1.
RSC Adv ; 14(15): 10768-10775, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38572343

RESUMO

Nickel foam modified by hollow sphere NiCo2O4 particles was successfully prepared via a hydrothermal method using nanosphere SiO2 particles as the hard template for the hollow structure. Characterisation using SEM-EDX and TEM confirmed the structure as multiwalled hollow spheres with an average size of 270 nm, while characterisation using SEM, XRD, and XPS confirmed that the NiCo2O4 particles were attached on the surface of the nickel foam. BET analysis showed that the surface area of the synthesized NiCo2O4@Ni foam was nearly three times higher compared to that of the unmodified Ni foam. Investigation of the NiCo2O4-modified nickel foam as an electrode for the detection of glucose in sodium hydroxide solution showed high linearity of the anodic currents (R2 = 0.99) in the concentration range of 0-2.5 µM with sensitivity of 0.060 mA µM-1 and an estimated limit of detection of 0.060 µM. Excellent stability of the current response was also obtained with a relative standard deviation of 1.51% (n = 10). Furthermore, the developed sensor demonstrates strong applicability for glucose detection in real samples of human blood plasma, making it highly suitable for practical use. The results indicate that the material is promising for the further development of nickel-based sensors.

2.
Anal Methods ; 14(7): 726-733, 2022 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-35107103

RESUMO

Bimetallic copper-gold (Cu@Au) nanoparticles were synthesized and utilised to modify boron-doped diamond (BDD) electrodes. Nanorod particles with a diameter size of around 10 nm and a length of around 20 nm were successfully synthesized. These nanoparticles were then attached to the BDD surface by using allylamine as the bridge. Comparison among the BDD modified with Cu@Au and individual gold nanoparticles showed that Cu@Au nanoparticles created around 3 times higher gold coverage on the BDD surface than normal gold nanoparticles. It was also found that the use of allylamine as the bridge can attach more gold than copper nanoparticles. Moreover, around two times higher current responses of oxygen reduction reaction were observed at Cu@Au-modified BDD. Good linearity in a concentration range from 2 to 9 ppm could be achieved with a sensitivity of 0.0138 mA ppm-1 and limit detection of 1.98 ppm. An application of the modified BDD for a biochemical oxygen demand (BOD) sensor using Rhodotorula mucilaginosa UICC Y-181 as the biosensing agent was also demonstrated with glucose solutions as the solution model. Sensitivity equivalent to 17.4 µA mM-1 BOD could be achieved. The system showed good stability with an RSD of 3.45% in 10 measurements.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Boro , Cobre , Técnicas Eletroquímicas , Eletrodos , Ouro , Oxigênio
3.
Anal Sci ; 31(7): 643-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26179128

RESUMO

A gold nanoparticle modified boron-doped diamond electrode was developed as a transducer for biochemical oxygen demand (BOD) measurements. Rhodotorula mucilaginosa UICC Y-181 was immobilized in a sodium alginate matrix, and used as a biosensing agent. Cyclic voltammetry was applied to study the oxygen reduction reaction at the electrode, while amperometry was employed to detect oxygen, which was not consumed by the microorganisms. The optimum waiting time of 25 min was observed using 1-mm thickness of yeast film. A comparison against the system with free yeast cells shows less sensitivity of the current responses with a linear dynamic range (R(2) = 0.99) of from 0.10 mM to 0.90 mM glucose (equivalent to 10 - 90 mg/L BOD) with an estimated limit of detection of 1.90 mg/L BOD. However, a better stability of the current responses could be achieved with an RSD of 3.35%. Moreover, less influence from the presence of copper ions was observed. The results indicate that the yeast-immobilized BOD sensors is more suitable to be applied in a real condition.


Assuntos
Análise da Demanda Biológica de Oxigênio/instrumentação , Técnicas Biossensoriais/instrumentação , Boro/química , Diamante/química , Ouro/química , Rhodotorula/química , Alginatos/química , Eletrodos , Ácido Glucurônico/química , Ácidos Hexurônicos/química , Oxigênio/análise , Oxigênio/química
4.
Phys Chem Chem Phys ; 15(1): 142-7, 2013 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-23147907

RESUMO

Selective anodic stripping voltammetry of trace metal ions in a mixture solution with another interfering metal was developed based on Fick's law concerning the diffusion profile of interfering metals at the electrode surface after electrolysis treatment. A boron-doped diamond film was used as the sensing electrode, while a perforated carbon sheet was used for the interference-depleting electrode. The influence of the electrode distance and the time of electrolysis on the formation of the diffusion profile was studied. As a working model, the detection of cadmium with copper interference was investigated. The advantage of the method in comparison to general electrolysis was also discussed. The method offers a new perspective for improving the selective detection of metal ions by analyzing the diffusion profiles of the interfering species at the surface of electrodes.

5.
Anal Chem ; 84(22): 9825-32, 2012 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-23088708

RESUMO

Gold-modified boron doped diamond (BDD) electrodes were examined for the amperometric detection of oxygen as well as a detector for measuring biochemical oxygen demand (BOD) using Rhodotorula mucilaginosa UICC Y-181. An optimum potential of -0.5 V (vs Ag/AgCl) was applied, and the optimum waiting time was observed to be 20 min. A linear calibration curve for oxygen reduction was achieved with a sensitivity of 1.4 µA mg(-1) L oxygen. Furthermore, a linear calibration curve in the glucose concentration range of 0.1-0.5 mM (equivalent to 10-50 mg L(-1) BOD) was obtained with an estimated detection limit of 4 mg L(-1) BOD. Excellent reproducibility of the BOD sensor was shown with an RSD of 0.9%. Moreover, the BOD sensor showed good tolerance against the presence of copper ions up to a maximum concentration of 0.80 µM (equivalent to 50 ppb). The sensor was applied to BOD measurements of the water from a lake at the University of Indonesia in Jakarta, Indonesia, with results comparable to those made using a standard method for BOD measurement.


Assuntos
Técnicas Biossensoriais/métodos , Boro/química , Diamante/química , Ouro/química , Oxigênio/metabolismo , Técnicas Biossensoriais/instrumentação , Eletroquímica , Eletrodos , Rhodotorula/metabolismo