Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Refract Surg ; 40(7): e499-e505, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007813

RESUMO

PURPOSE: To assess the effects of intraocular lens (IOL) decentration and tilt, as well as age, on postoperative visual function (corrected distance visual acuity [CDVA] and contrast sensitivity) by comparing an extended depth-of-focus IOL using higher order aspheric optics against a monofocal IOL from the same platform. METHODS: This retrospective observational study targeted patients without other eye diseases who underwent surgery to implant the Tecnis Eyhance OptiBlue or the monofocal IOL Tecnis OptiBlue 1-Piece (J&J Vision) during cataract surgery from November 2021 to December 2022. The effects of age, axial length, IOL decentration, tilt, and corneal higher order aberrations (HOAs) on the postoperative 5 m CDVA and area under log contrast sensitivity function (AULCSF) under photopic and scotopic conditions were evaluated within 3 months of surgery. RESULTS: No significant difference was found in postoperative CDVA between the Tecnis Eyhance OptiBlue group (n = 61 eyes) and the Tecnis OptiBlue 1-Piece group (n = 35 eyes), but AULCSF was significantly better in the Tecnis Eyhance OptiBlue group for photopic (1.58 ± 0.13 vs 1.46 ± 0.18; P = .002) and scotopic (1.71 ± 0.11 vs 1.59 ± 0.19; P = .002) eyes. Multivariate analysis showed a negative correlation between AULCSF and IOL decentration and age in the Tecnis Eyhance OptiBlue group (P < .01), with no significant correlation with tilt, axial length, and corneal HOAs. CONCLUSIONS: The Tecnis Eyhance OptiBlue yielded significantly better contrast sensitivity under photopic and scotopic conditions than the Tecnis OptiBlue 1-Piece. However, it is important to consider the effects of IOL decentration and age when evaluating the contrast sensitivity of the Tecnis Eyhance OptiBlue. [J Refract Surg. 2024;40(7):e499-e505.].


Assuntos
Sensibilidades de Contraste , Percepção de Profundidade , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Desenho de Prótese , Pseudofacia , Acuidade Visual , Humanos , Estudos Retrospectivos , Acuidade Visual/fisiologia , Masculino , Feminino , Sensibilidades de Contraste/fisiologia , Idoso , Pessoa de Meia-Idade , Pseudofacia/fisiopatologia , Percepção de Profundidade/fisiologia , Refração Ocular/fisiologia , Migração do Implante de Lente Intraocular/fisiopatologia , Idoso de 80 Anos ou mais , Período Pós-Operatório , Comprimento Axial do Olho , Aberrações de Frente de Onda da Córnea/fisiopatologia
2.
J Cataract Refract Surg ; 50(6): 611-617, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38350154

RESUMO

PURPOSE: To explore lens capsule pathological characteristics in intraocular lens (IOL) dislocation after cataract surgery in patients with atopic dermatitis (AD). SETTING: University hospital department of ophthalmology. DESIGN: Case series with clinicopathological correlations. METHODS: Lens capsules and surrounding tissues excised during surgery from eyes with AD (AD group) and eyes without AD (non-AD group) with IOL dislocation were histologically evaluated. Hematoxylin and eosin staining was used to assess abnormal changes in lens epithelial cells (LECs). Masson trichrome staining distinguished the fibrous metaplasia around the lens capsule into high-density and low-density fibrosis. Capsular splitting (thinning) was identified in both stained preparations. RESULTS: The IOL dislocation morphology in the AD group (10 eyes of 10 patients) included 7 cases of capsular bag dislocation (CBD) and 3 cases of dead bag syndrome (DBS), with an average duration to IOL dislocation of 11.5 ± 5.6 years. All patients in the non-AD group (12 eyes of 12 patients) had CBD, averaging 10.2 ± 5.7 years to dislocation. Abnormal LECs, low-density fibrosis, and capsular splitting were observed in 9 (90), 9 (90), and 6 (60) of the patients in the AD group compared with 6 (50), 3 (25), and 2 (18), respectively, in the non-AD group (total n [%]). CONCLUSIONS: Compared with the non-AD group, the AD group exhibited higher frequencies of morphological changes in LECs, low-density fibrosis around the lens capsule, and capsular splitting characteristics of DBS. These results suggest LEC degeneration and increased lens capsule fragility occurred in patients with AD.


Assuntos
Dermatite Atópica , Cápsula do Cristalino , Humanos , Cápsula do Cristalino/patologia , Masculino , Feminino , Pessoa de Meia-Idade , Dermatite Atópica/complicações , Adulto , Migração do Implante de Lente Intraocular/etiologia , Idoso , Implante de Lente Intraocular , Facoemulsificação , Fibrose , Células Epiteliais/patologia , Lentes Intraoculares , Estudos Retrospectivos , Extração de Catarata
3.
J Cataract Refract Surg ; 49(8): 853-857, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37276274

RESUMO

PURPOSE: To examine whether atopic cataracts are associated with thinner lenses. SETTING: Department of Ophthalmology, Jikei University Hospital, Tokyo, Japan. DESIGN: Retrospective matched case-control study. METHODS: 31 eyes with atopic cataracts, 62 with nonatopic cataracts, and 31 without cataracts were analyzed. Each group was matched for age (±4 years) and sex. RESULTS: The mean lens thickness (LT) was 3.76 ± 0.40 mm, 3.94 ± 0.49 mm, and 4.11 ± 0.40 mm in eyes with atopic cataracts, nonatopic cataracts, and normal lenses, respectively. Repeated-measures analysis of variance showed that the LT in the atopic cataract group was significantly thinner than that in the nonatopic cataract ( P = .036) and normal lens ( P < .001) groups. In multivariate logistic regression analysis, a thinner LT was negatively correlated with age (odds ratio [OR], 0.91; 95% CI, 0.86-0.96) and positively correlated with anterior subcapsular cataract (ASC) (OR, 5.61; 95% CI, 1.97-15.99). Atopy was not a significant factor. 24 (38.7%) of the 62 eyes with nonatopic cataracts and 24 (77.4%) of the 31 eyes with atopic cataracts had ASC. CONCLUSIONS: The lenses of eyes with atopic cataracts were thinner than those of controls. Atopic cataracts frequently present with anterior subcapsular opacity, which is associated with lens thinning.


Assuntos
Catarata , Cristalino , Humanos , Estudos de Casos e Controles , Estudos Retrospectivos , Olho
4.
J Biol Chem ; 278(11): 9761-7, 2003 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-12519760

RESUMO

Cytochrome P450 isolated from Bacillus subtilis (P450(BSbeta); molecular mass, 48 kDa) catalyzes the hydroxylation of a long-chain fatty acid (e.g. myristic acid) at the alpha- and beta-positions using hydrogen peroxide as an oxidant. We report here on the crystal structure of ferric P450(BSbeta) in the substrate-bound form, determined at a resolution of 2.1 A. P450(BSbeta) exhibits a typical P450 fold. The substrate binds to a specific channel in the enzyme and is stabilized through hydrophobic interactions of its alkyl side chain with some hydrophobic residues on the enzyme as well as by electrostatic interaction of its terminal carboxylate with the Arg(242) guanidium group. These interactions are responsible for the site specificity of the hydroxylation site in which the alpha- and beta-positions of the fatty acid come into close proximity to the heme iron sixth site. The fatty acid carboxylate group interacts with Arg(242) in the same fashion as has been reported for the active site of chloroperoxidase, His(105)-Glu(183), which is an acid-base catalyst in the peroxidation reactions. On the basis of these observations, a possible mechanism for the hydroxylation reaction catalyzed by P450(BSbeta) is proposed in which the carboxylate of the bound-substrate fatty acid assists in the cleavage of the peroxide O-O bond.


Assuntos
Bacillus subtilis/metabolismo , Sistema Enzimático do Citocromo P-450/química , Sistema Enzimático do Citocromo P-450/metabolismo , Ácidos Graxos/metabolismo , Arginina/química , Sítios de Ligação , Cristalografia por Raios X , Cisteína/química , Escherichia coli/enzimologia , Escherichia coli/metabolismo , Ácido Glutâmico/química , Histidina/química , Ligantes , Espectroscopia de Ressonância Magnética , Modelos Químicos , Modelos Moleculares , Mutagênese Sítio-Dirigida , Ácido Mirístico/farmacologia , Oxigênio/metabolismo , Ligação Proteica , Conformação Proteica , Dobramento de Proteína , Estrutura Terciária de Proteína , Proteínas Recombinantes/química , Proteínas Recombinantes/metabolismo , Espectrofotometria , Análise Espectral Raman , Especificidade por Substrato
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA