1.
Front Neurol ; 12: 632987, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33716934

RESUMO

Objective: Comparing the surgical outcomes of the Minimally Invasive Ponto Surgery (MIPS) technique with the linear incision technique with soft tissue preservation (LITT-P) for bone conduction devices after a follow-up of 22 months. Methods: In this multicenter randomized controlled trial, there was the inclusion of 64 adult patients eligible for unilateral surgery. There was 1:1 randomization to the MIPS (test) or the LITT-P (control) group. The primary outcome was an (adverse) soft tissue reaction. Secondary outcomes were pain, loss of sensibility, soft tissue height/overgrowth, skin sagging, implant loss, Implant Stability Quotient measurements, cosmetic scores, and quality of life questionnaires. Results: Sixty-three subjects were analyzed in the intention-to-treat population. No differences were found in the presence of (adverse) soft tissue reactions during complete follow-up. Also, there were no differences in pain, wound dehiscence, skin level, soft tissue overgrowth, and overall quality of life. Loss of sensibility (until 3-month post-surgery), cosmetic scores, and skin sagging outcomes were better in the MIPS group. The Implant Stability Quotient was higher after the LITT-P for different abutment lengths at various points of follow-up. Implant extrusion was nonsignificantly higher after the MIPS (15.2%) compared with LITT-P (3.3%). Conclusion: The long-term results show favorable outcomes for both techniques. The MIPS is a promising technique with some benefits over the LITT-P. Concerns regarding nonsignificantly higher implant loss may be overcome with future developments and research. Clinical Trial Registration: www.ClinicalTrials.gov, identifier: NCT02438618.

2.
Otol Neurotol ; 39(7): 882-893, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29995008

RESUMO

OBJECTIVE: To compare the surgical outcomes of the Minimally Invasive Ponto Surgery (MIPS) technique with those of the linear incision technique with soft-tissue preservation for bone-anchored hearing systems (BAHS). DESIGN: Sponsor-initiated multicenter, open, randomized, controlled clinical trial. SETTING: Maastricht University Medical Centre, Ziekenhuisgroep Twente and Medisch Centrum Leeuwarden, all situated in The Netherlands. PARTICIPANTS: Sixty-four adult patients eligible for unilateral BAHS surgery.Interventions Single-stage BAHS surgery with 1:1 randomization to the linear incision technique with soft-tissue preservation (control) or the MIPS (test) group. PRIMARY AND SECONDARY OUTCOME MEASUREMENTS: Primary objective: compare the incidence of inflammation (Holgers Index ≥ 2) during 12 weeks' follow-up after surgery. Secondary objectives: skin dehiscence, pain scores, loss of sensibility around the implant, soft-tissue overgrowth, skin sagging, implant extrusion, cosmetic results, surgical time, wound healing and Implant Stability Quotient measurements. RESULTS: Sixty-three subjects were analyzed in the intention-to-treat population. No significant difference was found for the incidence of inflammation between groups. Loss of skin sensibility, cosmetic outcomes, skin sagging, and surgical time were significantly better in the test group. No statistically significant differences were found for dehiscence, pain, and soft-tissue overgrowth. A nonsignificant difference in extrusion was found for the test group. The Implant Stability Quotient was statistically influenced by the surgical technique, abutment length, and time. CONCLUSION: No significant differences between the MIPS and the linear incision techniques were observed regarding skin inflammation. MIPS results in a statistically significant reduction in the loss of skin sensibility, less skin sagging, improved cosmetic results, and reduced surgical time. Although nonsignificant, the implant extrusion rate warrants further research.


Assuntos
Condução Óssea , Implante Coclear/métodos , Implantes Cocleares , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Tratamentos com Preservação do Órgão , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Âncoras de Sutura , Resultado do Tratamento , Adulto Jovem
3.
Eur Arch Otorhinolaryngol ; 275(6): 1395-1408, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29623410

RESUMO

PURPOSE: In this prospective clinical pilot study, abutments with different topologies (machined versus polished) were compared with respect to the clinical outcome and the microbiological profile. Furthermore, three different sampling methods (retrieval of abutment, collection of peri-abutment exudate using paper-points, and a small peri-abutment soft-tissue biopsy) were evaluated for the identification and quantification of colonising bacteria. METHODS: Twelve patients, seven with machined abutment and five with polished abutment, were included in the analysis. Three different sampling procedures were employed for the identification and quantification of colonising bacteria from baseline up to 12 months, using quantitative culturing. Clinical outcome measures (Holgers score, hygiene, pain, numbness and implant stability) were investigated. RESULTS: The clinical parameters, and total viable bacteria per abutment or in tissue biopsies did not differ significantly between the polished and machined abutments. The total CFU/mm2 abutment and CFU/peri-abutment fluid space of anaerobes, aerobes and staphylococci were significantly higher for the polished abutment. Anaerobic bacteria were detected in the tissue biopsies before BAHS implantation. Anaerobes and Staphylococcus spp. were detected in all three compartments after BAHS installation. For most patients (10/12), the same staphylococcal species were found in at least two of the three compartments at the same time-point. The common skin coloniser Staphylococcus epidermidis was identified in all patients but one (11/12), whereas the pathogen Staphylococcus aureus was isolated in five of the patients. Several associations between clinical and microbiological parameters were found. CONCLUSIONS: There was no difference in the clinical outcome with the use of polished versus machined abutment at 3 and 12 months after implantation. The present pilot trial largely confirmed a suitable study design, sampling and analytical methodology to determine the effects of modified BAHS abutment properties. LEVEL OF EVIDENCE: 2. Controlled prospective comparative study.


Assuntos
Auxiliares de Audição/microbiologia , Perda Auditiva/microbiologia , Perda Auditiva/terapia , Âncoras de Sutura/microbiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carga Bacteriana , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos
4.
Trials ; 17(1): 540, 2016 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-27829464

RESUMO

BACKGROUND: Over the last years, less invasive surgical techniques with soft tissue preservation for bone conduction hearing implants (BCHI) have been introduced such as the linear incision technique combined with a punch. Results using this technique seem favorable in terms of rate of peri-abutment dermatitis (PAD), esthetics, and preservation of skin sensibility. Recently, a new standardized surgical technique for BCHI placement, the Minimally Invasive Ponto Surgery (MIPS) technique has been developed by Oticon Medical AB (Askim, Sweden). This technique aims to standardize surgery by using a novel surgical instrumentation kit and minimize soft tissue trauma. METHODS: A multicenter randomized controlled trial is designed to compare the MIPS technique to the linear incision technique with soft tissue preservation. The primary investigation center is Maastricht University Medical Center. Sixty-two participants will be included with a 2-year follow-up period. Parameters are introduced to quantify factors such as loss of skin sensibility, dehiscence of the skin next to the abutment, skin overgrowth, and cosmetic results. A new type of sampling method is incorporated to aid in the estimation of complications. To gain further understanding of PAD, swabs and skin biopsies are collected during follow-up visits for evaluation of the bacterial profile and inflammatory cytokine expression. The primary objective of the study is to compare the incidence of PAD during the first 3 months after BCHI placement. Secondary objectives include the assessment of parameters related to surgery, wound healing, pain, loss of sensibility of the skin around the implant, implant extrusion rate, implant stability measurements, dehiscence of the skin next to the abutment, and esthetic appeal. Tertiary objectives include assessment of other factors related to PAD and a health economic evaluation. DISCUSSION: This is the first trial to compare the recently developed MIPS technique to the linear incision technique with soft tissue preservation for BCHI surgery. Newly introduced parameters and sampling method will aid in the prediction of results and complications after BCHI placement. TRIAL REGISTRATION: Registered at the CCMO register in the Netherlands on 24 November 2014: NL50072.068.14 . Retrospectively registered on 21 April 2015 at ClinicalTrials.gov: NCT02438618 . This trial is sponsored by Oticon Medical AB.


Assuntos
Condução Óssea , Auxiliares de Audição , Perda Auditiva/cirurgia , Pessoas com Deficiência Auditiva/reabilitação , Protocolos Clínicos , Análise Custo-Benefício , Dermatite/etiologia , Desenho de Equipamento , Custos de Cuidados de Saúde , Auxiliares de Audição/economia , Perda Auditiva/diagnóstico , Perda Auditiva/fisiopatologia , Perda Auditiva/psicologia , Humanos , Países Baixos , Procedimentos Cirúrgicos Otológicos/efeitos adversos , Procedimentos Cirúrgicos Otológicos/economia , Procedimentos Cirúrgicos Otológicos/instrumentação , Satisfação do Paciente , Pessoas com Deficiência Auditiva/psicologia , Projetos de Pesquisa , Fatores de Risco , Deiscência da Ferida Operatória , Âncoras de Sutura , Fatores de Tempo , Resultado do Tratamento , Cicatrização