Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
2.
J Nucl Cardiol ; 30(6): 2692-2701, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37592058

RESUMO

BACKGROUND: Normal stress-only (SO) myocardial perfusion imaging (MPI) using SPECT reduces imaging time and radiation dose with a good prognosis. However, the long-term prognostic value of combining coronary artery calcium score (CACS) with SO MPI to determine the warranty period remains unknown. Hence, we assessed the incremental prognostic value of CACS and its impact on the warranty period of normal SO MPI using SPECT. METHODS: We retrospectively included 1375 symptomatic patients without a history of coronary artery disease (CAD) and a normal SO MPI using adenosine who underwent simultaneous CAC scoring. Annual major adverse cardiac events (MACE) rates were calculated for CACS categories: 0, 1-399, 400-999, and ≥1000. RESULTS: The mean age was 60.0 ± 11.8 years (66.9% female) with a median follow-up of 10.3 [IQR 9.6-10.9] years. The warranty period for annual MACE rate for normal SO SPECT extended the total follow-up time in years. MACE rate categorized by CAC categories demonstrated an increase in MACE rates with increasing CACS; CACS 0 and CACS 1-399 were associated with a 10-year warranty period, CACS 400-999 had a warranty period of 4 years and no warranty period could be given for CACS≥1000 (5.9 % at 1 year). CONCLUSIONS: CACS as an adjunct to normal pharmacological SO MPI provides additional prognostic information and aids in determining a warranty period.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Cálcio , Vasos Coronários/diagnóstico por imagem , Estudos Retrospectivos , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único , Doença da Artéria Coronariana/diagnóstico por imagem , Prognóstico , Angiografia Coronária/métodos
3.
Surg Oncol ; 47: 101909, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36739788

RESUMO

BACKGROUND: We studied the added value of digital FDG-PET/CT in disease staging and restaging compared to the standard work-up with contrast enhanced CT (ceCT) and CA19-9 in patients with resectable or borderline resectable pancreatic cancer who received neo-adjuvant therapy. Primary endpoints were tumor response compared to ceCT and CA19.9 as well as the ability to detect distant metastatic disease. METHODS: 35 patients were included in this dual-center prospective study. FDG-PET using digital photon counting technology combined with CT scans were acquired before (T1) and after neo-adjuvant therapy (T2). Patients were staged and restaged based on standard protocol with ceCT and CA 19.9, while all PET/CT scans were stored securely and not included in clinical decision making. After the pancreatic resection, an expert team retrospectively assessed the CT tumor diameter, CA19-9, tumor FDG-uptake, and appearance of metastatic disease of all patients for both time points. RESULTS: CA19-9 levels, CT tumor diameter, and tumor FDG-uptake on PET significantly decreased from T1 to T2 (p = 0.017, p = 0.001, and p < 0.0001). The change in FDG-uptake values showed a strong positive correlation with the change in CT tumor diameter and change in CA19-9 (R = 0.75 and R = 0.73, respectively). In addition, small-volume liver lesions were detected on digital PET/CT in 5/35 patients (14%), 4 of which were pathology confirmed at laparotomy. Only one of these five cases was detected on baseline staging ceCT (3%). CONCLUSION: We found that adding digital PET/CT strengthens restaging after neo-adjuvant therapy based on the observed strong correlation with ceCT tumor diameter and Ca19.9. Also, digital PET/CT was found to detect occult metastatic disease not visualized on ceCT, that would have resulted in altered disease staging and therapeutic strategy in a substantial proportion of patients.


Assuntos
Neoplasias Pancreáticas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18 , Antígeno CA-19-9/uso terapêutico , Estudos Retrospectivos , Estudos Prospectivos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/cirurgia , Neoplasias Pancreáticas/tratamento farmacológico , Estadiamento de Neoplasias , Compostos Radiofarmacêuticos/uso terapêutico , Neoplasias Pancreáticas
4.
Ann Nucl Med ; 36(8): 756-764, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35727433

RESUMO

PURPOSE: Digital PET systems (dPET) improve lesion detectability as compared to PET systems with conventional photomultiplier tubes (cPET). We prospectively studied the performance of high-resolution digital PET scans in patients with cancer, as compared with high- and standard-resolution conventional PET scans, taking the acquisition order into account. METHODS: We included 212 patients with cancer, who were referred for disease staging or restaging. All patients underwent FDG-PET/CT on a dPET scanner and on a cPET scanner in a randomized order. The scans were acquired immediately after each other. Three image reconstructions were generated: 1) standard-resolution (4 × 4 × 4 mm3 voxels) cPET, 2) high-resolution (2 × 2 × 2 mm3 voxels) cPET, and 3) high-resolution dPET. Two experienced PET readers visually assessed the three reconstructions side-by-side and ranked them according to scan preference, in an independent and blinded fashion. RESULTS: On high-resolution dPET, the PET readers detected more lesions or they had a higher diagnostic confidence than on high- and standard-resolution cPET (p < 0.001). High-resolution dPET was preferred in 90% of the cases, as compared to 44% for high-resolution cPET and 1% for standard-resolution cPET (p < 0.001). However, for the subgroup of patients where dPET was made first (n = 103, 61 ± 10 min after FDG administration) and cPET was made second (93 ± 15 min after FDG administration), no significant difference in preference was found between the high-resolution cPET and dPET reconstructions (p = 0.41). CONCLUSIONS: DPET scanners in combination with high-resolution reconstructions clinically outperform cPET scanners with both high- and standard-resolution reconstructions as the PET readers identified more FDG-avid lesions, their diagnostic confidence was increased, and they visually preferred dPET. However, when dPET was made first, high-resolution dPET and high-resolution cPET showed similar performance, indicating the positive effect of a prolonged FDG uptake time. Therefore, high-resolution cPET in combination with a prolonged FDG uptake time can be considered as an alternative.


Assuntos
Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Fluordesoxiglucose F18 , Humanos , Processamento de Imagem Assistida por Computador , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos
5.
Laryngoscope Investig Otolaryngol ; 5(6): 1247-1253, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33364418

RESUMO

OBJECTIVE: The aim of this study was to determine the adherence to consensus guidelines on preoperative imaging of patients with primary hyperparathyroidism (pHPT) in real local practice. METHODS: This was a retrospective multicenter cohort study of 411 patients undergoing parathyroidectomy for pHPT from 2007 to 2017 in three referral centers. RESULTS: In 286/411 patients (69%) the preoperative imaging workup adhered to guidelines (utilizing ultrasound and parathyroid scintigraphy). In patients in whom guidelines were followed 63% were discharged within one day versus 37% in whom guidelines were not followed (P < .0005). The use of a bimodality imaging workup, starting with ultrasound and parathyroid scintigraphy followed by imaging upscaling aiming for anatomical and functional concordance, was a predictor for the performance of a minimally invasive parathyroidectomy (OR 4.098, 95% CI 2.296-7.315, P < .0005). CONCLUSION: The level of compliance to preoperative imaging guidelines is suboptimal in this population. Patients in whom adherence was achieved showed a shorter length of stay. More education of physicians is required regarding the appropriate preoperative imaging workup in pHPT. LEVEL OF EVIDENCE: 2b (individual cohort study).

6.
J Nucl Med ; 61(10): 1448-1454, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32060217

RESUMO

Recently introduced PET systems using silicon photomultipliers with digital readout (dPET) have an improved timing and spatial resolution, aiming at a better image quality than conventional PET (cPET) systems. We prospectively evaluated the performance of a dPET system in patients with cancer, as compared with high-resolution (HR) cPET imaging. Methods: After a single 18F-FDG injection, 66 patients underwent dPET and cPET imaging in randomized order. We used HR reconstructions (2 × 2 × 2 mm voxels) for both scanners and determined SUVmax, SUVmean, lesion-to-background ratio (LBR), metabolic tumor volume (MTV), and lesion diameter in up to 5 18F-FDG-positive lesions per patient. Furthermore, we counted the number of visible and measurable lesions on each PET scan. Two nuclear medicine specialists determined, in a masked manner, the TNM score from both image sets in 30 patients referred for initial staging. For all 66 patients, these specialists separately evaluated image quality (4-point scale) and determined the scan preference. Results: We included 238 lesions that were visible and measurable on both PET scans. For 27 patients, we found 37 additional lesions on dPET (41%) that were unmeasurable (n = 14) or invisible (n = 23) on cPET. Mean (±SD) SUVmean, SUVmax, LBR, and MTV on cPET were 5.2 ± 3.9, 6.9 ± 5.6, 5.0 ± 3.6, and 2,991 ± 13,251 mm3, respectively. On dPET, SUVmean, SUVmax, and LBR increased by 24%, 23%, and 27%, respectively (P < 0.001) whereas MTV decreased by 13% (P < 0.001), compared with cPET. Visual analysis showed TNM upstaging with dPET in 13% of the patients (4/30). dPET images also had higher scores for quality (P = 0.003) and were visually preferred in most cases (65%). Conclusion: dPET improved the detection of small lesions, upstaged the disease, and produced images that were visually preferred to those from HR cPET. More studies are necessary to confirm the superior diagnostic performance of dPET.Keywords: digital PET; conventional PET; FDG PET; lesion detection; cancer imaging.


Assuntos
Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias/patologia , Estudos Prospectivos
7.
EJNMMI Res ; 9(1): 106, 2019 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-31823097

RESUMO

BACKGROUND: A high SUV-reproducibility is crucial when different PET scanners are in use. We evaluated the SUV variability in whole-body FDG-PET scans of patients with suspected or proven cancer using an EARL-accredited conventional and digital PET scanner. In a head-to-head comparison we studied images of 50 patients acquired on a conventional scanner (cPET, Ingenuity TF PET/CT, Philips) and compared them with images acquired on a digital scanner (dPET, Vereos PET/CT, Philips). The PET scanning order was randomised and EARL-compatible reconstructions were applied. We measured SUVmean, SUVpeak, SUVmax and lesion diameter in up to 5 FDG-positive lesions per patient. The relative difference ΔSUV between cPET and dPET was calculated for each SUV-parameter. Furthermore, we calculated repeatability coefficients, reflecting the 95% confidence interval of ΔSUV. RESULTS: We included 128 lesions with an average size of 19 ± 14 mm. Average ΔSUVs were 6-8% with dPET values being higher for all three SUV-parameters (p < 0.001). ΔSUVmax was significantly higher than ΔSUVmean (8% vs. 6%, p = 0.002) and than ΔSUVpeak (8% vs. 7%, p = 0.03). Repeatability coefficients across individual lesions were 27% (ΔSUVmean and ΔSUVpeak) and 33% (ΔSUVmax) (p < 0.001). CONCLUSIONS: With EARL-accredited conventional and digital PET, we found a limited SUV variability with average differences up to 8%. Furthermore, only a limited number of lesions showed a SUV difference of more than 30%. These findings indicate that EARL standardisation works. TRIAL REGISTRATION: This prospective study was registered on the 31th of October 2017 at ClinicalTrials.cov. URL: https://clinicaltrials.gov/ct2/show/NCT03457506?id=03457506&rank=1.

8.
J Nucl Cardiol ; 26(2): 602-612, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-28916890

RESUMO

BACKGROUND: In patients with normal SPECT but persistent complaints, invasive angiography may exclude obstructive coronary disease. We assessed whether high coronary artery calcium (CAC) scores are associated with increased referral for invasive angiography following normal SPECT. METHODS AND RESULTS: 2286 consecutive patients (mean age 60 ± 12, 39% male) with normal SPECT were assessed. All patients underwent simultaneous CAC scoring. Patients were categorized into four groups based on their CAC score: CAC = 0 (n = 694), CAC 1 to 100 (n = 891), CAC 101 to 400 (n = 368), and CAC >400 (n = 333). The decision to perform angiography was left to the discretion of treating physician. Follow-up angiography was confined to the first 60 days after SPECT. Occurrence of MACE (late revascularization, myocardial infarction or death) was recorded. Overall, 100 patients (4.4%) underwent early angiography with increasing rates in higher CAC score groups (1.0%, 2.6%, 8.4%, and 11.7%), respectively, P < .001). A CAC score >400 (OR 3.56, 95% CI 2.19 to 5.77, P < .001) was independently associated with referral to angiography. Similarly, CAC score >400 was an independent predictor for MACE (HR 9.26, 95% CI 5.06 to 16.93). Early angiography did not influence prognosis (HR 1.57, 95% CI 0.91 to 2.73). CONCLUSIONS: CAC scoring impacts clinical decision-making and increases referral rates for invasive angiography after normal SPECT.


Assuntos
Cálcio/metabolismo , Cardiologia/normas , Angiografia Coronária , Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Calcinose/patologia , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Perfusão , Prognóstico , Encaminhamento e Consulta
9.
EJNMMI Res ; 8(1): 3, 2018 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-29340798

RESUMO

BACKGROUND: We evaluated the diagnostic implications of a small-voxel reconstruction for lymph node characterization in breast cancer patients, using state-of-the-art FDG-PET/CT. We included 69 FDG-PET/CT scans from breast cancer patients. PET data were reconstructed using standard 4 × 4 × 4 mm3 and small 2 × 2 × 2 mm3 voxels. Two hundred thirty loco-regional lymph nodes were included, of which 209 nodes were visualised on PET/CT. All nodes were visually scored as benign or malignant, and SUVmax and TBratio(=SUVmax/SUVbackground) were measured. Final diagnosis was based on histological or imaging information. We determined the accuracy, sensitivity and specificity for both reconstruction methods and calculated optimal cut-off values to distinguish benign from malignant nodes. RESULTS: Sixty-one benign and 169 malignant lymph nodes were included. Visual evaluation accuracy was 73% (sensitivity 67%, specificity 89%) on standard-voxel images and 77% (sensitivity 78%, specificity 74%) on small-voxel images (p = 0.13). Across malignant nodes visualised on PET/CT, the small-voxel score was more often correct compared with the standard-voxel score (89 vs. 76%, p <  0.001). In benign nodes, the standard-voxel score was more often correct (89 vs. 74%, p = 0.04). Quantitative data were based on the 61 benign and 148 malignant lymph nodes visualised on PET/CT. SUVs and TBratio were on average 3.0 and 1.6 times higher in malignant nodes compared to those in benign nodes (p <  0.001), on standard- and small-voxel PET images respectively. Small-voxel PET showed average increases in SUVmax and TBratio of typically 40% over standard-voxel PET. The optimal SUVmax cut-off using standard-voxels was 1.8 (sensitivity 81%, specificity 95%, accuracy 85%) while for small-voxels, the optimal SUVmax cut-off was 2.6 (sensitivity 78%, specificity 98%, accuracy 84%). Differences in accuracy were non-significant. CONCLUSIONS: Small-voxel PET/CT improves the sensitivity of visual lymph node characterization and provides a higher detection rate of malignant lymph nodes. However, small-voxel PET/CT also introduced more false-positive results in benign nodes. Across all nodes, differences in accuracy were non-significant. Quantitatively, small-voxel images require higher cut-off values. Readers have to adapt their reference standards.

10.
Am Heart J ; 186: 56-62, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28454833

RESUMO

The impact of coronary artery calcium (CAC) scoring on subsequent changes in cardiovascular medication use in symptomatic patients with normal myocardial perfusion imaging (MPI) findings is not well established. The aim of the current study was to evaluate changes in aspirin and statin use in patients suspected for coronary artery disease after CAC scoring and normal single photon emission computed tomography (SPECT) MPI. METHODS: In the current study, 1,033 stable symptomatic patients without a known history of coronary artery disease with normal SPECT MPI who underwent concomitant CAC scoring were included. All patients had a clinical indication for imaging, mainly atypical chest pain and dyspnea, and were referred from the outpatient clinic of our hospital. Data regarding posttest medication change (either starting or discontinuation of aspirin and statin therapy at the subsequent outpatient visit) were retrospectively collected. Patients were categorized into 4 groups based on their CAC score. RESULTS: Mean age of the patients was 61±11 years and 39% were male. At baseline, 35% of the patients used aspirin and 39% used statin. In patients with CAC scores 0, 1-99, 100-399, and ≥400, aspirin was started in 1%, 4%, 9%, and 9%, respectively, and statin was started in 0%, 7%, 18%, and 24% of the patients, respectively (P<.001). Aspirin was discontinued in 19%, 11%, 7%, and 1% and statin was discontinued in 8%, 6%, 2%, and 0% (P<.001) of the patients in these respective CAC score categories. After correction for differences in risk factors and baseline medication use, increased CAC was independently associated with posttest aspirin (odds ratio 4.6, 11.2, and 27.1 for CAC scores 1-99, 100-399, and ≥400, respectively; P<.001) and statin use (odds ratio 4.4, 19.4, and 60.9 for CAC scores 1-99, 100-399, and ≥400, respectively; P<.001). CONCLUSIONS: Higher CAC scores are associated with the initiation of aspirin and statin therapy in patients with normal SPECT MPI. In patients with lower CAC scores, discontinuation of cardioprotective medication is more likely. CAC score is independently associated with posttest statin and aspirin use.


Assuntos
Calcinose/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/tratamento farmacológico , Vasos Coronários/diagnóstico por imagem , Aspirina/uso terapêutico , Feminino , Fibrinolíticos/uso terapêutico , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único
11.
J Nucl Med ; 58(9): 1459-1463, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28450561

RESUMO

The prognostic value of myocardial perfusion imaging (MPI) with the cadmium-zinc-telluride (CZT) SPECT camera is not well established. Therefore, the aim of the current study was to evaluate the prognostic value of MPI performed with a CZT SPECT camera in a large cohort of patients suspected of having coronary artery disease. Methods: Consecutive symptomatic stable patients (n = 4,057) without a history of coronary artery disease underwent CZT SPECT MPI. During a median follow-up of 2.4 y (25th-75th percentile, 1.7-3.4), patients were monitored for primary (nonfatal myocardial infarction and cardiac mortality) and secondary outcomes (late revascularization [>90 d after scanning] and primary outcome). Results: Patients with normal perfusion demonstrated low annual event rates (primary outcome, 0.2%; secondary outcome, 0.6%). Annual event rates increased with the extent of abnormality of myocardial perfusion. In patients with small ischemic perfusion defects, annual event rates were 0.7% and 2.8% for the primary and secondary outcome, respectively. In patients with moderate or large ischemic perfusion defects, these event rates were 1.2% and 4.3%, respectively. After multivariate analysis, the risk for events was significantly associated with the extent of ischemia (hazard ratio for small ischemic defects: 2.2, 95% confidence interval [CI], 0.9-5.9 and 4.6, 95% CI, 2.8-7.6, for primary and secondary outcomes, respectively; hazard ratio for moderate or large ischemic defects: 4.0, 95% CI, 1.5-10.5 and 12.1, 95% CI, 7.2-20.2, for primary and secondary outcomes, respectively). Conclusion: Our findings show that MPI acquired with a CZT SPECT camera provides excellent prognostic information, with low event rates in patients with normal myocardial perfusion. In patients with abnormal SPECT MPI, the extent of abnormality is independently associated with an increased risk of events.


Assuntos
Cádmio , Doença da Artéria Coronariana/diagnóstico por imagem , Câmaras gama , Imagem de Perfusão do Miocárdio/instrumentação , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Zinco , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico
12.
EJNMMI Phys ; 4(1): 9, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28144857

RESUMO

BACKGROUND: Our aim was to evaluate if a recently introduced TOF PET system with digital photon counting technology (Philips Healthcare), potentially providing an improved image quality over analogue systems, can fulfil EANM research Ltd (EARL) accreditation specifications for tumour imaging with FDG-PET/CT. FINDINGS: We have performed a phantom study on a digital TOF PET system using a NEMA NU2-2001 image quality phantom with six fillable spheres. Phantom preparation and PET/CT acquisition were performed according to the European Association of Nuclear Medicine (EANM) guidelines. We made list-mode ordered-subsets expectation maximization (OSEM) TOF PET reconstructions, with default settings, three voxel sizes (4 × 4 × 4 mm3, 2 × 2 × 2 mm3 and 1 × 1 × 1 mm3) and with/without point spread function (PSF) modelling. On each PET dataset, mean and maximum activity concentration recovery coefficients (RCmean and RCmax) were calculated for all phantom spheres and compared to EARL accreditation specifications. The RCs of the 4 × 4 × 4 mm3 voxel dataset without PSF modelling proved closest to EARL specifications. Next, we added a Gaussian post-smoothing filter with varying kernel widths of 1-7 mm. EARL specifications were fulfilled when using kernel widths of 2 to 4 mm. CONCLUSIONS: TOF PET using digital photon counting technology fulfils EARL accreditation specifications for FDG-PET/CT tumour imaging when using an OSEM reconstruction with 4 × 4 × 4 mm3 voxels, no PSF modelling and including a Gaussian post-smoothing filter of 2 to 4 mm.

13.
J Nucl Cardiol ; 24(1): 212-223, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-26396025

RESUMO

BACKGROUND: Performing both single photon emission computerized tomography (SPECT) and coronary computed tomography angiography (CCTA) in patients suspected for coronary artery disease (CAD) leads to increased radiation exposure. We evaluated the need for additional imaging and following implications for radiation exposure of a sequential SPECT/computed tomography (CT) algorithm. METHODS AND RESULTS: 5018 consecutive patients without history of CAD were referred for stress-first SPECT and coronary artery calcium (CAC) scoring. If stress SPECT was abnormal, additional rest SPECT and, if feasible, CCTA were acquired. Stress SPECT was normal in 2617 patients (52%). CCTA was not performed in 1289 of the 2401 patients referred for additional imaging (54%), mainly because of severe CAC (47%) or fast/irregular heart rate (22%). 642 patients with abnormal SPECT underwent CCTA, which excluded significant CAD in 378 patients (59%). Mean radiation dose was 4.5 ± 0.3 mSv for stress-only imaging and 13.2 ± 3.3 mSv for additional imaging (P < 0.001). CONCLUSIONS: Half of the patients do not require additional imaging in our sequential SPECT/CT algorithm, which is accompanied with low radiation exposure. CCTA cannot be performed in half of the patients who undergo additional imaging because of (relative) contra-indications. CCTA is able to correct for false-positive SPECT findings in our algorithm.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Uso Excessivo dos Serviços de Saúde/estatística & dados numéricos , Exposição à Radiação/prevenção & controle , Exposição à Radiação/estatística & dados numéricos , Encaminhamento e Consulta/estatística & dados numéricos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Progressão da Doença , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Avaliação das Necessidades , Países Baixos/epidemiologia , Prevalência , Fatores de Risco , Técnica de Subtração/estatística & dados numéricos , Revisão da Utilização de Recursos de Saúde
14.
J Interv Card Electrophysiol ; 48(1): 105-110, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27785663

RESUMO

PURPOSE: New X-ray technology providing new image processing techniques may reduce radiation exposure. The aim of this study was to quantify this radiation exposure reduction for patients during pacemaker and implantable cardioverter defibrillator (ICD) implantation. METHODS: In this retrospective study, 1185 consecutive patients who had undergone de novo pacemaker or ICD implantation during a 2-year period were included. All implantations in the first year were performed using the reference technology (Allura Xper), whereas in the second year, the new X-ray technology (AlluraClarity) was used. Radiation exposure, expressed as the dose area product (DAP), was compared between the two time periods to determine the radiation exposure reduction for pacemaker and ICD implantations without cardiac resynchronization therapy (CRT) and with CRT. Procedure duration and contrast volume were used as measures to compare complexity and image quality. RESULTS: The study population consisted of 591 patients who had undergone an implantation using the reference technology, and 594 patients with the new X-ray technology. The two groups did not differ in age, gender, or body mass index. The DAP decreased with 69 % from 16.4 ± 18.5 to 5.2 ± 6.6 Gy cm2 for the non-CRT implantations (p < 0.001). The DAP decreased with 75 % from 72.1 ± 60.0 to 17.8 ± 17.4 Gy cm2 for the CRT implantations (p < 0.001). Nevertheless, procedure duration and contrast volume did not differ when using the new technology (p = 0.09 and p = 0.20, respectively). CONCLUSIONS: Introduction of new X-ray technology resulted in a radiation exposure reduction of more than 69 % for patients during pacemaker and ICD implantation while image quality was unaffected.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Marca-Passo Artificial/estatística & dados numéricos , Exposição à Radiação/estatística & dados numéricos , Radiografia Intervencionista/instrumentação , Radiografia Intervencionista/estatística & dados numéricos , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Países Baixos/epidemiologia , Implantação de Prótese/métodos , Implantação de Prótese/estatística & dados numéricos , Doses de Radiação , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Proteção Radiológica/métodos , Proteção Radiológica/estatística & dados numéricos , Estudos Retrospectivos
15.
Am J Cardiol ; 118(11): 1611-1615, 2016 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-27717443

RESUMO

The coronary artery calcium (CAC) score provides independent prognostic value on top of single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). We sought to determine whether the prognostic value of the CAC score in patients with normal SPECT MPI is gender specific. We studied 3,705 consecutive symptomatic patients without a history of coronary artery disease with normal SPECT MPI. All patients underwent concomitant CAC scoring, which was categorized as CAC score 0, 1 to 99, 100 to 399, 400 to 999, or ≥1,000. Major adverse cardiac events were defined as revascularization, nonfatal myocardial infarction, or all-cause mortality. The median CAC score was 9 in women (interquartile range 0 to 113) and 47 in men (interquartile range 1 to 307, p <0.001). The annual event rate was lower in women than in men (1.6% and 2.7%, respectively, p <0.001). When stratified by CAC score, annual event rates were similar (for women and men, respectively: CAC score 0, 0.6% and 0.5%, p = 0.95; CAC score 1 to 99, 0.9% and 1.2%, p = 0.45; CAC score 100 to 399, 2.7% and 3.8%, p = 0.23; CAC score 400 to 999, 3.8% and 5.3%, p = 0.34; CAC score ≥1,000, 8.4% and 8.7%, p = 0.99). The CAC score was an independent predictor of major adverse cardiac events in both genders (CAC score ≥1,000: hazard ratio for women 8.5, 95% confidence interval 4.0 to 18.1; hazard ratio for men 14.8, 95% confidence interval 5.3 to 41.1). In conclusion, risk for events is similar for both genders when stratified by CAC score, wherein a high CAC score carries a high risk for events despite normal SPECT MPI. Our findings do not reveal a gender-specific prognostic value of the CAC score.


Assuntos
Calcinose/epidemiologia , Cálcio/metabolismo , Doença da Artéria Coronariana/epidemiologia , Vasos Coronários/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Fatores Etários , Calcinose/diagnóstico , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/metabolismo , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Prognóstico , Estudos Prospectivos , Fatores de Risco
16.
EJNMMI Phys ; 3(1): 22, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27682837

RESUMO

BACKGROUND: For tumour imaging with PET, the literature proposes to administer a patient-specific FDG activity that depends quadratically on a patient's body weight. However, a practical approach on how to implement such a protocol in clinical practice is currently lacking. We aimed to provide a practical method to determine a FDG activity formula for whole-body PET examinations that satisfies both the EANM guidelines and this quadratic relation. RESULTS: We have developed a methodology that results in a formula describing the patient-specific FDG activity to administer. A PET study using the NEMA NU-2001 image quality phantom forms the basis of our method. This phantom needs to be filled with 2.0 and 20.0 kBq FDG/mL in the background and spheres, respectively. After a PET acquisition of 10 min, a reconstruction has to be performed that results in sphere recovery coefficients (RCs) that are within the specifications as defined by the EANM Research Ltd (EARL). By performing reconstructions based on shorter scan durations, the minimal scan time per bed position (T min) needs to be extracted using an image coefficient of variation (COV) of 15 %. At T min, the RCs should be within EARL specifications as well. Finally, the FDG activity (in MBq) to administer can be described by [Formula: see text] with c a constant that is typically 0.0533 (MBq/kg(2)), w the patient's body weight (in kg), and t the scan time per bed position that is chosen in a clinical setting (in seconds). We successfully demonstrated this methodology using a state-of-the-art PET/CT scanner. CONCLUSIONS: We provide a practical method that results in a formula describing the FDG activity to administer to individual patients for whole-body PET examinations, taking into account both the EANM guidelines and a quadratic relation between FDG activity and patient's body weight. This formula is generally applicable to any PET system, using a specified image reconstruction and scan time per bed position.

17.
Ann Nucl Med ; 30(2): 145-52, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26644009

RESUMO

OBJECTIVE: Modern PET/CT scanners have significantly improved detectors and fast time-of-flight (TOF) performance and this may improve clinical performance. The aim of this study was to analyze the impact of a current generation TOF PET/CT scanner on standardized uptake values (SUV), lesion-background contrast and characterization of the adrenal glands in patients with suspected lung cancer, in comparison with literature data and commonly used SUV cut-off levels. METHODS: We included 149 adrenal glands from 88 patients with suspected lung cancer, who underwent (18)F-FDG PET/CT. We measured the SUVmax in the adrenal gland and compared this with liver SUVmean to calculate the adrenal-to-liver ratio (AL ratio). Results were compared with literature derived with older scanners, with SUVmax values of 1.0 and 1.8 for normal glands [1, 2]. Final diagnosis was based on histological proof or follow-up imaging. We proposed cut-off values for optimal separation of benign from malignant glands. RESULTS: In 127 benign and 22 malignant adrenal glands, SUVmax values were 2.3 ± 0.7 (mean ± SD) and 7.8 ± 3.2 respectively (p < 0.01). Corresponding AL ratios were 1.0 ± 0.3 and 3.5 ± 1.4 respectively (p < 0.01). With a SUVmax cut-off value of 3.7, 96% sensitivity and 96% specificity was reached. An AL ratio cut-off value of 1.8 resulted in 91% sensitivity and 97% specificity. The ability of both SUVmax and AL ratio to separate benign from malignant glands was similar (AUC 0.989 vs. 0.993, p = 0.22). CONCLUSIONS: Compared with literature based on the previous generation of PET scanners, current generation TOF (18)F-FDG PET/CT imaging provides higher SUVs for benign adrenal glands, while it maintains a highly accurate distinction between benign and malignant glands. Clinical implementation of current generation TOF PET/CT requires not only the use of higher cut-off levels but also visual adaptation by PET readers.


Assuntos
Neoplasias das Glândulas Suprarrenais/diagnóstico , Neoplasias das Glândulas Suprarrenais/metabolismo , Glândulas Suprarrenais/metabolismo , Fluordesoxiglucose F18/metabolismo , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Neoplasias das Glândulas Suprarrenais/patologia , Glândulas Suprarrenais/diagnóstico por imagem , Glândulas Suprarrenais/patologia , Idoso , Transporte Biológico , Feminino , Humanos , Masculino , Imagem Multimodal , Tamanho do Órgão , Sensibilidade e Especificidade
18.
J Nucl Med Technol ; 43(1): 21-7, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25613334

RESUMO

UNLABELLED: A major disadvantage of (18)F-FDG PET involves poor detection of small lesions and lesions with low metabolism, caused by limited spatial resolution and relatively large image voxel size. As spatial resolution and sensitivity are better in new PET systems, it is expected that small-lesion detection could be improved using smaller voxels. The aim of this study was to test this hypothesis using a state-of-the-art time-of-flight PET/CT device. METHODS: (18)F-FDG PET scans of 2 image-quality phantoms (sphere sizes, 4-37 mm) and 39 consecutive patients with lung cancer were analyzed on a time-of-flight PET/CT system. Images were iteratively reconstructed with standard 4 × 4 × 4 mm voxels and smaller 2 × 2 × 2 mm voxels. For the phantom study, we determined contrast-recovery coefficients and signal-to-noise ratios (SNRs). For the patient study, (18)F-FDG PET-positive lesions in the chest and upper abdomen with a volume less than 3.0 mL (diameter, <18 mm) were included. Lesion mean and maximum standardized uptake values (SUVmean and SUVmax, respectively) were determined in both image sets. SNRs were determined by comparing SUVmax and SUVmean with background noise levels. A subanalysis was performed for lesions less than 0.75 mL (diameter, <11 mm). For qualitative analysis of patient data, 3 experienced nuclear medicine physicians gave their preference after visual side-by-side analysis. RESULTS: For phantom spheres 13 mm or less, we found higher contrast-recovery coefficients and SNRs using small-voxel reconstructions. For 66 included (18)F-FDG PET-positive lesions, the average increase in SUVmean and SUVmax using the small-voxel images was 17% and 32%, respectively (P < 0.01). For lesions less than 0.75 mL (21 in total), the average increase was 21% and 44%, respectively. Moreover, averaged over all lesions, the mean and maximum SNR increased by 20% and 27%, respectively (P < 0.01). For lesions less than 0.75 mL, these values increased up to 23% and 46%, respectively. The physicians preferred the small-voxel reconstructions in 76% of cases. CONCLUSION: Supported by a phantom study, there was a visual preference toward (18)F-FDG PET images reconstructed with 2 × 2 × 2 mm voxels and a profound increase in standardized uptake value and SNR for small lesions. Hence, it is expected that small-lesion detection improves using small-voxel reconstructions.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Carga Tumoral , Fluordesoxiglucose F18 , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Imagem Multimodal/instrumentação , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/instrumentação , Fatores de Tempo , Tomografia Computadorizada por Raios X/instrumentação
19.
Nucl Med Commun ; 36(2): 143-7, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25356621

RESUMO

BACKGROUND: Proton-pump inhibitors (PPIs) induce potentially interfering stomach wall activity in single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) with technetium-99m ((99m)Tc)-sestamibi. However, no data are available for (99m)Tc-tetrofosmin. We assessed the influence of prolonged (>2 weeks) PPI use on the stomach wall uptake of (99m)Tc-tetrofosmin in patients referred for stress MPI with a cadmium-zinc-telluride-based SPECT camera and its relation with dyspepsia symptoms. METHODS AND RESULTS: Consecutive patients (n=127) underwent a 1-day adenosine stress-first SPECT-MPI with (99m)Tc-tetrofosmin, of whom 54 (43%) patients had been on PPIs for more than 2 weeks. Stomach wall activity was identified on stress SPECT using computed tomographic attenuation maps and was scored using a four-point grading scale into clinically relevant (scores 2 or 3) or nonrelevant (scores 0 or 1).Patients on PPIs had stomach wall uptake more frequently as compared with patients not using PPIs (22 vs. 7%, P=0.017). Dyspepsia was similar in both groups. CONCLUSION: Prolonged use of PPIs is associated with stomach wall uptake of (99m)Tc-tetrofosmin in stress cadmium-zinc-telluride-SPECT images. Gastric symptoms were not associated with stomach wall uptake.


Assuntos
Artefatos , Cádmio , Imagem de Perfusão do Miocárdio , Compostos Organofosforados/metabolismo , Compostos de Organotecnécio/metabolismo , Inibidores da Bomba de Prótons/farmacologia , Estômago/efeitos dos fármacos , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único , Zinco , Idoso , Transporte Biológico/efeitos dos fármacos , Dispepsia/diagnóstico por imagem , Dispepsia/tratamento farmacológico , Dispepsia/metabolismo , Feminino , Mucosa Gástrica/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Inibidores da Bomba de Prótons/uso terapêutico , Estômago/diagnóstico por imagem , Estresse Fisiológico , Fatores de Tempo , Tomografia Computadorizada por Raios X
20.
Eur J Nucl Med Mol Imaging ; 41(5): 956-62, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24310438

RESUMO

PURPOSE: Recently introduced ultrafast cardiac SPECT cameras with cadmium zinc telluride-based (CZT) detectors may provide superior image quality allowing faster acquisition with reduced radiation doses. Although the level of concordance between conventional SPECT and invasive fractional flow reserve (FFR) measurement has been studied, that between FFR and CZT-based SPECT is not yet known. Therefore, we aimed to assess the level of concordance between CZT SPECT and FFR in a large patient group with stable coronary artery disease. METHODS: Both invasive FFR and myocardial perfusion imaging with a CZT-based SPECT camera, using Tc-tetrofosmin as tracer, were performed in 100 patients with stable angina and intermediate grade stenosis on invasive coronary angiography. A cut-off value of <0.75 was used to define abnormal FFR. RESULTS: The mean age of the patients was 64 ± 11 years, and 64 % were men. SPECT demonstrated ischaemia in 31 % of the patients, and 20 % had FFR <0.75. The concordance between CZT SPECT and FFR was 73 % on a per-patient basis and 79 % on a per-vessel basis. Discordant findings were more often seen in older patients and were mainly (19 %) the result of ischaemic SPECT findings in patients with FFR ≥ 0.75, whereas only 8 % had an abnormal FFR without ischaemia as demonstrated by CZT SPECT. CONCLUSION: Only 20 - 30 % of patients with intermediate coronary stenoses had significant ischaemia as assessed by CZT SPECT or invasive FFR. CZT SPECT showed a modest degree of concordance with FFR, which is comparable with previous results with conventional SPECT. Further investigations are particularly necessary in patients with normal SPECT and abnormal FFR, especially to determine whether these patients should undergo revascularization.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Doença da Artéria Coronariana/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Idoso , Cádmio , Feminino , Câmaras gama , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Organofosforados , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Telúrio , Zinco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA