2.
Diagnostics (Basel) ; 14(6)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38535076

RESUMO

BACKGROUND AND AIMS: Endoscopic retrograde cholangiopancreatography (ERCP) procedures can result in significant patient radiation exposure. This retrospective multicenter study aimed to assess the influence of procedural complexity and other clinical factors on radiation exposure in ERCP. METHODS: Data on kerma-area product (KAP), air-kerma at the reference point (Ka,r), fluoroscopy time, and the number of exposures, and relevant patient, procedure, and operator factors were collected from 2641 ERCP procedures performed at four university hospitals. The influence of procedural complexity, assessed using the American Society for Gastrointestinal Endoscopy (ASGE) and HOUSE complexity grading scales, on radiation exposure quantities was analyzed within each center. The procedures were categorized into two groups based on ERCP indications: primary sclerosing cholangitis (PSC) and other ERCPs. RESULTS: Both the ASGE and HOUSE complexity grading scales had a significant impact on radiation exposure quantities. Remarkably, there was up to a 50-fold difference in dose quantities observed across the participating centers. For non-PSC ERCP procedures, the median KAP ranged from 0.9 to 64.4 Gy·cm2 among the centers. The individual endoscopist also had a substantial influence on radiation dose. CONCLUSIONS: Procedural complexity grading in ERCP significantly affects radiation exposure. Higher procedural complexity is typically associated with increased patient radiation dose. The ASGE complexity grading scale demonstrated greater sensitivity to changes in radiation exposure compared to the HOUSE grading scale. Additionally, significant variations in dose indices, fluoroscopy times, and number of exposures were observed across the participating centers.

3.
Eur J Vasc Endovasc Surg ; 67(3): 435-443, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37611731

RESUMO

OBJECTIVE: To compare the protective effect of Zero Gravity (ZG) with conventional radiation protection during endovascular aneurysm repair (EVAR). Secondly, user experience was surveyed with a questionnaire on ergonomics. METHODS: This was a single centre, prospective, randomised, two arm trial where 71 consecutive elective infrarenal EVAR procedures were randomised into two groups: (1) operator using ZG and assistant using conventional protection (n = 36), and (2) operator and assistant using conventional radiation protection (n = 35). A movable floor unit ZG system consists of a lead shield (1.0 mm Pb equivalent) for the front of the body and 0.5 mm Pb equivalent acrylic shielding for the head and neck. The ZG also includes arm flaps of 0.5 mm Pb equivalent covering the arm up to the elbow. Deep dose equivalent values, Hp(10) were measured with direct ion storage dosimeters (DIS) placed on various anatomical regions of the operator (axilla, chest, abdomen, and lower leg). Personal dose equivalent values, Hp(3) to eye lenses were measured in the operating and assisting surgeon using thermoluminescence dosimeters. The study was registered at the US National Institute of Health #NCT04078165. RESULTS: Protection with the standard protection was superior in chest (0.0 vs. 0.1 µSv), abdomen (0.0 vs. 0.6 µSv), and lower leg (0.4 vs. 2.2 µSv) (p < .001). On the other hand, the ZG system yielded better shielding for the axilla (1.5 vs. 0.0 µSv) and eyes (6.3 vs. 1.1 µSv) of the operator. The use of ZG hampered the deployment of ancillary shields, which is particularly relevant for protection of the assisting surgeon. Users found ZG more cumbersome than conventional garments, it also impaired communication and reduced field of view. CONCLUSION: Both ZG and conventional radiation protection reduced radiation exposure. Conventional protection allows better manoeuvrability at the price of wider exposure of the upper arm and axilla. ZG indirectly impaired protection of the assistant.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Exposição Ocupacional , Proteção Radiológica , Humanos , Proteção Radiológica/métodos , Correção Endovascular de Aneurisma , Doses de Radiação , Estudos Prospectivos , Chumbo , Exposição Ocupacional/prevenção & controle , Radiografia Intervencionista
4.
Endosc Int Open ; 11(3): E237-E246, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36910845

RESUMO

Background and study aims Endoscopic retrograde cholangiopancreatography (ERCP) procedures may result in remarkable radiation doses to patients and staff. The aim of this prospective study was to determine occupational exposures in gastrointestinal endoscopy procedures, with a special emphasis on eye lens dose in ERCP. Methods Altogether 604 fluoroscopy-guided procedures, of which 560 were ERCPs belonging to four American Society for Gastrointestinal Endoscopy procedural complexity levels, were performed using two fluoroscopy systems. Personal deep-dose equivalent H p (10), shallow-dose equivalent H p (0.07), and eye lens dose equivalent H p (3) of eight interventionists and H p (3) for two nurse dosimeters were measured. Thereafter, conversion coefficients from kerma-area product (KAP) for H p (10), H p (0.07), and H p (3) were determined and dose equivalents per procedure to an operator and assisting staff were estimated. Further, mean conversion factors from H p (10) and H p (0.07) to H p (3) were calculated. Results The median KAP in ERCP was 1.0 Gy·cm 2 , with mobile c-arm yielding higher doses than a floor-mounted device ( P  < 0.001). The median H p (3) per ERCP was estimated to be 0.6 µSv (max. 12.5 µSv) and 0.4 µSv (max. 12.2 µSv) for operators and assisting staff, respectively. The median H p (10) and H p (0.07) per procedure ranged from 0.6 to 1.8 µSv. ERCP procedural complexity level ( P  ≤ 0.002) and interventionist ( P  < 0.001) affected dose equivalents. Conclusions Occupational dose limits are unlikely to be exceeded in gastrointestinal endoscopy practice when following radiation-hygienic working methods and focusing on dose optimization. The eye lens dose equivalent H p (3) may be estimated with sufficient agreement from the H p (10) and H p (0.07).

5.
Pediatr Radiol ; 53(8): 1704-1712, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36967418

RESUMO

BACKGROUND: When postoperative multi-slice computed tomography (MSCT) imaging of patients with craniosynostosis is used, it is usually performed a few days after surgery in a radiology department. This requires additional anesthesia for the patient. Recently, intraoperative mobile cone-beam CT (CBCT) devices have gained popularity for orthopedic and neurosurgical procedures, which allows postoperative CT imaging in the operating room. OBJECTIVE: This single-center retrospective study compared radiation dose and image quality of postoperative imaging performed using conventional MSCT scanners and O-arm CBCT. MATERIALS AND METHODS: A total of 104 pediatric syndromic and non-syndromic patients who were operated on because of single- or multiple-suture craniosynostosis were included in this study. The mean volumetric CT dose index (CTDIvol) and dose-length product (DLP) values of optimized craniosynostosis CT examinations (58 MSCT and 46 CBCT) were compared. Two surgeons evaluated the subjective image quality. RESULTS: CBCT resulted in significantly lower CTDIvol (up to 14%) and DLP (up to 33%) compared to MSCT. Multi-slice CT image quality was considered superior to CBCT scans. However, all scans were considered to be of sufficient quality for diagnosis. CONCLUSION: The O-arm device allowed for an immediate postoperative CBCT examination in the operating theater using the same anesthesia induction. Radiation exposure was lower in CBCT compared to MSCT scans, thus further encouraging the use of O-arms. Cone-beam CT imaging with an O-arm is a feasible method for postoperative craniosynostosis imaging, yielding less anesthesia to patients, lower health costs and the possibility to immediately evaluate results of the surgical operation.


Assuntos
Craniossinostoses , Cirurgia Assistida por Computador , Humanos , Criança , Tomografia Computadorizada por Raios X/métodos , Imageamento Tridimensional/métodos , Estudos Retrospectivos , Doses de Radiação , Imagens de Fantasmas , Tomografia Computadorizada de Feixe Cônico/métodos , Craniossinostoses/diagnóstico por imagem , Craniossinostoses/cirurgia , Tomografia Computadorizada Multidetectores/métodos
6.
Acta Radiol ; 64(5): 1799-1807, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36437753

RESUMO

BACKGROUND: Previous studies have shown differences in technical image quality between digital breast tomosynthesis (DBT) systems. However, quantitative image quality measurements may not necessarily fully reflect the clinical performance of DBT. PURPOSE: To study the subjective image quality of five DBT systems manufactured by Fujifilm, GE, Hologic, Planmed, and Siemens using phantom images. MATERIAL AND METHODS: A TOR MAM test object with polymethyl methacrylate plates was imaged on five DBT systems from different vendors. Three DBT acquisitions were performed at mean glandular doses of 1.0 mGy, 2.0 mGy, and 3.5 mGy while maintaining a constant phantom set-up. Eight DBT acquisitions with different test plate positions and phantom set-up thicknesses were performed at clinically applied dose levels. Additionally, three conventional two-dimensional mammogram images were acquired with different phantom thicknesses. Six radiologists ranked the systems based on the visibilities of the targets seen in the phantom images. RESULTS: In the DBT acquisitions performed at comparable dose levels, one system differed significantly from all other systems in microcalcification scores. When using site-specific DBT protocols, significant differences were found between the devices for microcalcification, filament, and low-contrast targets. A strong correlation was observed between the reviewer scores and radiation doses in DBT acquisitions, whereas no such correlation was observed in the 2D acquisitions. CONCLUSION: In DBT acquisitions, dose level was found to be a major factor explaining image quality differences between the systems, regardless of other acquisition parameters. Most DBT systems performed equally well at similar dose levels.


Assuntos
Mamografia , Imagens de Fantasmas , Mamografia/instrumentação , Mamografia/métodos , Mamografia/normas , Radiologistas , Calcinose , Mama/diagnóstico por imagem , Humanos , Feminino
7.
BMC Med Imaging ; 22(1): 216, 2022 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-36476319

RESUMO

BACKGROUND: Visual evaluation of phantom images is an important, but time-consuming part of mammography quality control (QC). Consistent scoring of phantom images over the device's lifetime is highly desirable. Recently, convolutional neural networks (CNNs) have been applied to a wide range of image classification problems, performing with a high accuracy. The purpose of this study was to automate mammography QC phantom scoring task by training CNN models to mimic a human reviewer. METHODS: Eight CNN variations consisting of three to ten convolutional layers were trained for detecting targets (fibres, microcalcifications and masses) in American College of Radiology (ACR) accreditation phantom images and the results were compared with human scoring. Regular and artificially degraded/improved QC phantom images from eight mammography devices were visually evaluated by one reviewer. These images were used in training the CNN models. A separate test set consisted of daily QC images from the eight devices and separately acquired images with varying dose levels. These were scored by four reviewers and considered the ground truth for CNN performance testing. RESULTS: Although hyper-parameter search space was limited, an optimal network depth after which additional layers resulted in decreased accuracy was identified. The highest scoring accuracy (95%) was achieved with the CNN consisting of six convolutional layers. The highest deviation between the CNN and the reviewers was found at lowest dose levels. No significant difference emerged between the visual reviews and CNN results except in case of smallest masses. CONCLUSION: A CNN-based automatic mammography QC phantom scoring system can score phantom images in a good agreement with human reviewers, and can therefore be of benefit in mammography QC.


Assuntos
Redes Neurais de Computação , Humanos , Controle de Qualidade
8.
J Am Heart Assoc ; 11(11): e024257, 2022 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-35658507

RESUMO

Background Some myocardial diseases, such as cardiac sarcoidosis, predispose to complete atrioventricular block. The European Society of Cardiology Guidelines on cardiac pacing in 2021 recommend myocardial disease screening in patients with conduction disorder requiring pacemaker with multimodality imaging, including cardiac magnetic resonance (CMR) imaging. The ability of CMR imaging to detect myocardial disease in patients with a temporary pacing wire is not well documented. Methods and Results Our myocardial disease screening protocol is based on using an active fixation pacing lead connected to a reusable extracorporeal pacing generator (temporary permanent pacemaker) as a bridge to a permanent pacemaker. From 2011 to 2019, we identified 17 patients from our CMR database who underwent CMR imaging with a temporary permanent pacemaker for atrioventricular block. We analyzed their clinical presentations, CMR data, and pacemaker therapy. All CMRs were performed without adverse events. Pacing leads induced minor artifacts to the septal myocardial segments. The extent of late gadolinium enhancement in CMR imaging was used to screen patients for the presence of myocardial disease. Patients with evidence of late gadolinium enhancement underwent endomyocardial biopsy. If considered clinically indicated, also 18-F-fluorodeoxyglucose positron emission tomography and extracardiac tissue biopsy were performed if sarcoidosis was suspected. Eventually, 8 of 17 patients (47.1%) were diagnosed with histologically confirmed granulomatous inflammatory cardiac disease. Importantly, only 1 had a previously diagnosed extracardiac sarcoidosis at the time of presentation with high-degree atrioventricular block. Conclusions CMR imaging with temporary permanent pacemaker protocol is an effective and safe early screening tool for myocardial disease in patients presenting with atrioventricular block requiring immediate, continuous pacing for bradycardia.


Assuntos
Bloqueio Atrioventricular , Cardiomiopatias , Miocardite , Sarcoidose , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Cardiomiopatias/diagnóstico , Cardiomiopatias/diagnóstico por imagem , Meios de Contraste , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Sarcoidose/diagnóstico , Sarcoidose/diagnóstico por imagem
9.
BMC Med Imaging ; 21(1): 2, 2021 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-33407232

RESUMO

BACKGROUND: Cone-beam computed tomography (CBCT) has become an increasingly important medical imaging modality in orthopedic operating rooms. Metal implants and related image artifacts create challenges for image quality optimization in CBCT. The purpose of this study was to develop a robust and quantitative method for the comprehensive determination of metal artifacts in novel CBCT applications. METHODS: The image quality of an O-arm CBCT device was assessed with an anthropomorphic pelvis phantom in the presence of metal implants. Three different kilovoltage and two different exposure settings were used to scan the phantom both with and without the presence of metal rods. RESULTS: The amount of metal artifact was related to the applied CBCT imaging protocol parameters. The size of the artifact was moderate with all imaging settings. The highest applied kilovoltage and exposure level distinctly increased artifact severity. CONCLUSIONS: The developed method offers a practical and robust way to quantify metal artifacts in CBCT. Changes in imaging parameters may have nonlinear effects on image quality which are not anticipated based on physics.


Assuntos
Artefatos , Metais , Monitorização Intraoperatória/métodos , Procedimentos Ortopédicos , Próteses e Implantes , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Imagens de Fantasmas
10.
Eur J Vasc Endovasc Surg ; 59(4): 654-660, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32061447

RESUMO

OBJECTIVE: To quantify the effects of different imaging settings on radiation exposure to the operator and surgical team in a hybrid operating room (OR). METHODS: Measurements to determine scatter radiation in different imaging and geometry settings using an anthropomorphic phantom were performed in a hybrid OR equipped with a robotic C arm interventional angiography system (Artis Zeego; Siemens Healthcare, Erlangen, Germany). The radiation dose (RD) was measured with seven calibrated Philips DoseAware active electronic dosimeters and a Raysafe Xi survey detector, which were placed at different locations in the hybrid OR. The evaluated set ups included low dose, medium dose, and high dose fluoroscopy for abdomen; fluoroscopy fade; roadmap; and digital subtraction angiography (DSA), all using 20 s exposures. The effect of magnification, tube angulation, field size, source to skin distance, and RADPAD protection shields were assessed. Finally RD during cone beam computed tomography (CBCT) was obtained. RESULTS: In the operator position the initial settings with low dose fluoroscopy caused a RD of 1.03 µGy. The use of fluorofade did not increase the radiation dose (1.02 µGy), whereas the roadmap increased it threefold (2.84 µGy). The RD with "normal fluoro" was 4.13 µGy and increased to 6.44 µGy when high dose fluoroscopy mode was used. Magnification or field size varying from 42 cm to 11 cm led the RD to change from 0.86 µGy to 2.10 µGy. Decreasing the field of view to 25% of the initial size halved the RD (0.48 µGy). The RDs for the left anterior oblique 30° and right anterior oblique 30° were 3.26 µGy and 1.63 µGy, respectively. DSA increased the cumulative dose 33 fold but the RADPAD shield decreased the DSA RD to 4.92 µGy. The RD for CBCT was 47.2 µGy. CONCLUSION: Radiation exposure to operator and personnel can be significantly reduced during hybrid procedures with proper radiation protection and dose optimisation. A set of six behavioural rules were established.


Assuntos
Exposição Ocupacional/prevenção & controle , Doses de Radiação , Dosímetros de Radiação , Proteção Radiológica , Angiografia Digital/métodos , Procedimentos Endovasculares/métodos , Humanos , Salas Cirúrgicas , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/métodos
11.
Phys Med ; 63: 122-130, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31221403

RESUMO

BACKGROUND: Digital breast tomosynthesis (DBT) is a three-dimensional breast imaging method. DBT vendors employ various approaches in both image acquisition and data processing, which may affect image quality and radiation exposure to patients. OBJECTIVE: This study aimed to evaluate the performance of five DBT systems: Fujifilm Amulet Innovality (using both a standard mode and high-resolution mode), GE Senographe Essential, Hologic Selenia Dimensions, Planmed Clarity 3D, and Siemens Mammomat Inspiration. MATERIALS AND METHODS: The performance of each device and imaging technique was evaluated and compared by phantom measurements performed with four quality assurance phantoms. Technical image quality assessments consisted of measuring artefact extent, in-plane resolution, relative noise power spectrum, and geometric accuracy. RESULTS: Artefact spreading varied remarkably between the devices, and the full width at half maximum values of artefact spread functions varied from 3.5 mm to 10.7 mm. Noticeable in-plane resolution anisotropy, determined using modulation transfer function (MTF) analysis, was typically observed between tube travel direction and chest wall-nipple direction. The MTF50 varied from 1.1 mm-1 to 1.6 mm-1 and from 1.5 mm-1 to 4.1 mm-1 in the tube travel and chest wall-nipple directions, respectively. Moreover, distinctly different noise power spectra were observed between the systems. The geometric accuracy in every system was within 0.5%. CONCLUSION: Technical image quality assessments with image quality phantoms revealed remarkable differences in artefact spread, in-plane resolution, and noise properties between the DBT systems and imaging methods.


Assuntos
Mamografia/instrumentação , Imagens de Fantasmas , Artefatos , Controle de Qualidade , Razão Sinal-Ruído
12.
Int J Cardiovasc Imaging ; 35(2): 351-358, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30848402

RESUMO

Gelsolin (AGel) amyloidosis is a hereditary condition with common neurological effects. Myocardial involvement, especially strain, T1, or extracellular volume (ECV), in this disease has not been investigated before. Local myocardial effects and possible amyloid accumulation were the targets of interest in this study. Fifty patients with AGel amyloidosis were enrolled in the study. All patients underwent cardiovascular magnetic resonance imaging, including cine imaging, T1 mapping, tagging, and late gadolinium enhancement (LGE) imaging at 1.5 T. Results for volumetry, myocardial feature-tracking strain, rotation, torsion, native T1, ECV, and LGE were investigated. The population mean native T1 values in different segments of the left ventricle (LV) varied between 1003 and 1080 ms. Myocardial mean T1 was 1031 ± 37 ms. T1 was highest in the basal plane of the LV (1055 ± 40 ms), similarly to ECV (30.0% ± 4.4%). ECV correlated with native T1 in all LV segments (p < 0.005). Basal LGE was detected in 76% of patients, and mid-ventricular LGE in 32%. LV longitudinal strain was impaired (- 17.4% ± 2.6%), significantly decreasing apical rotation (p = 0.018) and concurrently myocardial torsion (p = 0.005). LV longitudinal strain correlated with mean T1 and ECV of different LV planes (p < 0.04; basal p < 0.01). Myocardial involvement in AGel amyloidosis is significant, but the effects are local, focusing on the basal plane of the LV.


Assuntos
Amiloidose/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Distrofias Hereditárias da Córnea/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Contração Miocárdica , Função Ventricular Esquerda , Amiloidose/genética , Amiloidose/patologia , Amiloidose/fisiopatologia , Fenômenos Biomecânicos , Cardiomiopatias/genética , Cardiomiopatias/patologia , Cardiomiopatias/fisiopatologia , Distrofias Hereditárias da Córnea/genética , Distrofias Hereditárias da Córnea/patologia , Distrofias Hereditárias da Córnea/fisiopatologia , Gelsolina/genética , Predisposição Genética para Doença , Humanos , Mutação , Miocárdio/patologia , Fenótipo , Valor Preditivo dos Testes , Estudos Prospectivos , Sistema de Registros , Volume Sistólico , Função Ventricular Direita
13.
Acta Radiol ; 60(2): 140-148, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29768928

RESUMO

BACKGROUND: The high requirements for mammography image quality necessitate a systematic quality assurance process. Digital imaging allows automation of the image quality analysis, which can potentially improve repeatability and objectivity compared to a visual evaluation made by the users. PURPOSE: To develop an automatic image quality analysis software for daily mammography quality control in a multi-unit imaging center. MATERIAL AND METHODS: An automated image quality analysis software using the discrete wavelet transform and multiresolution analysis was developed for the American College of Radiology accreditation phantom. The software was validated by analyzing 60 randomly selected phantom images from six mammography systems and 20 phantom images with different dose levels from one mammography system. The results were compared to a visual analysis made by four reviewers. Additionally, long-term image quality trends of a full-field digital mammography system and a computed radiography mammography system were investigated. RESULTS: The automated software produced feature detection levels comparable to visual analysis. The agreement was good in the case of fibers, while the software detected somewhat more microcalcifications and characteristic masses. Long-term follow-up via a quality assurance web portal demonstrated the feasibility of using the software for monitoring the performance of mammography systems in a multi-unit imaging center. CONCLUSION: Automated image quality analysis enables monitoring the performance of digital mammography systems in an efficient, centralized manner.


Assuntos
Automação , Mamografia/normas , Controle de Qualidade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Software , Humanos , Imagens de Fantasmas , Doses de Radiação
14.
Acad Radiol ; 26(1): 50-61, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29724675

RESUMO

RATIONALE AND OBJECTIVES: This phantom study aimed to evaluate low-dose (LD) chest computed tomography (CT) protocols using model-based iterative reconstruction (MBIR) for diagnosing lung metastases in patients with sarcoma. MATERIALS AND METHODS: An adult female anthropomorphic phantom was scanned with a 64-slice CT using four LD protocols and a standard-dose protocol. Absorbed organ doses were measured with 10 metal-oxide-semiconductor field-effect transistor dosimeters. Furthermore, Monte Carlo simulations were performed to estimate organ and effective doses. Image quality in terms of image noise, contrast, and resolution was measured from the CT images reconstructed with conventional filtered back projection, adaptive statistical iterative reconstruction, and MBIR algorithms. All the results were compared to the performance of the standard-dose protocol. RESULTS: Mean absorbed organ and effective doses were reduced by approximately 95% with the LD protocol (100-kVp tube voltage and a fixed 10-mA tube current) compared to the standard-dose protocol (120-kVp tube voltage and tube current modulation) while yielding an acceptable image quality for diagnosing round-shaped lung metastases. The effective doses ranged from 0.16 to 2.83 mSv in the studied protocols. The image noise, contrast, and resolution were maintained or improved when comparing the image quality of LD protocols using MBIR to the performance of the standard-dose chest CT protocol using filtered back projection. The small round-shaped lung metastases were delineated at levels comparable to the used protocols. CONCLUSIONS: Radiation exposure in patients can be reduced significantly by using LD chest CT protocols and MBIR algorithm while maintaining image quality for detecting round-shaped lung metastases.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Sarcoma/diagnóstico por imagem , Adulto , Algoritmos , Feminino , Humanos , Neoplasias Pulmonares/secundário , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Torácica/métodos , Sarcoma/secundário
15.
Pediatr Radiol ; 45(10): 1544-53, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25939873

RESUMO

BACKGROUND: Medical professionals need to exercise particular caution when developing CT scanning protocols for children who require multiple CT studies, such as those with craniosynostosis. OBJECTIVE: To evaluate the utility of ultra-low-dose CT protocols with model-based iterative reconstruction techniques for craniosynostosis imaging. MATERIALS AND METHODS: We scanned two pediatric anthropomorphic phantoms with a 64-slice CT scanner using different low-dose protocols for craniosynostosis. We measured organ doses in the head region with metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters. Numerical simulations served to estimate organ and effective doses. We objectively and subjectively evaluated the quality of images produced by adaptive statistical iterative reconstruction (ASiR) 30%, ASiR 50% and Veo (all by GE Healthcare, Waukesha, WI). Image noise and contrast were determined for different tissues. RESULTS: Mean organ dose with the newborn phantom was decreased up to 83% compared to the routine protocol when using ultra-low-dose scanning settings. Similarly, for the 5-year phantom the greatest radiation dose reduction was 88%. The numerical simulations supported the findings with MOSFET measurements. The image quality remained adequate with Veo reconstruction, even at the lowest dose level. CONCLUSION: Craniosynostosis CT with model-based iterative reconstruction could be performed with a 20-µSv effective dose, corresponding to the radiation exposure of plain skull radiography, without compromising required image quality.


Assuntos
Craniossinostoses/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Artefatos , Pré-Escolar , Humanos , Recém-Nascido , Razão Sinal-Ruído
16.
Radiat Prot Dosimetry ; 165(1-4): 226-30, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25836690

RESUMO

The connection between recorded volumetric CT dose index (CTDI vol) and determined mean fetal dose (Df) was examined from metal-oxide-semiconductor field-effect transistor dose measurements on an anthropomorphic female phantom in four stages of pregnancy in a 64-slice CT scanner. Automated tube current modulation kept the mean Df fairly constant through all pregnancy stages in trauma (4.4-4.9 mGy) and abdomino-pelvic (2.1-2.4 mGy) protocols. In pulmonary angiography protocol, the mean Df increased exponentially as the distance from the end of the scan range decreased (0.01-0.09 mGy). For trauma protocol, the relative mean Df as a function of gestational age were in the range 0.80-0.97 compared with the mean CTDI vol. For abdomino-pelvic protocol, the relative mean Df was 0.57-0.79 and for pulmonary angiography protocol, 0.01-0.05 compared with the mean CTDI vol, respectively. In conclusion, if the fetus is in the primary beam, the CTDI vol can be used as an upper estimate of the fetal dose. If the fetus is not in the primary beam, the fetal dose can be estimated by considering also the distance of the fetus from the scan range.


Assuntos
Feto/diagnóstico por imagem , Exposição Materna , Doses de Radiação , Tomografia Computadorizada por Raios X/efeitos adversos , Angiografia/efeitos adversos , Antropometria , Calibragem , Simulação por Computador , Feminino , Idade Gestacional , Humanos , Pulmão/diagnóstico por imagem , Metais/química , Método de Monte Carlo , Óxidos/química , Imagens de Fantasmas , Gravidez , Exposição à Radiação , Semicondutores , Tomógrafos Computadorizados