Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 130
Filtrar
1.
Bone Joint J ; 106-B(5): 435-441, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38688480

RESUMO

Aims: Refobacin Bone Cement R and Palacos R + G bone cement were introduced to replace the original cement Refobacin Palacos R in 2005. Both cements were assumed to behave in a biomechanically similar fashion to the original cement. The primary aim of this study was to compare the migration of a polished triple-tapered femoral stem fixed with either Refobacin Bone Cement R or Palacos R + G bone cement. Repeated radiostereometric analysis was used to measure migration of the femoral head centre. The secondary aims were evaluation of cement mantle, stem positioning, and patient-reported outcome measures. Methods: Overall, 75 patients were included in the study and 71 were available at two years postoperatively. Prior to surgery, they were randomized to one of the three combinations studied: Palacos cement with use of the Optivac mixing system, Refobacin with use of the Optivac system, and Refobacin with use of the Optipac system. Cemented MS30 stems and cemented Exceed acetabular components were used in all hips. Postoperative radiographs were used to assess the quality of the cement mantle according to Barrack et al, and the position and migration of the femoral stem. Harris Hip Score, Oxford Hip Score, Forgotten Joint Score, and University of California, Los Angeles Activity Scale were collected. Results: Median distal migration (y-axis) at two years for the Refobacin-Optivac system was -0.79 mm (-2.01 to -0.09), for the Refobacin-Optipac system was -0.75 mm (-2.16 to 0.20), and for the Palacos-Optivac system was -1.01 mm (-4.31 to -0.29). No statistically significant differences were found between the groups. Secondary outcomes did not differ statistically between the groups at the two-year follow-up. Conclusion: At two years, we found no significant differences in distal migration or clinical outcomes between the three groups. Our data indicate that Refobacin Bone Cement R and Palacos R + G are comparable in terms of stable fixation and early clinical outcomes.


Assuntos
Artroplastia de Quadril , Cimentos Ósseos , Prótese de Quadril , Humanos , Masculino , Feminino , Estudos Prospectivos , Artroplastia de Quadril/métodos , Artroplastia de Quadril/instrumentação , Idoso , Pessoa de Meia-Idade , Análise Radioestereométrica , Falha de Prótese , Desenho de Prótese , Medidas de Resultados Relatados pelo Paciente , Idoso de 80 Anos ou mais , Polimetil Metacrilato
2.
Bone Rep ; 19: 101723, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38047271

RESUMO

Introduction: Osseointegration of hip implants, although a decade-long process, shows striking similarities with the four major phases of endochondral bone repair. In the current study we investigated the spatiotemporal involvement of bone morphogenic proteins (BMPs) and transforming growth factor betas (TGF-ßs) throughout the process of bone repair leading to successfully osseointegrated hip implants. Materials and methods: Twenty-four patients that had undergone primary total hip arthroplasty (THA) due to one-sided osteoarthritis (OA) were investigated during a period of 18 years (Y) with repeated measurements of plasma biomarkers as well as clinical and radiological variables. All implants were clinically and radiographically well anchored throughout the follow-up. Eighty-one healthy donors divided in three gender- and age-matched groups and twenty OA patients awaiting THA, served as controls. Plasma was analyzed for BMP-1, -2, -3, -4, -6, -7 -9 and TGF-ß1, -ß2, -ß3 by use of a high-sensitivity and wide dynamic range electrochemiluminescence technique allowing for detection of minor changes. Results: Spatiotemporal changes during the follow-up are presented in the context of the four phases of endochondral bone repair shown in earlier studies and transposed to the current study based on similarities in biomarker responses. Phase 1: Primary proinflammatory phase lasting from surgery until day 7, Phase 2: Chondrogenic phase from day 7 until 18 months postsurgery, Phase 3: Secondary proinflammatory and cartilage remodeling phase lasting from 18 months until 7Y, Phase 4: coupled bone remodeling from 7Y until 18Y postsurgery. BMP-1 increased sharply shortly after surgery and remained significantly above healthy during the chondrocyte recruitment, proliferation, and hypertrophy phases with a subsequent return to control level at 5Y postsurgery. BMP-2 was above healthy controls before surgery and 1 day after surgery before decreasing to control level and remaining there throughout the follow-up. BMP-3 was at control level from presurgery until 6M after surgery when it increased to a peak at 2Y during the cartilage hypertrophy phase followed by a gradual decrease to control level at 10Y during the phase of bone formation. In the following, BMP-3 decreased below controls to a nadir 15Y postsurgery during coupled bone remodeling. BMP-4 was at control level from presurgery until 10Y postsurgery when it increased to a sharp peak at 15Y after surgery followed by a return to the level of healthy at 18Y. BMP-6 did not differ from healthy during the follow-up. BMP-7 was at control level from presurgery until 1Y postsurgery before gradually increasing to a peak at 10Y during the early phase of osteogenesis with a gradual return to control level at 18Y during the phase of coupled bone remodeling. BMP-9 was above OA before surgery followed by a decrease to basal level on day 1 after surgery and a renewed increase to a plateau above controls lasting from 6 W until returning to the level of healthy at 18Y postsurgery, i.e., throughout the phases of cartilage formation, cartilage hypertrophy and remodeling, bone formation and coupled bone remodeling. TGF-ß1 was above controls presurgery before decreasing to baseline shortly after surgery followed by a renewed increase at 6 M to a peak at 2Y during cartilage hypertrophy/remodeling followed by a gradual return to baseline at 10Y during early osteoblastogenesis. TGF-ß2 was at control level from presurgery until the phase of cartilage remodeling at 5Y when it increased sharply to a peak at 7Y with a gradual return to baseline at 18Y postsurgery. TGF-ß3 remained at control level throughout the study. Conclusion: This study shows that the involvement of BMPs and TGF-ßs in endochondral bone repair is a process of stepwise recruitment of individual biomarkers characterized by distinct, yet overlaping, spatiotemporal patterns that extend from the early phase of pre-chondrocyte recruitment until the late phase of coupled bone remodeling.

3.
Acta Orthop ; 94: 607-608, 2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-38093708

RESUMO

When we checked our data in our article "Similar outcome with a new anteverted or a straight standard stem: a randomized study of 72 total hip arthroplasties evaluated with clinical variables, radiostereometry, and DXA up to 2 years" by Karin Rilby, Maziar Mohaddes, Emma Nauclér, and Johan Kärrholm, Acta Orthop 2021; 92, Published online October 21, 2021 we noticed that the numbers in Table 7 (Supplementary data) were incorrect. We have not been able to fully reconstruct the reason for this error. We are sorry for this mistake. Even if the corrected numbers are different the overall conclusions will be same and also the statistical significances.

4.
Hip Int ; : 11207000231208099, 2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38087800

RESUMO

BACKGROUND: The choice between cemented or uncemented stem fixation in the treatment of a femoral neck fracture may influence patient rehabilitation and the resulting gait pattern, due to potential differences in implant positioning and fixation. We used gait analysis to study temporal gait parameters, hip kinematics and kinetics in patients who, 2 years previously, had been randomised to treatment with a cemented or uncemented stem and due to an acute femoral neck fracture. METHODS: 45 Patients implanted with a cemented Lubinus SP II (n = 29) and an uncemented (n = 16) Corail stem were studied. Gait analysis was performed using a 16-camera motion capture system and force plates. 28 subjects served as controls. Temporal gait parameters, hip kinematics and kinetics were analysed. The patients had no or minimum pain (median Harris pain score 44, range 40-44) and the majority had no limp (median Harris limp score 11, range 5-11). RESULTS: Temporospatial gait parameters and abduction-adduction motions and moments did not differ between patients with cemented or uncemented stems (p > 0.05). Patients with cemented stems did, however, show more hip flexion and less extension during walking than those with an uncemented stem (p < 0.05). Moreover, the flexion-extension range was less in the cemented group (p < 0.04). Compared with controls, the hip fracture patients walked more slowly, with a shorter stride length and a longer stance phase. CONCLUSIONS: Increased hip flexion and reduced extension in patients using the Lubinus SP II cemented stem could be an effect of its anteverted neck, but this question requires further study. Despite acute treatment with THA, hip fracture patients demonstrated a change in gait pattern compared with controls 2 years after the operation. This suggests that these changes are caused by the presence of an implant, or the soft-tissue trauma partly caused by the surgery than by any degenerative disease present in patients undergoing elective surgery.ClinicalTrials.gov Identifier: NCT04791605.

5.
Acta Orthop ; 94: 477-483, 2023 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-37746752

RESUMO

BACKGROUND AND PURPOSE: Few studies have focused on nonagenarians treated with total hip arthroplasty (THA). We investigated 30- and 90-day postoperative mortality, patient-reported outcome measures (PROMs), reoperation rate, risk factors for reoperation, and relative patient survival in nonagenarians or older. PATIENTS AND METHODS: 167,091 patients with primary cemented THA performed for osteoarthritis between 1992 and 2019 were identified in the Swedish Arthroplasty Register. Patients were divided into age groups based on age at time of surgery: 60-74 (n = 90,285), 75-89 (n = 75,421), and > 90 years (n = 1,385). Mortality rate, PROMs (pain-Likert scale, satisfaction-Likert scale, EQ-VAS, n = 67,553), reoperation rate, risk factors for reoperation, and relative patient survival were studied. RESULTS: The nonagenarians had the highest postoperative mortality rate, 1.7% and 2.6% at 30 and 90 days, respectively. Nonagenarian females reported significantly lower pre- and postoperative EQ-VAS compared with patients aged 60-89 years but reported least pain and highest patient satisfaction 1 year after surgery. At 2 years the nonagenarians had highest reoperation frequency-2.7%-due to infection (1.5%), dislocation (0.8%), and periprosthetic fracture (0.4%). Increasing age, male sex, and polished stem were associated with higher risk of reoperation within 2 years. 8-year age- and sex-matched relative survival was highest among nonagenarians (study group/matched population: ≥ 90 years 3.4, 95% confidence interval [CI] 3.0-3.8; 75-89 years: 1.4, CI 1.4-1.4, and 60-74 years: 1.1, CI 1.1-1.1). CONCLUSION: 30- and 90-day postoperative mortality and reoperation rates were higher in nonagenarians but PROM data showed least pain and highest patient satisfaction 1 year after surgery with THA among female nonagenarians with primary osteoarthritis.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteoartrite do Quadril , Osteoartrite , Idoso de 80 Anos ou mais , Humanos , Masculino , Feminino , Pré-Escolar , Artroplastia de Quadril/efeitos adversos , Suécia/epidemiologia , Osteoartrite/cirurgia , Satisfação do Paciente , Dor/etiologia , Reoperação , Sistema de Registros , Resultado do Tratamento , Osteoartrite do Quadril/cirurgia , Osteoartrite do Quadril/etiologia
6.
Acta Orthop ; 94: 438-446, 2023 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-37593786

RESUMO

BACKGROUND AND PURPOSE: The Lubinus SP2 stem has been associated with a very low risk of periprosthetic femoral fractures (PPFFs). We aimed, primarily, to study the radiographic morphology of PPFFs close to a Lubinus SP2 stem. Secondarily, we analyzed whether higher reoperation rate was correlated to the revision method chosen or to the characteristics of the fracture and of the bone. PATIENTS AND METHODS: The study included 156 femoral fractures close to a Lubinus cemented stem. These fractures were treated in 40 hospitals in Sweden between 2006 and 2011 and were followed up until 2019. Data from the Swedish Arthroplasty Register was used. Medical records and radiographs were studied. The fractures were classified according to the Vancouver classification. The fracture location and anatomy were delineated. We also measured the remaining attachment index (RAI) and the canal thickness ratio. RESULTS: Vancouver type C (n = 101) and spiral fractures (n = 67, 41 in Vancouver C and 26 in Vancouver B) were the most common fracture types. 4 fractures were avulsion of the greater trochanter. The remaining 51 fractures occurred around the stem (B1: 25, B2: 16, and B3: 10). B fractures were more commonly reoperated on (18 of 51, 35%) than type C fractures (11 of 101, 11%, P = 0.001). In most femurs with type B3 fracture, the fracture line covered an area only around the stem, but in all B1 and in 11 of 16 B2 fractures, it was extended even distal to the stem. ORIF instead of stem revision in B2 fractures, use of short stems or plates, and inadequate reduction of the fractures were risk factors for subsequent reoperations. CONCLUSION: The higher reoperation rate in type B fractures, compared with fractures distal to the stem, could be caused by their higher degree of complexity and reduced capacity for healing in the region around the stem.


Assuntos
Fraturas do Fêmur , Fraturas Periprotéticas , Humanos , Fraturas Periprotéticas/epidemiologia , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Reoperação , Cirurgia de Second-Look , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/cirurgia , Fatores de Risco
7.
Acta Orthop ; 94: 307-315, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-37378447

RESUMO

BACKGROUND AND PURPOSE: The incidence of periprosthetic joint infection after total hip arthroplasty (THA) may be increasing. We performed time-trend analyses of risk, rates, and timing of revision due to infection after primary THAs in the Nordic countries from the period 2004-2018. PATIENTS AND METHODS: 569,463 primary THAs reported to the Nordic Arthroplasty Register Association from 2004 to 2018 were studied. Absolute risk estimates were calculated by Kaplan-Meier and cumulative incidence function methods, whereas adjusted hazard ratios (aHR) were assessed by Cox regression with the first revision due to infection after primary THA as primary endpoint. In addition, we explored changes in the time span from primary THA to revision due to infection. RESULTS: 5,653 (1.0%) primary THAs were revised due to infection during a median follow-up time of 5.4 (IQR 2.5-8.9) years after surgery. Compared with the period 2004-2008, the aHRs for revision were 1.4 (95% confidence interval [CI] 1.3-1.5) for 2009-2013, and 1.9 (CI 1.7-2.0) for 2014-2018. The absolute 5-year rates of revision due to infection were 0.7% (CI 0.7-0.7), 1.0% (CI 0.9-1.0), and 1.2% (CI 1.2-1.3) for the 3 time periods respectively. We found changes in the time span from primary THA to revision due to infection. Compared with 2004-2008, the aHR for revision within 30 days after THA was 2.5 (CI 2.1-2.9) for 2009-2013, and 3.4 (CI 3.0-3.9) for 2013-2018. The aHR for revision within 31-90 days after THA was 1.5 (CI 1.3-1.9) for 2009-2013, and 2.5 (CI 2.1-3.0) for 2013-2018, compared with 2004-2008. CONCLUSION: The risk of revision due to infection after primary THA almost doubled, both in absolute cumulative incidence and in relative risk, throughout the period 2004-2018. This increase was mainly due to an increased risk of revision within 90 days of THA. This may reflect a "true" increase (i.e., frailer patients or more use of uncemented implants) and/or an "apparent" increase (i.e., improved diagnostics, changed revision strategy, or completeness of reporting) in incidence of periprosthetic joint infection. It is not possible to disclose such changes in the present study, and this warrants further research.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Infecções Relacionadas à Prótese , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Falha de Prótese , Sistema de Registros , Fatores de Risco , Reoperação/efeitos adversos
8.
Acta Orthop ; 94: 266-273, 2023 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-37291896

RESUMO

BACKGROUND AND PURPOSE: The bearings with the best survivorship for young patients with total hip arthroplasty (THA) should be identified. We compared hazard ratios (HR) of revision of primary stemmed cementless THAs with metal-on-metal (MoM), ceramic-on-ceramic (CoC), and ceramic-on-highly-crosslinked-polyethylene (CoXLP) with that of metal-on-highly-crosslinked-polyethylene (MoXLP) bearings in patients aged 20-55 years with primary osteoarthritis or childhood hip disorders. PATIENTS AND METHODS: From the Nordic Arthroplasty Register Association dataset we included 1,813 MoM, 3,615 CoC, 5,947 CoXLP, and 10,219 MoXLP THA in patients operated on between 2005 and 2017 in a prospective cohort study. We used the Kaplan-Meier estimator for THA survivorship and Cox regression to estimate HR of revision adjusted for confounders (including 95% confidence intervals [CI]). MoXLP was used as reference. HRs were calculated during 3 intervals (0-2, 2-7, and 7-13 years) to meet the assumption of proportional hazards. RESULTS: Median follow-up was 5 years for MoXLP, 10 years for MoM, 6 years for CoC, and 4 years for CoXLP. 13-year Kaplan-Meier survival estimates were 95% (CI 94-95) for MoXLP, 82% (CI 80-84) for MoM, 93% (CI 92-95) for CoC, and 93% (CI 92-94) for CoXLP bearings. MoM had higher 2-7 and 7-13 years' adjusted HRs of revision (3.6, CI 2.3-5.7 and 4.1, CI 1.7-10). MoXLP, CoC, and CoXLP had similar HRs in all 3 periods. The 7-13-year adjusted HRs of revision of CoC and CoXLP were statistically non-significantly higher. CONCLUSION: In young patients, MoXLP for primary cementless THA had higher revision-free survival and lower HR for revision than MoM bearings. Longer follow-up is needed to compare MoXLP, CoC, and CoXLP.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Criança , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Estudos Prospectivos , Fatores de Risco , Polietileno , Metais , Cerâmica , Reoperação , Desenho de Prótese , Falha de Prótese
9.
Clin Orthop Relat Res ; 481(9): 1689-1699, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37104550

RESUMO

BACKGROUND: The Exeter® stem is used worldwide, often in older patients, and it is the second most commonly used cemented stem design in Sweden. Previous studies have shown that for cemented stems with a composite beam, the smallest sizes result in an increased risk of revision for mechanical failure. However, little is known about whether the survivorship of the polished Exeter stem, which generally has been shown to be good, might be associated with design parameters such as stem dimensions or offset at extreme implant sizes. QUESTION/PURPOSE: Are differences in (1) stem size or (2) offset of the standard Exeter V40 150-mm stem associated with differences in the risk of stem revision for aseptic loosening? METHODS: Between 2001 and 2020, 47,161 Exeter stems were reported to the Swedish Arthroplasty Register, with very high coverage and completeness documented during the period studied. In this cohort, we included patients with primary osteoarthritis who underwent surgery with a standard Exeter stem length of 150 mm and V40 cone with any type of cemented cups that had had at least 1000 reported insertions. This selection resulted in a study cohort representing 79% (37,619 of 47,161) of the total number of Exeter stems in the registry during that time. The primary study outcome was stem revision for aseptic indications such as loosening, periprosthetic fracture, dislocation, and implant fracture. A Cox regression was performed, with adjustment for age, gender, surgical approach, year of surgery, use of highly crosslinked polyethylene cups, and femoral head size and length dictated by the shape of the head trunnion. Adjusted hazard ratios are presented with 95% confidence intervals. Two separate analyses were performed. The first analysis excluded stems with the highest offsets (50 mm and 56 mm, which were not available for stem size 0). The second analysis excluded stem size 0 to include all offsets. Because stem survival was not proportional over time, we divided the analyses into two insertion periods, 0 to 8 years and beyond 8 years. RESULTS: Stem size 0 (compared to size 1) was associated with an increased risk of revision up to 8 years when all stem sizes were included (first analysis 0 to 8 years, HR 1.7 [95% CI 1.2 to 2.3]; p = 0.002). Forty-four percent (63 of 144) of revisions of size 0 stems were for periprosthetic fracture. There was no consistent association between stem size and risk of aseptic stem revision when size 0 was excluded in the second analysis beyond 8 years. The most common offset (44 mm) was associated with an increased risk of revision (compared with 37.5 mm) up to 8 years when all sizes were included (first analysis, HR 1.6 [95% CI 1.1 to 2.1]; p = 0.01). In the second analysis (beyond 8 years, all offsets included), offset of 44 mm was compared with offset of 37.5 mm; compared with the first period, this offset was associated with a reduced risk (HR 0.6 [95% CI 0.4 to 0.9]; p = 0.005). CONCLUSION: We found overall high survival of the Exeter stem, with generally little or no influence of stem variations on the risk of aseptic revision. However, stem size 0 was associated with an increased risk of revision mainly for periprosthetic fractures. If the femoral anatomy offers a choice between sizes 0 and 1 in patients with poor bone quality who are at risk of periprosthetic fracture, our data speak in favor of choosing the larger stem if the surgeon believes it is safe to insert the larger size, or, if available, another stem design that has a documented lower risk of this complication. For patients with good cortical bone quality but very narrow canals, a cementless stem may also be a good alternative. LEVEL OF EVIDENCE: Level III, therapeutic study.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Idoso , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Suécia , Fraturas Periprotéticas/cirurgia , Falha de Prótese , Reoperação/efeitos adversos , Desenho de Prótese , Sistema de Registros , Fatores de Risco
10.
Acta Orthop ; 93: 317-326, 2022 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-35138409

RESUMO

BACKGROUND AND PURPOSE: Concerns related to a potentially increased risk of cancer after total hip arthroplasty (THA) have frequently surfaced, especially since the novel EU medical device regulation classified cobalt as carcinogenic. We assessed the risk of cancer after THA in a nationwide cohort of patients younger than 55 years at surgery. PATIENTS AND METHODS: In this population-based longitudinal cohort study, 18,771 individuals exposed to THA were identified in the Swedish Hip Arthroplasty Registry (SHAR) and compared with 87,683 unexposed individuals who were matched by age, sex, and residence. Diagnoses, socioeconomic background, and dates of death were obtained from the Swedish Cancer Register, the National Patient Register, and Statistics Sweden. Primary outcome was the adjusted risk of any cancer after the first THA; secondary outcomes were specific cancer forms. RESULTS: We found no enhanced adjusted risk of developing any cancer, either in exposed females compared with unexposed females (hazard ratio [HR] 1.1, 95% confidence interval [CI] 0.95-1.2), or in exposed males (HR 1.1, CI 0.99-1.2). When analysing specific cancers, increased adjusted risks were found for thyroid and pancreas cancer in exposed females, and for cancer of the stomach, skin melanoma, and prostate cancer in exposed males. INTERPRETATION: This study indicates that there is no statistically significant increased overall risk of cancer in young THA-exposed patients. The potentially slightly enhanced risk for specific cancers may be due to residual confounding resulting from risk factors not accounted for and merits further investigation.


Assuntos
Artroplastia de Quadril , Neoplasias , Artroplastia de Quadril/métodos , Estudos de Coortes , Feminino , Humanos , Estudos Longitudinais , Masculino , Neoplasias/epidemiologia , Neoplasias/etiologia , Sistema de Registros , Fatores de Risco
11.
Acta Orthop ; 93: 37-42, 2022 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-34633905

RESUMO

Background and purpose - Almost all prosthetic implant brands include several variations. Most studies on implant performance investigate an implant system without sub-analysis of implant attributes. We studied the influence of design variations during the last 2 decades on implant survival of the most frequently used cemented femoral stem, the Lubinus SPII, reported to the Swedish Arthroplasty Register (SHAR). Patients and methods - Between 2000 and 2018, 100,032 cemented Lubinus SP II stems had been reported to SHAR. Patients with primary osteoarthritis operated on with stem length 150 mm together with a cemented cup from the same manufacturer (n = 76,530) were included in this analysis. Primary study outcome was non-infectious stem revision. Cox regression with adjustment for age, sex, surgical approach, and year of surgery was used. Hazard rates (HR) are presented with 95% confidence intervals (CI). Results - Average follow-up was 7.6 years (SD 4.2). At 18 years the overall stem survival was 99.1 (CI 98.9-99.3). Increased revision rate was observed for stems with extra offset, when a long or an extra-long head length had been used. Smaller stem sizes, in particular the smallest stem size (01), substantially increased the rate of mechanical failure as reflected by an almost 10 times increased rate of revision compared with the standard size (2). Interpretation - In this study with larger sample size and longer follow-up than previously presented from the same register, we observed more pronounced effects of previously documented design variations. Based on our results, surgeons using the Lubinus SPII stems are advised to consider an alternative solution if a Lubinus stem size 01, Lubinus extra offset, or an extra-long head seems to be the most suitable choice at the preoperative planning.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Idoso , Cimentos Ósseos , Feminino , Humanos , Masculino , Sistema de Registros , Suécia
12.
PLoS One ; 16(11): e0257310, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34735461

RESUMO

Inflammatory bowel disease (IBD) is characterized by chronic inflammation of the intestinal tract and is associated with decreased bone mineral density. IBD patients are at higher risk of osteopenia, osteoporosis and fracture compared to non-IBD patients. The impact of IBD on the performance of orthopedic implants has not been well studied. We hypothesized that a history of IBD at the time of primary total hip arthroplasty (THA) would increase the risk of subsequent failure as assessed by revision surgery. A retrospective implant survival analysis was completed using the Swedish Hip Arthroplasty Registry and the Sweden National Patient Register. A total of 150,073 patients undergoing THA for osteoarthritis within an 18-year period were included in the study. THA patients with (n = 2,604) and without (n = 147,469) a history of IBD at the time of THA were compared with primary revision as the main endpoint and adjusted using sex, age category and comorbidity (Elixhauser scores) as covariates. We found that patients with a history of IBD had a relatively higher risk of revision surgery for septic causes while the non-IBD patients had a relatively higher risk of revision for aseptic causes (p = 0.004). Our findings suggest there may be an association between gut health and THA performance.


Assuntos
Densidade Óssea , Doenças Inflamatórias Intestinais/cirurgia , Osteoartrite/cirurgia , Reoperação , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Doenças Ósseas Metabólicas/etiologia , Doenças Ósseas Metabólicas/fisiopatologia , Doenças Ósseas Metabólicas/cirurgia , Feminino , Prótese de Quadril/efeitos adversos , Humanos , Doenças Inflamatórias Intestinais/complicações , Doenças Inflamatórias Intestinais/fisiopatologia , Masculino , Pessoa de Meia-Idade , Osteoartrite/etiologia , Osteoartrite/fisiopatologia , Osteoporose/etiologia , Osteoporose/fisiopatologia , Osteoporose/cirurgia , Falha de Prótese/efeitos adversos , Sistema de Registros , Fatores de Risco , Suécia
13.
Acta Orthop ; 92(4): 413-418, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33821752

RESUMO

Background and purpose - Reported revision rates due to dislocation after hemiarthroplasty span a wide range. Dislocations treated with closed reduction are rarely reported despite the fact that they can be expected to constitute most of the dislocations that occur. We aimed to describe the total dislocation rate on the national level, and to identify risk factors for dislocation.Patients and methods - We co-processed a national cohort of 25,678 patients in the Swedish Hip Arthroplasty Register, with the National Patient Register (NPR) and Statistics Sweden. Dislocation was defined as the occurrence of any ICD-10 or procedural code related to hip dislocation recorded in the NPR, with a minimum of 1-year-follow-up. In theory, all early dislocations should thereby be traced, including those treated with closed reduction only.Results - 366/13,769 (2.7%) patients operated on with direct lateral approach dislocated, compared with 850/11,834 (7.2%) of those with posterior approach. Posterior approach was the strongest risk factor for dislocation (OR = 2.7; 95% CI 2.3-3.1), followed by dementia (OR = 1.3; CI 1.1-1.5). The older the patients, the lower the risk of dislocation (OR = 0.98 per year of age; CI 0.98-1.0). Neither bipolar design nor cementless stems influenced the risk.Interpretation - The choice of posterior approach and dementia was associated with an increased dislocation risk. When hips treated with closed reduction were identified, the frequency of dislocation with use of direct lateral and posterior approach more than doubled and tripled, respectively, compared with when only revisions due to dislocation are measured.


Assuntos
Fraturas do Colo Femoral/cirurgia , Hemiartroplastia/métodos , Luxação do Quadril/etiologia , Complicações Pós-Operatórias/etiologia , Falha de Prótese/etiologia , Reoperação/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Luxação do Quadril/cirurgia , Humanos , Masculino , Complicações Pós-Operatórias/cirurgia , Fatores de Risco , Suécia
14.
Acta Orthop ; 92(1): 15-22, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33167753

RESUMO

Background and purpose - Collaborations between arthroplasty registries are important in order to create the possibility of detecting inferior implants early and improve our understanding of differences between nations in terms of indications and outcomes. In this registry study we compared patient and procedure characteristics, and revision rates in the Nordic Arthroplasty Register Association (NARA) database and the Dutch Arthroplasty Register (LROI).Patients and methods - All total hip arthroplasties (THAs) performed in 2010-2016 were included from the LROI (n = 184,862) and the NARA database (n = 290,823), which contains data from Denmark, Norway, Sweden, and Finland. Descriptive statistics and Kaplan-Meier survival analyses based on all reasons for revision and stratified by fixation were performed and compared between countries.Results - In the Netherlands, the proportion of patients aged < 55 years (9%) and male patients (34%) was lower than in Nordic countries (< 55 years 11-13%; males 35-43%); the proportion of osteoarthritis (OA) (87%) was higher compared with Sweden (81%), Norway (77%), and Denmark (81%) but comparable to Finland (86%). Uncemented fixation was used in 62% of patients in the Netherlands, in 70% of patients in Denmark and Finland, and in 28% and 19% in Norway and Sweden, respectively. The 5-year revision rate for THAs for OA was lower in Sweden (2.3%, 95% CI 2.1-2.5) than in the Netherlands (3.0%, CI 2.9-3.1), Norway (3.8%, CI 3.6-4.0), Denmark (4.6%, CI 4.4-4.8), and Finland (4.4%, CI 4.3-4.5). Revision rates in Denmark, Norway, and Finland were higher for all fixation groups.Interpretation - Patient and THA procedure characteristics as well as revision rates evinced some differences between the Netherlands and the Nordic countries. The Netherlands compared best with Denmark in terms of patient and procedure characteristics, but resembled Sweden more in terms of short-term revision risk. Combining data from registries like LROI and the NARA collaboration is feasible and might possibly enable tracking of potential outlier implants.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Prótese de Quadril/estatística & dados numéricos , Reoperação/estatística & dados numéricos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Padrões de Prática Médica , Países Escandinavos e Nórdicos
15.
Acta Orthop ; 92(2): 143-150, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33176549

RESUMO

Background and purpose - Uncemented stems are gradually replacing cemented stems in hip revision surgery. We compared the risk of re-revision between uncemented and cemented revision stems and assessed whether the different fixation methods are used in similar femoral bone defects.Patients and methods - 867 patients operated on with uncemented or cemented stems in first-time hip revision surgery due to aseptic loosening performed 2006-2016 were identified in the Swedish Hip Arthroplasty Register. Preoperative femoral bone defect size was assessed on radiographs of all patients. Cox regression models were fitted to estimate the adjusted risk of re-revision during different postoperative time periods. Re-revision of any component for any reason, and stem re-revision, as well as risk of cause-specific re-revision was estimated.Results - Most patients in both fixation groups had Paprosky class IIIA femoral bone defects prior to surgery, but there were more severe bone defects in the cemented group. The adjusted risk of re-revision of any component for any reason was higher in patients with uncemented compared with those with cemented revision stems during the first 3 years after index surgery (hazard ratio [HR] 4, 95% confidence interval [CI] 2-9). From the 4th year onward, the risk of re-revision of any component for any reason was similar (HR 0.5, CI 0.2-1.4). Uncemented revision stems conferred a higher risk of dislocation compared with cemented stems (HR 5, CI 1.2-23) during the first 3 years.Interpretation - Although not predominantly used in more complex femoral defects, uncemented revision stem fixation confers a slightly higher risk of re-revision during the first years, but this risk is attenuated after longer follow-up.


Assuntos
Artroplastia de Quadril/métodos , Cimentos Ósseos , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Reoperação/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade
16.
Acta Orthop ; 92(1): 47-53, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33143515

RESUMO

Background and purpose - Current literature indicates no difference in 90-day mortality after cemented compared with cementless total hip arthroplasty (THA). However, previous studies are hampered by potential selection bias and suboptimal adjustment for comorbidity confounding. Therefore, we examined the comorbidity-adjusted mortality up to 90 days after cemented compared with cementless THA performed due to osteoarthritis.Patients and methods - Using the Nordic Arthroplasty Register Association database, 2005-2013, we included 108,572 cemented and 80,034 cementless THA due to osteoarthritis. We calculated the Charlson comorbidity index of each patient based on data from national patient registers. The Kaplan-Meier method was used to estimate unadjusted all-cause mortality. Cox regression was used to estimate hazard ratios (HR) with 95% confidence intervals (CI) for 14, 30-, and 90-day mortality comparing cemented with cementless THA, adjusting for age, sex, comorbidity, nation, and year of surgery.Results - Cumulative all-cause mortality within 90 days was 0.41% (CI 0.37-0.46) after cemented and 0.26% (CI 0.22-0.30) after cementless THA. The adjusted HR for cemented vs. cementless fixation was 0.97 (CI 0.79-1.2), and similar risk estimates were obtained for mortality within 14 (adjusted HR 0.91 [CI 0.64-1.3]) and 30 days (adjusted HR 0.94 [CI 0.71-1.3]). We found no clinically relevant differences in mortality between cemented and cementless THA in analyses stratified by age, sex, Charlson comorbidity index, or year of surgery.Interpretation - After adjustment for comorbidity as an important confounder, we observed similar early mortality between the 2 fixation techniques.


Assuntos
Artroplastia de Quadril/mortalidade , Cimentação , Osteoartrite do Quadril/cirurgia , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Medição de Risco , Países Escandinavos e Nórdicos
17.
Bone Rep ; 13: 100715, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32995386

RESUMO

INTRODUCTION: Although the number of patients undergoing total hip arthroplasty is constantly on the rise, we only have limited knowledge of the molecular mechanisms necessary for successful osseointegration of implants or the reasons why some fail. Understanding the spatiotemporal characteristics of signaling pathways involved in bone healing of implants is therefore of particular importance for our ability to identify factors causing implants to fail. The current study investigated the role of three families of proteases, i.e. MMPs (matrix metalloproteinases), ADAMTS (a disintegrin and metalloproteinase with thrombospondin motifs) and serine proteases, as well as their endogenous inhibitors during osseointegration of hip implants that have endured two decades of use without clinical or radiological signs of loosening. MATERIALS AND METHODS: Twenty-four patients that had undergone primary THA due to one-sided osteoarthritis (OA) were monitored during 18 years (Y) with repeated measurements of plasma biomarkers, clinical variables and radiographs. All implants were clinically and radiographically well-fixed throughout the follow-up. Eighty-one healthy donors divided in three gender and age-matched groups and twenty OA patients awaiting THA, served as controls. Plasma was analyzed for MMP-1, -2, -3, -8, -9, -10, -13, -14, tissue inhibitor of metalloproteinase (TIMP)-1, -2, -3, ADAMTS4, ADAMTS5, the serine proteases neutrophil elastase (NE), proteinase 3 (PR3) and their endogenous inhibitors, secretory leucocyte proteinase inhibitor (SLPI), trappin-2/elafin and serpina1 (α-1 antitrypsin). Cartilage turnover was monitored using two markers of cartilage synthesis, type II procollagen and PIICP (procollagen II C-terminal propeptide), and two markers of cartilage degradation, CTX-II (C-terminal telopeptide fragments of type II collagen) and split products of aggrecan (G1-IGD-G2). RESULTS: MMP-1, MMP-9, ADAMTS4, NE and PR3 were above healthy in presurgery OA patients but returned to the level of healthy within 6 weeks (W) after surgery. MMPs and serine proteases were counter-regulated during this phase by TIMP-1, SLPI and trappin-2/elafin. Type II procollagen, PIICP and CTX-II increased to a peak 6 W after surgery with a gradual return to the level of controls within weeks. Significant increases by MMP-8, MMP-9, ADAMTS4, ADAMTS5, NE, PR3 and the protease inhibitors, TIMP-3 and serpina1, were seen 5 Y after hip arthroplasty paralleled by a sharp increase in the levels of the cartilage degradation markers, CTX-II and G1-IGD-G2. All the above mediators were normalized before 18 Y, except MMP-1 and MMP-9 that remained above healthy at 18 Y. MMP-14 increased immediately after surgery and remained elevated until 5 Y postsurgery before returning to the level of controls at 7 Y. CONCLUSION: Notwithstanding temporal differences, the molecular processes of bone repair in arthroplasty patients show great spatial similarities with the classical phases of fracture repair as previously shown in animal models. Cartilagenous callus, produced and remodeled early after hip arthroplasty, is replaced with bone 5 Y to7 Y after surgery by the concerted actions of MMP-8, MMP-9, ADAMTS4, ADAMTS5, NE and PR3, thus suggesting that a complex regulatory cross-talk may exist between different families of proteases during this transitional phase of cartilage degradation. Regulation and fine-tuning of cartilage remodeling by MMPs and ADAMTS is controlled by TIMP-3 whereas serine proteases are regulated by serpina1. Increased MMP-1 and MMP-9 beyond 10Y post-THA support a role during coupled bone remodeling.

18.
Acta Orthop ; 91(4): 401-407, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32285736

RESUMO

Background and purpose - 32-mm heads are widely used in total hip arthroplasty (THA) in Scandinavia, while the proportion of 36-mm heads is increasing as they are expected to increase THA stability. We investigated whether the use of 36-mm heads in THA after proximal femur fracture (PFF) is associated with a lower risk of revision compared with 32-mm heads.Patients and methods - We included 5,030 patients operated with THA due to PFF with 32- or 36-mm heads from the Nordic Arthroplasty Register Association database. Each patient with a 36-mm head was matched with a patient with a 32-mm head, using propensity score. The patients were operated between 2006 and 2016, with a metal or ceramic head on a polyethylene bearing. Cox proportional hazards models were fitted to estimate the unadjusted and adjusted hazard ratio (HR) with 95% confidence intervals (CI) for revision for any reason and revision due to dislocation for 36-mm heads compared with 32-mm heads.Results - 36-mm heads had an HR of 0.9 (CI 0.7-1.2) for revision for any reason and 0.8 (CI 0.5-1.3) for revision due to dislocation compared with 32-mm heads at a median follow-up of 2.5 years (interquartile range 1-4.4).Interpretation - We were not able to demonstrate any clinically relevant reduction of the risk of THA revision for any reason or due to dislocation when 36-mm heads were used versus 32-mm. Residual confounding due to lack of data on patient comorbidities and body mass index could bias our results.


Assuntos
Artroplastia de Quadril/efeitos adversos , Fraturas do Fêmur/cirurgia , Prótese de Quadril , Reoperação/estatística & dados numéricos , Idoso , Artroplastia de Quadril/métodos , Artroplastia de Quadril/estatística & dados numéricos , Feminino , Prótese de Quadril/efeitos adversos , Prótese de Quadril/estatística & dados numéricos , Humanos , Estimativa de Kaplan-Meier , Masculino , Modelos de Riscos Proporcionais , Falha de Prótese , Fatores de Risco , Fatores de Tempo
19.
Acta Orthop ; 91(3): 272-278, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32237930

RESUMO

Background and purpose - To better detect small changes in postoperative outcome following total hip replacement (THR), the Swedish Hip Arthroplasty Register (SHAR) has decided to change from the EQ-5D-3L (3L) to the EQ-5D-5L (5L). To enable comparison of results obtained with use of the 2 versions of EQ-5D, transferal of results between the questionnaires used is necessary. We assessed the measurement properties of the EQ-5D-5L compared with the EQ-5D-3L, preoperatively and 1-year postoperatively in a Swedish THR population.Patients and methods - Patients eligible for elective THR during 2015 in Western Sweden were invited to the study. With a 2-week separation, the 3L and 5L questionnaires were administered to patients before and 1 year after surgery. Comparing the 2 versions of the EQ-5D, we investigated redistribution of responses, ceiling and floor effects, EQ VAS correlations (Spearman's rank correlation coefficient, rs), and EQ VAS scores for different severity levels by dimension (univariable ordinary least square regression).Results - The additional severity levels of the 5L version were frequently used on both measurement occasions (preoperative mobility 5%, self-care 17%, usual activities 20%, pain 5% and anxiety 3%, postoperative mobility 6%, self-care 5%, usual activities 8%, pain 9%, and anxiety 5%). Ceiling effects of the 3L version diminished overall by 7% using the 5L version. The correlations between the 2 EQ VAS scores obtained with the 3L and 5L instruments were strong both pre- (rs = 0.71) and postoperatively (rs = 0.87). Estimated EQ VAS scores for different levels of severity were consistent for all dimensions except for the mobility dimension of the preoperative 5L version and the anxiety dimension in the postoperative 5L version.Interpretation - Our findings support that the 5L has a higher resolution than the 3L version regarding description of health-related quality of life in patients undergoing THR in Sweden. The EQ VAS scores for different levels of severity agree well between the EQ-5D versions. This could potentially be used to develop a crosswalk value set for transforming 3L to 5L responses in this patient group.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Inquéritos e Questionários , Idoso , Feminino , Humanos , Masculino , Suécia , Fatores de Tempo , Resultado do Tratamento
20.
J Hand Surg Am ; 45(8): 778.e1-778.e7, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32222268

RESUMO

PURPOSE: To assess the responsiveness of forearm strength tests and to correlate the change to grip strength and a patient-reported outcome measure used for evaluation of distal radioulnar joint (DRUJ) implant arthroplasty. METHODS: We performed a retrospective review of 18 patients treated with Herbert (n = 12) and Scheker (n = 6) DRUJ implants. Patients who had undergone the various measurements of arm and grip strength both before surgery and after a minimum follow-up of 1 year were included. Our primary aim was to compare the responsiveness of grip strength with our new methods for measuring forearm torque and lifting strength. The secondary aim was to correlate observed changes in strength measurements to change in a patient-reported outcome measure with use of the patient-reported wrist evaluation (PRWE). Measurements of grip strength, forearm torque, and lifting strength were performed with the Jamar dynamometer and the Kern and Baseline instruments. Preoperative values were compared with 1-year values. RESULTS: Standardized response mean and effect size values were higher for forearm torque than for grip strength. Change in forearm torque and lifting strength had a moderate to strong correlation with change in PRWE. The correlation between grip strength and PRWE was weak. CONCLUSIONS: Forearm torque measurements were better than grip strength in detecting changes after DRUJ arthroplasty. It also had a stronger correlation to patient-reported outcome, measured with the PRWE. CLINICAL RELEVANCE: Forearm torque testing may add further information to the evaluation of DRUJ disorders and their treatments. These tests can provide quantifiable data on the patient's ability to perform various tasks requiring physical strength.


Assuntos
Artroplastia de Substituição , Antebraço , Força da Mão , Humanos , Estudos Retrospectivos , Torque , Articulação do Punho/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA