Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur Heart J Qual Care Clin Outcomes ; 9(4): 408-416, 2023 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35881482

RESUMO

AIMS: Screening for atrial fibrillation (AF) is recommended by the European Society of Cardiology guidelines to prevent strokes. Cost-effectiveness analyses of different screening programmes for AF are difficult to compare because of varying settings and models used. We compared the impact and cost-effectiveness of various AF screening programmes in the Netherlands. METHODS AND RESULTS: The base case economic analysis was conducted from the societal perspective. Health effects and costs were analysed using a Markov model. The main model inputs were derived from the ARISTOTLE, RE-LY, and ROCKET AF trials combined with Dutch observational data. Univariate, probabilistic sensitivity, and various scenario analyses were performed. The maximum number of newly detected AF patients in the Netherlands ranged from 4554 to 39 270, depending on the screening strategy used. Adequate treatment with anticoagulation would result in a maximum of >3000 strokes prevented using single-time point AF screening. Compared with no screening, screening 100 000 people provided a gain in QALYs ranging from 984 to 8727 and a mean cost difference ranging from -6650 000€ to 898 000€, depending on the screening strategy used. The probabilistic sensitivity analysis (PSA) demonstrated a 100% likelihood that screening all patients ≥75 years visiting the geriatric outpatient clinic was cost-saving. Four out of six strategies were cost-saving in ≥74% of the PSA simulations. Out of these, opportunistic screening of all patients ≥65 years visiting the GPs office had the highest impact on strokes prevented. CONCLUSION: Most single-time point AF screening strategies are cost-saving and have an important impact on stroke prevention.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Análise Custo-Benefício , Países Baixos/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Programas de Rastreamento/métodos
2.
Ther Drug Monit ; 44(6): 755-761, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36006609

RESUMO

AIM: This study examined whether anthropometric and body composition parameters such as body surface area (BSA), lean body mass (LBM), and total body weight (TBW) are correlated with docetaxel clearance and exposure by analyzing area under the curve. In addition, LBM, TBW, and a fixed dose were compared with BSA as dosing parameters for dose individualization of docetaxel. METHODS: Thirty-six patients receiving docetaxel chemotherapy for breast or metastatic castration-resistant prostate carcinoma were included. Before treatment, LBM was measured using a dual-energy X-ray absorptiometry scanner. Blood samples were collected up to 180 minutes after dosing to analyze docetaxel concentrations and determine individual pharmacokinetic parameters. RESULTS: No significant correlations were found between docetaxel clearance and the anthropometric and body composition variables (BSA, LBM, and TBW). The area under the curve was significantly but poorly correlated with BSA [r = 0.452 ( P = 0.016)] and TBW [r = 0.476 ( P = 0.011)]. The mean absolute percentage error and mean error of simulated dosing based on LBM and fixed dosing were not significantly different from those of BSA. For TBW, only mean absolute percentage error was significantly higher compared with dosing based on BSA (24.1 versus 17.1, P = 0.001). CONCLUSIONS: There was no clinically relevant correlation between docetaxel pharmacokinetics and the anthropometric and body composition variables BSA, LBM, and TBW. Therefore, dose individualization of docetaxel based on LBM, TBW, or fixed dosing cannot be recommended over BSA-based dosing.


Assuntos
Composição Corporal , Masculino , Humanos , Superfície Corporal , Docetaxel , Peso Corporal , Antropometria
3.
Europace ; 20(1): 12-18, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-27733465

RESUMO

Aims: Atrial fibrillation (AF) is the most common arrhythmia and prevalence increases with age. Patients with AF have a high risk of stroke, and screening for AF is recommended in all people aged 65 years or older to identify patients eligible for stroke prevention. A handheld, single-lead electrocardiogram (ECG) device can be used for systematic screening in the population at risk. The objective of this study is to estimate the cost-effectiveness of screening for AF in primary care with the MyDiagnostick® during seasonal influenza vaccination in the Netherlands. Methods and results: Lifetime costs and effects of a single screening session for AF detection were assessed from a societal perspective with a decision analytic model consisting of a straightforward decision tree and a joining Markov model. The decision model simulated all patients aged 65 years and over attending the seasonal influenza vaccination in the Netherlands. Event probabilities were derived from clinical trials. Sensitivity analyses were performed to assess the impact of important model assumptions as well as determining the relative effect of individual parameters. Screening for AF with the MyDiagnostick® in all patients older than 65 years that attend seasonal influenza vaccination in the Netherlands would decrease the overall costs by €764 and increase the quality-adjusted life-years (QALYs) by 0.27 years per patient. Early detection of AF would prevent strokes and leads to beneficial health effects with subsequent cost savings. This screening method would have an estimated probability of 99.8% for being cost-effective at a conservative willingness-to-pay of €20 000/QALY. Conclusion: Screening for AF in primary care with a handheld, single-lead ECG during seasonal influenza vaccination is very likely to be cost saving for identifying new cases of AF in the Dutch population aged 65 years and over. Active screening for AF with a single-lead, handheld ECG device during seasonal influenza vaccination could be implemented in primary care.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/economia , Eletrocardiografia/economia , Custos de Cuidados de Saúde , Programas de Rastreamento/economia , Testes Imediatos/economia , Atenção Primária à Saúde/economia , Idoso , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Tomada de Decisão Clínica , Simulação por Computador , Redução de Custos , Análise Custo-Benefício , Técnicas de Apoio para a Decisão , Árvores de Decisões , Eletrocardiografia/instrumentação , Feminino , Humanos , Vacinas contra Influenza/administração & dosagem , Masculino , Cadeias de Markov , Programas de Rastreamento/instrumentação , Modelos Econômicos , Países Baixos/epidemiologia , Valor Preditivo dos Testes , Anos de Vida Ajustados por Qualidade de Vida , Reprodutibilidade dos Testes , Acidente Vascular Cerebral/economia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Vacinação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA