Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Int J Surg Case Rep ; 83: 105973, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34004563

RESUMO

INTRODUCTION AND IMPORTANCE: Near infrared fluorescence imaging with indocyanine green (ICG) can facilitate the intraoperative tumour localization and therefore a complete resection. Cholangiocarcinoma is an aggressive tumour and complete resection improves the outcome. Therefore, it is necessary to localize the tumour exactly but the translation of the preoperative imaging into the intraoperative setting can be difficult based only on sonography, computed tomography or magnetic resonance imaging. CASE PRESENTATION/CLINICAL FINDINGS AND INVESTIGATIONS/INTERVENTIONS AND OUTCOME: In this case a hepatic lesion suspicious for cholangiocarcinoma was discovered accidentally. Further diagnostics were unable to prove the diagnosis, therefore right hepatectomy was recommended and performed. Preoperatively ICG was administered and near infrared imaging was used intraoperatively clearly localizing the tumour, thus facilitating the resection. The intra- and postoperative course was uneventful. RELEVANCE AND IMPACT: This case report supports the very promising intraoperative use of fluorescence imaging for the localization of superficial hepatic tumours. Timing and correct administration of ICG is important.

2.
J Hepatol ; 74(2): 419-427, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33065168

RESUMO

BACKGROUND & AIMS: CT may miss up to 30% of cases of colorectal liver metastases (CRLMs). We assessed the impact of contrast-enhanced ultrasound (CEUS) on the detection of CRLMs and on changes to the therapeutic strategy; additionally, we assessed the accuracy of CEUS in differentiating unclear focal liver lesions (FLLs) compared to staging-CT. METHODS: We prospectively analyzed all patients with newly diagnosed and histologically confirmed colorectal cancer (CRC) at our tertiary gastroenterological center between December 2015 and May 2019. CEUS was performed in a total of 296 patients without CRLMs after staging-CT using the contrast agent (SonoVue®). Standard of reference was obtained by MRI or histology to diagnose CRLMs missed by CT. Benign FLLs were confirmed by MRI or follow-up CT (mean follow-up interval: 18 months). RESULTS: Eight additional CRLMs were detected by CEUS (overall 2.7%; sensitivity 88.9%, specificity 99.0%, positive predictive value 100%, negative predictive value 99.6%). All patients with CRLMs detected only by CEUS were in tumor stage T3/T4 (4.0% additionally detected CRLMs). The number needed to screen to detect 1 additional CRLM by CEUS was 37 in all patients and 24.5 in T3/T4-patients. When results were reviewed by a board-certified radiologist and oncologist, the therapeutic strategy changed in 6 of these 8 patients. Among the 62 patients (20.9%) with unclear FLLs after staging-CT, CEUS determined the dignity (malignant vs. benign) of 98.4% of the FLLs. CONCLUSION: Overall, CEUS detected 2.7% additional CRLMs (including 4.0% in tumor stage T3/T4) with a significant impact on the oncological therapeutic strategy for 75% of these patients. Patients with tumor stage T3/T4 would particularly benefit from CEUS. We propose CEUS as the first imaging modality for CT-detected lesions of unknown dignity. LAY SUMMARY: In patients with newly diagnosed colorectal cancer, contrast-enhanced ultrasound (CEUS) detected additional liver metastases after computed tomography (CT). In the majority of these patients, the oncological therapy was changed after obtaining the CEUS results. After staging-CT, 21% of hepatic lesions remained unclear. In these cases, CEUS was accurate to either reveal or exclude liver metastasis in nearly all patients and could reduce costs (e.g., number of MRI scans).


Assuntos
Neoplasias Colorretais/patologia , Aumento da Imagem/métodos , Neoplasias Hepáticas , Metástase Neoplásica/diagnóstico por imagem , Fosfolipídeos/farmacologia , Hexafluoreto de Enxofre/farmacologia , Ultrassonografia/métodos , Idoso , Neoplasias Colorretais/terapia , Meios de Contraste/farmacologia , Feminino , Humanos , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética/métodos , Masculino , Oncologia/métodos , Oncologia/normas , Estadiamento de Neoplasias , Melhoria de Qualidade , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
4.
AJR Am J Roentgenol ; 207(2): 310-20, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27253268

RESUMO

OBJECTIVE: The purpose of this study was to prospectively investigate the clinical feasibility of adopting splenic enhancement for timing and triggering the acquisition of late hepatic arterial phase images during multiphasic liver MDCT for assessment of hypervascular tumors. SUBJECTS AND METHODS: Forty-eight patients (33 men, 15 women; median age, 59 years; chronic liver disease, 23 patients; portal venous hypertension, 17 patients) with a total of 81 hypervascular liver tumors underwent liver MDCT by random assignment to one of two scanning protocols. Scanning delay for the late hepatic arterial phase was determined by assessment of time-to-peak splenic enhancement (splenic-triggering protocol) or aortic enhancement (aortic-triggering protocol). Acquisition timing, vascular attenuation, liver attenuation and homogeneity, signal-to-noise ratio, tumor-to-liver contrast, and tumor-to-liver contrast-to-noise ratio were compared. Two blinded independent observers used Likert scales to score timing adequacy (3-point scale), diagnostic confidence (5-point scale), and per lesion conspicuity (4-point scale) for hypervascular tumor detection. RESULTS: The splenic- and aortic-triggering protocols had significant differences in mean late hepatic arterial phase imaging timing (splenic, 36 ± 6 seconds; aortic, 32 ± 3 seconds; p = 0.010). Images obtained with the splenic-triggering protocol had significantly better observer-based judgment of adequacy (splenic, 2.04; aortic, 1.58; p = 0.002). Mean attenuation and signal-to-noise ratios from liver and portal vein were significantly higher with the splenic- than with the aortic-triggering protocol (p < 0.0001). The splenic-triggering protocol was associated with significant improvement in homogeneity of liver attenuation (p < 0.0001). Although the splenic-triggering protocol was associated with significantly higher lesion conspicuity than was the aortic-triggering protocol (p = 0.022), there was no significant difference in tumor detection rate. CONCLUSION: Our results provide a clinical foundation for and proof of principle that the adoption of splenic enhancement renders an optimal temporal window for late hepatic arterial phase imaging during MDCT of the liver for assessment of hypervascular tumors.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Baço/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído
5.
Invest Radiol ; 51(4): 241-8, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26646307

RESUMO

OBJECTIVE: The aim of this study was to evaluate the potential of contrast media (CM) reduction in computed tomography angiography (CTA) of coronary artery bypass grafts (CABGs) when adapting CM volume to automatically selected tube voltages. MATERIAL AND METHODS: Sixty consecutive patients (mean age, 71 ± 14.5 years) with a total of 176 CABGs (692 bypass segments) underwent contrast-enhanced prospectively electrocardiography-gated high-pitch CTA with automated, attenuation-based tube voltage selection (100 ref. peak kilovoltage [kVp], 200 ref. mAs, tube voltages from 70-150 kVp in 10-kVp steps) using a third-generation 192-slice dual-source computed tomography scanner. Volume and flow of CM (370 mg/mL iodine) was adapted according to the tube voltages using iodine attenuation-curves derived from a foregoing phantom study. In patients, CM volumes ranged from 80 mL (flow rate, 7 mL/s) at 120 kVp to 48 mL (flow rate, 4.2 mL/s) at 80 kVp. Two independent, blinded readers evaluated subjective image quality of the proximal anastomosis, bypass graft, distal anastomosis, and postanastomotic native coronary artery using a 3-point Likert scale. Objective image quality (attenuation of graft and noise) was determined and contrast-to-noise ratio (CNR) was calculated. Volume computed tomography dose index and dose-length product of each CTA examination were noted. Cohen κ was used to define interreader agreement of subjective image quality. Regression analysis was used to determine relationships between tube voltage and vascular attenuation, image noise, and CNR. RESULTS: Using attenuation-based tube voltage selection, 5 patients (8%) were scanned at 80 kVp, 22 (37%) at 90 kVp, 11 (18%) at 100 kVp, 10 (17%) at 110 kVp, and 12 (20%) at 120 kVp. Agreement in subjective image quality between readers was good (κ = 0.678). Diagnostic image quality was achieved in 679 of 692 (98%) bypass segments in 169 of 176 bypass grafts (96%). Thirteen of 692 bypass segments (2%) in 7 of 176 bypass grafts (4%) were rated as nondiagnostic because of severe artifacts caused by motion or beam hardening (2 proximal anastomoses of sequential bypasses, 3 graft bodies, 5 distal anastomoses, and 3 postanastomotic coronary artery segments). Regression analysis revealed no significant relationship between the automatically selected tube voltages and objective image quality parameters (bypass graft attenuation: P = 0.315; noise: P = 0.433; and CNR: P = 0.168), indicating homogenous attenuation, noise, and CNR across tube voltage levels. Mean volume computed tomography dose index was 4.0 ± 0.9 mGy, and mean dose length product was 135.0 ± 29.6 mGy*cm. CONCLUSION: Adapting CM protocols to automatically selected tube voltage levels allows for low-volume CM CTA examinations of CABG grafts with diagnostic image quality.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Angiografia por Tomografia Computadorizada , Meios de Contraste/administração & dosagem , Ponte de Artéria Coronária , Iohexol/análogos & derivados , Idoso , Algoritmos , Feminino , Humanos , Iohexol/administração & dosagem , Masculino
6.
Eur Radiol ; 26(2): 459-68, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26037718

RESUMO

PURPOSE: To evaluate the potential of advanced modeled iterative reconstruction (ADMIRE) for optimizing radiation dose of high-pitch coronary CT angiography (CCTA). METHODS: High-pitch 192-slice dual-source CCTA was performed in 25 patients (group 1) according to standard settings (ref. 100 kVp, ref. 270 mAs/rot). Images were reconstructed with filtered back projection (FBP) and ADMIRE (strength levels 1-5). In another 25 patients (group 2), high-pitch CCTA protocol parameters were adapted according to results from group 1 (ref. 160 mAs/rot), and images were reconstructed with ADMIRE level 4. In ten patients of group 1, vessel sharpness using full width at half maximum (FWHM) analysis was determined. Image quality was assessed by two independent, blinded readers. RESULTS: Interobserver agreements for attenuation and noise were excellent (r = 0.88/0.85, p < 0.01). In group 1, ADMIRE level 4 images were most often selected (84%, 21/25) as preferred data set; at this level noise reduction was 40% compared to FBP. Vessel borders showed increasing sharpness (FWHM) at increasing ADMIRE levels (p < 0.05). Image quality in group 2 was similar to that of group 1 at ADMIRE levels 2-3. Radiation dose in group 2 (0.3 ± 0.1 mSv) was significantly lower than in group 1 (0.5 ± 0.3 mSv; p < 0.05). CONCLUSIONS: In a selected population, ADMIRE can be used for optimizing high-pitch CCTA to an effective dose of 0.3 mSv. KEY POINTS: • Advanced modeled IR (ADMIRE) reduces image noise up to 50% as compared to FBP. • Coronary artery vessel borders show an increasing sharpness at higher ADMIRE levels. • High-pitch CCTA with ADMIRE is possible at a radiation dose of 0.3 mSv.


Assuntos
Angiografia Coronária/métodos , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos
7.
Invest Radiol ; 50(10): 695-702, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26002623

RESUMO

OBJECTIVE: To determine the value of advanced virtual monoenergetic images (mono+) from dual-energy computed tomography (CT) of hyperattenuating and hypoattenuating liver lesions in various phantom sizes and patients in comparison with standard monoenergetic images (mono). MATERIALS AND METHODS: Anthropomorphic phantoms simulating 4 patient sizes (S, 300 × 200 mm; M, 350 × 250 mm; L, 400 × 300 mm; and XL, 600 × 450 mm) with a liver insert containing both hyperattenuating and hypoattenuating iodine-containing lesions were imaged with dose-equivalent dual-energy (100/150 Sn kilovolt [peak] [kV{p}]) and single-energy (120 kV[p]) protocols on a 192-slice dual-source CT system. In addition, 4 patients with 3 hypoattenuating and 3 hyperattenuating hepatocellular carcinoma were included and underwent dual-energy CT imaging with the same scanner at similar kV(p) settings (100/150 Sn kV[p]). Images were reconstructed with standard mono and with the mono+ algorithm at 10-kiloelectron volt (keV) intervals from 40 to 190 keV. Attenuation of the liver and lesions were measured, and contrast-to-noise ratios (CNRs) were calculated. Lesion conspicuity was rated by 2 blinded independent readers in all mono and mono+ data sets from 40 to 190 keV using a 5-point Likert scale (1, lowest conspicuity; and 5, highest conspicuity). RESULTS: Attenuation in the liver and in both hyperattenuating and hypoattenuating lesions did not differ between mono and mono+ (P = 0.41-0.49). Noise on mono+ was significantly lower than on mono for all phantom sizes (P < 0.05) and was increasing with phantom size. Hyperattenuating lesion CNR was highest for mono+ images at 40 keV in the S phantom (6.73), with significantly higher CNR for mono+ than for mono and for single energy (120 kV[p]) in all phantom sizes (all P < 0.001) except for the XL phantom. Hypoattenuating lesion CNR was highest for high-keV mono+ being significantly higher than on mono and on single-energy (120 kV[p]) images (all P < 0.001), except for the XL phantom with significantly higher CNR for mono (1.3) compared with mono+ (0.47) and 120 kV(p) (1.26). In patients, CNR curves of hyperattenuating hepatocellular carcinoma were in accordance with the phantom data, whereas hypoattenuating lesions demonstrate varying curves, some being in accordance with findings in phantoms. Interreader agreement for lesion conspicuity was very good (intraclass correlation, 0.95), with higher conspicuity scores for mono+ than for mono and single energy (120 kV[p]) at all phantom sizes (all P < 0.05) and within patients. CONCLUSION: Our ex vivo and patient data demonstrate added value for imaging of both hyperattenuating and hypoattenuating liver lesions with advanced virtual monoenergetic dual-energy CT by decreased noise, increased CNR, and higher lesion conspicuity, although with limitations in XL body sizes.


Assuntos
Tamanho Corporal , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
8.
BMC Med Imaging ; 13: 10, 2013 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-23506523

RESUMO

BACKGROUND: To evaluate the contrast agent performance of Gd-EOB-DTPA and Gd-BOPTA for detection and assessment of extrahepatic findings, semi-quantitatively and qualitatively. METHODS: 13 patients with 19 extrahepatic lesions underwent liver MRI with Gd-EOB-DTPA and Gd-BOPTA. Quantitative and relative SNR measurements were performed in each dataset in the arterial and portalvenous phase within the extrahepatic lesion, aorta, inferior vena cava, portal vein, spleen, pancreas and renal cortex. Further, relative CNR measurements were performed. Three readers assessed contrast quality using a five-point scale and choosing the preferred image dataset. Statistical analysis consisted of a Student's t-test with p < 0.05 deemed significant, a weighted kappa statistic for assessment of interobserver variability and an ROC analysis. RESULTS: Mean SNR after injection of Gd-BOPTA was significantly higher compared with Gd-EOB-DTPA for all measurements (p < 0.05). Mean relative SNR was also higher for Gd-BOPTA, but without being statistically significant. There was no significant difference in relative CNR. Interobserver agreement for selection of image preference was moderate (mean weighted kappa 0.485). The area under the curve for the ROC-analysis regarding contrast agent performance was 0.464. CONCLUSION: Even though mean SNR is significantly higher after injection of Gd-BOPTA compared with Gd-EOB-DTPA, there is no significant difference in relative CNR with extrahepatic lesions being assessed equally well. Visual impression may differ after injection of Gd-EOB-DTPA, but does not influence image interpretation. Extrahepatic findings can be assessed similarly to MRI after injection of Gd-BOPTA.


Assuntos
Neoplasias Abdominais/patologia , Gadolínio DTPA , Hepatócitos/patologia , Imageamento por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos , Abdome/patologia , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
9.
Invest Radiol ; 47(8): 468-74, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22717881

RESUMO

OBJECTIVE: The aim of this study was to compare the image quality of abdominal computed tomography scans in an anthropomorphic phantom acquired at different radiation dose levels where each raw data set is reconstructed with both a standard convolution filtered back projection (FBP) and a full model-based iterative reconstruction (MBIR) algorithm. MATERIALS AND METHODS: An anthropomorphic phantom in 3 sizes was used with a custom-built liver insert simulating late hepatic arterial enhancement and containing hypervascular liver lesions of various sizes. Imaging was performed on a 64-section multidetector-row computed tomography scanner (Discovery CT750 HD; GE Healthcare, Waukesha, WI) at 3 different tube voltages for each patient size and 5 incrementally decreasing tube current-time products for each tube voltage. Quantitative analysis consisted of contrast-to-noise ratio calculations and image noise assessment. Qualitative image analysis was performed by 3 independent radiologists rating subjective image quality and lesion conspicuity. RESULTS: Contrast-to-noise ratio was significantly higher and mean image noise was significantly lower on MBIR images than on FBP images in all patient sizes, at all tube voltage settings, and all radiation dose levels (P < 0.05). Overall image quality and lesion conspicuity were rated higher for MBIR images compared with FBP images at all radiation dose levels. Image quality and lesion conspicuity on 25% to 50% dose MBIR images were rated equal to full-dose FBP images. CONCLUSION: This phantom study suggests that depending on patient size, clinically acceptable image quality of the liver in the late hepatic arterial phase can be achieved with MBIR at approximately 50% lower radiation dose compared with FBP.


Assuntos
Diagnóstico por Computador/instrumentação , Artéria Hepática , Processamento de Imagem Assistida por Computador/instrumentação , Radiografia Abdominal/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Algoritmos , Simulação por Computador , Diagnóstico por Computador/métodos , Relação Dose-Resposta à Radiação , Humanos , Aumento da Imagem , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos
10.
Eur J Nucl Med Mol Imaging ; 39(6): 936-43, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22415598

RESUMO

PURPOSE: To investigate the clinical value of (18)F-fluorocholine PET/CT (CH-PET/CT) in treatment decisions in patients with recurrent prostate cancer (rPCA). METHODS: The study was a retrospective evaluation of 156 patients with rPCA and CH-PET/CT for restaging. Questionnaires for each examination were sent to the referring physicians 14-64 months after examination. Questions included information regarding initial extent of disease, curative first-line treatment, and the treatment plan before and after CH-PET/CT. Additionally, PSA values at diagnosis, after initial treatment, before CH-PET/CT and at the end of follow-up were also obtained from the questionnaires. RESULTS: Mean follow-up was 42 months. The mean Gleason score was 6.9 at initial diagnosis. Initial treatment was: radical prostatectomy in 110 patients, radiotherapy in 39, and combined prostatectomy and radiotherapy in 7. Median PSA values before CH-PET/CT and at the end of follow-up were 3.40 ng/ml and 0.91 ng/ml. PSA levels remained stable, decreased or were below measurable levels in 108 patients. PSA levels increased in 48 patients. In 75 of the 156 patients (48%) the treatment plan was changed due to the CH-PET/CT findings. In 33 patients the therapeutic plan was changed from palliative treatment to treatment with curative intent. In 15 patients treatment was changed from curative to palliative. In 8 patients treatment was changed from curative to another strategy and in 2 patients from one palliative strategy to another. In 17 patients the treatment plan was adapted. CONCLUSION: CH-PET/CT has an important impact on the therapeutic strategy in patients with rPCA and can help to determine an appropriate treatment.


Assuntos
Colina/análogos & derivados , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Neoplasias da Próstata/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Antígeno Prostático Específico/metabolismo , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/terapia , Recidiva , Estudos Retrospectivos
11.
Abdom Imaging ; 37(3): 457-64, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21870116

RESUMO

PURPOSE: To determine if MR cholangiography with Gd-EOB-DTPA can be used to assess cystic duct patency and to establish normal time range for reflux of contrast material into the cystic duct/gallbladder. MATERIALS AND METHODS: This retrospective study is HIPAA-compliant and IRB-approved with waiver for informed consent granted. From September 2008 to June 2009, 300 patients who underwent Gd-EOB-DTPA-enhanced MR imaging for various clinical indications, not specifically limited to evaluation for acute cholecystitis, were identified. 112 patients were excluded: prior cholecystectomy (n = 93), severe technical limitations (n = 9), or absence of appropriate clinical follow-up (n = 10). 188 total patients (82 male, 106 female, mean age 51.0 years) were included in the final dataset. Time between contrast administration and contrast reflux into the cystic duct/gallbladder on delayed phase imaging was measured. RESULTS: Reflux of contrast into the gallbladder was identified in 130/188 patients (69.1%) on delayed phase imaging. Average time to gallbladder reflux was 15:24 ± 5:51 minutes (range: 6:01-41:05 min). 58/188 patients (30.9%) demonstrated no reflux of contrast into the gallbladder at time of final delayed phase images. Of 58 patients who demonstrated no reflux into cystic duct/gallbladder, 15 patients demonstrated no extrahepatic biliary excretion, limiting evaluation of cystic duct patency. A total of 173 patients demonstrated biliary excretion of contrast with 76% overall sensitivity of detection of cystic duct patency. CONCLUSION: MR cholangiography with hepatobiliary MR contrast agents such as Gd-EOB-DTPA can demonstrate cystic duct patency with high sensitivity. MR protocols can be designed within a clinically feasible timeframe to optimize diagnosis of acute cholecystitis.


Assuntos
Colangiopancreatografia por Ressonância Magnética/métodos , Colecistite Aguda/diagnóstico , Meios de Contraste , Gadolínio DTPA , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Colecistite Aguda/diagnóstico por imagem , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Cintilografia , Estudos Retrospectivos , Sensibilidade e Especificidade
12.
Eur J Radiol ; 81(10): 2457-62, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22138122

RESUMO

PURPOSE: To compare intraindividual differences in enhancement pattern of hepatic hemangiomas between gadobenate dimeglumine (Gd-BOPTA) and gadoxetate disodium (Gd-EOB-DTPA)-enhanced 3T MR imaging. MATERIALS AND METHODS: This is a HIPAA-compliant, IRB-approved retrospective study with waiver for informed consent granted. From 10/07 to 5/09, 10 patients (2 males, 8 females; mean age, 57.3 years) with 15 hepatic hemangiomas (mean diameter, 4.4 ± 5.6 cm) underwent both Gd-BOPTA- and Gd-EOB-DTPA-enhanced 3T MR imaging (mean interval, 266 days; range, 38-462 days). Diagnosis of hemangioma was based on strict imaging criteria. MR imaging was obtained during three arterial, portal venous, and up to four delayed phases. During each phase, hemangioma-to-liver contrast-to-noise ratio (CNR) was measured for each lesion on both examinations. Statistical analysis was performed using paired Student's t-test. RESULTS: Hemangioma-to-liver CNR peaked during the portal venous phase (Gd-BOPTA: 48.9 ± 65.8, Gd-EOB-DTPA: 0.7 ± 3.8). During all imaging phases except the first arterial phase, hemangioma-to-liver CNR was significantly lower on Gd-EOB-DTPA-enhanced compared to Gd-BOPTA-enhanced MR images (p<0.05). Notably, Gd-EOB-DTPA yielded negative hemangioma-to-liver CNR (-2.5 ± 2.4) compared to Gd-BOPTA (40.7 ± 56.4) during the first delayed phase (7-8 min after contrast administration), remaining negative for the rest of the delayed phases (up to 26 min after contrast administration). CONCLUSION: The enhancement patterns of hepatic hemangiomas differs significantly between Gd-BOPTA and Gd-EOB-DTPA-enhanced 3T MR imaging. The smaller dose, shorter plasma half-life, and increased hepatobiliary uptake of Gd-EOB-DTPA leads to a negative CNR of hemangioma-to-liver on delayed phases and could create an imaging pitfall with this agent.


Assuntos
Gadolínio DTPA , Hemangioma/patologia , Aumento da Imagem/métodos , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Top Magn Reson Imaging ; 21(3): 149-56, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21847034

RESUMO

The gain in signal-to-noise ratio at 3 T magnetic resonance (MR) imaging produces many benefits for abdominal imaging applications, including the capability to reduce acquisition times and/or improve spatial resolution for a variety of pulse sequences, the potential for broader application of parallel imaging techniques, and an increased sensitivity to gadolinium-based contrast media. These advances have the potential of improving the accuracy of MR imaging in the detection, staging, treatment planning, and follow-up of patients with abdominal tumors. At the same time, because certain high-field-strength-related drawbacks could not be compensated for, abdominal 3 T MR imaging should be clinically implemented with caution in some patients (eg, patients with massive ascites).


Assuntos
Neoplasias Abdominais/diagnóstico , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Intensificação de Imagem Radiográfica , Neoplasias Abdominais/patologia , Meios de Contraste , Feminino , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Masculino , Invasividade Neoplásica/patologia , Estadiamento de Neoplasias , Efeitos da Radiação , Medição de Risco , Sensibilidade e Especificidade , Razão Sinal-Ruído
14.
Eur J Nucl Med Mol Imaging ; 35(2): 253-63, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17926036

RESUMO

PURPOSE: To evaluate the accuracy of [(18)F]-choline (FCH) positron emission tomography/computed tomography (PET/CT) for staging and restaging of prostate cancer. METHODS: FCH PET/CT was performed in 111 patients with prostate cancer using 200 MBq FCH: 43 patients [mean age 63 years; mean prostrate specific antigen (PSA) 11.58 microg/l] were examined for initial staging, and 68 patients (mean age 66.4 years) were examined for restaging (mean PSA 10.81 microg/l). FCH PET/CT results were correlated to histopathology, bone scan, morphology as revealed by magnetic resonance imaging (MRI) and CT, PET/CT follow-up and PSA follow-up after therapy. RESULTS: FCH PET/CT scans at initial staging correctly showed no metastases in 36/38 patients undergoing radical surgery, as confirmed by PSA levels <0.1 microg/l 6 months postoperatively. Lymphadenectomy was performed in 24 of these patients, revealing four false FCH-negative lymph nodes (LN). In one patient, only lymphadenectomy was performed since a FCH-positive LN was confirmed by histology. Four patients showed FCH-positive bone metastases, as proven by bone scan. FCH PET/CT scans at restaging correctly revealed local recurrence in 36 patients. No pathological FCH uptake was observed in 11 patients with biochemical recurrence. Twenty-three patients showed FCH-positive LN. Twenty LN were surgically removed in seven patients. Histopathology verified metastases in all LN, but revealed two additional metastastic, FCH-negative LN. Seventeen patients showed FCH-positive bone metastases, as proven by bone scan or MRI. Sensitivity to detect recurrent disease was 86%. CONCLUSION: The results obtained using FCH PET/CT scans for initial N-staging were discouraging, especially in terms of its inability to detect small metastases. Recurrent disease can be localized reliably in patients with PSA levels of >2 microg/l.


Assuntos
Colina , Radioisótopos de Flúor , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Próstata/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Radiology ; 244(2): 566-74, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17641374

RESUMO

PURPOSE: To prospectively determine the accuracy of positron emission tomography (PET)/computed tomography (CT) with added CT morphologic information for depiction of metastases in patients with high-risk melanoma and negative findings for metastases at PET, by using histologic findings or additional imaging and/or follow-up findings as reference standard. MATERIALS AND METHODS: Institutional review board approval was obtained. Informed consent was obtained from patients. One hundred twenty-four consecutive high-risk melanoma patients (65 female, 59 male; mean age, 54.4 years; range, 15-82 years) were included. Fluorine 18 fluorodeoxyglucose (FDG) PET/CT was performed. First, PET/CT scans were evaluated for presence of metastases with increased FDG uptake; CT anatomic location was determined. Lesions were considered metastases if there was focal uptake higher than that of background tissue. Second, coregistered CT images of combined PET/CT scans were evaluated for presence of lesions without FDG uptake. Findings were compared with reference standard findings to determine the accuracy of each evaluation. McNemar test was used to assess statistical differences in accuracy. RESULTS: In 53 of 124 patients, metastases were found. In 46 of 53 patients with metastases, lesions had increased FDG uptake. In seven patients with metastatic disease, metastases did not have increased FDG uptake (maximum standard uptake value [SUV], <1.5; n = 5) or had faint FDG uptake (maximum SUV, 2.5 and 2.9; n = 2)-findings that were inconclusive with PET alone. These lesions were interpreted as metastases only with coregistered CT images. Lesions missed with PET were located in the lungs, iliac lymph nodes, subcutis, and psoas muscle. Sensitivity, specificity, and accuracy, respectively, of PET/CT for depiction of metastases were 85%, 96%, and 91%, and those of PET/CT with dedicated CT interpretation were 98%, 94%, and 96% (P = .016). CONCLUSION: Dedicated analysis of coregistered CT images significantly improves the accuracy of integrated PET/CT for depiction of metastases in patients with high-risk melanoma.


Assuntos
Fluordesoxiglucose F18 , Melanoma/diagnóstico por imagem , Metástase Neoplásica/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Neoplasias Cutâneas/patologia , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Melanoma/secundário , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
16.
AJR Am J Roentgenol ; 188(5): W467-74, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17449746

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the diagnostic performance of planar 99mTc methylene diphosphonate bone scintigraphy compared with SPECT and SPECT fused with CT in patients with focal bone lesions of the axial skeleton. SUBJECTS AND METHODS: Thirty-seven patients with 42 focal lesions of the axial skeleton were included in this prospective study. All patients underwent planar scintigraphy, SPECT through the focal lesions, and SPECT-guided CT. SPECT and CT images then were fused digitally. The three types of images were evaluated separately from one another by two experienced reviewers working to consensus. Visibility of the lesions, diagnostic performance, and certainty in diagnosis were evaluated. Performance for specific diagnoses also was evaluated. Histologic, MRI, and clinical follow-up findings were used as the reference standard. RESULTS: Visibility of the lesions was significantly better with SPECT than with planar scintigraphy (p < 0.0001). Sensitivity and specificity for differentiation of benign and malignant bone lesions were 82% and 94% for planar scintigraphy, 91% and 94% for SPECT, and 100% and 100% for SPECT fused with CT. Differences between the three methods of differentiating benign and malignant lesions did not reach statistical significance. Certainty in diagnosis was significantly higher for SPECT fused with CT than for planar scintigraphy (p = 0.004) and SPECT (p = 0.004). A specific diagnosis was made with planar scintigraphy in 64% of cases, with SPECT in 86%, and with SPECT fused with CT in all cases. CONCLUSION: Planar scintigraphy may suffice for differentiating benign and malignant lesions of the axial skeleton, but SPECT fused with CT significantly increases certainty in diagnosis and is the best tool for making a specific diagnosis.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Difosfonatos , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada de Emissão , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Esqueleto
17.
Semin Nucl Med ; 37(1): 29-33, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17161037

RESUMO

Accurate lymph node staging is essential for the prognosis and treatment in patients with cancer. The sentinel lymph node is the first node to which lymphatic drainage and metastasis from the primary tumor occurs. In malignant melanoma and breast cancer, the sentinel lymph node detection and biopsy already have been implemented into clinical practice. Currently, 2 techniques are used to identify the sentinel lymph nodes: technetium-99m-labeled colloid and blue dye. After peritumoral injection, the material migrates through the lymphatics to the first lymph nodes draining the tumor. The precise anatomic localization of the sentinel lymph nodes is important for minimal invasive surgery and to avoid incomplete removal of the sentinel lymph nodes. All sentinel lymph nodes should be resected to achieve a complete nodal staging. In the inguinal or low-axillary nodal stations, planar scintigraphic images mostly are adequate for the localization of the sentinel lymph nodes. However, in the regions of the head and neck, the chest, and the pelvis, an imaging method for the more precise anatomic localization of the sentinel lymph nodes preoperatively is highly desired. Recently, integrated single-photon emission computed tomography and computed tomography (SPECT/CT) scanners have become available. Initial reports suggest that integrated SPECT/CT might have an additional value in sentinel lymph node scintigraphy in head and neck tumors and tumors draining to the pelvic lymph nodes. We evaluated the clinical use of integrated SPECT/CT in the identification of the sentinel lymph nodes in patients with operable breast cancer. In our experience, localization and identification of sentinel lymph nodes was more accurate by integrated SPECT/CT imaging in comparison with planar images and SPECT images, respectively. In this report, the experiences of sentinel lymph node imaging with SPECT/CT are summarized.


Assuntos
Neoplasias da Mama/diagnóstico , Aumento da Imagem/métodos , Linfonodos/diagnóstico por imagem , Técnica de Subtração , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Ensaios Clínicos como Assunto , Feminino , Humanos , Metástase Linfática , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
J Hepatol ; 45(1): 43-50, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16690156

RESUMO

BACKGROUND/AIMS: (1) To evaluate the diagnostic value of integrated positron emission and computed tomography (PET/CT) in comparison with contrast-enhanced CT (ceCT) to detect biliary tract tumors and associated distant and regional lymph node metastases and (2) to evaluate the impact of PET/CT on therapy management. METHODS: From January 2001 to March 2005, each patient who was treated for a malignancy of the biliary tract underwent PET/CT examination in addition to the standard work-up imaging. Data were prospectively collected and analyzed in comparison with ceCT. RESULTS: Sixty-one patients with malignancies of the biliary tract were included into the study. Diagnosis was proven in all patients either by histology or cytology. PET/CT detected all gallbladder cancers (n=14). PET/CT and ceCT provided a comparable accuracy for the primary intra- (n=14) and extra-hepatic cholangiocarcinomas (n=33). All distant metastases (12/12) were detected by PET/CT, but only 3/12 by ceCT (p<0.001). Regional lymph node metastases were detected by PET/CT and ceCT in only 12% vs. 24%. PET/CT findings resulted in a change of management in 17% of patients deemed resectable after standard work-up. CONCLUSIONS: PET/CT is particularly valuable in detecting unsuspected distant metastases which are not diagnosed by standard imaging. Thus, PET/CT staging has an important impact on selection of adequate therapy.


Assuntos
Neoplasias dos Ductos Biliares/patologia , Ductos Biliares Extra-Hepáticos , Ductos Biliares Intra-Hepáticos , Colangiocarcinoma/patologia , Neoplasias da Vesícula Biliar/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias dos Ductos Biliares/diagnóstico por imagem , Colangiocarcinoma/diagnóstico por imagem , Feminino , Neoplasias da Vesícula Biliar/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons , Recidiva , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA