Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Front Cardiovasc Med ; 9: 958732, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36324741

RESUMO

Since its conception, transcatheter aortic valve implantation (TAVI) has undergone important improvements both in the implantation technique and in transcatheter devices, allowing an enthusiastic adoption of this therapeutic approach in a wide population of patients previously without a surgical option and managed conservatively. Nowadays, patients with severe symptomatic aortic stenosis are typically managed with TAVI, regardless of their risk to surgery, improving the prognosis of patients and thus achieving an exponential global expansion of its use. However, thromboembolic and hemorrhagic complications remain a latent concern in TAVI recipients. Both complications can appear simultaneously in the periprocedural period or during the follow-up, and when minor, they resolved without apparent sequelae, but in a relevant percentage of cases, they are devastating, overshadowing the benefit achieved with TAVI. Our review outlines the etiology and incidence of thromboembolic complications associated with TAVI, the main current strategies for their prevention, and the implications of its pharmacological management at the follow-up in a TAVI population, mostly frail and predisposed to bleeding complications.

2.
J Cardiovasc Dev Dis ; 9(3)2022 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-35323630

RESUMO

Coronary artery disease (CAD) is a common chronic condition in the elderly. However, the earlier CAD begins, the stronger its impact on lifestyle and costs of health and social care. The present study analyzes clinical and angiographic features and the outcome of very young patients undergoing coronary angiography due to suspected CAD, including a nested case-control study of ≤40-year-old patients referred for coronary angiography. Patients were divided into two groups: cases with significant angiographic stenosis, and controls with non-significant stenosis. Of the 19,321 coronary angiographies performed in our center in a period of 10 years, 504 (2.6%) were in patients ≤40 years. The most common cardiovascular risk factors for significant CAD were smoking (OR 2.96; 95% CI 1.65-5.37), dyslipidemia (OR 2.18; 95% CI 1.27-3.82), and family history of CAD (OR 1.95; 95% CI 1.05-3.75). The incidence of major adverse cardiovascular events (MACE) at follow-up was significantly higher in the cases compared to controls (HR 2.71; 95% CI 1.44-5.11). Three conventional coronary risk factors were directly related to the early signs of CAD. MACE in the long-term follow-up is associated to dyslipidaemia and hypertriglyceridemia. Focusing efforts for the adequate control of CAD in young patients is a priority given the high socio-medical cost that this disease entails to society.

4.
J Am Coll Cardiol ; 77(17): 2187-2199, 2021 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-33926655

RESUMO

BACKGROUND: Among patients with acute coronary syndrome following transcatheter aortic valve replacement (TAVR), those presenting with ST-segment elevation myocardial infarction (STEMI) are at highest risk. OBJECTIVES: The goal of this study was to determine the clinical characteristics, management, and outcomes of STEMI after TAVR. METHODS: This was a multicenter study including 118 patients presenting with STEMI at a median of 255 days (interquartile range: 9 to 680 days) after TAVR. Procedural features of STEMI after TAVR managed with primary percutaneous coronary intervention (PCI) were compared with all-comer STEMI: 439 non-TAVR patients who had primary PCI within the 2 weeks before and after each post-TAVR STEMI case in 5 participating centers from different countries. RESULTS: Median door-to-balloon time was higher in TAVR patients (40 min [interquartile range: 25 to 57 min] vs. 30 min [interquartile range: 25 to 35 min]; p = 0.003). Procedural time, fluoroscopy time, dose-area product, and contrast volume were also higher in TAVR patients (p < 0.01 for all). PCI failure occurred more frequently in patients with previous TAVR (16.5% vs. 3.9%; p < 0.001), including 5 patients in whom the culprit lesion was not revascularized owing to coronary ostia cannulation failure. In-hospital and late (median of 7 months [interquartile range: 1 to 21 months]) mortality rates were 25.4% and 42.4%, respectively (20.6% and 38.2% in primary PCI patients), and estimated glomerular filtration rate <60 ml/min (hazard ratio [HR]: 3.02; 95% confidence interval [CI]: 1.42 to 6.43; p = 0.004), Killip class ≥2 (HR: 2.74; 95% CI: 1.37 to 5.49; p = 0.004), and PCI failure (HR: 3.23; 95% CI: 1.42 to 7.31; p = 0.005) determined an increased risk. CONCLUSIONS: STEMI after TAVR was associated with very high in-hospital and mid-term mortality. Longer door-to-balloon times and a higher PCI failure rate were observed in TAVR patients, partially due to coronary access issues specific to the TAVR population, and this was associated with poorer outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias/etiologia , Medição de Risco/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Angiografia Coronária , Feminino , Seguimentos , Saúde Global , Mortalidade Hospitalar/tendências , Humanos , Incidência , Masculino , Intervenção Coronária Percutânea , Complicações Pós-Operatórias/epidemiologia , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA