Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
JBMR Plus ; 7(9): e10784, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37701150

RESUMO

Gorham-Stout disease (GSD), also called vanishing bone disease, is a rare osteolytic disease, frequently associated with lymphangiomatous tissue proliferation. The causative genetic background has not been noted except for a case with a somatic mutation in KRAS. However, in the present study, we encountered a case of GSD from a consanguineous family member. Whole-exome sequencing (WES) analysis focusing on rare recessive variants with zero homozygotes in population databases identified a homozygous missense variant (c.823G > C, p.Asp275His) in gasdermin D (GSDMD) in the patient and heterozygous in his unaffected brother. Because this variant affects the Asp275 residue that is involved in proteolytic cleavage by caspase-11 (as well as -4 and -5) to generate an activating p30 fragment required for pyroptotic cell death and proinflammation, we confirmed the absence of this cleavage product in peripheral monocytic fractions from the patient. A recent study indicated that a shorter p20 fragment, generated by further cleavage at Asp88, has a cell-autonomous function to suppress the maturation of osteoclasts to resorb bone matrix. Thus, the present study suggests for the first time the existence of hereditary GSD cases or novel GSD-like diseases caused by GSDMD deficiency. © 2023 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.

2.
JBJS Case Connect ; 10(2): e0143, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32649118

RESUMO

CASE: We encountered a case of locking of the distal radioulnar joint after a traumatic injury that restricted the supination and pronation of the wrist. The locking was released surgically with a good 2-year outcome. We found a tear between the dorsal aspect of the joint capsule and the triangular fibrocartilage complex (TFCC). The tear allowed the TFCC to displace volarly and become entrapped against the volar aspect of the ulnar head. CONCLUSION: The open approach facilitated visualization and understanding of this unusual injury pattern and allowed direct repair. Joint incongruity may not occur despite a locked joint.


Assuntos
Ciclismo/lesões , Procedimentos Ortopédicos/métodos , Fibrocartilagem Triangular/lesões , Traumatismos do Punho/cirurgia , Adulto , Artrografia , Feminino , Humanos , Traumatismos do Punho/diagnóstico por imagem
3.
Clin Neurophysiol ; 131(6): 1252-1266, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32299009

RESUMO

OBJECTIVE: Magnetospinography (MSG) has been developed for clinical application and is expected to be a novel neurophysiological examination. Here, we used an MSG system with sensors positioned in three orthogonal directions to record lumbar canal evoked magnetic fields (LCEFs) in response to peripheral nerve stimulation and to evaluate methods for localizing spinal cord lesions. METHODS: LCEFs from the lumbar area of seven rabbits were recorded by the MSG system in response to electrical stimulation of a sciatic nerve. LCEFs and lumbar canal evoked potentials (LCEPs) were measured before and after spinal cord compression induced by a balloon catheter. The lesion positions were estimated using LCEPs and computationally reconstructed currents corresponding to the depolarization site. RESULTS: LCEFs were recorded in all rabbits and neural activity in the lumbar spinal cord could be visualized in the form of a magnetic contour map and reconstructed current map. The position of the spinal cord lesion could be estimated by the LCEPs and reconstructed currents at the depolarization site. CONCLUSIONS: MSG can visualize neural activity in the spinal cord and localize the lesion site. SIGNIFICANCE: MSG enables noninvasive assessment of neural activity in the spinal canal using currents at depolarization sites reconstructed from LCEFs.


Assuntos
Eletrodiagnóstico/métodos , Potenciais Evocados/fisiologia , Condução Nervosa/fisiologia , Medula Espinal/fisiologia , Animais , Estimulação Elétrica , Coelhos , Compressão da Medula Espinal/fisiopatologia
4.
Spine (Phila Pa 1976) ; 39(3): E159-65, 2014 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-24153163

RESUMO

STUDY DESIGN: Retrospective analysis of prospectively collected data from consecutive patients undergoing 2 methods of transcranial electrical motor evoked potential (TCE-MEP) monitoring during cervical spine surgery. OBJECTIVE: To investigate the efficacy of biphasic transcranial electric stimulation, the deviation rate, amplitude of TCE-MEPs, complications, and sensitivity and specificity of TCE-MEP monitoring were compared between the biphasic and conventional monophasic stimulation methods. SUMMARY OF BACKGROUND DATA: With biphasic stimulation, unlike monophasic stimulation, measurement time can be reduced considerably because a single stimulation elicits bilateral responses almost simultaneously. However, no study has yet reported a detailed comparison of the 2 methods. METHODS: Examination 1: Amplitude and derivation rate of TCE-MEPs was compared for monophasic and biphasic stimulation in the same 31 patients with cervical compression myelopathy. Examination 2: Sensitivity, specificity, and complications of TCE-MEP monitoring were compared in 200 patients with cervical compression myelopathy who received monophasic or biphasic stimulation (100 patients each) during intraoperative monitoring. RESULTS: Examination 1: Derivation rates of biphasic stimulation in the deltoid, biceps brachii, abductor digiti minimi, and flexor hallucis brevis muscles were the same or higher than for monophasic stimulation. TCE-MEP amplitudes elicited by biphasic stimulation compared with monophasic stimulation were significantly larger in the biceps (paired t, P < 0.0001), but similar in the other 3 muscles. Examination 2: In the biphasic and monophasic stimulation groups, warnings were issued to surgeons in 10 and 11 cases, for a sensitivity of 100% for both groups and specificity of 97.8% and 96.7%, respectively. No complications related to stimulation were observed in any of the 200 patients. CONCLUSION: Biphasic stimulation had similar or higher derivation rates and equivalent sensitivity and specificity than monophasic stimulation. No complications were observed for either stimulation method. Biphasic stimulation is an effective TCE-MEP monitoring method for cervical spine surgery that may also reduce measurement time. LEVEL OF EVIDENCE: 4.


Assuntos
Vértebras Cervicais/cirurgia , Descompressão Cirúrgica/métodos , Estimulação Encefálica Profunda/métodos , Potencial Evocado Motor/fisiologia , Monitorização Intraoperatória/métodos , Doenças da Medula Espinal/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Vértebras Cervicais/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Doenças da Medula Espinal/diagnóstico , Doenças da Medula Espinal/fisiopatologia , Resultado do Tratamento
5.
Spine (Phila Pa 1976) ; 37(15): E913-21, 2012 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-22322375

RESUMO

STUDY DESIGN: A retrospective analysis of prospectively collected data from consecutive patients undergoing transcranial electrical motor-evoked potential (TCE-MEP: compound muscle action potentials) monitoring during cervical spine surgery. OBJECTIVE.: To divide the warning threshold of TCE-MEP amplitude changes on the basis of origin into the spinal tract and spinal segments and decide warning thresholds for each. SUMMARY OF BACKGROUND DATA: The parameter commonly used for the warning threshold in TCE-MEP monitoring is wave amplitude, but amplitude changes have not been examined by anatomical origin. METHODS: Intraoperative TCE-MEP amplitude changes were reviewed for 357 patients with cervical myelopathy. Most of the patients were monitored by transcranial electrical stimulated spinal-evoked potential combined with TCE-MEP. The warning threshold of TCE-MEP was taken as waveform disappearance. For each patient, amplitude changes were separated, according to origin, into the spinal tract and spinal segments and compared with clinical outcome. RESULTS: Assessable TCE-MEP waves were obtained in 350 cases. Disappearance of TCE-MEP waves, which were innervated by the spinal levels exposed to the surgical invasion, was seen in 11 cases. Disappearance of TCE-MEPs, which were innervated by the spinal levels inferior to them, was seen in 43 cases. There was no postoperative motor deficit in those cases. However, such deficits caused by spinal segment injury were seen in 2 cases, which showed that intraoperative amplitude decreased to 4.5% and 27%. CONCLUSION: If we had established the warning threshold as 30% of the control amplitude, we would likely have prevented both cases of postoperative motor deficits, but 106 (30.3%) cases would have become positive cases. If we had established the warning threshold separately as wave disappearance for the spinal tract and 30% of the control amplitude for the spinal segments, sensitivity and specificity would have been 100% and 83.7%, respectively. Dividing the warning threshold on the basis of origin of amplitude changes could reduce false-positive cases and prevent intraoperative injuries.


Assuntos
Potencial Evocado Motor/fisiologia , Monitorização Intraoperatória/métodos , Compressão da Medula Espinal/fisiopatologia , Compressão da Medula Espinal/cirurgia , Encéfalo/fisiopatologia , Vértebras Cervicais , Estimulação Elétrica/métodos , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Limiar Sensorial
6.
Clin Neurophysiol ; 123(8): 1656-61, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22285173

RESUMO

OBJECTIVE: To measure neuromagnetic evoked fields in the lumbar spinal canal. METHODS: Using a newly developed superconducting quantum interference device (SQUID) fluxmeter, neuromagnetic fields of 5 healthy male volunteers were measured at the surface of the lower back after stimulation of the tibial nerves at the ankles. For validation, we inserted a catheter-type electrode percutaneously in the lumbar epidural space in 2 of the subjects and measured cauda equina action potentials after tibial nerve stimulation. RESULTS: Neuromagnetic fields propagating from the intervertebral foramina into the spinal canal were measured, and the latencies of the magnetic fields corresponded largely with those of the cauda equina action potentials. CONCLUSIONS: We successfully measured ascending neuromagnetic fields originating at the nerve root and the cauda equina with high spatial resolution. Future studies will determine whether neuromagnetic field measurement of the lumbar spine can be a useful diagnostic method for the identification of the disordered site in spinal nerves. SIGNIFICANCE: We successfully measured neuromagnetic fields in the lumbar spinal canal, which have previously been difficult to verify. Future studies will determine whether neuromagnetic field measurement of the lumbar spine can be a useful diagnostic method for identifying disorders of spinal nerves.


Assuntos
Cauda Equina/fisiologia , Condução Nervosa/fisiologia , Canal Medular/fisiologia , Nervo Tibial/fisiologia , Adulto , Estimulação Elétrica , Eletrodiagnóstico/métodos , Humanos , Vértebras Lombares , Campos Magnéticos , Masculino
7.
J Orthop Sci ; 15(3): 371-80, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20559806

RESUMO

BACKGROUND: We previously reported the usefulness of neuromagnetic recordings for the diagnosis of disorders in peripheral nerves or the spinal cord. However, there have been no reports on incomplete conduction block of the spinal cord, which is clinically common in conditions such as cervical myelopathy. Here, we estimated the usefulness of measuring spinal cord evoked magnetic fields for evaluating incomplete conduction block. METHODS: Incomplete conduction block models of the spinal cord of the rabbit were established using a Fogarty balloon catheter that was inserted into the epidural space of the cervical spine. Electrical stimuli were applied to the lower thoracic spinal cord with an epidural catheter electrode. Spinal cord evoked potentials were recorded using epidural electrodes. Spinal cord evoked magnetic fields were recorded over the skin surface of the neck using a biomagnetometer. RESULTS: The decrease in the conduction velocity and amplitude at the compression site could be detected by spinal cord evoked potentials from the epidural space, confirming the spinal cord lesion. The waveforms of the magnetic fields showed a biphasic configuration. The distribution of magnetic fields showed a characteristic quadrupolar pattern propagating from caudal to cranial. After compression, the amplitude and the conduction velocity of the magnetic fields decreased, and the distribution of magnetic fields were attenuated and decelerated near the compression site especially in the trailing magnetic fields. Diagnosis of the incomplete conduction block was thus possible. CONCLUSIONS: We report the first measurement of the spinal cord evoked magnetic field in the intact spinal cord from the skin surface and that it can be applied to incomplete conduction block of the injured spinal cord. The use of a biomagnetometer is promising as a less-invasive method for clinically evaluating spinal cord function.


Assuntos
Eletrodiagnóstico/métodos , Campos Eletromagnéticos , Potencial Evocado Motor , Síndromes de Compressão Nervosa/diagnóstico , Compressão da Medula Espinal/diagnóstico , Animais , Modelos Animais de Doenças , Eletrodiagnóstico/instrumentação , Condução Nervosa , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA