1.
Arch Orthop Trauma Surg ; 144(6): 2795-2802, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38819459

RESUMO

BACKGROUND: Many different regimes of intravenous and local tranexamic acid (TXA) reduce total blood loss (TBL) in patients undergoing total knee arthroplasty (TKA). However, the most effective TXA regime in reducing blood loss might not be most beneficial for the patient. The aim of the present study was to investigate the effect of commonly used TXA regimes on blood loss and on early clinical outcomes. METHODS: We performed this monocentric retrospective study in patients undergoing primary TKA. Primary outcome was the estimated TBL. Secondary outcomes were the rates of adverse events (AE) as well as the range of motion (ROM), mobility and pain intensity during the first three physiotherapy sessions (PTS). RESULTS: We analysed the data of 1250 TKAs. 5 different TXA regimes were applied. TBL (mean ± SE) was 953 ± 64 ml (2xiv), 999 ± 19 ml (2xiv + 1xlocal), 1075 ± 19 ml (1xiv + 1xlocal), 1191 ± 39 ml (1xlocal) and 1241 ± 48 ml (1xiv) (p < 0.01). In the linear regression model for TBL a lower number of TXA applications was a predictor for increased blood loss (p < 0.01). AE rates were lowest under 2xiv (0%) and 2xiv + 1xlocal (4.8%). Highest mobility and lowest pain intensity were observed under 1x iv and 2x iv. The largest portions of fully mobile patients on day three were observed under 1xiv (100%), 2xiv (100%) and 2xiv + 1local TXA (86.9%). CONCLUSION: Our results suggest that multiple applications of TXA are more effective in decreasing blood loss than excessive dosing of TXA. Interestingly, local use of TXA might be associated with higher pain intensity and decreased mobility on the first days after surgery.


Assuntos
Antifibrinolíticos , Artroplastia do Joelho , Perda Sanguínea Cirúrgica , Ácido Tranexâmico , Humanos , Ácido Tranexâmico/administração & dosagem , Ácido Tranexâmico/uso terapêutico , Artroplastia do Joelho/métodos , Estudos Retrospectivos , Perda Sanguínea Cirúrgica/prevenção & controle , Masculino , Antifibrinolíticos/administração & dosagem , Antifibrinolíticos/uso terapêutico , Feminino , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Amplitude de Movimento Articular/efeitos dos fármacos
2.
J Arthroplasty ; 39(7): 1714-1718, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38244639

RESUMO

BACKGROUND: Aseptic loosening is the most common mode of failure after total knee arthroplasty. Despite this, the diagnosis often remains challenging and mainly relies on imaging modalities. Until today, no biomarker exists to aid in diagnosing loosening of the implants. As zirconium (Zr) is often found in bone cement, where it serves as radiopacifier, this study aimed to establish Zr as a synovial biomarker for loosened cemented knee prostheses. METHODS: A total of 31 patients scheduled for revision of a cemented knee prostheses were included. In all patients, the initial used cement contained Zr. After arthrotomy, specimens of synovial fluid were taken and levels of Zr were measured by inductively coupled plasma mass spectrometry. Depending on the necessary amount of force for explantation, the implants were graded "loose" or "well-fixed". Preoperative radiographs were evaluated by 2 independent physicians. RESULTS: The concentration of Zr in the synovial fluid differed significantly (P < .001) between the "loose" (mean 170.9 µg/L, range 0 to 1941 µg/L) and the "well-fixed" (mean 0.6 µg/L, range 0 to 6 µg/L) implants. The receiver operating characteristic analysis revealed 0.25 µg/l as an optimal cutoff value leading to a sensitivity of 0.84, a specificity of 0.92, a positive predictive value of 0.94, and a negative predictive value of 0.79. There was no significant difference in the diagnostic performance compared to radiographs (P = .66). CONCLUSIONS: Zirconium proved to be a reliable novel synovial biomarker for diagnosing aseptic loosening of knee prothesis fixed with cement containing Zr. This biomarker should not be interpreted in isolation, but in combination with existing diagnostic tools.


Assuntos
Artroplastia do Joelho , Biomarcadores , Cimentos Ósseos , Prótese do Joelho , Falha de Prótese , Líquido Sinovial , Zircônio , Humanos , Zircônio/química , Idoso , Masculino , Feminino , Biomarcadores/análise , Líquido Sinovial/química , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Reoperação , Articulação do Joelho/cirurgia , Articulação do Joelho/diagnóstico por imagem
3.
Eur J Radiol ; 167: 111055, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37632998

RESUMO

PURPOSE: Leg torsion analysis can provide valuable information in symptomatic patients after total knee arthroplasty. However, extensive beam-hardening and photon-starvation artifacts limit diagnostic assessability and dose reduction potential. For this study, we investigated the reproducibility of rotational measurements in ultra-low-dose photon-counting CT with spectral shaping via tin prefiltration. MATERIAL AND METHODS: Employing a first-generation photon-counting CT, eight cadaveric specimens were examined with an established three-level scan protocol (hip: Sn 140, knee: Sn 100, ankle: Sn 100 kVp). In three body donors with unilateral knee endoprostheses, additional modified settings were applied (Sn 140 kVp at knee level). Protocols were executed with three dose levels (hip-knee-ankle, high-quality: 5.0-3.0-2.0 mGy, low-dose: 0.80-0.30-0.26 mGy, ultra-low-dose: 0.25-0.06-0.06 mGy). Six radiologists performed torsion analyses, additionally reporting their diagnostic confidence. Intraclass correlation coefficients (ICC) were calculated to assess interrater reliability. RESULTS: No significant differences were ascertained for femoral (p = 0.330), tibial (p = 0.177), and overall leg rotation measurements (p = 0.358) among high-quality, low-dose, and ultra-low-dose protocols. Interrater reliability was excellent for torsion of the femur (ICC 0.915, 95% confidence interval 0.871-0.947), tibia (0.960, 0.938-0.976), and overall leg (0.967, 0.945-0.981). In specimens with total knee endoprostheses, absolute rotational measurements were unaffected by dose level and tube voltage despite superior diagnostic confidence on the ipsilateral and contralateral sides with modified settings (p < 0.001). CONCLUSIONS: Combining the advantages of photon-counting CT and spectral shaping, reliable leg torsion analyses are feasible with ultra-low radiation exposure even in the presence of total knee endoprostheses.


Assuntos
Extremidade Inferior , Tomografia Computadorizada por Raios X , Humanos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Articulação do Joelho/cirurgia , Próteses e Implantes
4.
Oper Orthop Traumatol ; 35(3-4): 146-153, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37179255

RESUMO

OBJECTIVE: Two-stage exchange with implantation of a temporary spacer is the gold standard treatment for chronic periprosthetic joint infection of the hip. This article describes a simple and safe technique for handmade spacers at the hip. INDICATION: Periprosthetic joint infection of the hip. Septic arthritis of the native joint. CONTRAINDICATIONS: Known allergy against components of polymethylmethacrylate bone cements. Inadequate compliance for two-stage exchange. Patient unfit to undergo two-stage exchange. Bony defect situation at the acetabulum impeding stable reduction of the spacer. Bone loss at the femur jeopardizing stable fixation of the stem. Soft tissue damage with need for plastic temporary vacuum-assisted wound closure (VAC) therapy. SURGICAL TECHNIQUE: Tailoring bone cement with antibiotics. Preparation of a metal endoskeleton. Molding of spacer stem and head by hand. Customizing spacer off-sets to bony anatomy and soft tissue tension. Implantation assuring rotational stability at the femur with a bone cement collar. Confirmation of correct position by intraoperative radiography. POSTOPERATIVE MANAGEMENT: Restricted weight-bearing. Range of motion as possible. Reimplantation after successful treatment of infection.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Infecções Relacionadas à Prótese , Humanos , Artroplastia de Quadril/métodos , Cimentos Ósseos/uso terapêutico , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/cirurgia , Resultado do Tratamento , Reoperação/métodos , Antibacterianos , Artrite Infecciosa/diagnóstico , Artrite Infecciosa/cirurgia , Estudos Retrospectivos
5.
J Clin Med ; 12(2)2023 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-36675478

RESUMO

Alignment strategies for primary total knee arthroplasty (TKA) have changed significantly over time with a shift towards a more individualized alignment goal. At the same time, computer-assisted surgery (CAS) has gained interest for intraoperative control and accuracy in implant positioning and limb alignment. Despite the often discussed benefits and drawbacks of robotics and navigation for TKA, the routine use of these new devices on a day-to-day basis remains obscure. Therefore, nationwide hospital billing data based on the Operation Procedure Classification System (OPS) were retrieved from the Federal Statistical Office of Germany for the period from 2010 to 2021. OPS codes for primary total knee arthroplasty (OPS code: 5-822*) were further analyzed regarding the usage of computer navigation (additional OPS code: 5-988) or robotic devices (additional OPS code: 5-987). Gender and age at the time of surgery were also assessed. The results show a total of 2,226,559 primary TKAs were implanted between 2010 and 2021, of which 2,044,914 were performed conventionally (91.84% of all TKAs). A total of 170,276 TKAs were performed using navigation technique (7.65% of all TKAs) and another 11,369 TKAs were performed using robotics (0.51% of all TKAs). For the period from 2018 to 2021, a substantial increase in robot-assisted TKA (R-TKA) was observed, with an average increase rate of 84.74% per year, while the number of navigated TKAs declined (-3.67% per year). Computer-assisted surgery, and particularly robotics for TKA, are seeing growing popularity and stepwise translation into routine clinical use in Germany, with a steep increase rate of more than 80% per year since 2018. Nevertheless, the majority of TKAs are still performed using manual instrumentation, rendering conventional TKA the currently unchanged gold standard.

6.
Artigo em Inglês | MEDLINE | ID: mdl-36673964

RESUMO

Medical tourism is a rapidly growing sector of economic growth and diversification. However, data on the demographics and characteristics of the traveling patients are sparse. In this study, we analyzed the common demographic properties and characteristics of the inbound medical tourists seeking orthopedic medical care in Germany for the years 2010 to 2019 compared to a domestic group. At the same time, we examined how the COVID-19 pandemic outbreak of 2020 changed the field of medical tourism in Germany. Calculations were performed using administrative hospital data provided by the Federal Statistical Department of Germany. Data were analyzed from the years 2010 to 2020. A total of six elective orthopedic surgery codes (bone biopsy, knee arthroplasty, foot surgery, osteotomy, hardware removal, and arthrodesis) were identified as key service indicators for medical tourism and further analyzed. Factors including residence, sex, year, and type of elective surgery were modeled using linear regression analysis. Age and sex distributions were compared between patients living inside Germany (DE) or outside Germany (non-DE). Between 2010 and 2020, 6,261,801 orthopedic procedures were coded for the DE group and 27,420 key procedures were identified for the non-DE group. Medical tourists were predominantly male and significantly younger than the domestic population. The linear regression analysis of the OPS codes over the past years showed a significantly different slope between the DE and non-DE groups only for the OPS code "hardware removal". With the COVID-19 pandemic, an overall decline in performed orthopedic procedures was observed for the non-DE and the DE group. A significant reduction below the 95% prediction bands for the year 2020 could be shown for hardware removal and foot surgery (for DE), and for hardware removal, knee arthroplasty, foot surgery, and osteotomy (for non-DE). This study is the first to quantify inbound medical tourism in elective orthopedic surgery in Germany. The COVID-19 pandemic negatively affected many-but not all-areas of orthopedic surgery. It has to be seen how this negative trend will develop in the future.


Assuntos
COVID-19 , Turismo Médico , Humanos , Masculino , Feminino , COVID-19/epidemiologia , Pandemias , Alemanha/epidemiologia , Demografia
7.
Foot Ankle Surg ; 28(8): 1384-1388, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35872119

RESUMO

BACKGROUND: Therapeutic shoes and partial weight bearing regimes are used after foot surgery to prevent the operated region from excessive load. It remains unclear to which extent partial weight bearing reduces the plantar peak forces. Therefore, we investigated the correlation of weight bearing and plantar peak forces in commonly used therapeutic shoes. METHODS: Three different weight bearing regimes (20 kg, 40 kg, full weight) were investigated in 20 healthy volunteers. Sensor insoles were used to measure peak forces of the forefoot, midfoot, heel and the complete foot using four kind of shoes (bandage shoe, forefoot relief shoe, short walker and standard sneaker). Peak forces were compared between shoes using one-way ANOVA. The influence of partial weight bearing relative to the peak forces was examined by linear regression analysis. RESULTS: All therapeutic shoes reduced significantly peak forces of the fore- and midfoot when compared to the reference shoe; the largest reduction was achieved by the forefoot relief shoe (-70 % at forefoot). Weight load and the resulting peak force showed a positive linear correlation for all regions and shoe types. Partial weight bearing significantly reduced the forefoot's force ratio compared to full weight bearing for all shoes except the forefoot relief shoe. CONCLUSIONS: Partial weight bearing is a strong instrument to reduce plantar peak forces of the forefoot, additionally to the proven offloading effect of therapeutic shoes.


Assuntos
Antepé Humano , Suporte de Peso Parcial , Humanos , Antepé Humano/cirurgia , Pressão , Sapatos , Pé/cirurgia , Caminhada
8.
Biomed Res Int ; 2021: 8442435, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34840982

RESUMO

PURPOSE: Contradicting definitions of periprosthetic joint infection (PJI) are in use. Joint aspiration is performed before total hip arthroplasty (THA) revision. This study investigated the influence of PJI definition on PJI prevalence at THA revision. Test quality of prerevision aspiration was evaluated for the different PJI definitions. METHODS: 256 THA revisions were retrospectively classified to be infected or not infected. Classification was performed according to the 4 different definitions proposed by the Musculoskeletal Infection Society (MSIS), the Infectious Diseases Society of America (IDSA), the International Consensus Meeting (ICM), and the European Bone and Joint Infection Society (EBJIS). Only chronic PJIs were included. RESULTS: PJI prevalence at revision significantly correlated with the applied PJI definition (p = 0.01, Cramer's V = 0.093). PJI prevalence was 20.7% for the MSIS, 25.4% for the ICM, 28.1% for the IDSA, and 32.0% for the EBJIS definition. For synovial fluid white blood cell count, the best ROC-AUC for predicting PJI was 0.953 in combination with the MSIS definition. CONCLUSION: PJI definition significantly influences the rate of diagnosed PJIs at THA revision. Synovial fluid white blood cell count is a reliable means to rule out PJI. In cases with a borderline high synovial white blood cell count before THA revision as the only sign of chronic PJI, an extended diagnostic work-up should be considered.


Assuntos
Artroplastia de Quadril/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Reoperação/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artrite Infecciosa/diagnóstico , Artrite Infecciosa/epidemiologia , Artrite Infecciosa/etiologia , Doença Crônica , Feminino , Alemanha , Prótese de Quadril/efeitos adversos , Prótese de Quadril/microbiologia , Humanos , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Paracentese , Prevalência , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Estudos Retrospectivos , Líquido Sinovial/citologia , Líquido Sinovial/microbiologia , Adulto Jovem
9.
J Arthroplasty ; 36(11): 3686-3691, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34284936

RESUMO

BACKGROUND: Mobilization on the day of surgery after total hip arthroplasty (THA) is widely used. However, elderly, obese and severely diseased patients are often excluded from early mobilization. Therefore, it was our aim to investigate the effect of mobilization on the day of surgery with focus on these patients. METHODS: 167 patients underwent THA via direct anterior approach. Exclusion criterion was the use of wound drainage. The patients were randomly allocated to two groups. Day 0 group was mobilized 4 hours after surgery, day 1 group the day after surgery. Primary outcome was the time to readiness for discharge (TRD). Secondary outcome was the occurrence of adverse events (vertigo, nausea, vomiting, severe pain) on the day of surgery. Group comparisons were calculated with respect to elderly (age ≥75 years), obese (BMI ≥30 kg/m2) and severely diseased patients (ASA≥3). RESULTS: TRD was shorter in day 0 group (3.25 vs 3.99 days, P < .01). The rate of adverse events on the day of surgery was similar in both groups (0.28 vs 0.25, P = .73). TRD differences were higher within all subgroups (3.85vs4.81; 3.25vs4.39; 4.08vs5.11days) while the rate of immediate adverse events was reduced (0.15vs0.24; 0.25vs0.3; 0.25vs0.33). Within 90 days 3 patients of group 0 underwent revision surgery, none of group 1 (P = .12). CONCLUSION: Mobilization on the day of surgery reduces the TRD without increasing the rate of immediate adverse events, regardless of age, BMI and ASA score. Future studies are needed to investigate if early mobility increases the 90-days complication rate.


Assuntos
Artroplastia de Quadril , Idoso , Artroplastia de Quadril/efeitos adversos , Deambulação Precoce , Humanos , Obesidade/complicações , Reoperação , Estudos Retrospectivos
10.
J Orthop ; 24: 34-41, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33679026

RESUMO

BACKGROUND: Aiming at an early identification of patients with an unsatisfactory outcome after hip arthroplasty we investigated the pre-, intra- and early postoperative predictability. METHODS: Using logistic regression models at nine different time points we calculated the area under the curve of the receiver operating characteristic (ROC-AUC) to compare the predictability of an unsatisfactory outcome. RESULTS: The predictability of unsatisfactory outcomes increased significantly from a ROC-AUC (95% CI) of 0.73 (0.62-0.84) in the preoperative setting to 0.85 (0.77-0.94) on day 2 after surgery. CONCLUSION: Most of the patients with unsatisfactory outcomes can be identified during the first days after surgery.

11.
BMC Musculoskelet Disord ; 21(1): 297, 2020 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-32404085

RESUMO

BACKGROUND: While multiple in vitro studies examined mesenchymal stromal cells (MSCs) derived from bone marrow or hyaline cartilage, there is little to no data about the presence of MSCs in the joint capsule or the ligamentum capitis femoris (LCF) of the hip joint. Therefore, this in vitro study examined the presence and differentiation potential of MSCs isolated from the bone marrow, arthritic hyaline cartilage, the LCF and full-thickness samples of the anterior joint capsule of the hip joint. METHODS: MSCs were isolated and multiplied in adherent monolayer cell cultures. Osteogenesis and adipogenesis were induced in monolayer cell cultures for 21 days using a differentiation medium containing specific growth factors, while chondrogenesis in the presence of TGF-ß1 was performed using pellet-culture for 27 days. Control cultures were maintained for comparison over the same duration of time. The differentiation process was analyzed using histological and immunohistochemical stainings as well as semiquantitative RT-PCR for measuring the mean expression levels of tissue-specific genes. RESULTS: This in vitro research showed that the isolated cells from all four donor tissues grew plastic-adherent and showed similar adipogenic and osteogenic differentiation capacity as proven by the histological detection of lipid droplets or deposits of extracellular calcium and collagen type I. After 27 days of chondrogenesis proteoglycans accumulated in the differentiated MSC-pellets from all donor tissues. Immunohistochemical staining revealed vast amounts of collagen type II in all differentiated MSC-pellets, except for those from the LCF. Interestingly, all differentiated MSCs still showed a clear increase in mean expression of adipogenic, osteogenic and chondrogenic marker genes. In addition, the examination of an exemplary selected donor sample revealed that cells from all four donor tissues were clearly positive for the surface markers CD44, CD73, CD90 and CD105 by flow cytometric analysis. CONCLUSIONS: This study proved the presence of MSC-like cells in all four examined donor tissues of the hip joint. No significant differences were observed during osteogenic or adipogenic differentiation depending on the source of MSCs used. Further research is necessary to fully determine the tripotent differentiation potential of cells isolated from the LCF and capsule tissue of the hip joint.


Assuntos
Adipogenia/genética , Células da Medula Óssea/metabolismo , Cartilagem Hialina/patologia , Cápsula Articular/patologia , Células-Tronco Mesenquimais/metabolismo , Osteoartrite do Quadril/patologia , Ligamento da Cabeça do Fêmur/patologia , Adulto , Antígenos CD/metabolismo , Artroplastia de Quadril , Células Cultivadas , Condrogênese/genética , Feminino , Expressão Gênica , Humanos , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Osteogênese/genética , Doadores de Tecidos
12.
Cancer Invest ; 35(8): 562-568, 2017 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-28799812

RESUMO

The aim of this study was to evaluate the prevalence of vitamin D deficiency in patients with different types of bone tumors and to elucidate whether or not there are differences in prediagnostic vitamin D levels in patients with malignant compared to benign bone tumors. Prediagnostic serum 25(OH)D levels of 105 consecutive patients that presented with bone tumors and tumor-like lesions to two Orthopedic Level I University Centers in Germany between 2011 and 2016 were measured on admission. We found an alarming and widespread rate of vitamin D deficiency in patients with bone tumors. Specifically, 83% of all patients had low vitamin D levels with a mean 25(OH)D level of 19.82 ng/ml. Notably, patients diagnosed with malignant bone tumors had significantly lower vitamin D levels compared to patients with benign bone lesions (p = 0.0008). In conclusion, it is essential to assess vitamin D levels in patients with tumors involving bone. In addition, there might be an association between vitamin D deficiency and the onset or course of primary malignant bone tumors.


Assuntos
25-Hidroxivitamina D 2/sangue , Neoplasias Ósseas/complicações , Deficiência de Vitamina D/epidemiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Fatores de Risco , Adulto Jovem
13.
Somatosens Mot Res ; 34(2): 139-144, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28675953

RESUMO

INTRODUCTION: The nociceptive flexion reflex threshold (NFRT) is a promising tool to monitor analgesia during general anaesthesia. Clinical studies have shown that the NFRT allows to predict movement responses to painful stimuli under a combined anaesthetic regime of sedative and opioid agents. Experimental studies indicated that the NFRT is also able to predict such movement responses under an exclusively sedative regime like propofol mono-anaesthesia. Therefore, we performed this study to investigate the ability of the NFRT to predict movement responses to painful stimuli in patients during a clinical propofol mono-anaesthesia. METHODS: We investigated 140 cardiac surgery patients during their postoperative phase under propofol mono-anaesthesia. NFRT and bispectral index (BIS) were determined in each patient right before endotracheal suctioning or painful electrical test stimulation. Prediction probabilities were calculated to quantify how accurate each measure is able to predict movement responses to the stimuli. RESULTS: The 124 patients included in the analysis received a median propofol dosage of 3.2 (2.5-3.9) [median (IQR)] mg/kg/h. The included patients showed 287 movement responses after a total of 725 investigated stimuli. The prediction probabilities for positive movement responses were 0.63 (95%CI: 0.59-0.67) for the NFRT and 0.69 (95%CI: 0.65-0.73) for the BIS. CONCLUSIONS: The NFRT allows the prediction of movement responses under propofol mono-anaesthesia, which confirms its utility as a monitor to predict movement responses under general anaesthesia. The BIS allows an even more accurate prediction, although it does not reflect the physiological structures of movement suppression, but correlates closely with the dose of propofol. TRIAL REGISTRATION: German clinical trial register (DRKS00003062, Deutsches Register Klinischer Studien).


Assuntos
Anestesia Geral , Movimento/efeitos dos fármacos , Propofol , Reflexo/efeitos dos fármacos , Monitores de Consciência , Estimulação Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento/fisiologia , Dor , Reflexo/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA