1.
Rom J Ophthalmol ; 59(3): 177-83, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26978888

RESUMO

PURPOSE: to show how we diagnosed and treated a rarer form of angle-closure glaucoma; the pathogenic mechanism was angle crowding through thick peripheral iris roll. METHODS: we show the investigations: biomicroscopy of the fundus, tonometry, pachymetry, gonioscopy, perimetry, ultrasound biomicroscopy, optical coherence tomography of the anterior segment--that helped us to diagnose the angle-closure glaucoma and its pathogenic mechanism; we also show our choice for surgery--lens extraction--and our arguments for this choice. RESULTS: first postoperative day--intraocular pressure was 14 mmHg; a week postoperatively--intraocular pressure was 13 mmHg; three months postoperatively--intraocular pressure was 13 mmHg. CONCLUSIONS: lens extraction may be a very good choice in several forms of angle-closure glaucoma.


Assuntos
Glaucoma de Ângulo Fechado/diagnóstico , Glaucoma de Ângulo Fechado/cirurgia , Cristalino/cirurgia , Adulto , Paquimetria Corneana/métodos , Feminino , Fundo de Olho , Gonioscopia/métodos , Humanos , Pressão Intraocular , Microscopia Acústica , Doenças Raras , Tomografia de Coerência Óptica , Tonometria Ocular/métodos , Resultado do Tratamento , Testes de Campo Visual/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA