Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Arthroplasty ; 39(6): 1569-1576, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749600

RESUMO

BACKGROUND: Periprosthetic joint infection (PJI) after total knee arthroplasty (TKA) is a devastating complication. Intrawound vancomycin powder has been shown to reduce infection rates in spine surgery, but its role in arthroplasty remains controversial. This prospective randomized control trial aimed to evaluate the efficacy of intrawound vancomycin in preventing PJI after primary TKA. METHODS: A total of 1,022 patients were randomized to the study group (n = 507, who received 2 grams intrawound vancomycin powder before arthrotomy closure) or to the control group (n = 515, no local vancomycin) with a minimum follow-up of 12-months. The primary outcome was the incidence of PJI or surgical site infection (SSI). Secondary outcomes included associated minor complications such as stitch abscess, persistent wound drainage, and delayed stitch removal. Other parameters evaluated include reoperation rates and incidences of nephrotoxicity. RESULTS: The overall infection rate in 1,022 patients was 0.66%. There was no significant difference in PJI rate in the study group (N = 1; 0.2%) versus the control group (N = 3; 0.58%), P = .264. Reoperation rates in the study group (N = 4; 0.78%) and control (N = 5; 0.97%), and SSI rates in the study (N = 1; 0.2%) and control groups (N = 2; 0.38%) were comparable. The Vancomycin cohort, however, demonstrated a significantly higher number of minor wound complications (n = 67; 13.2%) compared to the control group (n = 39; 7.56%, P < .05). Subgroup analysis showed diabetics in the study group to also have a higher incidence of minor wound complications (24 [14.1%] versus 10 [6.2%]; P < 05]. Multivariate analyses found that vancomycin use (odds ratio = 1.64) and smoking (odds ratio = 1.85) were associated with an increased risk of developing minor wound complications. No cases of nephrotoxicity were reported. CONCLUSIONS: Intrawound vancomycin powder does not appear to reduce PJI/SSI rate in primary total knee arthroplasties, including high-risk groups. Although safe from a renal perspective, intrawound vancomycin was associated with an increase in postoperative aseptic wound complications. Intrawound vancomycin may not be effective in reducing the rate of PJI in primary TKA.


Assuntos
Antibacterianos , Artroplastia do Joelho , Infecções Relacionadas à Prótese , Infecção da Ferida Cirúrgica , Vancomicina , Humanos , Vancomicina/administração & dosagem , Vancomicina/uso terapêutico , Artroplastia do Joelho/efeitos adversos , Masculino , Feminino , Infecções Relacionadas à Prótese/prevenção & controle , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/epidemiologia , Idoso , Estudos Prospectivos , Pessoa de Meia-Idade , Método Duplo-Cego , Antibacterianos/administração & dosagem , Infecção da Ferida Cirúrgica/prevenção & controle , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/epidemiologia , Resultado do Tratamento , Reoperação/estatística & dados numéricos , Prótese do Joelho/efeitos adversos , Antibioticoprofilaxia/métodos
2.
Eur J Orthop Surg Traumatol ; 34(5): 2245-2254, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38630298

RESUMO

The use of whole-body cryotherapy (WBC) for musculoskeletal ailments is growing. WBC, involving brief exposure to extremely low temperatures, is increasingly used for its analgesic, anti-inflammatory, and antioxidant effects. The paper examines the physiological impacts of WBC on cardiovascular, musculoskeletal, hematologic, hormonal, and metabolic systems. Specific orthopaedic applications discussed include its role in the management of fractures, osteoarthritis, osteonecrosis of the femoral head, osteomyelitis, adhesive capsulitis, tendinopathies, rheumatic pathologies, chronic pain syndromes, and fibromyalgia. The study also highlights the benefits and drawbacks of WBC, including its potential to improve athletic performance, recovery, mood, and well-being, while noting risks like frostbite and impaired muscle strength. Clinical evidence from various studies is evaluated, revealing a spectrum of outcomes. For instance, WBC shows promise in enhancing bone health in athletes and providing relief in osteoarthritis and fibromyalgia patients. However, evidence for its efficacy in conditions like chronic pain syndromes and osteomyelitis is less robust. The paper underscores the need for further research to establish standardised protocols and understand long-term effects. While WBC offers significant benefits in orthopaedics, understanding its limitations and potential risks is crucial for its safe and effective clinical application.


Assuntos
Crioterapia , Doenças Musculoesqueléticas , Humanos , Crioterapia/métodos , Doenças Musculoesqueléticas/terapia
3.
J Robot Surg ; 18(1): 188, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38683271

RESUMO

Robotic-assisted total knee arthroplasty (RATKA) has been shown to achieve more accurate component positioning and target alignment than conventional jig-based instrumentation; however, concerns remain regarding its adoption since it is associated with steep learning curves, higher operational costs, and increased surgical time. This study aims to compare the operating times of three cohorts of patients undergoing simultaneous bilateral TKA, i.e., first 50 RATKA, last 50 RATKA (at the end of 1 year), and 50 conventional TKA. This prospective cohort study was conducted at a single high-volume tertiary care center by a single experienced surgeon on 150 patients (300 knees), who were allotted into three equal cohorts of 50, between February 2020 and December 2021. Simultaneous bilateral TKAs were done in all three groups and operative times recorded. We describe the technique for optimizing the surgical time of SB-RATKA for efficient operative room logistics. The operating times of the two robotic-assisted TKA cohorts were compared with the operating times of the conventional SB-TKA cohort. The mean age of the study population was 59(±6.2) years with the majority of females (82%). The mean coronal deformity was comparable between the cohorts. The mean operating time in the conventional CTKA, initial 50 RATKA, and final 50 RATKA cohorts were 115.56 (±10.7), 127.8 (±26), and 91.66 (±13.5) min, respectively, all of which showed a statistically significant difference (p < 0.001). The mean operating times of the final 50 RATKA at the end of 1 year improved by about 36 min with all the SB-RATKA cases being completed in under 120 min. The efficiency of SB-RATKA improved significantly with time and experience, resulting in shorter operational times within a year, revealing the potential of robotic-assisted surgery to surpass conventional approaches in TKA in terms of operating room efficiency.


Assuntos
Artroplastia do Joelho , Salas Cirúrgicas , Duração da Cirurgia , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/estatística & dados numéricos , Artroplastia do Joelho/métodos , Estudos Prospectivos , Pessoa de Meia-Idade , Feminino , Masculino , Estudos de Coortes , Cirurgiões/estatística & dados numéricos , Idoso
4.
J Robot Surg ; 17(6): 2919-2927, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37831402

RESUMO

This study aimed to compare two alignment strategies in the same patient undergoing simultaneous bilateral robotic-assisted TKA (SB-RATKA): mechanical alignment (MA), the gold-standard, and functional alignment (FA), a balance-driven, personalized alignment strategy. The outcome measures included quantitative assessment of soft-tissue release, incidence of knee balance, and post-operative pain. This was a prospective, self-controlled, randomized-controlled trial involving 72 patients who underwent SB-RATKA using the MAKO® robotic system with comparable grades of deformity and pain in both knees. 65 patients were finally included with one alignment strategy done per knee, with the patients blinded to the strategy used. The study recorded the additional soft-tissue releases required, incidence of pre-balance, and daily post-operative VAS pain scores. The mean age of the study population was 57.95 years, with a female preponderance (N = 53, 81.6%). MA group had significantly more medial compartment tightness in both flexion (MA-15.6 ± 1.8; FA-17 ± 1.3) and extension (MA-14.9 ± 1.9; FA-17 ± 1.1) (p < 0.0001) compared to the FA group after dynamic balancing. 66% of knees in the FA group (N = 43) achieved pre-balance compared to 32.3% in the MA group (N = 21) (p < 0.0001). VAS scores showed a significant reduction in pain in the FA group up to 72 h post-surgery (p < 0.0001). The requirement for posteromedial release (PM), posterior capsular (PC) release, tibial reduction osteotomy (TRO), and superficial MCL pie crusting (sMCL) were significantly lower in FA (PM-22, PC-13, TRO-8, sMCL-2) compared to MA (PM-44, PC-29, TRO-18, sMCL-8). Functional alignment strategy consistently resulted in a higher incidence of knee balance with a significant reduction in soft-tissue releases and immediate post-operative pain when compared to MA in the same patient undergoing SB-RATKA. Therapeutic Level 1.


Assuntos
Artroplastia do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Feminino , Pessoa de Meia-Idade , Artroplastia do Joelho/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Prospectivos , Incidência , Dor Pós-Operatória/epidemiologia , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle
5.
J Orthop Case Rep ; 13(10): 127-131, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37885652

RESUMO

Introduction: Posterior-stabilized (PS) total knee arthroplasty (TKA) prostheses are characterized by an articulation between the polyethylene tibial post and the cam of the femoral component. Tibial post-fractures, traumatic and non-traumatic, are uncommon but catastrophic complications. We report a rare and unusual case of complete atraumatic erosion of the tibial post after PS-TKA. Case Report: We present a case of atraumatic tibial post-failure (complete erosion) in a 73-year-old female after primary TKA. The patient presented with chronic pain, effusion, and instability both in the coronal and sagittal plane over a period of 1 year. There were no signs of component loosening on plain radiography, no fractures, and revealed medial extension laxity on valgus stress views. During revision surgery, polyethylene insert retrieval revealed a completely eroded tibial post, without any obvious fracture. There was no fractured tibial post lying freely in the joint cavity. The patient was subsequently revised with a hinged component due to gross bi-planar instability. Conclusion: In a post-TKR (PS knee) patient with chronic pain and instability, one should consider tibial post-complications after ruling out infection. Chronic instability can cause progressive erosion of the tibial post, which can fail without an obvious fracture. Revision surgery with constrained implants may be needed to manage such cases.

6.
Indian J Orthop ; 57(8): 1196-1202, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37525725

RESUMO

Introduction: SMART sensor technology may provide the solution to bridge the gap between the current radiographic determination of fracture healing and clinical assessment. The displacement and rigidity between the fracture ends can be accurately measured using strain gauges. Progressively increasing stiffness is a sign of fracture consolidation which can be monitored using sensors. The design of standard orthopaedic implants can remain the same and needs no major modifications as the sensor can be mounted onto the implant without occupying much space. Data regarding various fracture morphologies and their strain levels throughout the fracture healing process may help develop AI algorithms that can subsequently be used to optimise implant design/materials. Materials and Methods: The literature search was performed in PubMed, PubMed Central, Scopus, and Web of Science databases for reviewing and evaluating the published scientific data regarding sensor technology in fracture healing. Results and Interpretation: SMART sensor technology comes with a variety of uses such as determining fracture healing progress, predicting early implant failure, and determining fractures liable for non-union to exemplify a few. The main limitations are that it is still in its inception and needs extensive refinement before it becomes widely and routinely used in clinical practice. Nevertheless, with continuous advances in microprocessor technology, research designs, and additive manufacturing, the utilisation and application of SMART implants in the field of trauma and orthopaedic surgery are constantly growing. Conclusion: Mass production of such SMART implants will reduce overall production costs and see its use in routine clinical practice in the future and is likely to make a significant contribution in the next industrial revolution termed 'Industry 5.0' which aims at personalised patient-specific implants and devices. SMART sensor technology may, therefore, herald a new era in the field of orthopaedic trauma.

7.
J Orthop Case Rep ; 12(12): 25-29, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37056587

RESUMO

Introduction: The use of modular implants for revision TKA are ever increasing in number due to their definitive advantage over their monoblock counterparts by providing the surgeon with the versatility needed to achieve equal gaps and manage bone defects. This superiority comes at the cost of certain unique complications attributable to its modular design such as loosening and fractures at the areas of component coupling that are prone to fatigue failure with suboptimal fixation. Case Report: We present a case of modular femoral component failure in a 59-year man of Asian decent after revision TKA secondary to disengagement and migration of the extension stem locking bolt of a Total Condylar-III prosthesis. Patient presented with pain, effusion, and instability 2.5 years after stage-2 revision TKA. Radiographs revealed migration of the femur-stem locking bolt into the joint cavity. The femoral component and stem were loose. The locking bolt was extracted, and he underwent re-revision surgery with revised femoral components. Conclusion: Stem-condylar junction of modern modular TKA implants are prone to early loosening and failure. This diagnosis should be anticipated on serial follow-up radiographs and in patients who complain of sudden onset of instability following revision surgery.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA