Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Klin Padiatr ; 236(2): 64-72, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38262422

RESUMO

BACKGROUND: Pulmonary Alveolar Proteinosis (PAP) is extremely rare and can be caused by hereditary dysfunction of the granulocyte macrophage colony-stimulating factor receptor (GM-CSF) receptor, autoantibodies against GM-CSF, or other diseases leading to alveolar macrophage (AM) dysfunction. This leads to protein accumulation in the lung and severe dyspnea and hypoxemia. Whole lung lavage (WLL) is the first line treatment strategy. METHODS: Here, we present data from more than ten years of WLL practice in pediatric PAP. WLL performed by the use of a single lumen or double lumen tube (SLT vs. DLT) were compared for technical features, procedure time, and adverse events. RESULTS: A total of n=57 procedures in six PAP patients between 3.5 and 14.3 years of age were performed. SLT based WLL in smaller children was associated with comparable rates of adverse events but with longer intervention times and postprocedural intensive care treatment when compared to DLT based procedures. DISCUSSION: Our data shows that WLL is feasible even in small children. DLT based WLL seems to be more effective, and our data supports the notion that it should be considered as early as possible in pediatric PAP. CONCLUSION: WLL lavage is possible in small PAP patients but should performed in close interdisciplinary cooperation and with age appropriate protocols.


Assuntos
Proteinose Alveolar Pulmonar , Humanos , Criança , Proteinose Alveolar Pulmonar/diagnóstico , Proteinose Alveolar Pulmonar/terapia , Fator Estimulador de Colônias de Granulócitos e Macrófagos/uso terapêutico , Lavagem Broncoalveolar/métodos , Pulmão , Autoanticorpos
2.
Zentralbl Chir ; 148(3): 284-292, 2023 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-36167311

RESUMO

In recent years, the use of mechanical support for patients with cardiac or circulatory failure has continuously increased, leading to 3,000 ECLS/ECMO (extracorporeal life support/extracorporeal membrane oxygenation) implantations annually in Germany. Due to the lack of guidelines, there is an urgent need for evidence-based recommendations addressing the central aspects of ECLS/ECMO therapy. In July 2015, the generation of a guideline level S3 according to the standards of the Association of the Scientific Medical Societies in Germany (AWMF) was announced by the German Society for Thoracic and Cardiovascular Surgery (GSTCVS). In a well-structured consensus process, involving experts from Germany, Austria and Switzerland, delegated by 16 scientific societies and the patients' representation, the guideline "Use of extracorporeal circulation (ECLS/ECMO) for cardiac and circulatory failure" was created under guidance of the GSTCVS, and published in February 2021. The guideline focuses on clinical aspects of initiation, continuation, weaning and aftercare, herein also addressing structural and economic issues. This article presents an overview on the methodology as well as the final recommendations.


Assuntos
Oxigenação por Membrana Extracorpórea , Choque , Humanos , Sociedades Científicas , Circulação Extracorpórea , Sociedades Médicas , Alemanha
4.
Artigo em Alemão | MEDLINE | ID: mdl-35172345

RESUMO

Button battery ingestions in children increased in recent years and may lead to life-threatening complications, especially if the battery is impacted in the esophagus. The pH close to the negative pole of the battery can rise in a very alkalotic range (pH > 10) leading to severe tissue damage. Therefore, in this case series report, the clinical courses of four children with button battery ingestion leading to tracheoesophageal fistulas are presented. The diagnosis and removal of the button battery was delayed in all cases. The surgical reconstruction of the trachea was performed in intravenous anesthesia and with extended monitoring. The intraoperative oxygenation was maintained using a combination of extracorporeal membrane oxygenation (ECMO) and mechanical ventilation via an endobronchial tube. To prevent these life-threatening complications, the awareness of the parents and child care providers should be raised, and the manufacturers should redesign their products to secure the battery compartment. In children with suspected battery ingestions, the immediate localization and removal of the battery (< 2 h) is of highest importance. Local administration of honey or sucralfate can be considered in ingestions < 12 h but should not delay an endoscopic removal.


Assuntos
Anestesia , Corpos Estranhos , Fístula Traqueoesofágica , Anestesia/efeitos adversos , Ingestão de Alimentos , Fontes de Energia Elétrica/efeitos adversos , Corpos Estranhos/cirurgia , Humanos , Fístula Traqueoesofágica/etiologia , Fístula Traqueoesofágica/cirurgia
5.
Klin Padiatr ; 234(5): 293-300, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34979579

RESUMO

BACKGROUND: Persistent air leak (PAL) is a severe complication of secondary spontaneous pneumothorax (SSP). Surgical interventions are usually successful when medical treatment fails, but can be associated with significant complications and loss of potentially recoverable lung parenchyma. METHODS: Retrospective analysis of efficacy and safety of interventional bronchus occlusions (IBO) using Amplatzer devices (ADs) in children with PAL secondary to SSP. RESULTS: Six patients (four males, 4-15 years of age) underwent IBO using ADs as treatment for PAL. Necrotizing pneumonia (NP) was the most common cause (n=4) of PAL. Three patients were previously healthy and three suffered from chronic lung disease. All patients required at least two chest tubes prior to the intervention for a duration of 15-43 days and all required oxygen or higher level of ventilatory support. In three cases, previous surgical interventions had been performed without success. All children improved after endobronchial intervention and we observed no associated complications. All chest tubes were removed within 5-25 days post IBO. In patients with PAL related to NP (n=4), occluders were removed bronchoscopically without re-occurrence of pneumothorax after a mean of 70 days (IQR: 46.5-94). CONCLUSION: IBO using ADs is a safe and valuable treatment option in children with PAL independent of disease severity and underlying cause. A major advantage of this procedure is its less invasiveness compared to surgery and the parenchyma- preserving approach.


Assuntos
Pneumotórax , Complicações Pós-Operatórias , Brônquios/cirurgia , Tubos Torácicos/efeitos adversos , Criança , Humanos , Masculino , Oxigênio , Pneumotórax/cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Estudos Retrospectivos
6.
Anaesthesist ; 70(11): 942-950, 2021 11.
Artigo em Alemão | MEDLINE | ID: mdl-34665266

RESUMO

In Germany, a remarkable increase regarding the usage of extracorporeal membrane oxygenation (ECMO) and extracorporeal life support (ECLS) systems has been observed in recent years with approximately 3000 ECLS/ECMO implantations annually since 2015. Despite the widespread use of ECLS/ECMO, evidence-based recommendations or guidelines are still lacking regarding indications, contraindications, limitations and management of ECMO/ECLS patients. Therefore in 2015, the German Society of Thoracic and Cardiovascular Surgery (GSTCVS) registered the multidisciplinary S3 guideline "Use of extracorporeal circulation (ECLS/ECMO) for cardiac and circulatory failure" to develop evidence-based recommendations for ECMO/ECLS systems according to the requirements of the Association of the Scientific Medical Societies in Germany (AWMF). Although the clinical application of ECMO/ECLS represents the main focus, the presented guideline also addresses structural and economic issues. Experts from 17 German, Austrian and Swiss scientific societies and a patients' organization, guided by the GSTCVS, completed the project in February 2021. In this report, we present a summary of the methodological concept and tables displaying the recommendations for each chapter of the guideline.


Assuntos
Oxigenação por Membrana Extracorpórea , Choque , Circulação Extracorpórea , Alemanha , Humanos , Sistemas de Manutenção da Vida
7.
Med Klin Intensivmed Notfmed ; 116(8): 678-686, 2021 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-34665281

RESUMO

In Germany, a remarkable increase regarding the usage of extracorporeal membrane oxygenation (ECMO) and extracorporeal life support (ECLS) systems has been observed in recent years with approximately 3000 ECLS/ECMO implantations annually since 2015. Despite the widespread use of ECLS/ECMO, evidence-based recommendations or guidelines are still lacking regarding indications, contraindications, limitations and management of ECMO/ECLS patients. Therefore in 2015, the German Society of Thoracic and Cardiovascular Surgery (GSTCVS) registered the multidisciplinary S3 guideline "Use of extracorporeal circulation (ECLS/ECMO) for cardiac and circulatory failure" to develop evidence-based recommendations for ECMO/ECLS systems according to the requirements of the Association of the Scientific Medical Societies in Germany (AWMF). Although the clinical application of ECMO/ECLS represents the main focus, the presented guideline also addresses structural and economic issues. Experts from 17 German, Austrian and Swiss scientific societies and a patients' organization, guided by the GSTCVS, completed the project in February 2021. In this report, we present a summary of the methodological concept and tables displaying the recommendations for each chapter of the guideline.


Assuntos
Oxigenação por Membrana Extracorpórea , Choque , Circulação Extracorpórea , Alemanha , Humanos , Sistemas de Manutenção da Vida
8.
J Card Surg ; 36(12): 4551-4557, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34595768

RESUMO

BACKGROUND: Despite considerable progress in heart transplantation, pediatric waiting list mortality is still high, and often patients do not have enough time to wait. We hypothesized that extending the donor criteria regarding age and weight mismatch does not significantly affect the early follow-up. METHODS: We retrospectively analyzed our pediatric heart transplantation patients operated on from 2014 to 2020 for high (>3.0) or low (<0.6) donor-recipient weight ratio (DRWR) or chronological age mismatches (donor organ >5 years older than recipient age). This patient cohort constituted "mismatched heart transplantations" (mHTX). We compared mHTX preoperative status, postoperative course, 1-year survival, and early clinical follow-up to standard pediatric heart transplantations (sHTX). RESULTS: We performed 20 pediatric heart transplantations-10 mHTX and 10 sHTX. The minimum DRWR was 0.44, the maximum was 5.60, and the maximum age mismatch was 42.6 years. Median days in the intensive care unit (p = .436) and time-to-first-rejection episode (p = .925) were comparable. Nine patients in each group were alive after 1 year, two patients were operated within 1 year of follow-up. One mHTX patient developed cardiac allograft vasculopathy after 15 months and died 648 days after transplantation (p = .237). All other patients were alive at the end of follow-up and in good clinical conditions (median follow-up for mHTX was 732.5 days, 1149.5 days for sHTX). CONCLUSION: Postoperative course and early follow-up after mHTX were comparable to sHTX. In urgent clinical situations, extended donor criteria may be considered an additional option for pediatric heart transplantation.


Assuntos
Transplante de Coração , Listas de Espera , Adulto , Criança , Pré-Escolar , Estudos de Coortes , Humanos , Estudos Retrospectivos , Doadores de Tecidos
9.
Pediatr Cardiol ; 36(6): 1270-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25845941

RESUMO

Cardiac surgery with cardiopulmonary bypass (CPB) frequently leads to systemic inflammatory response syndrome (SIRS) with concomitant organ malfunction. Infused particles may exacerbate inflammatory syndromes since they activate the coagulation cascade and alter inflammatory response or microvascular perfusion. In a randomized, controlled, prospective trial, we have previously shown that particle-retentive in-line filtration prevented major complications in critically ill children. Now, we investigated the effect of in-line filtration on major complications in the subgroup of cardiac patients. Children admitted to tertiary pediatric intensive care unit were randomized to either control or filter group obtaining in-line filtration throughout complete infusion therapy. Risk differences and 95 % confidence intervals (CI) of several complications such as SIRS, sepsis, mortality, various organ failure and dysfunction were compared between both groups using the Wald method. 305 children (n = 150 control, n = 155 filter group) with cardiac diseases were finally analyzed. The majority was admitted after cardiac surgery with CPB. Risk of SIRS (-11.3 %; 95 % CI -21.8 to -0.5 %), renal (-10.0 %; 95 % CI -17.0 to -3.0 %) and hematologic (-8.1 %; 95 % CI -14.2 to -0.2 %) dysfunction were significantly decreased within the filter group. No risk differences were demonstrated for occurrence of sepsis, any other organ failure or dysfunctions between both groups. Infused particles might aggravate a systemic hypercoagulability and inflammation with subsequent organ malfunction in pediatric cardiac intensive care patients. Particle-retentive in-line filtration might be effective in preventing SIRS and maintaining renal and hematologic function. In-line filtration offers a novel therapeutic option to decrease morbidity in cardiac intensive care.


Assuntos
Ponte Cardiopulmonar/efeitos adversos , Cuidados Críticos/métodos , Contaminação de Medicamentos/prevenção & controle , Filtração/métodos , Infusões Intravenosas/métodos , Síndrome de Resposta Inflamatória Sistêmica/prevenção & controle , Adolescente , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Infusões Intravenosas/instrumentação , Unidades de Terapia Intensiva Pediátrica , Tempo de Internação/estatística & dados numéricos , Masculino , Insuficiência de Múltiplos Órgãos/prevenção & controle , Material Particulado/efeitos adversos , Estudos Prospectivos , Fatores de Risco , Sepse/prevenção & controle , Síndrome de Resposta Inflamatória Sistêmica/complicações , Síndrome de Resposta Inflamatória Sistêmica/etiologia , Síndrome de Resposta Inflamatória Sistêmica/mortalidade , Trombofilia/prevenção & controle , Resultado do Tratamento
10.
Pediatr Cardiol ; 33(4): 625-32, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22349665

RESUMO

Especially in critically ill children with cardiac diseases, fluid management and monitoring of cardiovascular function are essential. Ultrasound dilution technique (UDT) was recently introduced to measure cardiac output (CO) and volumetric parameters, such as intrathoracic and end-diastolic blood volume. We compared UDT with the well-established transpulmonary thermodilution (TPTD) method (PiCCO) for determining CO measurements and derived volumes in a juvenile animal model. Experiments were performed in 18 ventilated, anesthetized piglets during normovolemia and after isovolemic hemodilution. At baseline and 20 min after each step of isovolemic hemodilution, 3 independent measurements of CO and volumetric parameters were conducted with TPTD and UDT, consecutively, under hemodynamically stable conditions. We observed comparable results for CO measurements with both methods (mean 1.98 l/min; range 1.12-2.87) with a percentage error of 17.3% (r = 0.92, mean bias = 0.28 l/min). Global end-diastolic volume (GEDV) and intrathoracic blood volume (ITBV) by TPTD were almost two times greater than analogous volumes [central blood volume (CBV); total end-diastolic volume (TEDV)] quantified by UDT (CBV = 0.58 × ITBV + 27.1 ml; TEDV = 0.48 × GEDV + 23.1 ml). CO measurements by UDT were found to be equivalent and hence interchangeable with TPTD. Discrepancies in volumetric parameters could either be due to the underlying algorithm or different types of indicators (diffusible vs. nondiffusible). Compared with the anatomically defined heart volume, TPTD seems to overestimate end-diastolic volumes. Future studies will be necessary to assign these results to critically ill children and to validate volumetric parameters with reference techniques.


Assuntos
Volume Sanguíneo/fisiologia , Volume Cardíaco/fisiologia , Doenças Cardiovasculares/diagnóstico , Monitorização Fisiológica/métodos , Contração Miocárdica/fisiologia , Termodiluição/métodos , Animais , Débito Cardíaco , Doenças Cardiovasculares/fisiopatologia , Estado Terminal , Diástole , Modelos Animais de Doenças , Feminino , Reprodutibilidade dos Testes , Suínos
11.
Am J Transplant ; 4(12): 2102-8, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15575915

RESUMO

Adenoviral (AdV) infections after transplantation remain a challenge in pediatric patients. Qualitative and quantitative PCR offer new approaches to early diagnosis and monitoring. However, their role in the management of AdV infections in pediatric transplant recipients remains to be determined. We report six children with positive qualitative serum-PCR for AdV on routine follow-up after transplantation (liver n = 4, hematopoetic stem cells (HSCT) n = 1, combined liver and HSCT n = 1). None of these children were symptomatic at the time of first detection of AdV. Two patients remained asymptomatic, one developed hemorrhagic cystitis and enteritis. Three children with positive PCR developed high viral load on quantitative PCR, all developed clinical AdV sepsis with further rising virus load. Despite antiviral therapy with cidofovir, these three patients died of septic multiorgan failure. Positive qualitative AdV-PCR from blood after pediatric transplantation is not necessarily followed by clinical disease. In case of positive AdV-PCR, monitoring by serial quantitative PCR is useful regarding treatment decision and prevention of fatal disease.


Assuntos
Infecções por Adenoviridae/diagnóstico , Infecções por Adenoviridae/etiologia , Transplante de Fígado , Transplante de Células-Tronco , Adolescente , Sequência de Bases , Criança , Pré-Escolar , Primers do DNA , Humanos , Lactente , Reação em Cadeia da Polimerase/métodos , Reoperação , Estudos Retrospectivos , Falha de Tratamento , Resultado do Tratamento
12.
Pacing Clin Electrophysiol ; 27(7): 924-32, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15271011

RESUMO

Appropriate and inappropriate therapies of implantable cardioverter defibrillators have a major impact on morbidity and quality of life in ICD recipients, but have not been systematically studied in children and young adults during long-term follow-up. ICD implantation was performed in 20 patients at the mean age of 16 +/- 6 years, 11 of which had prior surgical repair of a congenital heart defect, 9 patients had other cardiac diseases. Implant indications were aborted sudden cardiac death in six patients, recurrent ventricular tachycardia in 9 patient, and syncope in 5 patients. Epicardial implantation was performed in 6 and transvenous implantation in 14 patients. Incidence, reasons and predictors (age, gender, repaired congenital heart disease, history of supraventricular tachycardia, and epicardial electrode system) of appropriate and inappropriate ICD therapies were analyzed during a mean follow-up period of 51 +/- 31 months range 18-132 months. There were a total 239 ICD therapies in 17 patients (85%) with a therapy rate of 2.8 per patient-years of follow-up. 127 (53%) ICD therapies in 15 (75%) patients were catagorized as appropriate and 112 (47%) therapies in 10 (50%) patients as inappropriate, with a rate of 1.5 appropriate and 1.3 inappropriate ICD therapies per patient-years of follow-up. Time to first appropriate therapy was 16 +/- 18 months. Appropriate therapies were caused by ventricular fibrillation in 29 and ventricular tachycardia in 98 episodes. Termination was successful by antitachycardia pacing in 4 (3%) and by shock therapy in 123 episodes (97%). Time to first inappropriate therapy was 16 +/- 17 months. Inappropriate therapies were caused by supraventricular tachycardia in 77 (69%), T wave oversensing in 19 (17%), and electrode defect in 16 episodes (14%). It caused shocks in 87 (78%) and only antitachycardia pacing in 25 episodes (22%). No clinical variable could be identified as predictor of either appropriate or inappropriate ICD therapies. There is a high rate of ICD therapies in young ICD recipients, the majority of which occur during early follow-up. The rate of inappropriate therapies is as high as 47% and is caused by supraventricular tachycardia and electrode complications in the majority of cases. Prospective trials are required to establish preventative strategies of ICD therapies in this young patient population.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/estatística & dados numéricos , Adolescente , Adulto , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Fibrilação Atrial/etiologia , Fibrilação Atrial/terapia , Criança , Desfibriladores Implantáveis/efeitos adversos , Eletrocardiografia , Humanos , Fatores de Risco , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Procedimentos Desnecessários , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA