Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Surg Today ; 53(1): 52-61, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35701689

RESUMO

PURPOSE: Even if favorable cosmetic outcomes are obtained shortly after breast-conserving surgery (BCS), cosmetic changes may occur up to several years after BCS. In the present study, we evaluated cosmetic changes while focusing on changes in the nipple position after BCS. METHODS: We examined the long-term course of changes in the nipple position over time after BCS using the proportion of the distance between the sternal notch and nipple (PDSN) in 196 patients. We also evaluated risk factors for long-term nipple position changes. RESULTS: The median follow-up period was 9.9 years. Nipple position changes occurred within eight years after BCS and seemed to plateau beyond that point. The body mass index (BMI), breast size, proportion of excision volume and axillary treatment were significantly associated with the nipple position changes within one to five years after BCS. The BMI, breast size, axillary treatment, chemotherapy and hormonal therapy were significantly associated with the nipple position changes within five to eight years after BCS. CONCLUSIONS: After BCS, the nipple position changes occur within about eight years. Obesity, large breast size, large excision volume, axillary treatment, chemotherapy and hormone therapy were factors that affected the treated breast shrinkage and increase in the left-right difference after BCS.


Assuntos
Neoplasias da Mama , Mamoplastia , Humanos , Feminino , Mastectomia Segmentar , Mamilos/cirurgia , Estudos Retrospectivos , Neoplasias da Mama/cirurgia , Neoplasias da Mama/etiologia
2.
Asian J Surg ; 45(11): 2268-2272, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35000855

RESUMO

BACKGROUND: There is little information on the risk factors for fat necrosis after breast-conserving surgery using an inframammary adipofascial flap (IAF). METHODS: We conducted a retrospective cohort study from a single institution evaluating the risk factors for fat necrosis after breast-conserving surgery using an IAF (n = 41) performed from 2005 to 2020 for newly diagnosed stage 0-2 breast cancer or phyllodes tumor. RESULTS: Age (≥50 years of age vs. <50 years of age), mammographic density (fatty vs. other) and operation period (before vs. after revision of surgical procedure and patient indication) were significantly associated with fat necrosis (p = 0.006, p = 0.04 and p = 0.02, respectively). CONCLUSION: Our study suggested that the use of an IAF with crescent dermis and selection of appropriate cases for IAF after breast-conserving surgery may be useful for the purpose of reducing fat necrosis. Further study is needed.


Assuntos
Neoplasias da Mama , Carcinoma in Situ , Necrose Gordurosa , Mamoplastia , Neoplasias da Mama/patologia , Carcinoma in Situ/cirurgia , Necrose Gordurosa/etiologia , Necrose Gordurosa/prevenção & controle , Necrose Gordurosa/cirurgia , Feminino , Humanos , Mamoplastia/métodos , Mastectomia Segmentar/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Retalhos Cirúrgicos
3.
Oncol Lett ; 21(1): 36, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33262828

RESUMO

Although immunotherapy has been demonstrated to be promising in triple-negative (TN) breast cancer (BC), most BC cases are classified as non-TN. To enrich the responders for immunotherapy regardless of their subtypes, classification based on tumor-infiltrating lymphocyte (TIL) levels and programmed death ligand-1 (PD-L1) status may be useful. However, this classification has not been fully applied to BC. Furthermore, suppressive subsets in the local tumor microenvironment, such as tumor-associated macrophages (TAMs), which promote tumor progression, cannot be ignored to overcome immunotherapy resistance. The aims of the present study were to classify primary BC cases based on the TIL levels and PD-L1 status, and to identify suppressive immune subsets in each categorized group. A retrospective analysis of 73 patients with invasive BC was performed. The frequency of TILs was evaluated in HE-stained slides (10% cutoff), and PD-L1 levels (SP142; 1% cutoff), as well as immune subsets (CD3+, CD8+, FOXP3+, CD20+, CD68+ and CD204+ cells) were assessed using immunohistochemistry. It was revealed that 22% (16/73) of the tumors were categorized as TIL+PD-L1+, of which 69% (11/16) were TN type. By contrast, 66% (48/73) of the tumors were categorized as TIL-PD-L1-, of which 77% (37/48) were HR+ and HER2- types. The number of CD204+ M2-type macrophages was significantly associated with high histological grade (P=0.0246) and high Ki-67 (P=0.0152), whereas CD68+ macrophages were not associated with these factors. Furthermore, CD204+ macrophages and FOXP3+ Tregs accumulated in 88% (14/16) and 63% (10/16) of TIL+PD-L1+ tumors, respectively, compared with 20.8% (10/48) and 27.1% (13/48) of TIL-PD-L1- tumors. In conclusion, 22% of BC tumors were classified as TIL+PD-L1+ (69% were TN), which were enriched with suppressive immune subsets. These cell types may serve as potential novel immunotherapeutic targets.

4.
Psychogeriatrics ; 20(2): 156-162, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31448862

RESUMO

BACKGROUND: Early detection of mild cognitive impairment (MCI) and dementia is important to promptly start appropriate intervention. However, it is difficult to examine a patient using long and thorough cognitive tests in a general clinical setting. In this study, we aimed to investigate the diagnostic validity of the Addenbrooke's Cognitive Examination - III (ACE-III), Mini-ACE (M-ACE), Montreal Cognitive Assessment (MoCA), Hasegawa Dementia Scale-Revised (HDS-R), and Mini-Mental State Examination (MMSE) to identify MCI and dementia. METHODS: A total of 249 subjects (controls = 50, MCI = 94, dementia = 105) at a memory clinic participated in this study, and took the ACE-III, M-ACE, MoCA, HDS-R, and MMSE. After all examinations had been carried out, a conference was held, and the clinical diagnoses were established. RESULTS: The areas under the curve (AUC) of the ACE-III, M-ACE, MoCA, HDS-R, and MMSE for diagnosing MCI were 0.891, 0.856, 0.831, 0.808, and 0.782. The AUC of the ACE-III was significantly larger than those of the MoCA, HDS-R, and MMSE. The AUCs of the ACE-III, M-ACE, MoCA, HDS-R, and MMSE for diagnosing dementia were 0.930, 0.917, 0.854, 0.871, and 0.856. Thus, the AUCs of the ACE-III and M-ACE were significantly larger than those of the MoCA, HDS-R, and MMSE. CONCLUSION: The ACE-III is a useful cognitive instrument to detect MCI. For distinguishing dementia patients from non-dementia patients, the ACE-III and M-ACE are superior to the MoCA, HDS-R, and MMSE.


Assuntos
Disfunção Cognitiva/diagnóstico , Demência/diagnóstico , Testes de Estado Mental e Demência/normas , Idoso , Idoso de 80 Anos ou mais , Cognição , Feminino , Humanos , Japão , Masculino , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Exame Neurológico , Curva ROC , Reprodutibilidade dos Testes
5.
Asian J Surg ; 42(1): 228-234, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29661546

RESUMO

BACKGROUND: After the ACOSOG Z0011 trial, it became important to evaluate the number of metastatic axillary lymph nodes (LNs) preoperatively. The purpose of this paper is to confirm whether the number of metastases can be accurately diagnosed by preoperative computed tomography (CT), ultrasound sonography (US), and US-guided fine-needle aspiration cytology (FNAC). METHODS: We retrospectively analyzed the axillary LNs finding of preoperative CT/US of 470 breast cancer patients. Metastasis was suspected based on the following findings: LNs with a long-axis diameter of ≥10 mm or a short-axis diameter of ≥5 mm on CT, and LNs with the absence of a fatty hilum, focal cortical thickness or a cortical thickness ≥2 mm on US. We also examined the results of FNAC making a rapid bedside diagnosis (bedside-FNAC) of 162 LNs that were suspected to metastatic based on the US findings. RESULTS: On CT, all cases with ≥3 LNs with a long-axis diameter of ≥10 mm and a short-axis diameter of ≥5 mm had metastasis. However, there was no relationship between the number of detected LNs and the number of metastases. On US, 75.7% of LNs with the absence of a fatty hilum and all LNs with cortical thickness ≥6 mm had metastasis. The accuracy of bedside-FNAC for suspicious LNs was 100%. CONCLUSIONS: Although we can pick up LNs that are likely to have metastasis on CT/US, it was impossible to accurately predict the number of metastases on CT/US. However, bedside-FNAC of suspicious LNs could accurately predict the number of metastases.


Assuntos
Axila , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Metástase Linfática , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha Fina , Feminino , Humanos , Biópsia Guiada por Imagem , Pessoa de Meia-Idade , Período Pré-Operatório , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Ultrassonografia
6.
J Med Ultrason (2001) ; 43(3): 387-94, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27230095

RESUMO

PURPOSE: The purpose of this study was to evaluate the usefulness of a computer-aided diagnosis (CAD) scheme for improving the performance of clinicians to diagnose non-mass lesions appearing as hypoechoic areas on breast ultrasonographic images. METHODS: The database included 97 ultrasonographic images with hypoechoic areas: 48 benign cases [benign lesion with benign mammary tissue or fibrocystic disease (n = 20), fibroadenoma (n = 11), and intraductal papilloma (n = 17)] and 49 malignant cases [ductal carcinoma in situ (n = 17) and invasive ductal carcinoma (n = 32)]. Seven clinicians, three expert breast surgeons, and four general surgeons participated in the observer study. They were asked their confidence level concerning the possibility of malignancy in all 97 cases with and without the use of the CAD scheme. Receiver operating characteristic (ROC) analysis was performed to evaluate the usefulness of the CAD scheme. RESULTS: The areas under the ROC curve (AUC) improved for all observers when they used the CAD scheme and increased from 0.649 to 0.783 (P = 0.0167). Notably, the AUC for the general surgeon group increased from 0.625 to 0.793 (P = 0.045). CONCLUSIONS: This study showed that the performance of clinicians to diagnose non-mass lesions appearing as hypoechoic areas on breast ultrasonographic images was improved by the use of a CAD scheme.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Mama/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Ultrassonografia Mamária/métodos , Biópsia , Mama/patologia , Doenças Mamárias/patologia , Bases de Dados Factuais , Diagnóstico Diferencial , Humanos , Médicos , Curva ROC
7.
J Breast Cancer ; 18(1): 80-6, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25834615

RESUMO

PURPOSE: Although various strategies have been reported, there are no defined criteria for cosmetic evaluation methods after breast-conserving surgery (BCS). Since Asians tend to have smaller breasts, indistinct inframammary folds, and conspicuous scars, differences in the cosmetic results are expected. So we examined two subjective methods and one objective method to determine the differences, and elements necessary for a cosmetic evaluation after BCS. METHODS: Frontal photographs of 190 Japanese were evaluated using the Harris scale (Harris) and the evaluation method proposed by the Japanese Breast Cancer Society Sawai group (Sawai group) as the subjective methods, and the Breast Cancer Conservation Treatment cosmetic results (BCCT.core) as the objective method, respectively. In order to examine the necessary elements for developing a new ideal method, 100 out of 190 were selected and assessed separately by six raters using both the Harris and modified Sawai group methods in the observer assessment. The correlation between the two methods was examined using the Spearman rank-correlation coefficient. RESULTS: The results of the BCCT.core and the other two methods were clearly different. In the observer assessment, the consensuses of the six raters were evaluated as follows: 27, 27, 26, and 20 cases were evaluated as "excellent," "good," "fair," and "poor," respectively. For the Spearman rank-correlation coefficient, values higher than 0.7 indicated a strong correlation, as seen by the values of 0.909 for the breast shape and 0.345 for the scar. The breast shape accounted for the most significant part of the evaluation, and the scar had very little correlation. CONCLUSION: In this study, we recognized a clear difference between the subjective and objective evaluation methods, and identified the necessary elements for cosmetic evaluation. We would like to continue developing an ideal cosmetic evaluation that is similar to subjective one and is independent from raters.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA