Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ophthalmol Sci ; 4(6): 100544, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39139547

RESUMO

Purpose: To develop a 3-dimensional corneal construct suitable for in vitro studies of disease conditions and therapies. Design: In vitro human corneal constructs were created using chemically crosslinked collagen and chondroitin sulfate extracellular matrix and seeded with 3 human corneal cell types (epithelial, stromal, and endothelial) together with neural cells. The neural cells were derived from hybrid neuroblastoma cells and the other cells used from immortalized human corneal cell lines. To check the feasibility and characterize the constructs, cytotoxicity, cell proliferation, histology, and protein expression studies were performed. Results: Optimized culture condition permitted synchronized viability across the cell types within the construct. The construct showed a typical appearance for different cellular layers, including healthy appearing, phenotypically differentiated neurons. The expected protein expression profiles for specific cell types within the construct were confirmed with western blotting. Conclusions: An in vitro corneal construct was successfully developed with maintenance of individual cell phenotypes with anatomically correct cellular loci. The construct may be useful in evaluation of specific corneal disorders and in developing different corneal disease models. Additionally, the construct can be used in evaluating drug targeting and/or penetration to individual corneal layers, testing novel therapeutics for corneal diseases, and potentially reducing the necessity for animals in corneal research at the early stages of investigation. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

2.
Sci Rep ; 12(1): 9108, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35650270

RESUMO

Development of an artificial cornea can potentially fulfil the demand of donor corneas for transplantation as the number of donors is far less than needed to treat corneal blindness. Collagen-based artificial corneas stand out as a regenerative option, having promising clinical outcomes. Collagen crosslinked with chemical crosslinkers which modify the parent functional groups of collagen. However, crosslinkers are usually cytotoxic, so crosslinkers need to be removed from implants completely before application in humans. In addition, crosslinked products are mechanically weak and susceptible to enzymatic degradation. We developed a crosslinker free supramolecular gelation strategy using pyrene conjugated dipeptide amphiphile (PyKC) consisting of lysine and cysteine; in which collagen molecules are intertwined inside the PyKC network without any functional group modification of the collagen. The newly developed collagen implants (Coll-PyKC) are optically transparent and can effectively block UV light, are mechanically and enzymatically stable, and can be sutured. The Coll-PyKC implants support the growth and function of all corneal cells, trigger anti-inflammatory differentiation while suppressing the pro-inflammatory differentiation of human monocytes. Coll-PyKC implants can restrict human adenovirus propagation. Therefore, this crosslinker-free strategy can be used for the repair, healing, and regeneration of the cornea, and potentially other damaged organs of the body.


Assuntos
Colágeno , Córnea , Colágeno/metabolismo , Córnea/metabolismo , Humanos , Próteses e Implantes , Regeneração , Raios Ultravioleta
3.
Commun Biol ; 4(1): 608, 2021 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-34021240

RESUMO

The long-term survival of biomaterial implants is often hampered by surgery-induced inflammation that can lead to graft failure. Considering that most corneas receiving grafts are either pathological or inflamed before implantation, the risk of rejection is heightened. Here, we show that bioengineered, fully synthetic, and robust corneal implants can be manufactured from a collagen analog (collagen-like peptide-polyethylene glycol hybrid, CLP-PEG) and inflammation-suppressing polymeric 2-methacryloyloxyethyl phosphorylcholine (MPC) when stabilized with the triazine-based crosslinker 4-(4,6-Dimethoxy-1,3,5-triazin-2-yl)-4-methylmorpholinium chloride. The resulting CLP-PEG-MPC implants led to reduced corneal swelling, haze, and neovascularization in comparison to CLP-PEG only implants when grafted into a mini-pig cornea alkali burn model of inflammation over 12 months. Implants incorporating MPC allowed for faster nerve regeneration and recovery of corneal sensation. CLP-PEG-MPC implants appear to be at a more advanced stage of regeneration than the CLP-PEG only implants, as evidenced by the presence of higher amounts of cornea-specific type V collagen, and a corresponding decrease in the presence of extracellular vesicles and exosomes in the corneal stroma, in keeping with the amounts present in healthy, unoperated corneas.


Assuntos
Álcalis/toxicidade , Queimaduras Químicas/complicações , Colágeno/farmacologia , Córnea/citologia , Hidrogéis/administração & dosagem , Inflamação/prevenção & controle , Fosforilcolina/química , Animais , Materiais Biocompatíveis/química , Queimaduras Químicas/patologia , Colágeno/química , Humanos , Hidrogéis/química , Inflamação/etiologia , Inflamação/patologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Suínos , Porco Miniatura
4.
Indian J Hematol Blood Transfus ; 37(1): 162-166, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33707851

RESUMO

Imatinib, the first Tyrosine Kinase Inhibitor (TKI) used for the treatment of chronic myeloid leukaemia (CML) has revolutionized the management by inhibiting BCR-ABL tyrosine kinase. According to earlier reports there are concerns regarding the adverse effect of imatinib on haemostasis by causing platelet dysfunction. Here we studied platelet function using platelet aggregometry, in 19 CML chronic phase (CML-CP) patients on imatinib therapy, in complete haematologic response (CHR). The median duration of imatinib therapy before performing the test was 154 days. This study reveals that there are large inter-individual variations in platelet functions among imatinib treated patients and different levels of variability have been seen for different agonists. Most common aggregation abnormality (< 50% aggregation) was seen with low dose collagen (1 µg/ml) in 31.57% patients. Despite in-vitro platelet aggregation defects, none of the patients showed any bleeding symptoms. This enigma can possibly be explained by the fact that platelet specific agonists, epinephrine and collagen act in synergy for platelet aggregation compared against individual low dose agonists, supported by ex-vivo experiments in normal healthy control group (n = 5) (p value < 0.0004 for epinephrine, p value < 0.0001 for collagen). This experiment was also confirmed in a CML-CP patient. In future, more studies are needed to find out the exact mechanism of this inhibition.

5.
Acta Biomater ; 96: 330-344, 2019 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-31284096

RESUMO

To address the shortcomings associated with corneal transplants, substantial efforts have been focused on developing new modalities such as xenotransplantion. Xenogeneic corneas are anatomically and biomechanically similar to the human cornea, yet their applications require prior decellularization to remove the antigenic components to avoid rejection. In the context of bringing decellularized corneas into clinical use, sterilization is a crucial step that determines the success of the transplantation. Well-standardized sterilization methods, such as gamma irradiation (GI), have been applied to decellularized porcine corneas (DPC) to avoid graft-associated infections in human recipients. However, little is known about the effect of GI on decellularized corneal xenografts. Here, we evaluated the radiation effect on the ultrastructure, optical, mechanical and biological properties of DPC. Transmission electron microscopy revealed that gamma irradiated decellularized porcine cornea (G-DPC) preserved its structural integrity. Moreover, the radiation did not reduce the optical properties of the tissue. Neither DPC nor G-DPC led to further activation of complement system compared to native porcine cornea when exposed to plasma. Although, DPC were mechanically comparable to the native tissue, GI increased the mechanical strength, tissue hydrophobicity and resistance to enzymatic degradation. Despite these changes, human corneal epithelial, stromal, endothelial and hybrid neuroblastoma cells grew and differentiated on DPC and G-DPC. Thus, GI may achieve effective tissue sterilization without affecting critical properties that are essential for corneal transplant survival.


Assuntos
Córnea/química , Transplante de Córnea , Desinfecção , Raios gama , Alicerces Teciduais/química , Animais , Córnea/patologia , Xenoenxertos , Humanos , Suínos
6.
Ocul Surf ; 16(3): 322-330, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29627599

RESUMO

PURPOSE: To make the Boston keratoprosthesis (B-KPro), together with its carrier corneal graft, more easily procured, transported and stored, as well as less expensive, easier for the surgeon to implant and safer for the patient, it is proposed that the B-KPro-graft combination be pre-assembled by an expert technician, followed by sterilization with gamma ray irradiation (GI) allowing long-term storage at room temperature. For this to be possible, it must be shown that the B-KPro itself (not only the graft) remains unharmed by the irradiation. METHODS: Polymethyl methacrylate (PMMA) discs and B-KPros were submitted to either ethylene oxide sterilization or different doses of GI. Cell biocompatibility, mechanical strength and optical quality were evaluated. The feasibility of assembling the B-KPro to a corneal graft, and gamma-radiate afterwards, was also assessed. RESULTS: There were no differences in cell biocompatibility between the samples. The optical evaluation showed high levels of transparency for all the groups. The absorbance of ultraviolet was higher for the groups treated with GI. The mechanical evaluation by nanoindentation showed no alterations of the PMMA discs after GI. The flexure test revealed a similar mechanical behavior. Technically, pre-assembly and GI of the B-KPro revealed no problems. CONCLUSIONS: Sterilization of B-KPro using GI has no detrimental influence on the device. The pre-assembly of B-KPro to a donor cornea, followed by gamma sterilization, emerges as an efficient and safe procedure.


Assuntos
Órgãos Artificiais , Doenças da Córnea/cirurgia , Raios gama , Próteses e Implantes , Esterilização/métodos , Materiais Biocompatíveis , Humanos , Teste de Materiais , Preservação de Órgãos/métodos , Polimetil Metacrilato
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA