Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Strahlenther Onkol ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38652131

RESUMO

This preliminary ethical appraisal from the STOPSTORM.eu consortium is meant to raise critical points that clinicians administering stereotactic arrhythmia radioablation should consider to meet the highest standards in medical ethics and thus promote quality of life of patients recruited for radiotherapy treatments at a stage in which they experience a significant degree of vulnerability.

2.
Inflamm Res ; 73(4): 515-530, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38308760

RESUMO

OBJECTIVE AND DESIGN: We aimed to identify cytokines whose concentrations are related to lung damage, radiomic features, and clinical outcomes in COVID-19 patients. MATERIAL OR SUBJECTS: Two hundred twenty-six patients with SARS-CoV-2 infection and chest computed tomography (CT) images were enrolled. METHODS: CCL18, CHI3L1/YKL-40, GAL3, ANG2, IP-10, IL-10, TNFα, IL-6, soluble gp130, soluble IL-6R were quantified in plasma samples using Luminex assays. The Mann-Whitney U test, the Kruskal-Wallis test, correlation and regression analyses were performed. Mediation analyses were used to investigate the possible causal relationships between cytokines, lung damage, and outcomes. AVIEW lung cancer screening software, pyradiomics, and XGBoost classifier were used for radiomic feature analyses. RESULTS: CCL18, CHI3L1, and ANG2 systemic levels mainly reflected the extent of lung injury. Increased levels of every cytokine, but particularly of IL-6, were associated with the three outcomes: hospitalization, mechanical ventilation, and death. Soluble IL-6R showed a slight protective effect on death. The effect of age on COVID-19 outcomes was partially mediated by cytokine levels, while CT scores considerably mediated the effect of cytokine levels on outcomes. Radiomic-feature-based models confirmed the association between lung imaging characteristics and CCL18 and CHI3L1. CONCLUSION: Data suggest a causal link between cytokines (risk factor), lung damage (mediator), and COVID-19 outcomes.


Assuntos
COVID-19 , Neoplasias Pulmonares , Humanos , Interleucina-6 , SARS-CoV-2 , Proteína 1 Semelhante à Quitinase-3 , Detecção Precoce de Câncer , Radiômica , Pulmão/diagnóstico por imagem , Citocinas , Quimiocinas CC
3.
Front Oncol ; 13: 1182971, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37534259

RESUMO

Background: Hematological malignancies (HMs) represent a heterogeneous group of diseases with diverse etiology, pathogenesis, and prognosis. HMs' accurate registration by Cancer Registries (CRs) is hampered by the progressive de-hospitalization of patients and the transition to molecular rather than microscopic diagnosis. Material and methods: A dedicated software capable of automatically identifying suspected HMs cases by combining several databases was adopted by Reggio Emilia Province CR (RE-CR). Besides pathological reports, hospital discharge archives, and mortality records, RE-CR retrieved information from general and biomolecular laboratories. Incidence, mortality, and 5-year relative survival (RS) reported according to age, sex, and 4 HMs' main categories, were noted. Results: Overall, 7,578 HM cases were diagnosed from 1996 to 2020 by RE-CR. HMs were more common in males and older patients, except for Hodgkin Lymphoma and Follicular Lymphoma (FL). Incidence showed a significant increase for FL (annual percent change (APC)=3.0), Myeloproliferative Neoplasms (MPN) in the first period (APC=6.0) followed by a significant decrease (APC=-7.4), and Myelodysplastic Syndromes (APC=16.4) only in the first period. Over the years, a significant increase was observed in 5-year RS for Hodgkin -, Marginal Zone -, Follicular - and Diffuse Large B-cell-Lymphomas, MPN, and Acute Myeloid Leukemia. The availability of dedicated software made it possible to recover 80% of cases automatically: the remaining 20% required direct consultation of medical records. Conclusions: The study emphasizes that HM registration needs to collect information from multiple sources. The digitalization of CRs is necessary to increase their efficiency.

4.
Diagnostics (Basel) ; 13(14)2023 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-37510195

RESUMO

Anterior segment optical coherence tomography (AS-OCT) allows the explore not only the anterior chamber but also the front part of the vitreous cavity. Our cross-sectional single-centre study investigated whether AS-OCT can distinguish between vitreous involvement due to vitreoretinal lymphoma (VRL) and vitritis in uveitis. We studied AS-OCT images from 28 patients (11 with biopsy-proven VRL and 17 with differential diagnosis uveitis) using publicly available radiomics software written in MATLAB. Patients were divided into two balanced groups: training and testing. Overall, 3260/3705 (88%) AS-OCT images met our defined quality criteria, making them eligible for analysis. We studied five different sets of grey-level samplings (16, 32, 64, 128, and 256 levels), finding that 128 grey levels performed the best. We selected the five most effective radiomic features ranked by the ability to predict the class (VRL or uveitis). We built a classification model using the xgboost python function; through our model, 87% of eyes were correctly diagnosed as VRL or uveitis, regardless of exam technique or lens status. Areas under the receiver operating characteristic curves (AUC) in the 128 grey-level model were 0.95 [CI 0.94, 0.96] and 0.84 for training and testing datasets, respectively. This preliminary retrospective study highlights how AS-OCT can support ophthalmologists when there is clinical suspicion of VRL.

5.
J Clin Med ; 12(12)2023 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-37373781

RESUMO

Intraoperative cell salvage reduces the need for allogeneic blood transfusion in complex cancer surgery, but concerns about the possibility of it re-infusing cancer cells have hindered its application in oncology. We monitored the presence of cancer cells on patient-salvaged blood by means of flow cytometry; next, we simulated cell salvage, followed by leucodepletion and irradiation on blood contaminated with a known amount of EpCAM-expressing cancer cells, assessing also residual cancer cell proliferation as well as the quality of salvaged red blood cell concentrates (RBCs). We observed a significant reduction of EpCAM-positive cells in both cancer patients and contaminated blood, which was comparable to the negative control after leucodepletion. The washing, leucodepletion and leucodepletion plus irradiation steps of cell salvage were shown to preserve the quality of RBCs in terms of haemolysis, membrane integrity and osmotic resistance. Finally, cancer cells isolated from salvaged blood lose their ability to proliferate. Our results confirm that cell salvage does not concentrate proliferating cancer cells, and that leucodepletion allows for the reduction of residual nucleated cells, making irradiation unnecessary. Our study gathers pieces of evidence on the feasibility of this procedure in complex cancer surgery. Nevertheless, it highlights the necessity of finding a definitive consensus through prospective trials.

6.
EJNMMI Phys ; 10(1): 31, 2023 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-37221434

RESUMO

BACKGROUND: 18F-FDG PET/CT imaging allows to study oncological patients and their relative diagnosis through the standardised uptake value (SUV) evaluation. During radiopharmaceutical injection, an extravasation event may occur, making the SUV value less accurate and possibly leading to severe tissue damage. The study aimed to propose a new technique to monitor and manage these events, to provide an early evaluation and correction to the estimated SUV value through a SUV correction coefficient. METHODS: A cohort of 70 patients undergoing 18F- FDG PET/CT examinations was enrolled. Two portable detectors were secured on the patients' arms. The dose-rate (DR) time curves on the injected DRin and contralateral DRcon arm were acquired during the first 10 min of injection. Such data were processed to calculate the parameters ΔpinNOR = (DRinmax- DRinmean)/DRinmax and ΔRt = (DRin(t) - DRcon(t)), where DRinmax is the maximum DR value, DRinmean is the average DR value in the injected arm. OLINDA software allowed dosimetric estimation of the dose in the extravasation region. The estimated residual activity in the extravasation site allowed the evaluation of the SUV's correction value and to define an SUV correction coefficient. RESULTS: Four cases of extravasations were identified for which ΔRt [(390 ± 26) µSv/h], while ΔRt [(150 ± 22) µSv/h] for abnormal and ΔRt [(24 ± 11) µSv/h] for normal cases. The ΔpinNOR showed an average value of (0.44 ± 0.05) for extravasation cases and an average value of (0.91 ± 0.06) and (0.77 ± 0.23) in normal and abnormal classes, respectively. The percentage of SUV reduction (SUV%CR) ranges between 0.3% and 6%. The calculated self-tissue dose values range from 0.027 to 0.573 Gy, according to the segmentation modality. A similar correlation between the inverse of ΔpinNOR and the normalised ΔRt with the SUV correction coefficient was found. CONCLUSIONS: The proposed metrics allowed to characterised the extravasation events in the first few minutes after the injection, providing an early SUV correction when necessary. We also assume that the characterisation of the DR-time curve of the injection arm is sufficient for the detection of extravasation events. Further validation of these hypotheses and key metrics is recommended in larger cohorts.

7.
J Pers Med ; 12(11)2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36579492

RESUMO

BACKGROUND: among cardiac arrhythmias, ventricular tachycardia (VT) is one that can lead to cardiac death, although significant progress has been made in its treatment, including the use of implantable cardioverter-defibrillators (ICD) and radiofrequency catheter ablation. Nevertheless, long-term recurrence rates remain in about half of patients and drastically impact the patient's quality of life. Moreover, recurrent ICD shocks are painful and are associated with higher mortality and worsening of heart failure. Recently, more and more experiences are demonstrating potential efficacy in the use of stereotactic body radiotherapy (SBRT) (also called cardiac radio-ablation) to treat this condition. In this paper, we report our experience in the use of cardiac radio-ablation for the treatment of refractory ventricular tachycardia with a focus on the technique used, along with a review of the literature and technical notes. CASE PRESENTATION: an 81-year-old male patient with a long history of non-ischemic dilated cardiomyopathy and mechanical mitral prosthesis underwent a biventricular cardioverter defibrillator implant after atrial ventricular node ablation. At the end of 2021, the number of tachycardias increased significantly to about 10 episodes per day. After failure of medical treatment and conventional RT catheter ablation, the patient was treated with SBRT for a total dose of 25 Gy in a single session at the site of the ectopic focus. No acute toxicity was recorded. After SBRT (follow-up 7 months) no other VT episodes were recorded. CONCLUSION: SBRT appears to be safe and leads to a rapid reduction in arrhythmic storms as treatment for VT without acute toxicity, representing one of the most promising methods for treating VT storms.

8.
Cancers (Basel) ; 14(19)2022 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-36230525

RESUMO

Glioblastoma multiforme (GBM) is the most aggressive astrocytic primary brain tumor, and concurrent temozolomide (TMZ) and radiotherapy (RT) followed by maintenance of adjuvant TMZ is the current standard of care. Despite advances in imaging techniques and multi-modal treatment options, the median overall survival (OS) remains poor. As an alternative to surgery, re-irradiation (re-RT) can be a therapeutic option in recurrent GBM. Re-irradiation for brain tumors is increasingly used today, and several studies have demonstrated its feasibility. Besides differing techniques, the published data include a wide range of doses, emphasizing that no standard approach exists. The current study aimed to investigate the safety of moderate-high-voxel-based dose escalation in recurrent GBM. From 2016 to 2019, 12 patients met the inclusion criteria and were enrolled in this prospective single-center study. Retreatment consisted of re-irradiation with a total dose of 30 Gy (up to 50 Gy) over 5 days using the IMRT (arc VMAT) technique. A dose painting by numbers (DPBN)/dose escalation plan were performed, and a continuous relation between the voxel intensity of the functional image set and the risk of recurrence in that voxel were used to define target and dose distribution. Re-irradiation was well tolerated in all treated patients. No toxicities greater than G3 were recorded; only one patient had severe G3 acute toxicity, characterized by muscle weakness and fatigue. Median overall survival (OS2) and progression-free survival (PFS2) from the time of re-irradiation were 10.4 months and 5.7 months, respectively; 3-, 6-, and 12-month OS2 were 92%, 75%, and 42%, respectively; and 3-, 6-, and 12-month PFS2 were 83%, 42%, and 8%, respectively. Our work demonstrated a tolerable tolerance profile of this approach, and the future prospective phase II study will analyze the efficacy in terms of PFS and OS.

9.
Phys Med Biol ; 67(16)2022 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-35785778

RESUMO

This topical review focuses on the applications of artificial intelligence (AI) tools to stereotactic body radiation therapy (SBRT). The high dose per fraction and the limited number of fractions in SBRT require stricter accuracy than standard radiation therapy. The intent of this review is to describe the development and evaluate the possible benefit of AI tools integration into the radiation oncology workflow for SBRT automation. The selected papers were subdivided into four sections, representative of the whole radiotherapy process: 'AI in SBRT target and organs at risk contouring', 'AI in SBRT planning', 'AI during the SBRT delivery', and 'AI for outcome prediction after SBRT'. Each section summarises the challenges, as well as limits and needs for improvement to achieve better integration of AI tools in the clinical workflow.


Assuntos
Radiocirurgia , Inteligência Artificial , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
10.
Curr Oncol ; 29(8): 5179-5194, 2022 07 22.
Artigo em Inglês | MEDLINE | ID: mdl-35892979

RESUMO

The purpose of this multi-centric work was to investigate the relationship between radiomic features extracted from pre-treatment computed tomography (CT), positron emission tomography (PET) imaging, and clinical outcomes for stereotactic body radiation therapy (SBRT) in early-stage non-small cell lung cancer (NSCLC). One-hundred and seventeen patients who received SBRT for early-stage NSCLC were retrospectively identified from seven Italian centers. The tumor was identified on pre-treatment free-breathing CT and PET images, from which we extracted 3004 quantitative radiomic features. The primary outcome was 24-month progression-free-survival (PFS) based on cancer recurrence (local/non-local) following SBRT. A harmonization technique was proposed for CT features considering lesion and contralateral healthy lung tissues using the LASSO algorithm as a feature selector. Models with harmonized CT features (B models) demonstrated better performances compared to the ones using only original CT features (C models). A linear support vector machine (SVM) with harmonized CT and PET features (A1 model) showed an area under the curve (AUC) of 0.77 (0.63-0.85) for predicting the primary outcome in an external validation cohort. The addition of clinical features did not enhance the model performance. This study provided the basis for validating our novel CT data harmonization strategy, involving delta radiomics. The harmonized radiomic models demonstrated the capability to properly predict patient prognosis.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Radiocirurgia , Carcinoma Pulmonar de Células não Pequenas/patologia , Humanos , Neoplasias Pulmonares/patologia , Recidiva Local de Neoplasia , Radiocirurgia/métodos , Estudos Retrospectivos
11.
Ann Palliat Med ; 11(11): 3555-3561, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35871277

RESUMO

BACKGROUND: The management of large tumors represent a concerning issue in the palliative setting. Since a surgical approach is excluded and systemic therapy has reported limited efficacy, the patients are commonly referred for radiation therapy as last resort. However, to improve quality of life and to avoid excessive toxicity, low doses of palliative radiotherapy (RT) are delivered. In these cases, with limited and short response. Lattice radiation therapy (LRT) represents an innovative technique aiming to increase tumor response without enhancing adjacent organs at risk (OAR) toxicity, by administering inhomogeneous doses with ablative high dose areas inside the tumor and low doses near the OAR. CASE DESCRIPTION: A 69-year-old male patient was admitted to our hospital complaining of sacral pain and mild dyspnea. After a suspicious opacity on X-ray, the chest computed tomography (CT), the positron emission tomography/CT (PET/CT) and the endobronchial ultra sound-guided transbronchial needle aspiration confirmed the diagnosis of a bulky sarcomatoid lung cancer (stage IV: cT4N3M1c). After an effective antalgic RT on the sacral metastasis and three lines of systemic therapy without response, the patient started to have a disabling dyspnea. Thus, we administered LRT on the bulky lesion. The patients experienced no significant toxicity, with a marked lesion response on the 3 month-follow CT and a significant improvement in symptoms and in his daily life. CONCLUSIONS: This is the first LRT treatment done in our Center and it provides another evidence in the efficacy of LRT planning. It shows how LRT could represent an innovative technique to provide durable response in large tumors, without increasing treatment-related toxicity.


Assuntos
Neoplasias Pulmonares , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Masculino , Humanos , Idoso , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Qualidade de Vida , Neoplasias Pulmonares/patologia , Cuidados Paliativos , Dispneia
12.
BMC Pulm Med ; 21(1): 327, 2021 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-34670551

RESUMO

BACKGROUND: Detection of small peripheral lung nodules is constantly increasing with the development of low dose computed tomography lung cancer screening programs. A tissue diagnosis is often required to confirm malignity, with endobronchial biopsies being associated with a lower pneumothorax rate than percutaneous approaches. Endoscopic diagnosis of peripheral small size lung nodules is however often challenging using traditional bronchoscopy and endobronchial ultrasound alone. New virtual bronchoscopic navigation techniques such as electromagnetic navigational bronchoscopy (ENB) have developed to improve peripheral navigation, with diagnostic yield however remaining in the 30-50% range for small lesions. Recent studies have shown the benefits of combining Cone beam computed tomography (CBCT) with ENB to improve diagnostic yield to up to 83%. The use of ENB however remains limited by disposable cost, bronchus sign dependency and inaccuracies due to CT to body divergence. CASE PRESENTATION: This case report highlights the feasibility and usefulness of CBCT-guided bronchoscopy for the sampling of lung nodules difficult to reach through traditional bronchoscopy because of nodule size and peripheral position. Procedure was scheduled in a mobile robotic hybrid operating room with patient under general anaesthesia. CBCT acquisition was performed to localize the target lesion and plan the best path to reach it into bronchial tree. A dedicated software was used to segment the lesion and the bronchial path which 3D outlines were automatically fused in real time on the fluoroscopic images to augment live guidance. Navigation to the lesion was guided with bronchoscopy and augmented fluoroscopy alone. Before the sampling, CBCT imaging was repeated to confirm the proper position of the instrument into the lesion. Four transbronchial needle aspirations (TBNA) were performed and the tissue analysis showed a primary lung adenocarcinoma. CONCLUSIONS: CBCT and augmented fluoroscopy technique is a safe and effective and has potential to improve early stage peripheral lesions endobronchial diagnostic yield without ENB. Additional studies are warranted to confirm its safety, efficacy and technical benefits, both for diagnosis of oncological and non-oncological disease and for endobronchial treatment of inoperable patients.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Fluoroscopia/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Adenocarcinoma de Pulmão/diagnóstico por imagem , Adenocarcinoma de Pulmão/patologia , Idoso , Humanos , Processamento de Imagem Assistida por Computador , Neoplasias Pulmonares/patologia , Masculino
13.
Front Oncol ; 11: 706034, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34712606

RESUMO

BACKGROUND: Agreement between planners and treating radiation oncologists (ROs) on plan quality criteria is essential for consistent planning. Differences between ROs and planning medical physicists (MPs) in perceived quality of head and neck cancer plans were assessed. MATERIALS AND METHODS: Five ROs and four MPs scored 65 plans for in total 15 patients. For each patient, the clinical (CLIN) plan and two or four alternative plans, generated with automated multi-criteria optimization (MCO), were included. There was always one MCO plan aiming at maximally adhering to clinical plan requirements, while the other MCO plans had a lower aimed quality. Scores were given as follows: 1-7 and 1-2, not acceptable; 3-5, acceptable if further planning would not resolve perceived weaknesses; and 6-7, straightway acceptable. One MP and one RO repeated plan scoring for intra-observer variation assessment. RESULTS: For the 36 unique observer pairs, the median percentage of plans for which the two observers agreed on a plan score (100% = 65 plans) was 27.7% [6.2, 40.0]. In the repeat scoring, agreements between first and second scoring were 52.3% and 40.0%, respectively. With a binary division between unacceptable (scores 1 and 2) and acceptable (3-7) plans, the median inter-observer agreement percentage was 78.5% [63.1, 86.2], while intra-observer agreements were 96.9% and 86.2%. There were no differences in observed agreements between RO-RO, MP-MP, and RO-MP pairs. Agreements for the highest-quality, automatically generated MCO plans were higher than for the CLIN plans. CONCLUSIONS: Inter-observer differences in plan quality scores were substantial and could result in inconsistencies in generated treatment plans. Agreements among ROs were not better than between ROs and MPs, despite large differences in training and clinical role. High-quality automatically generated plans showed the best score agreements.

14.
Phys Med Biol ; 66(13)2021 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-34098549

RESUMO

This study aimed to investigate if a commercial, knowledge-based tool for radiotherapy planning could be used to estimate the amount of sparing in organs at risk (OARs) in the re-planning strategy for adaptive radiotherapy (ART). Eighty head and neck (HN) VMAT Pareto plans from our institute's database were used to train a knowledge-based planning (KBP) model. An evaluation set of another 20 HN patients was randomly selected. For each patient in the evaluation set, the planning computed tomography (CT) and 2 sets of on-board cone-beam CT, corresponding to the middle and second half of the radiotherapy treatment course, were extracted. The original plan was re-calculated on a daily deformed CT (delivered dose-volume histogram (DVH)) and compared with the KBP DVH predictions and with the final KBP DVH after optimisation of the plan, which was performed on the same image sets. To evaluate the feasibility of this method, the range of KBP DVH uncertainties was compared with the gains obtained from re-planning. DVH differences and receiver operating characteristic (ROC) curve analysis were used for this purpose. On average, final KBP uncertainties were smaller than the gain in re-planning. Statistical tests confirmed significant differences between the two groups. ROC analysis showed KBP performance in terms of area under the curve values higher than 0.7, which confirmed a good accuracy in predicted values. Overall, for 48% of cases, KBP predicted a desirable outcome from re-planning, and the final dose confirmed an effective gain in 47% of cases. We have established a systematic workflow to identify effective OAR sparing in re-planning based on KBP predictions that can be implemented in an on-line, ART process.


Assuntos
Neoplasias de Cabeça e Pescoço , Radioterapia de Intensidade Modulada , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
15.
Phys Med ; 81: 227-236, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33485140

RESUMO

PURPOSE: The software Dosimetry Check (DC) reconstructs the 3D dose distribution on CT images data set by using EPID measured signal. This study aimed to evaluate DC for stereotactic body radiotherapy (SBRT) with unflattened photon beams (FFF) for dosimetric independent plan verification in pre-treatment modality. METHODS: DC v.4.1 was configured for Varian TrueBeam STx FFF beams equipped with EPID aS-1200. The DC FFF models were tested using arc open fields (from 1×1 cm2 to 15×15 cm2) and VMAT (Volumetric Modulated Arc Therapy) SBRT plans on phantom and patient CTs. DC dose distributions (DDC) were compared with that calculated by Eclipse with Acuros XB algorithm (DAXB) and one measured by Octavius 1000 SRS detector (DOCT). All differences were quantified in terms of the local 3D gamma passing rate (%GP), DVH and point dose differences. RESULTS: DC was configured for FFF VMAT using an appropriate correction procedure. %GP2%2mm (mean±standard deviation) of DOCT-DDC was 96.3±2.7% for open fields whereas it was 90.1±5.9% for plans on homogeneous phantom CT. However, average %GP3%3mm of DAXB-DDC was 95.0±4.1 for treatments on patient CT. The fraction of plans passing the %GP3%3mm DQA tolerance level [10% (50%) of maximum dose threshold] were 20/20 (14/20) and 18/20 (16/20) for OCT on phantom CT and DC on patient CT, respectively. CONCLUSIONS: DC characterization for FFF beams was performed. For stereotactic VMAT plan verifications DC showed good agreement with TPS whereas underlined discrepancies with Octavius in the high dose regions. A customized tolerance level is required for EPID-based VMAT FFF pre-treatment verification when DC system is applied.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
16.
Sci Rep ; 10(1): 21693, 2020 12 10.
Artigo em Inglês | MEDLINE | ID: mdl-33303795

RESUMO

The current framework of radiological protection of occupational exposed medical workers reduced the eye-lens equivalent dose limit from 150 to 20 mSv per year requiring an accurate dosimetric evaluation and an increase understanding of radiation induced effects on Lens cells considering the typical scenario of occupational exposed medical operators. Indeed, it is widely accepted that genomic damage of Lens epithelial cells (LEC) is a key mechanism of cataractogenesis. However, the relationship between apoptosis and cataractogenesis is still controversial. In this study biological and physical data are combined to improve the understanding of radiation induced effects on LEC. To characterize the occupational exposure of medical workers during angiographic procedures an INNOVA 4100 (General Electric Healthcare) equipment was used (scenario A). Additional experiments were conducted using a research tube (scenario B). For both scenarios, the frequencies of binucleated cells, micronuclei, p21-positive cells were assessed with different doses and dose rates. A Monte-Carlo study was conducted using a model for the photon generation with the X-ray tubes and with the Petri dishes considering the two different scenarios (A and B) to reproduce the experimental conditions and validate the irradiation setups to the cells. The simulation results have been tallied using the Monte Carlo code MCNP6. The spectral characteristics of the different X-ray beams have been estimated. All irradiated samples showed frequencies of micronuclei and p21-positive cells higher than the unirradiated controls. Differences in frequencies increased with the delivered dose measured with Gafchromic films XR-RV3. The spectrum incident on eye lens and Petri, as estimated with MCNP6, was in good agreement in the scenario A (confirming the experimental setup), while the mean energy spectrum was higher in the scenario B. Nevertheless, the response of LEC seemed mainly related to the measured absorbed dose. No effects on viability were detected. Our results support the hypothesis that apoptosis is not responsible for cataract induced by low doses of X-ray (i.e. 25 mGy) while the induction of transient p21 may interfere with the disassembly of the nuclear envelop in differentiating LEC, leading to cataract formation. Further studies are needed to better clarify the relationship we suggested between DNA damage, transient p21 induction and the inability of LEC enucleation.


Assuntos
Catarata/etiologia , Dano ao DNA/efeitos da radiação , Células Epiteliais/patologia , Células Epiteliais/efeitos da radiação , Cristalino/citologia , Cristalino/efeitos da radiação , Exposição Ocupacional/efeitos adversos , Doses de Radiação , Raios X/efeitos adversos , Células Cultivadas , Humanos , Método de Monte Carlo
17.
EJNMMI Phys ; 7(1): 63, 2020 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33044651

RESUMO

BACKGROUND: Internal dosimetry evaluation consists of a multi-step process ranging from imaging acquisition to absorbed dose calculations. Assessment of uncertainty is complicated and, for that reason, it is commonly ignored in clinical routine. However, it is essential for adequate interpretation of the results. Recently, the EANM published a practical guidance on uncertainty analysis for molecular radiotherapy based on the application of the law of propagation of uncertainty. In this study, we investigated the overall uncertainty on a sample of a patient following the EANM guidelines. The aim of this study was to provide an indication of the typical uncertainties that may be expected from performing dosimetry, to determine parameters that have the greatest effect on the accuracy of calculations and to consider the potential improvements that could be made if these effects were reduced. RESULTS: Absorbed doses and the relative uncertainties were calculated for a sample of 49 patients and a total of 154 tumours. A wide range of relative absorbed dose uncertainty values was observed (14-102%). Uncertainties associated with each quantity along the absorbed dose calculation chain (i.e. volume, recovery coefficient, calibration factor, activity, time-activity curve fitting, time-integrated activity and absorbed dose) were estimated. An equation was derived to describe the relationship between the uncertainty in the absorbed dose and the volume. The largest source of error was the VOI delineation. By postulating different values of FWHM, the impact of the imaging system spatial resolution on the uncertainties was investigated. DISCUSSION: To the best of our knowledge, this is the first analysis of uncertainty in molecular radiotherapy based on a cohort of clinical cases. Wide inter-lesion variability of absorbed dose uncertainty was observed. Hence, a proper assessment of the uncertainties associated with the calculations should be considered as a basic scientific standard. A model for a quick estimate of uncertainty without implementing the entire error propagation schema, which may be useful in clinical practice, was presented. Ameliorating spatial resolution may be in future the key factor for accurate absorbed dose assessment.

18.
PLoS One ; 15(8): e0236466, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32764764

RESUMO

AIM: The present work concerns the comparison of the performances of three systems for dosimetry in RPT that use different techniques for absorbed dose calculation (organ-level dosimetry, voxel-level dose kernel convolution and Monte Carlo simulations). The aim was to assess the importance of the choice of the most adequate calculation modality, providing recommendations about the choice of the computation tool. METHODS: The performances were evaluated both on phantoms and patients in a multi-level approach. Different phantoms filled with a 177Lu-radioactive solution were used: a homogeneous cylindrical phantom, a phantom with organ-shaped inserts and two cylindrical phantoms with inserts different for shape and volume. A total of 70 patients with NETs treated by PRRT with 177Lu-DOTATOC were retrospectively analysed. RESULTS: The comparisons were performed mainly between the mean values of the absorbed dose in the regions of interest. A general better agreement was obtained between Dose kernel convolution and Monte Carlo simulations results rather than between either of these two and organ-level dosimetry, both for phantoms and patients. Phantoms measurements also showed the discrepancies mainly depend on the geometry of the inserts (e.g. shape and volume). For patients, differences were more pronounced than phantoms and higher inter/intra patient variability was observed. CONCLUSION: This study suggests that voxel-level techniques for dosimetry calculation are potentially more accurate and personalized than organ-level methods. In particular, a voxel-convolution method provides good results in a short time of calculation, while Monte Carlo based computation should be conducted with very fast calculation systems for a possible use in clinics, despite its intrinsic higher accuracy. Attention to the calculation modality is recommended in case of clinical regions of interest with irregular shape and far from spherical geometry, in which Monte Carlo seems to be more accurate than voxel-convolution methods.


Assuntos
Lutécio/química , Imagens de Fantasmas/estatística & dados numéricos , Radioisótopos/química , Radiometria/estatística & dados numéricos , Receptores de Peptídeos/isolamento & purificação , Algoritmos , Humanos , Método de Monte Carlo , Doses de Radiação , Receptores de Peptídeos/química , Estudos Retrospectivos
19.
Comput Methods Programs Biomed ; 185: 105153, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31678792

RESUMO

BACKGROUND AND OBJECTIVES: Malignant lymphomas are cancers of the immune system and are characterized by enlarged lymph nodes that typically spread across many different sites. Many different histological subtypes exist, whose diagnosis is typically based on sampling (biopsy) of a single tumor site, whereas total body examinations with computed tomography and positron emission tomography, though not diagnostic, are able to provide a comprehensive picture of the patient. In this work, we exploit a data-driven approach based on multiple-instance learning algorithms and texture analysis features extracted from positron emission tomography, to predict differential diagnosis of the main malignant lymphomas subtypes. METHODS: We exploit a multiple-instance learning setting where support vector machines and random forests are used as classifiers both at the level of single VOIs (instances) and at the level of patients (bags). We present results on two datasets comprising patients that suffer from four different types of malignant lymphomas, namely diffuse large B cell lymphoma, follicular lymphoma, Hodgkin's lymphoma, and mantle cell lymphoma. RESULTS: Despite the complexity of the task, experimental results show that, with sufficient data samples, some cancer subtypes, such as the Hodgkin's lymphoma, can be identified from texture information: in particular, we achieve a 97.0% of sensitivity (recall) and a 94.1% of predictive positive value (precision) on a dataset that consists in 60 patients. CONCLUSIONS: The presented study indicates that texture analysis features extracted from positron emission tomography, combined with multiple-instance machine learning algorithms, can be discriminating for different malignant lymphomas subtypes.


Assuntos
Linfoma/classificação , Aprendizado de Máquina , Algoritmos , Conjuntos de Dados como Assunto , Humanos , Linfoma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Sensibilidade e Especificidade , Máquina de Vetores de Suporte , Tomografia Computadorizada por Raios X/métodos
20.
Phys Med ; 57: 153-159, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30738519

RESUMO

BACKGROUND: At present activity quantification is one of the most critical step in dosimetry calculation, and Partial Volume Effect (PVE) one of the most important source of error. In recent years models based upon phantoms that incorporate hot spheres have been used to establish recovery models. In this context the goal of this study was to point out the most critical issues related to PVE and to establish a model closer to a biological imaging environment. METHODS: Two different phantoms, filled with a 177Lu solution, were used to obtain the PVE Recovery Coefficients (RCs): a phantom with spherical inserts and a phantom with organ-shaped inserts. Two additional phantoms with inserts of various geometrical shapes and an anthropomorphic phantom were acquired to compare the real activities to predicted values after PVE correction. RESULTS: The RCs versus volume of the inserts produced two different curves, one for the spheres and one for the organs. After PVE correction, accuracy on activity quantification averaged over all inserts of three test phantoms passed from -26% to 1.3% (from 26% to 10% for absolute values). CONCLUSION: RCs is a simple method for PVE correction easily applicable in clinical routine. The use of two different models for organs and lesions has permitted to closely mimic the situation in a living subject. A marked improvement in the quantification of activity was observed when PVE correction was adopted, even if further investigations should be performed for more accurate models of PVE corrections.


Assuntos
Octreotida/análogos & derivados , Radioterapia , Receptores de Somatostatina/metabolismo , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA