Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
J Ophthalmic Vis Res ; 18(1): 68-80, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36937194

RESUMO

Purpose: This research intended to fabricate the thiolated chitosan-dextran nanoparticles (NPs) containing topotecan (TPH-CMD-TCS-NPs) to assess the ability of NPs in improving the efficacy of intravitreal chemotherapy of retinoblastoma in a rabbit xenograft model. Methods: The coacervation process was used to produce the NPs. The cellular uptake of Cyanine-3 (CY3)-labeled NPs were investigated in human retinoblastoma Y79 cells using confocal microscopy. Also, the prepared TPH-CMD-TCS-NPs were tested in vitro by the tetrazolium dyes II (XTT) and flow cytometry in order to assess their cytotoxicity. In addition, a rabbit xenograft model of retinoblastoma was developed to test the antitumor effectiveness of TPH-CMD-TCS-NPs through intravitreal administration. Results: NPs had a mean diameter, polydispersity index, and zeta potential of 30 ± 4 nm, 0.24 ± 0.03 and +10 ± 3 mV, respectively. NPs (IC50s 40.40 compared to 126.20 nM, P = 0.022) were more effective than free topotecan as a dose-based feature. The tumor reaction to intravitreal chemotherapy with NPs was measured by evaluating the percentage of necrosis in the tumor tissue (91 ± 2%) and vitreous seeds (89 ± 9%) through hematoxylin and eosin (H&E) staining. In comparison with the control group, the TPH-CMD-TCs-NPs treated group showed a significant decrease in tumor volume seven days after the intravitreal injection (P = 0.039). No significant changes were found in the ERG parameters after the intravitreal injection of TPH-CMD-TCs-NPs or TPH (P > 0.05). Conclusion: This investigation revealed definitive antitumor efficacy of TPH-CMD-TCS-NPs by intravitreal administration in the rabbit xenograft retinoblastoma model.

3.
J Curr Ophthalmol ; 34(1): 67-73, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35620361

RESUMO

Purpose: To investigate the accuracy of Okulix ray-tracing software in calculating intraocular lens (IOL) power in the long cataractous eyes and comparing the results with those obtained from Kane, Holladay 1 with optimized constant, SRK/T with optimized constant, Haigis with optimized constant, and Barret Universal 2 formulas. Methods: The present study evaluates the refractive results of cataract surgery in 85 eyes with axial length > 25 mm and no history of ocular surgery and corneal pathology. IOL power calculation was performed using the Okulix software. The performances of Okulix software in comparison with the five other formulas were evaluated by predicted error, mean absolute error, and mean numerical error 6 months after surgery. Results: The mean calculated IOL power by the Okulix software was +13.48 ± 4.19 diopter (D). The mean of the 6-month postoperative sphere and spherical equivalent were +0.18 ± 0.63 and -0.34 ± 0.78 D, respectively. Also, the 6-month spherical equivalent in 56.6% and 80% of eyes were within ±0.05 and ±1.00 D, respectively. The predicted error (P < 0.001) and the mean numerical error (P < 0.001) were different between the six studied methods; however, we were not able to find any significant differences in the mean absolute error among six studied methods (P: 0.211). Conclusion: The present study showed acceptable performance of the Okulix software in IOL power calculation in long eyes in comparison with the other five methods based on the postoperative refractive error, calculated mean absolute error, and mean numerical error.

4.
Eur J Ophthalmol ; 32(6): 3312-3320, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35175136

RESUMO

PURPOSE: To evaluate the refractive outcomes of small-incision lenticule extraction (SMILE) surgery in moderate to high myopic astigmatism. STUDY DESIGN: Prospective interventional case series. METHODS: This study evaluated 111 eyes of 68 patients treated with femtosecond SMILE surgery for the correction of myopia and astigmatism. Inclusion criteria were myopia of - 0.5 D or more and astigmatism between - 1.0 D and -5.0 D. Refractive and visual measurements were obtained preoperatively, 1 and 12 month(s) postoperatively. Vector analysis was used to study the astigmatic outcomes at 12-month follow-up. Comparison of results in two groups of patients with astigmatism below and over 3.00 D was performed. RESULTS: The preoperative mean spherical equivalent was -5.48 ± 2.17 D (range - 1.75 to - 10.00 D) and the mean cylinder was -2.02 ± 1.09 D (range - 1.00 to - 5.00 D). The mean postoperative cylinder value was -0.60 ± 0.52 D at 12-month visit. The 12-month safety and efficacy indices were 0.98 ± 0.07 and 0.97 ± 0.12, respectively. The high astigmatism group showed significantly lower safety and efficacy indices. The postoperative residual astigmatism was 0.5 D or less in 73% of the eyes. Higher amount of residual astigmatism was observed in the high astigmatism group. The angle of error was ± 5 degrees in 49% and ± 15 degrees in 87% of the eyes. CONCLUSION: SMILE surgery is effective and safe method for correcting myopic astigmatism. Vector analysis indicated a tendency for the under correction of astigmatism in subjects with high astigmatism.


Assuntos
Astigmatismo , Miopia , Ferida Cirúrgica , Astigmatismo/cirurgia , Substância Própria/cirurgia , Seguimentos , Humanos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Estudos Prospectivos , Refração Ocular , Resultado do Tratamento , Acuidade Visual
5.
J Ophthalmic Vis Res ; 17(1): 58-68, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35194497

RESUMO

PURPOSE: The use of more potent medicine for local chemotherapy of retinoblastoma in order to minimize local and systemic adverse effects is essential. The main goal of this investigation was to assess the biodistribution of thiolated and methylated chitosan-carboxymethyl dextran nanoparticles (CMD-TCs-NPs and CMD-TMC-NPs) following intravitreal (IVT) injection into rat eyes with retinoblastoma. METHODS: An ionic gelation method was used to fabricate Cy5-labelled CMD-TCs-NPs and CMD-TMC-NPs. The NPs were characterized. Cellular internalization of Cy5-labelled NPs was investigated using confocal microscopy and the absorption of labeled NPs was quantified by flow cytometry in human retinoblastoma (Y79) cells. In addition, the Cy5-labeled distribution of nanoparticles in the posterior segment of the eye was histologically imaged by confocal microscopy after IVT injection of NPs into the eyes of rats with retinoblastoma. RESULTS: CMD-TCs-NPs and CMD-TMC-NPs showed a mean diameter of 34 ± 3.78 nm and 42 ± 4.23 nm and zeta potential of +11 ± 2.27 mV and +29 ± 4.31mV, respectively. The in vivo study of intraocular biodistribution of Cy5-labeled CMD-TCs-NPs and CMD-TMC-NPs revealed that there is more affinity of CMD-TCs-NPs to the retina and retinoblastoma tumor after IVT administration while methylated chitosan nanoparticles are immobilized in the vitreous and are not able to reach the retina even after 24 hr. CONCLUSION: The ionic gelation technique was efficient in synthesizing a biocompatible polymeric nanosystem for drug delivery into the posterior segment of the eye. The current study demonstrated increased ocular bioavailability of CMD-TCs-NPs relative to CMD-TMC-NPs in retinoblastoma induced rat eyes.

6.
Cornea ; 41(4): 435-442, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34267059

RESUMO

PURPOSE: The purpose of this study was to evaluate the efficacy and safety of implantation of a new continuous corneal ring in keratoconic corneas of an Iranian population. METHODS: This study was conducted on 95 contact lens-intolerant keratoconic eyes with clear central corneas. A continuous corneal ring, annular intrastromal corneal inlay (AICI), was inserted using femtosecond laser in all cases. Patients were followed up for 1, 3, and 12 months postsurgery. Visual and subjective refractive outcomes were evaluated in each examination. Besides, keratometry and aberrometric values were recorded before and 12 months after surgery. Finally, vector analysis of refractive astigmatism was performed using the Alpins method. RESULTS: The uncorrected and corrected distance visual acuities improved significantly 12 months after surgery from 0.91 ± 0.39 to 0.38 ± 0.22 (P < 0 0.001) and 0.33 ± 0.21 to 0.13 ± 0.11 logMAR (P < 0.001), respectively. Moreover, spherical and cylindrical refractive components reduced from -2.52 ± 2.62 to -0.76 ± 1.78 D (P < 0.001) and -4.14 ± 1.64 to -1.91 ± 1.18 D (P < 0.001), respectively. The mean anterior keratometry had a significant reduction 12 months after AICI insertion (P< 0.001). Primary coma and spherical aberration values showed a significant increase (both, P < 0.05). Our results showed 100% safety (safety index: 1.8) and 45% efficacy (efficacy index: 1). CONCLUSIONS: AICI implantation seemed to be a safe and effective procedure for improving visual acuity and refractive outcomes in subjects with keratoconus.


Assuntos
Substância Própria/cirurgia , Ceratocone/cirurgia , Próteses e Implantes , Implantação de Prótese/métodos , Aberrometria , Adulto , Topografia da Córnea , Aberrações de Frente de Onda da Córnea/fisiopatologia , Feminino , Seguimentos , Humanos , Irã (Geográfico) , Ceratocone/fisiopatologia , Masculino , Desenho de Prótese , Refração Ocular/fisiologia , Resultado do Tratamento , Acuidade Visual/fisiologia
7.
J Curr Ophthalmol ; 33(1): 23-30, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34084953

RESUMO

PURPOSE: To investigate the changes in the optical corneal densitometry as an objective method in assessing the corneal light back-scattering before and 1 year after the annular intracorneal inlay (AICI) implantation into the keratoconic corneas. METHODS: Changes in the optical corneal densitometry, visual acuity, refractive, and tomographical status were assessed before and 1 year after the AICI implantation into the corneas with different stages of keratoconus. Optical corneal densitometry was evaluated using the Pentacam-HR in 0-2, 2-6, 6-10, and 10-12 mm rings in the anterior 120 µ, central layers, posterior 60 µ and also the total value were measured for cornea in the Grey Scale Unit criterion. RESULTS: Totally, 34 patients with keratoconus were studied; the uncorrected and best corrected visual acuity were increased after the surgery (0.98 ± 0.25 to 0.53 ± 0.30 logMAR, P < 0.001 and 0.26 ± 0.18 to 0.19 ± 0.14, P = 0.007 logMAR, respectively); the spherical equivalent was decreased from -4.45 ± 2.25 to - 2.06 ± 2.01 D (P = 0.004). AICI implantation led to an increase in the amount of optical corneal densitometry in 0-2 mm central, 2-6 mm central, 6-10 mm central, total central, 2-6 mm posterior, and 2-6 mm total rings (all, P < 0.05); however, a decrease was observed in 0-2 mm anterior ring (P = 0.049). Results of statistical analysis showed that the total optical corneal densitometry, anterior total, and posterior total back-scattering did not change after the AICI implantation (all, P > 0.05). CONCLUSIONS: Our results revealed a significant improvement in the visual function, including refractive error and visual acuity following the AICI implantation. Changes in the optical corneal densitometry were different in distinct regions and layers however, the total amount did not change after the AICI implantation.

8.
Exp Eye Res ; 204: 108423, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33453276

RESUMO

Retinoblastoma (Rb) is the most common intraocular malignancy in children that accounts for approximately 4% of all pediatric malignancies. Since chemotherapy is a widely practiced treatment for Rb, there is a growing interest in developing new and effective drugs to overcome systemic and local side effects of chemotherapy to improve the quality of life and increase the chances of survival. This study sought to fabricate thiolated chitosan nanoparticles containing topotecan (TPH-TCs-NPs) with a view of enhancing drug loading and release control. This research was also designed to assess the ability of TPH-TCs-NPs to improve cell association, increase treatment efficacy in retinoblastoma cells and xenograft-rat-model of retinoblastoma, and overcome current topotecan hydrochloride (TPH) intravitreal administration challenges, including stability loss and poor cellular uptake. Modified ionic gelation method was optimized to fabricate TPH-TCs-NPs and TPH-TMC-NPs (N-trimethyl chitosan nanoparticles containing TPH). We characterized the NPs and quantified topotecan loading and release against a free TPH standard. The efficacy of TPH-NPs was quantified in human retinoblastoma cells (Y79) by XTT and flow cytometry measurement. In addition, Y79 cells were injected intravitreally in both eyes of immunodeficient wistar albino rats to create a xenograft-rat-model to compare the antitumor effectiveness of TPH-NPs and TPH by intravitreal administration. TPH-NPs complexation was confirmed by EDX, FTIR, and DSC techniques. TPH-TCs-NPs and TPH-TMC-NPs had high encapsulation efficiency (85.23 ± 2 and 73.34 ± 2% respectively). TPH-TCs-NPs showed a mean diameter, polidispersity index, and zeta potential of 25±2 nm, 0.21 ± 0.03 and +12 ± 2 mV, respectively. As a function of dose, TCs and TMC NPs were more efficacious than free topotecan (IC50s 53.17 and 85.88 nM, relative to 138.30 nM respectively, P = 0.012). Kruskal-Wallis test showed a statistically significant difference between the groups. Additionally, a significant difference between the tumor control and TPH-TCs-NPs treated group in xenograft-rat-model ( Range of P-value: 0.026 to 0.035) was shown by Bonferroni post hoc test. The current investigation demonstrated enhanced efficacy and association of TPH-TCs-NPs relative to free TPH in retinoblastoma cells and tumor in vitro and in vivo.


Assuntos
Antineoplásicos/administração & dosagem , Quitosana/administração & dosagem , Portadores de Fármacos , Neoplasias da Retina/tratamento farmacológico , Retinoblastoma/tratamento farmacológico , Inibidores da Topoisomerase I/administração & dosagem , Topotecan/administração & dosagem , Animais , Varredura Diferencial de Calorimetria , Quitosana/química , Citometria de Fluxo , Humanos , Injeções Intravítreas , Masculino , Nanopartículas , Transplante de Neoplasias , Tamanho da Partícula , Ratos , Ratos Wistar , Neoplasias da Retina/patologia , Retinoblastoma/patologia , Espectrometria por Raios X , Espectroscopia de Infravermelho com Transformada de Fourier , Transplante Heterólogo , Resultado do Tratamento , Células Tumorais Cultivadas , Difração de Raios X
9.
Eur J Ophthalmol ; 31(4): 1577-1583, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32715752

RESUMO

PURPOSE: A 6-month evaluation of the topographic and biomechanical changes induced by corneal collagen cross-linking (CXL) in keratoconic eyes using Pentacam and Corvis ST. DESIGN: Longitudinal prospective case series. METHODS: In this study, 67 eyes of 67 patients with progressive keratoconus (KCN) treated with "Epithelium-off" CXL were evaluated. Patients with stages 1 or 2 of KCN and a corneal thickness of at least 400 µm at the thinnest point were included. Standard ophthalmologic examinations were carried out for all patients. The topographic and biomechanical measurements of the cornea were obtained by Pentacam (Oculus Optikgeräte GmbH, Wetzlar, Germany) and Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany) preoperatively and 6-month postoperatively. RESULTS: The mean age of the participants was 21.68 ± 4.23 years. There was significant difference in mean spherical equivalent (SE) before and 6 months after CXL. Uncorrected and best corrected visual acuity improved postoperatively, although not statistically significant. The mean and maximum keratometry showed a significant decrease 6 months after CXL (0.93 ± 0.38 D and 1.43 ± 0.62 D, respectively p < 0.001). Among Corvis ST parameters, first applanation length and velocity (AL1 and AV1) showed statistically significant changes. The radius at highest concavity changed significantly (0.13 ± 0.37 mm mean increase after CXL; p < 0.001). A significant increase was observed in stiffness parameter A1 (SP-A1; p < 0.001) and significant decreases were noted in integrated radius (IR) and deformation amplitude ratio (DAR; p < 0.001). CONCLUSION: Analyzing biomechanical changes after corneal cross-linking can provide basis for efficient KCN treatment. Corvis ST parameters demonstrated changes in corneal biomechanical characteristics indicative of stiffing after CXL.


Assuntos
Córnea , Ceratocone , Colágeno , Topografia da Córnea , Reagentes de Ligações Cruzadas , Humanos , Ceratocone/tratamento farmacológico , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Prospectivos , Riboflavina/uso terapêutico
10.
J Refract Surg ; 36(12): 786-794, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33295990

RESUMO

PURPOSE: To investigate the potential benefit of keratoconus surgery using customized corneal stromal donor lenticules obtained from myopic small incision lenticule extraction (SMILE) surgery by femtosecond laser. METHODS: In this prospective, consecutive, non-comparative series of cases, 22 lenticules were obtained from 22 myopic patients who had SMILE with a lenticule central thickness of greater than 110 µm. The lenticules were implanted in 22 eyes with advanced keratoconus. The lenticules were customized for the purpose of the implantation with either a simple necklace or necklace-with-ring shape (compound form) depending on the corneal thickness and corneal topography configuration of the implanted keratoconic eyes. The lenticules were implanted into a 9.5-mm corneal lamellar pocket created by the femtosecond laser. Changes in densitometry, thickness, confocal microscopy, corrected distance visual acuity (CDVA), and endothelial cell density were investigated. RESULTS: Intrastromal lenticule implantation was successfully performed in all cases without any complication. Corneal thickness showed a mean enhancement of 100.4 µm at the thinnest point. On biomicroscopy, all corneas were clear at 1 year postoperatively and there was a significant improvement in corneal densitometry during the entire follow-up period. Confocal biomicroscopy showed collagen reactivation without any inflammatory features caused by the implanted fresh lenticules. CDVA improved from 0.70 to 0.49 logMAR (P = .001) and keratometry decreased from 54.68 ± 2.77 to 51.95 ± 2.21 diopters (P = .006). CONCLUSIONS: Customized SMILE lenticule implantation by femtosecond laser proved to be feasible, resulting in an improvement in vision, topography, and refraction in the implanted eyes. [J Refract Surg. 2020;36(12):786-794.].


Assuntos
Cirurgia da Córnea a Laser , Ceratocone , Substância Própria , Topografia da Córnea , Humanos , Ceratocone/cirurgia , Estudos Prospectivos , Refração Ocular , Tomografia de Coerência Óptica
11.
Cornea ; 39(9): 1184-1189, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32558727

RESUMO

PURPOSE: To evaluate the safety and efficacy of a bioengineered corneal implant using femtosecond laser-assisted anterior lamellar keratoplasty for superficial corneal opacities. METHODS: Six eyes of 6 consecutive patients with superficial corneal stromal opacities involving <220 µm owing to various pathologies were included in the study. Preoperatively, all patients underwent anterior segment optical coherence tomography (Visante; Carl Zeiss Meditec AG) to evaluate the depth of the corneal opacity. All patients underwent sutureless femtosecond laser-assisted anterior lamellar keratoplasty using a bioengineered collagen corneal implant (linkcor). Visual indices, refraction, and keratometry were evaluated preoperatively and 12 months postoperatively. RESULTS: Corrected distance visual acuity improved significantly in all patients (P = 0.02). A significant decrease was seen in refractive astigmatism postoperatively (P = 0.04). Flat keratometry reduced significantly 12 months after the intervention (P = 0.04). No intraoperative or early postoperative complications were noticed. All implants were fully covered by healthy epithelium within a month after the surgery and remained clear at follow-up visits. The results of this procedure remained stable throughout the follow-up period. In 1 patient, mild inferior collagen melting and epithelial defect formation occurred at 1-year follow-up. Despite frequent topical corticosteroid therapy the melting progressed, the collagen tissue was removed and the patient was treated accordingly with good visual outcomes. CONCLUSIONS: Femtosecond laser-assisted anterior lamellar keratoplasty with bioengineered corneal (linkcor) implantation is an effective treatment for improving vision quality in anterior stromal opacities. This procedure reduces the need for human donor tissue and avoids human donor-related and suturing complications.


Assuntos
Bioengenharia/métodos , Opacidade da Córnea/cirurgia , Substância Própria/cirurgia , Transplante de Córnea/métodos , Terapia a Laser/métodos , Refração Ocular/fisiologia , Procedimentos Cirúrgicos sem Sutura/métodos , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Doadores de Tecidos , Acuidade Visual
12.
J Cataract Refract Surg ; 46(8): 1159-1164, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32355080

RESUMO

PURPOSE: To investigate the change in anterior, posterior, and net corneal power more than 18 months after photorefractive keratectomy (PRK) by RTVue anterior segment optical coherence tomography (OCT). SETTING: Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran. DESIGN: Prospective observational study. METHODS: PRK was performed using Technolas TENEO 317 laser platform. Anterior, posterior, and net corneal power was measured by the RTVue-XR anterior segment OCT system with the Pachymetry + Cpwr scan pattern at baseline and months 1, 3, 6, 12, 18, and more than 18 (up to 27) after PRK. RESULTS: Three hundred twenty-six eyes of 163 patients (61 men [37.4%], 102 women [62.6%]; mean age 29.71 years; range 18.5 to 46.5 years) were enrolled in this study. Mean preoperative spherical equivalent was -3.15 ± 1.50 diopter (D) (range -8.37 to -0.62 D). The mean change in net corneal power was 3.052 D, 3.281 D, 3.324 D, 3.114 D, 3.446 D, and 3.972 D at months 1, 3, 6, 12, 18, and more than 18 postoperatively compared with baseline, respectively (P < .001 for all comparisons). The mean change in posterior corneal power at postoperative visits compared with baseline was not statistically significant (P > .1) except for 1 month postoperatively, which increased by 0.13 D (P < .001). Changes in posterior corneal power were not correlated with any of the preoperative clinical and Scheimpflug variables. CONCLUSIONS: Posterior corneal power did not change for more than 18 months after PRK, except for an early small increase at 1 month postoperatively.


Assuntos
Miopia , Ceratectomia Fotorrefrativa , Adolescente , Adulto , Córnea/diagnóstico por imagem , Topografia da Córnea , Feminino , Humanos , Irã (Geográfico) , Lasers de Excimer/uso terapêutico , Masculino , Pessoa de Meia-Idade , Miopia/cirurgia , Refração Ocular , Tomografia de Coerência Óptica , Adulto Jovem
13.
Ophthalmology ; 127(4): 557, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32200842

RESUMO

This article has been retracted: please see Elsevier policy on Article Withdrawal (https://www.elsevier.com/about/our-business/policies/article-withdrawal). The editors wish to note that concerns were raised regarding coding errors in the data set that formed the basis of this study. Patient record numbers were found to be duplicated, so that the number of endophthalmitis cases was unclear as was the associated treatment, and the number of unique patients estimated to be far less than the 480,000 reported. Upon review of the information provided, Ophthalmology has determined the dataset to be flawed with unverifiable elements from which reliable conclusions cannot be drawn, and therefore has made the decision to issue a retraction of the manuscript.

14.
East Mediterr Health J ; 24(7): 664-671, 2018 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-30215476

RESUMO

BACKGROUND: Cataract surgery is a highly cost-effective intervention for sight restoration but inequalities exist in its use which health care systems should aim to reduce. AIMS: This study aimed to measure the level of inequality in cataract surgery use and the changes in inequality between 2006 and 2011 in the Islamic Republic of Iran. METHODS: A number of metrics, including ranges and indexes based on Lorenz curves (Gini, concentration and dissimilarity indexes), were used to measure the inequality in cataract surgery use among Iranians in 2006 and 2011. Cataract surgical numbers and socioeconomic data were obtained from a province-based survey and the national census database. RESULTS: Significant inter-provincial and inter-regional differences were found in cataract surgical proportions. South Khorasan province had the lowest cataract surgical rate in 2006 and 2011, while Tehran province had the highest rate in both years. Inequality in the distribution of cataract surgery services decreased between 2006 and 2011: the Gini, concentration and dissimilarity indexes decreased by 0.028, 0.03 and 0.037, respectively. However, cataract surgery delivery remained in favour of the better-off provinces. CONCLUSIONS: To reduce this inequality, policy-makers should improve financial and physical access to cataract surgery, especially in the relatively deprived provinces, and tackle physician-induced demand.


Assuntos
Extração de Catarata/estatística & dados numéricos , Disparidades em Assistência à Saúde , Disparidades em Assistência à Saúde/economia , Disparidades em Assistência à Saúde/estatística & dados numéricos , Humanos , Irã (Geográfico) , Fatores Socioeconômicos , Inquéritos e Questionários
15.
J Curr Ophthalmol ; 29(4): 287-292, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29270476

RESUMO

PURPOSE: To investigate the effects of religious fasting during the month of Ramadan on intraocular pressure (IOP), refractive error, corneal tomography and biomechanics, ocular biometry, and tear film layer properties. METHODS: This prospective study was carried out one week before and in the last week of Ramadan. Ninety-four eyes of 94 healthy adult volunteers (54 males and 40 females) with a mean ± SD age of 35.12 ± 9.07 were enrolled in this study. Patients with any systemic disorder, ocular disease, or a history of previous surgery were excluded. Corneal tomography and biomechanics, ocular biometry, IOP, refractive error, and tear break up time (TBUT) were evaluated in non-fasting and fasting periods by the Pentacam (Oculus), Corvis ST (Oculus), IOL Master (Carl Zeiss), computerized tonometer (Topcon CT-1/CT-1P), auto kerato-refractometer (Topcon KR-1), and Keratograph 5M (Oculus), respectively. RESULTS: There was no significant difference in the central corneal thickness (CCT) between the study groups (P = 0.123) using the Pentacam while the Corvis ST showed a significant difference in all participants (P < 0.0001). Moreover, the peak distance (distance of the two surrounding peaks of the cornea at the highest concavity) of male and female participants showed a significant difference between the fasting and non-fasting groups (P = 0.002). The anterior chamber depth (ACD) using the Pentacam decreased in the male group (P = 0.004) in the fasting period. During the fasting period, computerized tonometer showed a decrease in IOP only in males in comparison to the non-fasting group (P = 0.018) while the Corvis ST showed decreased IOP in all participants (P < 0.0001). The steep keratometry (K2) in the corneal posterior surface appeared to be different in males between the study groups (P = 0.034). We were unable to show any significant difference in other ocular parameters between fasting and non-fasting periods. CONCLUSION: This study showed that ACD, IOP, CCT, and peak distance were different between fasting and non-fasting groups while no difference was observed in other ocular parameters. Interpretations of these significant differences should be considered in the clinical setting.

16.
Medicine (Baltimore) ; 96(45): e8405, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29137026

RESUMO

PURPOSE: To evaluate probable complications of ArtificialIris implantation with iris fixated intraocular lens. METHOD: Development of photophobia, glare, and psychological strain during face-to-face communication in a 23-year-old man with a widespread traumatic iris defect terminate to make a decision for performing implantation of an ArtificialIris (Humanoptics, Erlangen, Germany) under the remnant iris without removing the patient's existing Artisan lens. RESULTS: Without any intraoperative or postoperative complications, the patient's visual acuity increased by 1 line, the endothelial cell loss was comparable with the cell loss associated with standard cataract surgery, and the anterior-chamber depth and anterior-chamber anatomy did not change. At the final follow-up examination, the mean intraocular pressure did not differ from baseline, and we achieved high level of patient satisfaction and subjective vision improvement. We discuss the particular importance of considering the patient's expectations, the appropriate measurements, ways to perfect color evaluation, and the types of ArtificialIris products. CONCLUSION: The implantation of the ArtificialIris in patients with aphakic iris-supported lenses (ie, pre-existing Artisan lenses) is a feasible approach and a useful option for patients with thin irises and iris hypoplasia who are at risk of subluxation or the dislocation of the posterior-chamber intraocular lens (PCIOL), and also those with sclerally fixed PCIOLs.


Assuntos
Ferimentos Oculares Penetrantes/cirurgia , Olho Artificial , Olho , Humanos , Pressão Intraocular , Masculino , Acuidade Visual , Adulto Jovem
17.
J Ophthalmic Vis Res ; 12(4): 374-379, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29090045

RESUMO

PURPOSE: The aim of this study was to determine the agreement between Pentacam HR (Scheimpflug imaging, Oculus) and Orbscan II (scanning slit topography, Bausch and Lomb) in measuring corneal parameters after photorefractive keratectomy (PRK) for hyperopia. METHODS: In this prospective cross-sectional study, 38 hyperopic eyes undergoing PRK were examined before refractive surgery and 8 to 10 months postoperatively using Pentacam HR and Orbscan II. Ultrasound (US) pachymetry was also used to measure central corneal thickness (CCT). The radius of anterior (A-) and posterior (P-) best-fit sphere size (BFS), central elevation (CE), and anterior maximum tangential power in 3 mm (TG3) and 3-5 mm (TG5) zones, anterior chamber depth (ACD), and central corneal thickness (CCT) were collected and used in the analyses. To study the agreement between the measurements made by the two devices, the method described by Bland and Altman was used and the 95% limits of agreement were calculated. RESULTS: The 95% limits of agreement show reasonable agreement between the measurements by Pentacam HR and Orbscan II for A-BFS, P-BFS, A-TG3, and CCT, but not for A-CE, P-CE, A-TG5, or ACD. CCT values obtained by both Pentacam HR and Orbscan II correlated well with the values determined by US pachymetry. CONCLUSION: Pentacam HR and Orbscan II after PRK for hyperopia show reasonable agreement for determining A-BFS, P-BFS, A-TG3, and CCT, but not for A-CE, P-CE, A-TG5, or ACD. CCT measurements with Pentacam HR have reasonable agreement with US pachymetry.

18.
J Res Med Sci ; 22: 17, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28458708

RESUMO

BACKGROUND: Astigmatism is the leading complication in visual recovery after penetrating keratoplasty (PKP) and deep anterior lamellar keratoplasty (DALK); in this study, we evaluated the outcome of femtosecond laser arcuate keratotomy (FLAK) after DALK and PKP in Iranian keratoconic patients. MATERIALS AND METHODS: In this prospective interventional case series, refractive and keratometric predictability, efficacy, and complications of FLAK for postkeratoplasty astigmatism in keratoconus were evaluated; 23 eyes of 23 consecutive patients (mean age of 32.43 ± 9.11 years) with high astigmatism were enrolled. The femtosecond laser performed paired 90°-angled arcuate incisions. RESULTS: Mean logarithm of the minimum angle of resolution of corrected and uncorrected visual acuity improved from preoperative values of 0.30 ± 0.18 and 0.85 ± 0.32 to 6-month values of 0.19 ± 0.17 and 0.65 ± 0.33, respectively (P < 0.05). Mean subjective astigmatism was 7.79 ± 2.64 diopter (D) preoperatively and 3.69 ± 2.25D at 6-month after surgery (P < 0.05). Surgically induced astigmatism was 9.27 ± 5.00D. Mean refractive spherical equivalent showed no significant (P = 0.69) hyperopic shift from - 4.21 ± 4.84D preoperatively to - 2.16 ± 6.09D postoperatively. Two (8.7%) microperforations were observed. CONCLUSION: FLAK is a relatively safe and effective method for the treatment of postkeratoplasty astigmatism.

19.
J Ophthalmic Vis Res ; 11(4): 345-349, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27994801

RESUMO

PURPOSE: To evaluate the histopathologic changes in the conjunctiva of patients with conjunctivochalasis (CCh) compared to age-matched controls. METHODS: This cross-sectional, controlled study included 27 eyes of 27 patients with CCh and 16 eyes of 16 age-matched controls. A biopsy of the bulbar conjunctiva was performed along the temporal lower lid margin before cataract surgery in both groups. Histopathologic evaluation of the specimens was done with light microscopy using staining with hematoxylin/eosin, periodic acid Schiff, and van Gieson elastic stain. Various histopathologic features of the conjunctival epithelium and stroma were compared between the two groups. RESULTS: The mean age of patients was 62.4 ± 6.9 years in the CCh group and 65.1 ± 6.3 years in the control group (P = 0.54). No significant differences were noted between the two groups in terms of conjunctival epithelial changes including papillomatosis, epithelial clefts, epithelial goblet cells, or infiltration of inflammatory cells. Mean thickness of the conjunctival stroma was 0.21 ± 0.08 mm in the CCh group and 0.26 ± 0.21 mm in the control group (P = 0.10). For the conjunctival stroma, there were no significant differences between the two groups in terms of elastosis, fibrosis, lymphangiectasia, or infiltration of inflammatory cells. CONCLUSION: No noticeable differences were found in the histopathologic features by light microscopy between eyes with CCh and those of age-matched controls. Therefore, the primary pathology of CCh may not be within the conjunctiva itself. Instead, loose attachment of the conjunctiva to the underlying tissue may be the reason for the redundant folds in the bulbar conjunctiva.

20.
J Curr Ophthalmol ; 28(3): 101-5, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27579452

RESUMO

PURPOSE: To investigate recent evidence in prophylaxis and management of post-cataract surgery endophthalmitis. METHODS: We conducted a literature search using Pubmed database for post cataract surgery endophthalmitis, and relevant articles were selected from original English papers published since 2015. RESULTS: Forty-nine articles were published regarding post-cataract surgery endophthalmitis from January 2015 to February 2016. A low incidence of post-cataract surgery endophthalmitis has been reported. A growing number of articles are focusing on preventing endophthalmitis using intracameral antibiotics. CONCLUSION: Based on the current evidence, intracameral antibiotics seems to be effective in preventing endophthalmitis after cataract surgery.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA