Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 93(15): 6158-6168, 2021 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-33832223

RESUMO

This study presents, for the first time, the successful application of analyzing a whole gas chromatography (GC) chromatogram by nuclear magnetic resonance (NMR) spectroscopy using a continuous repeatable and stable (n = 280) high-resolution (HR) GC fractionation platform with a 96-well plate. Typically with GC- or liquid chromatography-mass spectrometry analysis, (isomer) standards and/or additional NMR analysis are needed to confirm the identification and/or structure of the analyte of interest. In the case of complex substances (e.g., UVCBs), isomer standards are often unavailable and NMR spectra too complex to achieve this. This proof of concept study shows that a HR GC fractionation collection platform was successfully applied to separate, purify, and enrich isomers in complex substances from a whole GC chromatogram, which would facilitate NMR analysis. As a model substance, a chlorinated paraffin (CP) mixture (>8,000 isomers) was chosen. NMR spectra were obtained from all 96 collected fractions, which provides important information for unravelling their full structure. As a proof of concept, a spectral interpretation of a few NMR spectra was made to assign sub-structures. More research is ongoing for the full characterization of CP isomers using multivariate statistical analysis. For the first time, up to only a few CP isomers per fraction were isolated from a highly complex mixture. These may be further purified and certified as standards, which are urgently needed, and can also be used for persistency, bioaccumulation, or toxicity studies.

2.
SLAS Technol ; 24(6): 543-555, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31096846

RESUMO

We describe the development of a high-resolution, noncontact fraction collector for liquid chromatography (LC) separations, allowing high-resolution fractionation in high-density well plates. The device is based on a low-dead-volume solenoid valve operated at 1-30 Hz for accurate collection of fractions of equal volume. The solenoid valve was implemented in a modified autosampler resulting in the so-called FractioMate fractionator. The influence of the solenoid supply voltage on solvent release was determined and the effect of the frequency, flow rate, and mobile phase composition was studied. For this purpose, droplet release was visually assessed for a wide range of frequencies and flow rates, followed by quantitative evaluation of a selection of promising settings for highly accurate, repeatable, and stable fraction collection. The potential of the new fraction collector for LC-based bioactivity screening was demonstrated by fractionating the LC eluent of a mixture of estrogenic and androgenic compounds, and a surface water sample (blank and spiked with bioactives) combining mass spectrometric detection and two reporter gene assays for bioactivity detection of the fractions. Additionally, a mixture of two compounds was repeatedly LC separated and fractionated to assess the feasibility of the system for analyte isolation followed by nuclear magnetic resonance analysis.


Assuntos
Fracionamento Químico/instrumentação , Cromatografia Líquida/instrumentação , Bioensaio , Cromatografia Líquida de Alta Pressão , Genes Reporter , Humanos , Células MCF-7 , Espectroscopia de Ressonância Magnética , Espectrometria de Massas , Solventes
3.
Sci Total Environ ; 601-602: 210-221, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28551540

RESUMO

Thermal paper contains potentially toxic additives, such as bisphenol A (BPA), as a common color developer. Because of its known endocrine disrupting effects, structural analogues to BPA, such as bisphenol S (BPS), D-8 and Pergafast 201, have been used as alternatives, but little is known about the presence and toxicological effects of alternatives other than BPS. In this study, thermal paper is screened by direct probe ambient mass spectrometry (rapid pre-screening method not requiring sample preparation) and by liquid chromatography (LC) with high resolution time-of flight (TOF-MS) mass spectrometry. Cash receipts and other thermal paper products (cinema tickets, boarding passes and luggage tags) were analyzed. Besides BPA and BPS, other developers only recently reported (Pergafast 201, D-8) or to the best of our knowledge not reported before (D-90, TGSA, BPS-MAE) were frequently found as well as some related unreported impurities (2,4-BPS that is a BPS related impurity and a TGSA related impurity). To gain some insight into the potential estrogenicity of the detected developers, a selection of extracts was further analyzed using a LC-nanofractionation platform in combination with cell-based bioassay testing. These preliminary results seems to indicate very low or absence of estrogenic activity for Pergafast 201, D-8, D-90, TGSA and BPS-MAE in comparison to BPA and BPS, although further dose-response tests with authentic standards are required to confirm these results. Compounds for which standards were available were also tested for developmental toxicity and neurotoxicity using zebrafish (Danio rerio) embryos. TGSA and D-8 induced similar teratogenic effects as BPA in zebrafish embryos. BPS and 2,4-BPS did not induce any developmental effects but 2,4-BPS did alter the locomotor activity at the tested concentration. Our findings suggest that the alternatives used as alternatives to BPA (except BPS) might not be estrogenic. However, TGSA and D-8 showed abnormal developmental effects similar to BPA.


Assuntos
Compostos Benzidrílicos/análise , Papel , Fenóis/análise , Testes de Toxicidade , Animais , Linhagem Celular Tumoral , Humanos , Países Baixos , Noruega , Espanha , Suécia , Peixe-Zebra
4.
Talanta ; 168: 162-167, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28391837

RESUMO

We describe the development and evaluation of a GC-MS fractionation platform that combines high-resolution fraction collection of full chromatograms with parallel MS detection. A y-split at the column divides the effluent towards the MS detector and towards an inverted y-piece where vaporized trap solvent is infused. The latter flow is directed outside the GC oven allowing subsequent condensation and stepwise collection of liquid fractions with trapped analytes on a 384-well plate. For study and optimization of the effluent split ratio, restriction capillaries of different lengths and diameters were evaluated. For a wide range of settings, local pressures were monitored during fractionation to assess the influence of MS vacuum and trap solvent infusion on the GC system stability. The platform performance was evaluated by GC-MS analysis and continuous fractionation of an n-alkane mixture followed by GC analysis of each fraction. Comparison of the on-line recorded and fraction-reconstructed chromatogram showed the GC separation is maintained during fractionation. Multiple fractionation cycles of the n-alkane sample on the same 384-well plate yielded a reconstructed chromatogram which was highly similar to that of a single analysis, demonstrating the high repeatability. The applicability of the GC-MS-fractionation platform for bioactivity screening was investigated by applying the AR-Ecoscreen reporter gene bioassay on fractions obtained after analysis of standard solutions and dust samples containing the anti-androgenic compounds vinclozolin and p,p'-DDE.


Assuntos
Antagonistas de Receptores de Andrógenos/análise , Fracionamento Químico/métodos , Poeira/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Genes Reporter/efeitos dos fármacos , Receptores Androgênicos/química , Antagonistas de Receptores de Andrógenos/farmacologia , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Humanos
5.
Environ Sci Technol ; 50(22): 12385-12393, 2016 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-27934237

RESUMO

The chemical safety of consumer products is an issue of emerging concern. Plastics are widely used, e.g. as casings of consumer electronics (TVs, computers, routers, etc.), which are present in houses and offices in continuously increasing numbers. In this study, we investigate the estrogenic activity of components of plastics coming from electronics' casings. A recently developed fractionation platform for effect-directed analysis (EDA) was used. This platform combines reversed-phase liquid chromatography in parallel with bioassay detection via nanofractionation and with online high-resolution time-of-flight mass spectrometry (TOFMS) for the identification of bioactives. Four out of eight of the analyzed plastics samples showed the presence of estrogenic compounds. Based on the MS results these were assigned to bisphenol A (BPA), 2,4-di-tert-butylphenol, and a possible bisphenol A analog. All samples contained flame retardants, but these did not show any estrogenicity. The observed BPA, however, could be an impurity of tetrabromo-BPA (TBBPA) or TBBPA-based flame retardants. Due to the plausible migration of additives from plastics into the environment, plastics from consumer electronics likely constitute a source of estrogenic compound contamination in the indoor environment.


Assuntos
Plásticos/química , Cromatografia Líquida , Estrogênios , Retardadores de Chama , Espectrometria de Massas
6.
J Chromatogr A ; 1462: 100-6, 2016 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-27485151

RESUMO

Gas chromatography (GC) is a superior separation technique for many compounds. However, fractionation of a GC eluate for analyte isolation and/or post-column off-line analysis is not straightforward, and existing platforms are limited in the number of fractions that can be collected. Moreover, aerosol formation may cause serious analyte losses. Previously, our group has developed a platform that resolved these limitations of GC fractionation by post-column infusion of a trap solvent prior to continuous small-volume fraction collection in a 96-wells plate (Pieke et al., 2013 [17]). Still, this GC fractionation set-up lacked a chemical detector for the on-line recording of chromatograms, and the introduction of trap solvent resulted in extensive peak broadening for late-eluting compounds. This paper reports advancements to the fractionation platform allowing flame ionization detection (FID) parallel to high-resolution collection of a full GC chromatograms in up to 384 nanofractions of 7s each. To this end, a post-column split was incorporated which directs part of the eluate towards FID. Furthermore, a solvent heating device was developed for stable delivery of preheated/vaporized trap solvent, which significantly reduced band broadening by post-column infusion. In order to achieve optimal analyte trapping, several solvents were tested at different flow rates. The repeatability of the optimized GC fraction collection process was assessed demonstrating the possibility of up-concentration of isolated analytes by repetitive analyses of the same sample. The feasibility of the improved GC fractionation platform for bioactivity screening of toxic compounds was studied by the analysis of a mixture of test pesticides, which after fractionation were subjected to a post-column acetylcholinesterase (AChE) assay. Fractions showing AChE inhibition could be unambiguously correlated with peaks from the parallel-recorded FID chromatogram.


Assuntos
Ionização de Chama/instrumentação , Ionização de Chama/métodos , Praguicidas/análise , Acetilcolinesterase/metabolismo , Inibidores da Colinesterase/análise , Solventes
7.
J Chromatogr A ; 1406: 165-74, 2015 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-26116188

RESUMO

In this study we developed a new LC nanofractionation platform that combines a human cell (BG1.Luc) gene reporter assay with a high resolution mass spectrometer for the detection and identification of estrogenic and anti-estrogenic compounds in environmental waters. The selection of this assay was based on its high sensitivity and selectivity, which is required for environmental trace level detection. We modified an autosampler and controlled it with in-house developed software to collect fractions in the low second range in microtiter plates. This ensured that chromatographic separation was maintained and allowed straightforward hyphenation with the bioassay. After bioassay testing, bioassay chromatograms were reconstructed and directly correlated with MS chromatograms that were obtained in parallel. This enabled to pinpoint bioactives in the MS chromatogram within a single fractionation cycle and results in a significant increase in throughput compared to traditional EDA studies. The sensitivity of the platform was low enough for environmental waters (80nM for bisphenol A and 320pM and 3.2nM for estradiol and estriol, respectively). In addition, the ability of the platform to detect anti-estrogens was successfully demonstrated as well. Finally, real samples were analysed.


Assuntos
Técnicas de Química Analítica/instrumentação , Técnicas de Química Analítica/métodos , Cromatografia Líquida , Monitoramento Ambiental/métodos , Estrogênios/análise , Espectrometria de Massas , Água/química , Bioensaio , Estradiol/análise , Poluentes Químicos da Água/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA