS: ULRI with image enhancement has the capacity to significantly decrease radiation emission in minimally invasive procedures without compromising visualization of anatomy or procedure safety.


Assuntos
Aumento da Imagem/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Exposição à Radiação/prevenção & controle , Idoso , Estudos de Coortes , Feminino , Humanos , Aumento da Imagem/normas , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/normas , Neurocirurgiões/normas , Exposição Ocupacional/normas , Parafusos Pediculares/normas , Estudos Prospectivos , Exposição à Radiação/normas , Fusão Vertebral/métodos , Fusão Vertebral/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA