Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Foot Ankle Int ; 39(4): 415-425, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29337598

RESUMO

BACKGROUND: Temporary Kirschner wire fixation (K-wire) is a widely used, low-cost fixation method for the correction of hammertoe deformity. Reported complications associated with K-wires prompted the development of new implants over the past decade. However, there is a lack of literature on comparative studies analyzing functional outcomes using validated questionnaires. The purpose of this study was to analyze functional outcomes in patients who had undergone proximal interphalangeal joint fusion using 2 types of intramedullary implant, the Smart Toe and the TenFuse, and to compare them with the outcomes in patients treated with standard K-wire fixation. METHODS: A retrospective review of operative hammertoe correction by a single surgeon was performed in 96 patients followed for more than 12 months. Functional outcome was assessed using the Foot Function Index (FFI), the Short Form 36 (SF-36), and the 10-point visual analog scale (VAS) validated questionnaires. Complications and fusion rates were also evaluated. Several patients in the study underwent corrections in different toes; thus, a total of 186 toes were included in the study. From these, 65 toes (34.9%) were treated with K-wire fixation, 94 (50.5%) with Smart Toe titanium implant, and 27 (14.5%) with TenFuse allograft implant. RESULTS: No statistically significant differences in functional outcome and incidence of complications were observed among the 3 fixation groups, although the 2 intramedullary implants were associated with greater fusion rates and patient satisfaction. Breakage of the Smart Toe implant was significantly higher than that of the other fixations, with 10.6% of implants breaking within the first year postoperatively. SF-36 and VAS scores decreased 12 months after surgery for the 3 types of fixation, with no statistically significant differences observed. CONCLUSION: The use of Smart Toe and TenFuse implants provided operative outcomes comparable to those obtained using a K-wire fixation and slightly better patient satisfaction. Our results suggest that utilization of these implants for hammertoe correction was a reasonable choice that provided good alignment, pain reduction, and improved function at final follow-up. However, they are more expensive than K-wires. For this reason, in-depth cost-benefit studies would be required to justify their use as a standard treatment. LEVEL OF EVIDENCE: Level III, comparative series.


Assuntos
Síndrome do Dedo do Pé em Martelo/cirurgia , Articulação do Dedo do Pé/cirurgia , Fios Ortopédicos , Síndrome do Dedo do Pé em Martelo/fisiopatologia , Humanos , Medição da Dor , Estudos Retrospectivos , Articulação do Dedo do Pé/fisiopatologia , Resultado do Tratamento
2.
J Bacteriol ; 191(16): 5262-71, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19429621

RESUMO

We report here that gemfibrozil (GFZ) inhibits axenic and intracellular growth of Legionella pneumophila and of 27 strains of wild-type and multidrug-resistant Mycobacterium tuberculosis in bacteriological medium and in human and mouse macrophages, respectively. At a concentration of 0.4 mM, GFZ completely inhibited L. pneumophila fatty acid synthesis, while at 0.12 mM it promoted cytoplasmic accumulation of polyhydroxybutyrate. To assess the mechanism(s) of these effects, we cloned an L. pneumophila FabI enoyl reductase homolog that complemented for growth an Escherichia coli strain carrying a temperature-sensitive enoyl reductase and rendered the complemented E. coli strain sensitive to GFZ at the nonpermissive temperature. GFZ noncompetitively inhibited this L. pneumophila FabI homolog, as well as M. tuberculosis InhA and E. coli FabI.


Assuntos
Acil-CoA Desidrogenases/metabolismo , Escherichia coli/enzimologia , Genfibrozila/farmacologia , Legionella pneumophila/enzimologia , Macrófagos/microbiologia , Mycobacterium tuberculosis/enzimologia , Sequência de Aminoácidos , Animais , Células Cultivadas , Ácido Clofíbrico/farmacologia , Ativação Enzimática/efeitos dos fármacos , Escherichia coli/efeitos dos fármacos , Escherichia coli/crescimento & desenvolvimento , Gliceraldeído/análogos & derivados , Gliceraldeído/farmacologia , Humanos , Cinética , Legionella pneumophila/efeitos dos fármacos , Legionella pneumophila/crescimento & desenvolvimento , Legionella pneumophila/ultraestrutura , Metabolismo dos Lipídeos/efeitos dos fármacos , Camundongos , Testes de Sensibilidade Microbiana , Microscopia Eletrônica de Transmissão , Dados de Sequência Molecular , Mycobacterium tuberculosis/efeitos dos fármacos , Mycobacterium tuberculosis/crescimento & desenvolvimento , Propano/farmacologia , Homologia de Sequência de Aminoácidos
3.
Clin Orthop Relat Res ; (416): 135-44, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14646752

RESUMO

Twenty retrieved Scorpio posterior-stabilized implants were available for analysis. The mean implantation time was 22 months (range, 2 days-42 months). Favorable types and amounts of surface damage were seen on the tibiofemoral and backsides of these modular PE liners that had been packaged in an inert environment and then sterilized by gamma irradiation. Delamination represented only 0.1% of the total surface damage. Off-axis loading (varus malalignment) was associated with tibial component loosening but there was no evidence of peripheral damage of PE caused by edge loading. With this open-box design, hyperextension marks on the anterior aspect of the posterior-stabilized post from femoral component impingement occurred in 11 of 20 cases and was related to sagittal component positioning: excess tibial slope or increased tibial slope combined with a flexed femoral component. Unique coarse abrasions occurred in 16 of 20 cases and were the result of cement extrusion into the open box, especially with varus malalignment. These observations provide guidance for optimizing the surgical technique and the design of posterior-stabilized total knee components.


Assuntos
Prótese do Joelho , Tíbia/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polietileno , Falha de Prótese , Reoperação , Estatísticas não Paramétricas , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA