Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur J Orthop Surg Traumatol ; 27(7): 909-915, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28501962

RESUMO

PURPOSE: To assess the long-term results of trapeziometacarpal arthrodesis using a quadrangular plate, regarding clinical, radiological and functional outcomes, as well as development of complications. MATERIAL AND METHOD: From 2005 to 2015, 70 patients were treated at our institution for primary osteoarthrosis of thumb carpometacarpal joint performing a trapeziometacarpal arthrodesis. A total of 85 arthrodesis were carried out using a titanium quadrangular plate (Proflyle plate, Stryker®, Kalamazoo MI, USA), without grafting in any case. Pre- and postoperative functional data were assessed at the outpatient clinics using DASH, MWS and VAS. All patients were asked for their ability to perform basic daily activities before and after surgery. All patients were also asked about satisfaction and their return to their jobs after surgery. Pre- and postoperative radiological data were also assessed. RESULTS: There were 59 females and 11 males with an average age of 55 years (range 44-60). In 66 cases arthrodesis was carried out in the dominant hand, in 45 cases the right thumb was involved, and in 40 the left thumb was involved; in 15 cases arthrodesis was carried out bilaterally. Preoperative average DASH score was 64 (range 50-85), postoperative average score was 25 (range 5-61). Regarding MWS, 51 patients obtained excellent results, 15 patients obtained good results and 4 patients referred poor results. The preoperative average score of VAS was 6 (range 5-10), which decrease to an average of 2 (range 0-3) after surgery; all those differences were statistically significant. All patients reported a mild loss of motion; however, all of them reported improvement to carry out daily activities. There were four cases of nonunion because of failure of fixation and two cases with dysesthetic scar. There was no development of osteoarthritis in adjacent joints. The average follow-up was 60 months. CONCLUSIONS: The use of quadrangular plates for arthrodesis of the trapeziometacarpal joint is a safety and reproducible technique with a low rate of complications. Arthrodesis decreases pain and improves function in patients with primary osteoarthritis of the thumb carpometacarpal joint; in spite of a mild loss of motion, patients are satisfied with this procedure.


Assuntos
Artrodese/instrumentação , Placas Ósseas , Articulações Carpometacarpais/cirurgia , Osteoartrite/cirurgia , Polegar/cirurgia , Atividades Cotidianas , Adulto , Artrodese/métodos , Articulações Carpometacarpais/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/diagnóstico por imagem , Osteoartrite/fisiopatologia , Satisfação do Paciente , Radiografia , Amplitude de Movimento Articular/fisiologia , Polegar/diagnóstico por imagem
2.
J Arthroplasty ; 31(7): 1539-43, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27038861

RESUMO

BACKGROUND: Secondary patellar resurfacing (SPR) is a procedure that can be used in patients with persistent anterior knee pain (AKP) after a primary total knee arthroplasty. The aim of our study was to analyze the clinical and functional outcomes as well as the complications of this procedure and identify predictive factors for a favorable outcome. METHODS: Forty-six patients who underwent SPR for persistent AKP after primary total knee arthroplasty were retrospectively studied. The patient's mean age was 68 years (range, 36-86 years). The average follow-up time after SPR was 74 months (range, 24-197 months). Demographic data, Knee Society Score scale, range of motion, pain improvement (Visual Analogue Scale), overall satisfaction, and complications were recorded. The statistical analysis was performed using STATA tm/SE v10. RESULTS: There was an improvement of the Knee Society scale (from 54 ± 11 to 64 ± 16 points; P < .05). However, in 59% of the cases, there was no pain improvement, and 65% of patients were not satisfied. Four patients showed complications, and in 2 cases, reoperation was necessary. We did not find any preoperative predictive factor for a favorable outcome after SPR. CONCLUSION: Despite improvement of the Knee Society scale, many patients continue with AKP and are dissatisfied with this procedure; therefore, we do not recommend it in this clinical scenario.


Assuntos
Artroplastia do Joelho/efeitos adversos , Articulação do Joelho/cirurgia , Patela/cirurgia , Síndrome da Dor Patelofemoral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artralgia/cirurgia , Artroplastia do Joelho/métodos , Dor Crônica/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Dor Pós-Operatória/cirurgia , Síndrome da Dor Patelofemoral/etiologia , Satisfação do Paciente , Reoperação/efeitos adversos , Estudos Retrospectivos
3.
Acta Orthop Belg ; 73(1): 60-9, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17441660

RESUMO

The Locking Compression Plate (LCP) and the Less Invasive Stabilisation System (LISS) are new implants with angular stability developed by the AO/ASIF. They offer an alternative for internal fixation in complex intra-articular fractures and high-energy diaphyseal fractures of the long bones. The new system was used in a prospective study to treat 113 patients (76 women, 37 men; average age: 53.1 years) with 122 injuries (multifragment shaft fractures or complex intra-articular, delayed/ non-union, malunion) from October 2002. Of these, 13 affected the humerus, 20 the radius, 2 the ulna, 21 the femur, 42 the tibia, 10 the fibula, 2 the acetabulum and 12 the calcaneus. Because of severe concomitant injuries, 18 fractures were first treated with an external fixator and definitively stabilised more than two weeks after the injury. Thirty-one patients were operated on after failure of other implants and non-union. Clinical and radiographic findings as well as complications were followed prospectively over a mean period of 20 months (range: 13 to 30). One patient was lost to follow-up. A total of 112 patients underwent a standardised follow-up examination. The outcome correlated with the severity of the fracture, anatomic reduction, adequate positioning of the plate and concomitant injuries. Despite the large number of open and comminuted fractures, no serious complications such as deep infections, vascular lesions, deep venous thrombosis or non-unions were noted. We found the new internal fixator system to be a safe and reliable procedure. It offers numerous fixation possibilities and has proven its value in complex fracture situations and in revision operations. A good knowledge of biomechanics is essential as well as precise preoperative planning.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Fixadores Internos , Acetábulo/lesões , Adulto , Idoso , Idoso de 80 Anos ou mais , Calcâneo/lesões , Diáfises/lesões , Feminino , Fraturas do Fêmur/cirurgia , Fíbula/lesões , Seguimentos , Fraturas Cominutivas/cirurgia , Fraturas Mal-Unidas/cirurgia , Fraturas Expostas/cirurgia , Fraturas não Consolidadas/cirurgia , Humanos , Fraturas do Úmero/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fraturas do Rádio/cirurgia , Reoperação , Fraturas da Tíbia/cirurgia , Resultado do Tratamento , Fraturas da Ulna/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA