Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Medicina (Kaunas) ; 60(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38792942

RESUMO

Heart failure (HF) remains a major medical and social problem. The NT-pro-brain natriuretic peptide (NT-proBNP) and its active form, brain-type natriuretic peptide (BNP), in a simple blood test are the gold-standard biomarkers for HF diagnosis. However, even good biomarkers such as natriuretic peptides fail to predict all the risks associated with HF due to the diversity of the mechanisms involved. The pathophysiology of HF is determined by numerous factors, including oxidative stress, inflammation, neuroendocrine activation, pathological angiogenesis, changes in apoptotic pathways, fibrosis and vascular remodeling. High readmission and mortality rates prompt a search for new markers for the diagnosis, prognosis and treatment of HF. Oxidative-stress-mediated inflammation plays a crucial role in the development of subsequent changes in the failing heart and provides a new insight into this complex mechanism. Oxidative stress and inflammatory biomarkers appear to be a promising diagnostic and prognostic tool in patients with HF. This systematic review provides an overview of the current knowledge about oxidative stress and inflammation parameters as markers of HF.


Assuntos
Biomarcadores , Insuficiência Cardíaca , Inflamação , Estresse Oxidativo , Humanos , Estresse Oxidativo/fisiologia , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/fisiopatologia , Inflamação/sangue , Biomarcadores/sangue , Biomarcadores/análise , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Prognóstico
2.
Kardiol Pol ; 81(3): 242-251, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36446069

RESUMO

BACKGROUND: Transvenous lead extraction (TLE) procedures are now increasingly safe, but there is still a risk of major complications (MC). AIMS: We aimed to assess the impact of TLE organization on the safety of procedures. METHODS: We analyzed 2216 TLE procedures performed in two centers in the years 2006-2021 and compared three organizational procedural models: (1) TLE in an electrophysiology laboratory (EP-LAB) with intravenous analgesia/sedation; (2) TLE with grading of safety requirements (high-risk patients in the cardiac surgery operating theatre, others in EP-LAB); (3) TLE in the hybrid room in all patients under general anesthesia with transesophageal echocardiographic (TEE) monitoring. The safety of procedures and mortality after TLE in three-year follow-up were assessed. RESULTS: The rate of MC in the EP-LAB group was 1.55%, and the rate of procedure-related deaths (PRD) was 0.33%. While using the graded approach to safety requirements, the percentage of MC was 2.61% and PRD 0.29%. When performing TLE procedures in the hybrid room, the MC percentage was 1.33% and PRD 0.00%. Long-term survival after TLE was comparable in all study groups. CONCLUSIONS: A key factor in preventing TLE-related deaths is procedure organization that enables emergency cardiac surgery. TLE performed in a hybrid room with a collaborating cardiac surgeon and vital signs monitoring appears to be the safest possible option for the patient. A graded safety approach is associated with the risk of unexpected MC and PRD. Any newly established TLE center can achieve satisfactory results if the optimal organizational model of the procedure is used.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Remoção de Dispositivo/efeitos adversos , Coração , Marca-Passo Artificial/efeitos adversos
3.
BMJ Open ; 12(12): e062952, 2022 12 29.
Artigo em Inglês | MEDLINE | ID: mdl-36581437

RESUMO

OBJECTIVES: To estimate the impact of the organisational model of transvenous lead extraction (TLE) on effectiveness and safety of procedures. DESIGN: Post hoc analysis of patient data entered prospectively into a computer database. SETTING: Data of all patients undergoing TLE in three centres in Poland between 2006 and 2021 were analysed. PARTICIPANTS: 3462 patients including: 985 patients undergoing TLE in a hybrid room (HR), with cardiac surgeon (CS) as co-operator, under general anaesthesia (GA), with arterial line (AL) and with transoesophageal echocardiography (TEE) monitoring (group 1), 68 patients-TLE in HR with CS, under GA, without TEE (group 2), 406 patients-TLE in operating theatre (OT) using 'arm-C' X-ray machine with CS under GA and with TEE (group 3), 154 patients-TLE in OT with CS under GA, without TEE (group 4), 113 patients-TLE in OT with anaesthesia team, using the 'arm-C' X-ray machine, without CS (group 5), 122 patients-TLE in electrophysiology lab (EPL), with CS under intravenous analgesia without TEE and AL (group 6), 1614 patients-TLE in EPL, without CS, under intravenous analgesia without TEE and AL (group 7). KEY OUTCOME MEASURE: Effectiveness and safety of TLE depending on organisational model. RESULTS: The rate of major complications (MC) was higher in OT/HR than in EPL (2.66% vs 1.38%), but all MCs were treated successfully and there was no MC-related death. The use of TEE during TLE increased probability of complete procedural succemss achieving about 1.5 times (OR=1.482; p<0.034) and were connected with reduction of minor complications occurrence (OR=0.751; p=0.046). CONCLUSIONS: The most important condition to avoid death due to MC is close co-operation with cardiac surgery team, which permits for urgent rescue cardiac surgery. Continuous TEE monitoring plays predominant role in immediate decision on rescue sternotomy and improves the effectiveness of procedure.


Assuntos
Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Modelos Organizacionais , Resultado do Tratamento , Polônia , Remoção de Dispositivo/métodos , Estudos Retrospectivos
4.
Biomedicines ; 10(11)2022 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-36428528

RESUMO

Background. We sought to measure the levels of adipokines, TNF-α and soluble receptors (sTNFr1, sTNFr2) in heart failure patients with reduced ejection fraction (HFrEF) due to non-ischemic cardiomyopathy (nDCM). Methods. A total of 123 patients with HFrEF due to nDCM were divided into three groups according to BMI: 34 (27.6%) normal weight, 56 (45.5%) overweight and 33 (26.8%) obese. A six-minute walk test, echocardiography and right heart catheterization were performed. Serum concentrations of adiponectin, leptin, NT-proBNP, blood hemoglobin, sodium, creatinine, ALAT, AspAT, bilirubin, CRP, lipids, TNF-α, sTNFr1 and sTNFr2 receptors were measured. Results. Obese patients had the lowest NT-proBNP concentrations, significantly higher leptin levels and higher leptin/adiponectin ratios. The concentration of sTNFr1 was higher in normal-weight patients. In all groups, TNF-α concentrations correlated positively with sTNFr1 (p < 0.001). Higher levels of sTNFr1 were associated with higher sTNFr2 (p < 0.001) and CRP (p < 0.001). Moreover, the concentration of sTNFr2 positively correlated with CRP (p < 0.05) and adiponectin (p < 0.001). Levels of TNF-α were not associated with elevated CRP. Conclusion: This study demonstrated that changes in the concentrations of TNF and its receptors differ between groups of patients with different BMI. These findings suggest that the effective use of anti-TNF therapy is dependent not only on BMI, but also on concentrations of TNF-α receptors and other laboratory parameters.

5.
Artigo em Inglês | MEDLINE | ID: mdl-36361063

RESUMO

BACKGROUND: There is limited knowledge on outcome of transvenous lead extraction (TLE) of leads being 20 and 30 years old. METHODS: Retrospective single center large database analysis containing 3673 TLE procedures performed from 2006 to 2020 was analysed. We aimed to compare procedure complexity and the incidence of the TLE major complications (MC) in groups where extracted leads were under 10 years, 10-20 years, 20-30 years (old) and over 30 years (very old). RESULTS: Rate of removal of old and very old leads almost doubles with successive five-year periods (3-6-10%). In patients with old and very old leads there is an accumulation of risk factors for major complications of TLE (young age, female, multiple and/or abandoned leads, multiple previous procedures). The removal of old and very old leads was more labour-consuming, more difficult, and much more often required second-line (advanced) tools and complex techniques. Incidence of all MC grew parallel to age of removed leads from 0.6 to 18.2%; haemopericardium-from 0.3 to 12.1%, severe tricuspid valve damage-from 0.2 to 2.1%, need for rescue cardiac surgery-from 0.4 to 9.1%. Notably, there was no procedure-related death when old or very old lead was extracted. The percentages of clinical and procedural success decreased with increasing age of the removed leads from 99.2 and 97.8% to 90.9 and 81.8%. The risk of MC during extraction of leads aged 10-20 years increases 6.7 times, aged 20-30 years-14.3 times (amounting to 8.4%), and aged 30 and more years-20.4 times, amounting to 18.2%. Removal of ventricular leads is associated with a greater complexity of the procedure but not with more frequent MC. Removal of the atrial leads is associated with a higher incidence of MC, especially haemopericardium, regardless of the age of the leads, although the tendency becomes less pronounced with the oldest leads. CONCLUSIONS: 1. Extraction of old and very old leads is a rising challenge, since the rate of removal of leads aged 20-and-more years almost doubles with successive five-year periods. 2. Procedure difficulty, complexity and the risk of major complications increases along with the age of extracted lead. TLE is more time-consuming, difficult and much more often requires advanced tools and complex techniques. 3. TLE of old (≥20 years) or very old (≥30 years) leads can be performed with satisfactory success rate and safety profile when conducted at high-volume centre by an experienced operator under optimal safety conditions.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Derrame Pericárdico , Humanos , Feminino , Adulto , Adulto Jovem , Remoção de Dispositivo/efeitos adversos , Estudos Retrospectivos , Estudos de Coortes , Derrame Pericárdico/etiologia , Chumbo , Resultado do Tratamento
6.
Artigo em Inglês | MEDLINE | ID: mdl-36361474

RESUMO

BACKGROUND: Lead management in children and young adults is still a matter of debate. METHODS: To assess the course of transvenous lead extraction (TLE) in adults with pacemakers implanted in childhood (CIP) we compared 98 CIP patients with a control group consisting of adults with pacemakers implanted in adulthood (AIP). RESULTS: CIP patients differed from AIP patients with respect to indications for TLE and pacing history. CIP patients were four-eight times more likely to require second-line or advanced tools. Furthermore, CIP patients more often than AIP were prone to developing complications: major complications (MC) (any) 2.6 times; hemopericardium 3.2 times; severe tricuspid valve damage 4.4 times; need for rescue cardiac surgery 3.7 times. The rate of procedural success was 11% lower because of 4.8 times more common lead remnants and 3.1 times more frequent permanently disabling complications. CONCLUSIONS: Due to system-related risk factors TLE in CIP patients is more difficult and complex. TLE in CIP is associated with an increased risk of MC and incomplete lead removal. A conservative strategy of lead management, acceptable in very old patients seems to be less suitable in CIP because it creates a subpopulation of patients at high risk of major complications during TLE in the future.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Adulto Jovem , Criança , Humanos , Adulto , Remoção de Dispositivo/efeitos adversos , Estudos Retrospectivos , Chumbo , Desfibriladores Implantáveis/efeitos adversos , Fatores de Risco , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento
7.
Kardiochir Torakochirurgia Pol ; 19(3): 122-129, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36268484

RESUMO

Introduction: The guidelines stress the importance of cardiac surgery in the management of life-threatening complications arising from lead removal. Aim: To delineate the roles of the cardiac surgeon during transvenous lead extraction (TLE). Material and methods: 3207 patients (38.7% F), average age 65.7 years, underwent the extraction of PM/ICD leads using standard non-powered mechanical systems within the last 14 years. Results: Procedural success 96.1%, clinical success 97.8%, procedure-related death 0.18%, major complications 1.9% (cardiac tamponade 1.2%, hemothorax 0.2%, tricuspid valve damage 0.3%, stroke and pulmonary embolism < 1%). The roles for cardiac surgery in TLE have been categorized into five areas: 1. Emergency cardiac surgery (1.18% of all patients), 2. Late surgical intervention (TLE-related tricuspid valve dysfunction) (0.44%), 3. Cardiac surgery complementing partially successful TLE (0.68%: removal of lead fragments), 4. Epicardial pacemaker implantation through sternotomy for the above-mentioned reasons (0.65%), 5. Delayed surgical intervention after TLE to place epicardial LV leads (0.53%). Additionally, surgical experience can help in prevention and treatment of wound infection after TLE. Conclusions: Emergency cardiac surgery (mainly due to severe bleeding) is still the most frequent reason for intervention (33.63% (38/113) of all surgical procedures). The other areas of surgical interventions in lead management are: cardiac surgery complementing partially successful TLE, repair or replacement of the malfunctioning tricuspid valve secondary to lead extraction and implantation of permanent epicardial pacing leads after sternotomy or epicardial left ventricle lead to optimize cardiac resynchronization. Experience of a single high-volume lead extraction center confirms the need for close collaboration between the cardiologist and the cardiac surgeon, whose role goes far beyond mere surgical standby.

8.
J Cardiovasc Electrophysiol ; 33(12): 2625-2639, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36054327

RESUMO

INTRODUCTION: Cardiac tamponade (CT) is one of the most common and dangerous complications of transvenous lead extraction (TLE). So far, however, there has been little discussion about the problem. METHODS: We analyzed the occurrence of CT in a group of 1226 patients undergoing TLE at a single reference center between June, 2015 and February, 2021. Using standard mechanical devices as first-line tools, a total of 2092 leads had been extracted. RESULTS: CT occurred in 18 patients (1.47%): due to injury to the wall of the right atrium in 14 patients (1.14%) and other cardiac walls in four patients (0.33%). Younger patient age at first implantation, female gender, high left ventricular ejection fraction (LVEF), lower New York Heart Association class, low Charlson comorbidity index, longer implant duration, and the number of previous procedures related to cardiac implantable electronic devices (CIED) are important patient-related risk factors for CT. Significant procedure-related risk factors include the number of extracted leads, extraction of atrial leads and longer dwell time of extracted leads. Intraoperative transoesophageal echocardiography (TEE) provides a lot of information about pulling on various cardiac structures and is able to detect a very early phase of bleeding to the pericardial sac. As a result of implementing best practices guidance in performing extraction procedures and close collaboration with cardiac surgeons that allowed immediate rescue intervention in our series of 18 CT cases, there were no procedure-related deaths (mortality 0%). CONCLUSIONS: The need for rescue surgery due to CT has no influence on clinical and procedural success. Early diagnosed (TEE monitoring) and properly managed CT does not generate any additional risk in short- and long-term follow-up after TLE.


Assuntos
Tamponamento Cardíaco , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Feminino , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Falha de Equipamento , Tamponamento Cardíaco/diagnóstico por imagem , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/terapia , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Estudos Retrospectivos , Marca-Passo Artificial/efeitos adversos
9.
J Cardiovasc Electrophysiol ; 33(7): 1357-1365, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35474258

RESUMO

INTRODUCTION: The professional society guidelines recommend that transvenous lead extraction (TLE) operating teams collaborate closely with cardiac surgeons in the management of life-threatening complications. METHODS: We assessed the role of cardiac surgeons participating in 3462 TLE procedures at a high-volume center between 2006 and 2021. The roles for cardiac surgery in TLE can be categorized into five areas: emergency surgical interventions for the management of cardiac laceration and severe bleeding (1.184%), cardiac surgery complementing partially successful TLE or vegetation removal (0.693%), delayed surgical treatment of TLE-related tricuspid valve dysfunction (0.751%), epicardial pacemaker implantation through sternotomy during emergency, complementing or delayed surgical interventions (0.607%), and delayed epicardial lead implantation (0.491%). RESULTS: Isolated damage to the wall of the right atrium was the most common cause of cardiac tamponade (53.66% of emergency surgeries) followed by injury to the right ventricle and vena cava (both 7.317%). CONCLUSIONS: Emergency cardiac surgery for the management of severe hemorrhagic complications is still the most common treatment option. The remaining areas include surgery complementing partially successful TLE: repair of tricuspid valve or epicardial ventricular lead placement to achieve permanent cardiac resynchronization. The experience at a single high-volume TLE center indicates the necessity of close collaboration with the cardiac surgeons whose roles appear broader than the mere surgical standby. Mortality in patients who survived cardiac surgery during TLE does not differ from the survival of other patients after TLE without complications requiring surgical intervention.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Cirurgiões , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
10.
Gerontology ; 67(1): 36-48, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33242867

RESUMO

INTRODUCTION: Transvenous lead extraction (TLE) has become a frequently used tool for the management of complications related to pacemakers, implantable cardiac defibrillators and cardiac resynchronization therapy devices. However, it is still a matter of debate whether the lead extraction procedure is a safe treatment choice in the elderly. METHODS: We collected the clinical information from 3,810 patients undergoing TLE in 2 high-volume centers (Poland and Italy) between 2006 and 2017. We tested risk factors, effectiveness, safety and long-term survival in 3 groups of patients: those aged 80-89.99 years, ≥90 years and 30-79.99 years. RESULTS: Lower BMI, lower levels of hemoglobin and more comorbidities characterized the patients, whose ages ranged from 80 to 89.99 years. Those aged ≥90 years most often had single-chamber pacemakers. Octogenarians and nonagenarians were more often undergoing TLE due to infectious indications (57.19 and 74.29 vs. 45.35% in younger individuals). Lead age and the number of leads extracted were comparable in the 3 groups. In octogenarians, leads were more often removed using standard extraction techniques: simple traction and mechanical dilatators, whereas in nonagenarians TLE was more complex. The duration of the procedure was shorter in older patients, while clinical and procedural effectiveness was similar to that in younger individuals. The rate of major complications related to TLE did not differ between octogenarians and younger subjects (2.0 vs. 1.38%, p = ns), and the number of procedure-related risk factors was smaller in older people. Nonagenarians did not develop any major complication related to TLE. Long-term mortality after TLE was similar among octogenarians and nonagenarians (39.67 and 40.00%) but higher than in younger patients (24.41; p < 0.001 and 0.05). CONCLUSIONS: Lead extraction procedures appear effective and safe in octogenarians and nonagenarians, comparable to younger individuals. Procedure-related risk in the elderly is not associated with most of the typical risk factors encountered in younger subjects, but only with the higher number of pacemaker, implantable cardiac defibrillator and cardiac resynchronization therapy device procedures before TLE. Long-term survival after TLE was found to be similar among octogenarians and nonagenarians being about 60% at over 3 years of follow-up. Age alone should not be considered a risk factor for the occurrence of major complications or procedure-related death, and therefore it should not prevent candidacy for TLE.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias , Procedimentos Cirúrgicos Vasculares , Fatores Etários , Idoso de 80 Anos ou mais , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Polônia/epidemiologia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Medição de Risco/métodos , Medição de Risco/estatística & dados numéricos , Fatores de Risco , Análise de Sobrevida , Tempo , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/instrumentação , Procedimentos Cirúrgicos Vasculares/métodos
11.
Kardiol Pol ; 78(12): 1206-1214, 2020 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-33078921

RESUMO

Transesophageal echocardiography (TEE) is regarded as the gold standard in diagnostic cardiology and has become an essential tool for monitoring the patient undergoing cardiac surgery and transcatheter procedures. Considering the increasing number of complications related to cardiac implantable electronic devices, TEE can also be used to detect these irregularities. Transvenous lead extraction (TLE) is the first--line treatment for cardiac implantable electronic device-related complications. The essence of TLE is the dissection of leads from connective tissue adhesions that attach them to the walls of the heart and vessels. Separation of strongly immobilized leads may cause injury to the veins or heart resulting in life--threatening bleeding. For this reason, the guidelines from the American and European cardiac societies recommend clinicians to use TEE for monitoring the patient undergoing TLE. The advantage of such an approach is immediate detection, localization, and evaluation of TLE complications and sequelae. Additionally, according to our experience, continuous monitoring of the TLE procedure enables the operator to be informed about the expected technical problems.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Ecocardiografia Transesofagiana , Humanos , Estudos Retrospectivos , Resultado do Tratamento
12.
Medicina (Kaunas) ; 56(1)2019 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-31861701

RESUMO

Background and Objectives: An increase in the incidence of end-stage renal disease (ESRD) is associated with the need for a wider use of vascular access. Although arteriovenous (A-V) fistula is a preferred form of vascular access, for various reasons, permanent catheters are implanted in many patients. Materials and Methods: A retrospective analysis of clinical data was carried out in 398 patients (204 women) who in 2010-2016 were subjected to permanent dialysis catheters implantation as first vascular access or following A-V fistula dysfunction. The factors influencing the risk of complications related to vascular access and mortality were evaluated and the comparison of the group of patients with permanent catheter implantation after A-V fistula dysfunction with patients with first-time catheter implantation was carried out. Results: The population of 398 people with ESRD with mean age of 68.73 ± 13.26 years had a total of 495 permanent catheters implanted. In 129 (32.6%) patients, catheters were implanted after dysfunction of a previously formed dialysis fistula. An upward trend was recorded in the number of permanent catheters implanted in relation to A-V fistulas. Ninety-two infectious complications (23.1%) occurred in the study population in 65 patients (16.3%). Multivariate analysis showed that permanent catheters were more often used as the first vascular access option in elderly patients and cancer patients. Mortality in the mean 1.38 ± 1.17 years (min 0.0, max 6.70 years) follow-up period amounted to 50%. Older age and atherosclerosis were the main risk factors for mortality. Patients with dialysis fistula formed before the catheter implantation had a longer lifetime compared to the group in which the catheter was the first access. Conclusion: The use of permanent catheters for dialysis therapy is associated with a relatively high incidence of complications and low long-term survival. The main factors determining long-term survival were age and atherosclerosis. Better prognosis was demonstrated in patients after the use of A-V fistula as the first vascular access option.


Assuntos
Fístula Arteriovenosa/complicações , Falência Renal Crônica/mortalidade , Diálise Renal/instrumentação , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Fístula Arteriovenosa/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Falência Renal Crônica/terapia , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Diálise Renal/efeitos adversos , Medição de Risco/métodos , Medição de Risco/normas , Fatores de Risco , Fatores de Tempo
13.
BMC Pulm Med ; 19(1): 80, 2019 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-30991994

RESUMO

BACKGROUND: Systemic artery to pulmonary artery fistulas (SA-PAFs), are extremely rare in people without congenital heart disease. In this group of patients pulmonary arterial hypertension was reported in the single case. Then, we describe a case of multiple SA-PAFs, which were the cause of severe nonreversible arterial pulmonary hypertension in a patient who had a right-sided pneumothorax 35 years earlier. CASE PRESENTATION: 52-year-old male Caucasian patient with echocardiographically confirmed pulmonary hypertension (PH) was admitted to cardiology department due to exertional dyspnea and signs of right ventricle failure. Routine screening for causes of secondary PH was negative. Right heart catheterization (RHC) confirmed a high degree arterial PH [mean pulmonary artery pressure (mPAP); 50,6 mmHg, pulmonary wedge pressure (PWP); 11,3 mmHg, pulmonary vascular resistance (PVR); 11,9 Wood's units (WU)] irreversible in the test with inhaled nitric oxide. Oxygen saturation (SaO2) of blood samples obtained during the first RHC ranged from 69.3 to 73.2%. Idiopathic pulmonary arterial hypertension was diagnosed. Treatment with inhaled iloprost and sildenafil was initiated. Control RHC, performed 5 months later showed values of mPAP (59,7 mmHg) and PVR (13,4 WU) higher in comparison to the initial measurement, SaO2 of blood obtained during RHC from upper lobe artery of the right lung was elevated and amounted 89.7%. Then, pulmonary arteriography was performed. Lack of contrast in the right upper lobe artery with the evidence of retrograde blood flow visible as a negative contrast in the right pulmonary artery was found. Afterwards, right subclavian artery arteriography detected a huge vascular malformation communicating with right upper lobe artery. Following computed tomography angiogram (angio-CT) additionally revealed the enlargement of bronchial arteries originated fistulas to pulmonary artery of right upper lobe. In spite of intensive pharmacological treatment, including the therapy of pulmonary hypertension and percutaneous embolisation of the fistulas, the patient's condition continued to deteriorate further. He died three months after embolisation due to severe heart failure complicated by pneumonia. CONCLUSION: Non-congenital SA-PAFs are extremely rare, however, they should be excluded in patients with pulmonary arterial hypertension and history of inflammatory or infectious disease of the lung and pleura, pneumothorax, cancer or Takayashu's disease and after chest trauma.


Assuntos
Fístula Artério-Arterial/complicações , Cateterismo Cardíaco , Hipertensão Pulmonar Primária Familiar/diagnóstico , Pneumotórax/complicações , Angiografia por Tomografia Computadorizada , Hipertensão Pulmonar Primária Familiar/tratamento farmacológico , Evolução Fatal , Insuficiência Cardíaca/fisiopatologia , Humanos , Iloprosta/uso terapêutico , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/patologia , Pressão Propulsora Pulmonar , Citrato de Sildenafila/uso terapêutico , Resistência Vascular
14.
Europace ; 20(8): 1324-1333, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29016781

RESUMO

Aims: To analyse the effectiveness, safety and long-term outcomes of conventional non-powered mechanical systems for transvenous lead extraction (TLE) performed by experienced first operators. Outcomes were assessed according to lead location and type of operating room in which the procedure was performed. Methods and results: Data from 2049 patients (mean age: 65 years), with infectious (40%) or non-infectious (60%) indications, were analysed over a mean of 3.37 (±2.29) years. A total of 3426 leads were extracted; and, overall, 95% full procedural, 4% partial procedural, and 98% clinical success were demonstrated. Within the patient cohort, 1.8% (37/2049) experienced major complications, with cardiac tamponade being predominant (30/37). Cardiac tamponade was identified as the main cause of mortality, as well as the cause of all procedure-related deaths (6/2049; 0.3%). Cardiac tamponade occurred in 1.8% of atrial and 0.3% of right ventricular lead extractions, with fatal tamponade reported in 9% of atrial, 40% of ventricular, and 67% of coronary sinus lead extractions. No association between lead location and cardiac tamponade-related mortality was observed; however, lead location did affect the success of pericardiocentesis. The cardiac tamponade-related mortality rate was 37% when TLE was performed in an electrophysiology laboratory. No deaths were reported when the procedure was performed in a cardiac surgery or hybrid operating room. Long-term survival was improved when TLE was performed due to non-infectious indications, rather than pocket infection or lead-related endocarditis (P < 0.001). Conclusion: Using conventional non-powered mechanical sheaths, TLE was effective even in patients at high risk of complications.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/instrumentação , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/mortalidade , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/mortalidade , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Salas Cirúrgicas , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
15.
Pol Arch Intern Med ; 127(9): 597-607, 2017 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-28724879

RESUMO

INTRODUCTION Cardiac implantable electronic device (CIED) infections still constitute a significant challenge. The knowledge of risk factors for CIED infections is crucial for preventing infections and reducing mortality rates. OBJECTIVES The aim of this study was to assess the risk factors and long-term survival of patients with CIED infections. PATIENTS AND METHODS We analyzed the clinical data of 1837 patients (including 750 [40.9%] patients with CIED infections), who underwent transvenous lead extraction at a single institution between 2006 and 2015. We compared the clinical and procedure-related factors for all types of CIED infections: isolated pocket infection (IPI), isolated lead-related infective endocarditis (ILRIE), and lead-related infective endocarditis with coexisting pocket infection (LRIE + PI). We also analyzed long-term survival rates. RESULTS The development of IPI and LRIE + PI depended mainly on age, male sex, number of leads, presence of implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-­D), and the number of previous procedures. The factors that determined ILRIE included chronic kidney disease (CKD), ICD/CRT-D, lead loops, and intracardiac lead abrasion. Chronic anticoagulation and antiplatelet treatment protected against the development of infection. Long-term survival was significantly related to age, heart failure, diabetes mellitus, CKD, malignancy, and chronic atrial fibrillation. CONCLUSIONS The development of all types of CIED infection was associated mainly with procedure-related factors, while long-­term mortality was dependent on clinical factors. The dissimilarity of factors affecting the development of IPI and ILRIE confirms that there are 2 variants of CIED infection. The protective effects of chronic anticoagulation and antiplatelet treatment should prompt us to consider such therapy in the prevention of CIED infection.


Assuntos
Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Endocardite Bacteriana/etiologia , Infecções Relacionadas à Prótese/etiologia , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Estudos Retrospectivos , Fatores de Risco
16.
Contemp Clin Trials ; 42: 239-43, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25858003

RESUMO

BACKGROUND: Dual chamber pacing is known to have detrimental effect on cardiac performance and heart failure occurring eventually is associated with increased mortality. Experimental studies of pacing in dogs have shown contractile dyssynchrony leading to diffuse alterations in extracellular matrix. In parallel, studies on experimental ischemia/reperfusion injury have shown efficacy of valsartan to inhibit activity of matrix metalloproteinase-9, to increase the activity of tissue inhibitor of matrix metalloproteinase-3 and preserve global contractility and left ventricle ejection fraction. PURPOSE: To present rationale and design of randomized blinded trial aimed to assess whether 12 month long administration of valsartan will prevent left ventricle remodeling in patients with preserved left ventricle ejection fraction (LVEF ≥ 40%) and first implantation of dual chamber pacemaker. METHODS: A total of 100 eligible patients will be randomized into three parallel arms: placebo, valsartan 80 mg/daily and valsartan 160 mg/daily added to previously used drugs. The primary endpoint will be assessment of valsartan efficacy to prevent left ventricle remodeling during 12 month follow-up. We assess patients' functional capacity, blood plasma activity of matrix metalloproteinases and their tissue inhibitors, NT-proBNP, tumor necrosis factor alpha, and Troponin T. Left ventricle function and remodeling is assessed echocardiographically: M-mode, B-mode, tissue Doppler imaging. CONCLUSION: If valsartan proves effective, it will be an attractive measure to improve long term prognosis in aging population and increasing number of pacemaker recipients. ClinicalTrials.org (NCT01805804).


Assuntos
Marca-Passo Artificial/efeitos adversos , Valsartana/administração & dosagem , Remodelação Ventricular/efeitos dos fármacos , Bloqueio Atrioventricular/cirurgia , Relação Dose-Resposta a Droga , Método Duplo-Cego , Ecocardiografia , Humanos , Metaloproteinases da Matriz/metabolismo , Peptídeo Natriurético Encefálico/imunologia , Fragmentos de Peptídeos/imunologia , Projetos de Pesquisa , Volume Sistólico , Fator de Necrose Tumoral alfa/metabolismo
17.
Intervirology ; 58(6): 350-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26845221

RESUMO

BACKGROUND: The impact of myocardial viral persistence on the clinical outcome of patients with dilated cardiomyopathy (DCM) is still open to question. METHODS: Fifty-two patients with DCM were enrolled and followed for a median of 3.8 years with respect to death or heart transplantation. Studied patients were clinically stable for at least 6 months before hospitalization. They underwent coronary angiography and endomyocardial biopsy. Specimens were examined by histo- and immunohistochemistry, and the viral genomes of parvovirus B19, cytomegalovirus (CMV), Coxsackie B virus (CVB), and hepatitis B and C viruses were studied by real-time polymerase chain reaction. RESULTS: Forty-two out of 52 patients were available for clinical follow-up. The viral genome was detected in the myocardium of 32 out of 42 patients. Among the viruses studied, CMV and CVB were the most frequently found. Nine out of 42 patients achieved the predefined study end point. No statistically significant correlation was found between the presence of a persistent viral genome and study end point. No statistically significant relationship between viral genomes studied and immunohistology results was detected. CONCLUSIONS: High prevalence of a viral genome in the myocardium of patients with DCM did not have an influence on their long-term clinical outcome.


Assuntos
Cardiomiopatia Dilatada/virologia , Genoma Viral/genética , Coração/virologia , Parvovirus B19 Humano/genética , Viroses/virologia , Adulto , Idoso , Biópsia , Cardiomiopatia Dilatada/diagnóstico , Citomegalovirus/genética , Citomegalovirus/isolamento & purificação , DNA Viral/genética , Enterovirus Humano B/genética , Enterovirus Humano B/isolamento & purificação , Feminino , Seguimentos , Hepacivirus/genética , Hepacivirus/isolamento & purificação , Vírus da Hepatite B/genética , Vírus da Hepatite B/isolamento & purificação , Humanos , Masculino , Pessoa de Meia-Idade , Parvovirus B19 Humano/isolamento & purificação
18.
Mediators Inflamm ; 2014: 585067, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25214716

RESUMO

BACKGROUND: The aim of the study was to assess the relationships among serum neopterin (NPT), ß2-microglobulin (ß2-M) levels, clinical status, and endomyocardial biopsy results of dilated cardiomyopathy patients (DCM). METHODS: Serum NPT and ß-2 M were determined in 172 nonischaemic DCM patients who underwent right ventricular endomyocardial biopsy and 30 healthy subjects (ELISA test). The cryostat biopsy specimens were assessed using histology, immunohistology, and immunochemistry methods (HLA ABC, HLA DR expression, CD3 + lymphocytes, and macrophages counts). RESULTS: The strong increase of HLA ABC or HLA DR expression was detected in 27.2% patients-group A-being low in 72.8% patients-group B. Neopterin level was increased in patients in group A compared to healthy controls 8.11 (4.50-12.57) versus 4.99 (2.66-8.28) nmol/L (P < 0.05). ß-2 microglobulin level was higher in DCM groups A (2.60 (1.71-3.58)) and B (2.52 (1.51-3.72)) than in the control group 1.75 (1.28-1.96) mg/L, P < 0.001. Neopterin correlated positively with the number of macrophages in biopsy specimens (P < 0.05) acute phase proteins: C-reactive proteins (P < 0.05); fibrinogen (P < 0.01); and NYHA functional class (P < 0.05) and negatively with left ventricular ejection fraction (P < 0.05). CONCLUSIONS: Neopterin but not ß-2 microglobulin concentration reflected immune response in biopsy specimens. Neopterin correlated with acute phase proteins and stage of heart failure and may indicate a general immune and inflammatory activation in heart failure.


Assuntos
Cardiomiopatia Dilatada/sangue , Cardiomiopatia Dilatada/imunologia , Neopterina/sangue , Neopterina/imunologia , Microglobulina beta-2/metabolismo , Adulto , Feminino , Antígenos HLA-A/metabolismo , Antígenos HLA-B/metabolismo , Antígenos HLA-C/metabolismo , Antígenos HLA-DR/metabolismo , Humanos , Imunidade/fisiologia , Inflamação/sangue , Inflamação/metabolismo , Masculino , Pessoa de Meia-Idade , Miocárdio/metabolismo
19.
Kardiol Pol ; 70(5): 533-5; discussion 536, 2012.
Artigo em Polonês | MEDLINE | ID: mdl-22623256

RESUMO

A case of a 51-year-old woman with symptoms of non-ST-segment elevation acute coronary syndrome and concomitant atrial flutter is presented. Patient underwent atrioventricular septal defect repair in childhood. Coronary angiography showed total occlusion of left main coronary artery and massive collateral network originating from right coronary artery supplying entire left coronary artery. Ablation of atrial flutter had been performed and patient was subsequently submitted to mitral valve replacement, tricuspid valvuloplasty and coronary artery bypass grafting. The potential causes of left main occlusion are in this case discussed.


Assuntos
Oclusão Coronária/etiologia , Defeitos dos Septos Cardíacos/complicações , Doenças das Valvas Cardíacas/complicações , Valva Mitral/transplante , Infarto do Miocárdio/etiologia , Adolescente , Fascículo Atrioventricular/cirurgia , Procedimentos Cirúrgicos Cardiovasculares/efeitos adversos , Ponte de Artéria Coronária , Oclusão Coronária/terapia , Feminino , Defeitos dos Septos Cardíacos/cirurgia , Septos Cardíacos/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Humanos , Pessoa de Meia-Idade , Infarto do Miocárdio/cirurgia , Valva Tricúspide/cirurgia
20.
Wiad Lek ; 65(4): 211-5, 2012.
Artigo em Polonês | MEDLINE | ID: mdl-23654140

RESUMO

INTRODUCTION: We determined retrospective analysis of the diagnostic value of virus serology in patients with non-ischemic systolic heart failure and parvovirus B19 infection. MATERIAL AND METHODS: Virus serology and endomyocardial biopsy were performed in 31 patients with non-ischemic systolic heart failure hospitalized from 2001 to 2006 in our clinic. RESULTS: The serum specimens from 31 patients were tested for IgM and IgG antibody against parvovirus B19. IgM antibodies were identified in 3 patients and IgG antibodies were identified in 23 patients. All of the patients underwent endomyocardial biopsy which revealed chronic active myocarditis in 10 patients (32.4%), chronic persistent myocarditis in 14 patients (45.1%) and no myocarditis in 7 patients (22.5%). CONCLUSIONS: Virus serology has no relevance for the diagnosis of non-ischemic systolic heart failure caused by parvovirus B19 infection. The result of serological tests are positive more frequently than the biopsy specimens results.


Assuntos
Eritema Infeccioso/complicações , Eritema Infeccioso/diagnóstico , Insuficiência Cardíaca Sistólica/virologia , Miocardite/complicações , Adulto , Anticorpos Antivirais/sangue , Biópsia , Eritema Infeccioso/imunologia , Feminino , Insuficiência Cardíaca Sistólica/patologia , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Masculino , Pessoa de Meia-Idade , Miocardite/patologia , Miocárdio/patologia , Parvovirus B19 Humano/imunologia , Estudos Retrospectivos , Testes Sorológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA