Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Phys Med ; 117: 103199, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38142615

RESUMO

Hadron therapy is a radiotherapy modality which offers a precise energy deposition to the tumors and a dose reduction to healthy tissue as compared to conventional methods. However, methods for real-time monitoring are required to ensure that the radiation dose is deposited on the target. The IRIS group of IFIC-Valencia developed a Compton camera prototype for this purpose, intending to image the Prompt Gammas emitted by the tissue during irradiation. The system detectors are composed of Lanthanum (III) bromide scintillator crystals coupled to silicon photomultipliers. After an initial characterization in the laboratory, in order to assess the system capabilities for future experiments in proton therapy centers, different tests were carried out in two facilities: PARTREC (Groningen, The Netherlands) and the CNA cyclotron (Sevilla, Spain). Characterization studies performed at PARTREC indicated that the detectors linearity was improved with respect to the previous version and an energy resolution of 5.2 % FWHM at 511 keV was achieved. Moreover, the imaging capabilities of the system were evaluated with a line source of 68Ge and a point-like source of 241Am-9Be. Images at 4.439 MeV were obtained from irradiation of a graphite target with an 18 MeV proton beam at CNA, to perform a study of the system potential to detect shifts at different intensities. In this sense, the system was able to distinguish 1 mm variations in the target position at different beam current intensities for measurement times of 1800 and 600 s.


Assuntos
Diagnóstico por Imagem , Terapia com Prótons , Método de Monte Carlo , Raios gama , Espanha
2.
Sci Rep ; 11(1): 10414, 2021 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-34001941

RESUMO

This work presents the first tests performed with radiochromic films and a new Micro‒Opto‒Electro-Mechanical system (MOEMS) for in situ dosimetry evaluation in radiotherapy in real time. We present a new device and methodology that overcomes the traditional limitation of time-delay in radiochromic film analysis by turning a passive detector into an active sensor. The proposed system consists mainly of an optical sensor based on light emitting diodes and photodetectors controlled by both customized electronic circuit and graphical user interface, which enables optical measurements directly. We show the first trials performed in a low‒energy proton cyclotron with this MOEMS by using gafchromic EBT3 films. Results show the feasibility of using this system for in situ dose evaluations. Further adaptation is ongoing to develop a full real‒time active detector by integrating MOEM multi‒arrays and films in flexible printed circuits. Hence, we point to improve the clinical application of radiochromic films with the aim to optimize radiotherapy treatment verifications.

3.
Phys Med Biol ; 66(11)2021 05 26.
Artigo em Inglês | MEDLINE | ID: mdl-33853055

RESUMO

In this work we show the first microdosimetry measurements on a low energy proton beam with therapeutic-equivalent fluence rates by using the second generation of 3D-cylindrical microdetectors. The sensors belong to an improved version of a novel silicon-based 3D-microdetector design with electrodes etched inside silicon, which were manufactured at the National Microelectronics Centre (IMB-CNM, CSIC) in Spain. A new microtechnology has been employed using quasi-toroid electrodes of 25µm diameter and a depth of 20µm within the silicon bulk, resulting in a well-defined cylindrical radiation sensitive volume. These detectors were tested at the 18 MeV proton beamline of the cyclotron at the National Accelerator Centre (CNA, Spain). They were assembled into an in-house low-noise readout electronics to assess their performance at a therapeutic-equivalent fluence rate. Microdosimetry spectra of lineal energy were recorded at several proton energies starting from 18 MeV by adding 50µm thick tungsten foils gradually at the exit-window of the cyclotron external beamline, which corresponds to different depths along the Bragg curve. The experimentalyF¯values in silicon cover from (5.7 ± 0.9) to (8.5 ± 0.4) keV µm-1in the entrance to (27.4 ± 2.3) keV µm-1in the distal edge. Pulse height energy spectra were crosschecked with Monte Carlo simulations and an excellent agreement was obtained. This work demonstrates the capability of the second generation 3D-microdetectors to assess accurate microdosimetric distributions at fluence rates as high as those used in clinical centers in proton therapy.


Assuntos
Terapia com Prótons , Silício , Método de Monte Carlo , Prótons , Radiometria
4.
Phys Med Biol ; 65(24): 245027, 2020 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-33120374

RESUMO

The IRIS group at IFIC Valencia is developing a three-layer Compton camera for treatment monitoring in proton therapy. The system is composed of three detector planes, each made of a [Formula: see text] monolithic crystal coupled to a SiPM array. Having obtained successful results with the first prototype (MACACO) that demonstrated the feasibility of the proposed technology, a second prototype (MACACO II) with improved performance has been developed, and is the subject of this work. The new system has an enhanced detector energy resolution which translates into a higher spatial resolution of the telescope. The image reconstruction method has also been improved with an accurate model of the sensitivity matrix. The device has been tested with high energy photons at the National Accelerator Centre (CNA, Seville). The tests involved a proton beam of 18 MeV impinging on a graphite target, to produce 4.4 MeV photons. Data were taken at different system positions of the telescope with the first detector at 65 and 160 mm from the target, and at different beam intensities. The measurements allowed successful reconstruction of the photon emission distribution at two target positions separated by 5 mm in different telescope configurations. This result was obtained both with data recorded in the first and second telescope planes (two interaction events) and, for the first time in beam experiments, with data recorded in the three planes (three interaction events).


Assuntos
Fótons , Terapia com Prótons/métodos , Estudos de Viabilidade , Humanos , Terapia com Prótons/instrumentação , Telescópios
5.
Appl Radiat Isot ; 67(5): 884-8, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19261483

RESUMO

In-vitro leaching of radioactive 'hot' particles isolated from soils sampled at the Semipalatinsk Nuclear Test Site has been carried out in order to evaluate the fraction of plutonium activity released into simulated human stomach and small intestine fluids during digestion. Characterisation of the particles (10-100 Bq(239,240)Pu) and investigation of their dissolution kinetics in simulated fluids has been accomplished using a combination of high-resolution alpha-spectrometry, gamma-spectrometry and liquid scintillation counting. The results of these analyses indicate that plutonium transfer across the human gut following the ingestion of 'hot' particles can be up to two orders of magnitude lower than that expected for plutonium in a more soluble form, and show that for areas affected by local fallout, use of published ingestion dose coefficients, together with bulk radionuclide concentrations in soil, may lead to a considerable overestimation of systemic uptake via the ingestion pathway.


Assuntos
Plutônio/farmacocinética , Poluentes Radioativos do Solo/farmacocinética , Partículas alfa , Líquidos Corporais/metabolismo , Mucosa Gástrica/metabolismo , Humanos , Intestino Delgado/metabolismo , Cinética , Contagem de Cintilação , Solubilidade , Espectrometria gama
6.
Environ Pollut ; 142(3): 487-92, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16413954

RESUMO

More than 30 years after the occurrence of an aircraft accident which involved the detonation of two nuclear weapons in the surrounding area of the village of Palomares (Spain), the affected terrestrial area has been investigated for remaining transuranic contamination. Evidence from the presence of this contamination was initially found through the analysis of the 241Am inventories in superficial soil samples collected in the region, and was confirmed through the analysis of the (239+240)Pu inventories and their associated 238Pu/(239+240)Pu activity ratios in the same samples. However, it was also observed that a considerable fraction of the remaining contamination in the area was present in particulate form, i.e. as "hot particles". The work performed in our laboratory for identification, isolation and characterisation of these "hot particles" as well as some conclusions obtained from these analyses are outlined in this paper.


Assuntos
Acidentes Aeronáuticos , Guerra Nuclear , Plutônio/análise , Poluentes Radioativos do Solo/análise , Solo/análise , Monitoramento Ambiental/métodos , Material Particulado , Espanha , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA