Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Pediatr Radiol ; 54(5): 715-724, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38285191

RESUMO

BACKGROUND: The mediastinal shift angle is a new fetal magnetic resonance imaging (MRI) index that is reportedly correlated with postnatal survival in fetuses with congenital diaphragmatic hernia. However, its correlation in patients with congenital pulmonary airway malformation (CPAM) has not been assessed. OBJECTIVE: This study aimed to establish a normal range for the right/left mediastinal shift angles, to evaluate the mediastinal shift angle in fetuses with CPAM, to compare the mediastinal shift angle with the CPAM volume ratio, and to evaluate the predictive value of the mediastinal shift angle measurements. MATERIALS AND METHODS: To establish the normal range, we measured the mediastinal shift angle bilaterally in 124 fetuses without any lung abnormality (the control group). Subsequently, the mediastinal shift angle was measured in 32 fetuses pathologically diagnosed with CPAM. Moreover, the mediastinal shift angle and CPAM volume ratio were compared using fetal MRI. RESULTS: The mean values for the right/left mediastinal shift angles were 18.6°/26.3° and 39.2°/35.9° for control fetuses and fetuses with CPAM, respectively. The mediastinal shift angle and the CPAM volume ratio showed a positive statistical correlation. The area under the curve demonstrated high discriminatory accuracy for the mediastinal shift angle (0.76). CONCLUSION: The mediastinal shift angle has potential to replace the CPAM volume ratio for evaluating the severity of CPAM in fetal MRI.


Assuntos
Imageamento por Ressonância Magnética , Diagnóstico Pré-Natal , Humanos , Feminino , Imageamento por Ressonância Magnética/métodos , Diagnóstico Pré-Natal/métodos , Gravidez , Mediastino/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Pulmão/anormalidades , Pulmão/embriologia , Malformação Adenomatoide Cística Congênita do Pulmão/diagnóstico por imagem , Valores de Referência , Estudos Retrospectivos
2.
Mol Imaging Radionucl Ther ; 31(2): 169-171, 2022 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-35771098

RESUMO

A 50-year-old female patient underwent (18fluorine-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) following modified radical mastectomy for cancer of the left breast. Ten days before the PET/CT, the coronavirus disease-2019 (COVID-19) vaccine was injected intramuscularly into the right deltoid muscle. Increased (18F-FDG uptake of maximum standardized uptake value (11.0) was observed in the lymph nodes of the right axilla, which had not been observed in the previous PET/CT. The size of the oval-shaped lymph nodes was up to approximately 11×9 mm; however, it was larger than that observed on the previous PET/CT. We contemplate that the increased (18F-FDG uptake was a reactive change in the lymph nodes associated with the COVID-19 vaccine.

3.
J Med Invest ; 68(1.2): 96-104, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33994487

RESUMO

We aimed to assess the differential diagnostic efficacy of dynamic F-18 fluorodeoxyglucose (FDG) positron emission tomography / computed tomography (PET / CT) and to evaluate the appropriate scan timings for diagnosis of musculoskeletal lesions (MSLs). Dynamic scans (5-15 [phase 1], 15-25 [phase 2], and 25-35 [phase 3] min after F-18 FDG injection) and dual-time-point scans (1 and 2 h after injection) were acquired for 23 MSLs [4 benign MSLs (BMSLs). 10 primary malignant musculoskeletal tumors (PMMSTs), and 9 metastatic musculoskeletal tumors (MMSTs)]. We compared the maximum standardized uptake values (SUVmax) and corresponding retention indices for dynamic (RI-SUVdyn) and dual-time-point (RI-SUVdual) scans and evaluated diagnostic efficacy using receiver operating characteristic (ROC) curve analyses. The SUVmax gradually decreased or was almost identical with minimal fluctuation in 3 BMSLs and 1 PMMST. SUVmax increased over time after phase 2 in 18 malignant MSLs (MMSLs). There were significant differences in SUVmax (for all time phases) and RI-SUV dual between BMSLs and MMSLs and between PMMSTs and MMSTs. In the ROC analyses, the areas under the curve for SUV in phases 2 and 3 were highest for differentiating BMSLs from MMSLs and PMMSTs from MMSTs, respectively. Dynamic F-18 FDG PET / CT is valuable for diagnosis of musculoskeletal lesions. J. Med. Invest. 68 : 96-104, February, 2021.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Diagnóstico Diferencial , Humanos , Tomografia por Emissão de Pósitrons , Curva ROC , Compostos Radiofarmacêuticos
4.
Magn Reson Med Sci ; 17(4): 277-282, 2018 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-29238007

RESUMO

PURPOSE: We evaluated the utility of arterial spin labeling (ASL) imaging of tumor blood flow (TBF) for grading non-enhancing astrocytic tumors. MATERIALS AND METHODS: Thirteen non-enhancing astrocytomas were divided into high-grade (n = 7) and low-grade (n = 6) groups. Both ASL and conventional sequences were acquired using the same magnetic resonance machine. Intratumoral absolute maximum TBF (TBFmax), absolute mean TBF (TBFmean), and corresponding values normalized to cerebral blood flow (TBFmax and TBFmean ratios) were measured. The Mann-Whitney U test and receiver operating characteristic (ROC) curve analysis were used to assess the accuracy of TBF variables for tumor grading. RESULTS: Compared with low-grade astrocytoma, high-grade astrocytoma exhibited significantly greater absolute TBFmax (90.93 ± 24.96 vs 46.94 ± 20.97 ml/100 g/min, P < 0.001), TBFmean (58.75 ± 19.89 vs 31.16 ± 17.63 ml/100 g/min, P < 0.001), TBFmax ratio (3.34 ± 1.22 vs 1.35 ± 0.5, P < 0.001), and TBFmean ratio (2.15 ± 0.94 vs 0.88 ± 0.41, P < 0.001). The TBFmax ratio yielded the highest diagnostic accuracy (sensitivity 100%, specificity 86.3%), while absolute TBFmean yielded the lowest accuracy (sensitivity 85.7%, specificity 70.1%) by ROC analysis. CONCLUSION: Parameters from ASL perfusion imaging, particularly TBFmax ratio, may be useful for distinguishing high-grade from low-grade astrocytoma in cases with equivocal conventional MRI findings.


Assuntos
Astrocitoma , Neoplasias Encefálicas , Angiografia por Ressonância Magnética/métodos , Astrocitoma/irrigação sanguínea , Astrocitoma/diagnóstico por imagem , Neoplasias Encefálicas/irrigação sanguínea , Neoplasias Encefálicas/diagnóstico por imagem , Circulação Cerebrovascular/fisiologia , Humanos , Marcadores de Spin
5.
Ann Nucl Med ; 30(7): 501-5, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27256405

RESUMO

OBJECTIVE: The purpose of the study was to evaluate the hypothesis that patients having a vasovagal reaction (VVR) after blood vessel puncture show increased FDG accumulation in bilateral adrenal glands. METHODS: Over the past 8 years, 26 patients experienced a VVR after blood vessel puncture following intra-venous injection of FDG at our institution. Of the 26 patients, 16 underwent multiple-occasion FDG-PET/CT scans while suffering a VVR at only one examination. All 16 patients had no morphological abnormality in the adrenal glands on FDG-PET/CT and follow-up examination. For the 16, we retrospectively reviewed the FDG-PET/CT scan with respect to the adrenal glands and compared the result to that for the FDG-PET/CT scan of the same patient when there was no VVR event. We used both visual analysis and semi-quantitative analysis employing either maximum standardized uptake value (SUVmax) or adrenal-to-liver (A/L) SUVmax ratio. RESULTS: On visual analysis of the FDG-PET/CT with VVR, accumulations in both of the adrenal glands was judged positive, defined as higher than the hepatic accumulation, in 84 % of the cases. The SUVmax in the right adrenal gland was 2.79 ± 0.69 with VVR and 1.92 ± 0.33 without VVR; this value in the left adrenal gland was 3.07 ± 0.71 with VVR and 2.05 ± 0.39 without. Mean SUVmax of both adrenal glands was 2.93 ± 0.66 with VVR and 1.98 ± 0.35 without. The A/L SUVmax ratio in the right adrenal gland was 1.02 ± 0.26 with VVR and 0.69 ± 0.11 without; this value in the left was 1.11 ± 0.23 with VVR and 0.74 ± 0.15 without. The mean A/L SUVmax ratio of both adrenal glands was 1.06 ± 0.24 with VVR and 0.72 ± 0.13 without. Each parameter with VVR was significantly higher than that without. For the two adrenal glands, the mean SUVmax with VVR was 48 % higher than that without VVR. CONCLUSIONS: We confirmed the hypothesis that patients having a VVR after blood vessel puncture show increased FDG accumulation in their bilateral adrenal glands. This may reflect hyper-metabolism of the adrenal glands in synthesizing and secreting catecholamine.


Assuntos
Glândulas Suprarrenais/metabolismo , Fluordesoxiglucose F18/metabolismo , Punções/efeitos adversos , Síncope Vasovagal/etiologia , Síncope Vasovagal/metabolismo , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Glândulas Suprarrenais/diagnóstico por imagem , Adulto , Transporte Biológico , Feminino , Humanos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Síncope Vasovagal/diagnóstico por imagem
6.
Magn Reson Med Sci ; 14(4): 313-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26104074

RESUMO

PURPOSE: In the imaging of intra-axial brain tumors, we sometimes found areas of high signal intensity around the enhanced tumor lesions on arterial spin labeling (ASL) magnetic resonance (MR) imaging. We undertook this study to investigate the relationship between high signal intensity on ASL imaging outside the area of contrast enhancement (CE) and histological diagnosis of intra-axial brain tumors. METHODS: We examined images from 28 consecutive patients with intra-axial brain tumors who underwent ASL and CE MR imaging-three with low grade glioma (LGG), 13 with high grade glioma (HGG), six with metastasis, and six with primary central nervous system lymphoma (PCNSL)-and divided imaging findings into an "ASL dominant" group when hyperintensity on ASL was found outside the CE area and a "CE dominant" group when hyperintensity on ASL was not found outside the area of enhancement. We then analyzed the relationship between imaging findings and the histological diagnosis of the tumors. RESULTS: Four cases were excluded because of poor quality of ASL images, 7 cases were classified as ASL dominant, and 17 cases were classified as CE dominant. The histological diagnoses of ASL dominant cases were LGG in 3 cases, HGG in 3 cases, and PCNSL in one case. Those of CE dominant cases were HGG in 10 cases, metastasis in 5 cases, and PCNSL in 2 cases. All cases with brain metastasis were classified as CE dominant. CONCLUSION: The high signal intensity outside the area of contrast enhancement is probably caused by increased perfusion or vascular proliferation, which indicates the presence of glioma or PCNSL and not metastasis. This finding indicates a new utility for ASL images in the diagnosis of brain tumors as a supplement to the conventional measurement of perfusion obtained from ASL images.


Assuntos
Neoplasias Encefálicas/diagnóstico , Glioma/diagnóstico , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Astrocitoma/diagnóstico , Astrocitoma/patologia , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/secundário , Meios de Contraste , Diagnóstico Diferencial , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Feminino , Seguimentos , Gadolínio DTPA , Glioblastoma/diagnóstico , Glioblastoma/patologia , Glioma/patologia , Gliossarcoma/diagnóstico , Gliossarcoma/patologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Linfoma Difuso de Grandes Células B/diagnóstico , Linfoma Difuso de Grandes Células B/patologia , Espectroscopia de Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Neoplasias Neuroepiteliomatosas/diagnóstico , Neoplasias Neuroepiteliomatosas/patologia , Oligodendroglioma/diagnóstico , Oligodendroglioma/patologia , Marcadores de Spin
7.
Springerplus ; 4: 88, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25793147

RESUMO

This study sought to determine the diagnostic utility of perfusion parameters derived from dynamic contrast-enhanced (DCE) perfusion MRI with a short acquisition time (approximately 3.5 min) in patients with glioma, brain metastasis, and primary CNS lymphoma (PCNSL). Twenty-six patients with 29 lesions (4 low-grade glioma, 13 high-grade glioma, 7 metastasis, and 5 PCNSL) underwent DCE-MRI in a 3 T scanner. A ROI was placed on the hotspot of each tumor in maps for volume transfer contrast K (trans) , extravascular extracellular volume V e , and fractional plasma volume V p . We analyzed differences in parameters between tumors using the Mann-Whitney U test. We calculated sensitivity and specificity using receiver operating characteristics analysis. Mean K (trans) values of LGG, HGG, metastasis and PCNSL were 0.034, 0.31, 0.38, 0.44, respectively. Mean Ve values of each tumors was 0.036, 0.57, 0.47, 0.96, and mean Vp value of each tumors was 0.070, 0.086, 0.26, 0.17, respectively. Compared with other tumor types, low-grade glioma showed lower K (trans) (P < 0.01, sensitivity = 88%, specificity = 100%) and lower V e (P < 0.01, sensitivity = 96%, specificity = 100%). PCNSL showed higher V e (P < 0.01, sensitivity = 100%, specificity = 88%), but the other perfusion parameters overlapped with those of different histology. Kinetic parameters derived from DCE-MRI with short acquisition time provide useful information for the differential diagnosis of brain tumors.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA