Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sarcoidosis Vasc Diffuse Lung Dis ; 33(3): 281-287, 2016 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-27758995

RESUMO

BACKGROUND: The best treatment of patients with external pulmonary vascular compression due to advanced sarcoidosis is unknown. OBJECTIVES: To report a single-center experience of percutaneous treatment for pulmonary vascular stenosis caused by external compression due to advanced sarcoidosis. METHODS: We report a case series of 5 patients with biopsy confirmed advanced sarcoidosis, seen at our academic institution with worsening dyspnea despite increase of immunosuppressive therapy. All patients were evaluated by a multidisciplinary team (cardiology, pulmonary and radiology) using a multi-modality approach, including chest-computed tomography angiography, ventilation/perfusion scintigraphy, pulmonary function test, 6-minute walk test and heart catheterization. RESULTS: Three out of five patients underwent pulmonary artery or vein angioplasty and stenting resulting in symptomatic improvement: Patient 1 had persistent symptomatic improvement measured by subjective and objective methods at 30 months; patient 2 required re-intervention due to recurrent pulmonary vein stenosis at 6-months followed by persistent improvement; and patient 3, had a procedure complicated with in-stent thrombosis requiring thrombolysis and anticoagulation with improvement. The remaining two patients were medically treated because underlying thromboembolic disease (patient 4) and diffuse pulmonary vein stenosis not amenable to percutaneous intervention (patient 5). CONCLUSIONS: Pulmonary vascular stenosis from external compression can be a rare but unrecognized caused of worsening symptoms in advanced sarcoidosis. Pulmonary vascular angioplasty and stenting can provide clinical benefit in select patients.


Assuntos
Angioplastia/instrumentação , Arteriopatias Oclusivas/terapia , Artéria Pulmonar , Pneumopatia Veno-Oclusiva/terapia , Sarcoidose Pulmonar/complicações , Stents , Adulto , Idoso , Arteriopatias Oclusivas/diagnóstico , Arteriopatias Oclusivas/etiologia , Cateterismo Cardíaco , Angiografia por Tomografia Computadorizada , Constrição Patológica , Teste de Esforço , Feminino , Humanos , Imunossupressores/uso terapêutico , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão , Flebografia/métodos , Artéria Pulmonar/diagnóstico por imagem , Pneumopatia Veno-Oclusiva/diagnóstico , Pneumopatia Veno-Oclusiva/etiologia , Recidiva , Retratamento , Sarcoidose Pulmonar/diagnóstico , Sarcoidose Pulmonar/tratamento farmacológico , Stents/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
2.
J Invasive Cardiol ; 28(7): 295-304, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27101969

RESUMO

OBJECTIVES: To evaluate the role of balloon annular sizing in transcatheter aortic valve replacement (TAVR). BACKGROUND: Multidetector cardiac computed tomography (MDCT) is the gold standard for aortic annular sizing in TAVR. Balloon sizing is increasingly used in patients with borderline annular size and severe calcification. A comparison between these two techniques is needed. METHODS: We retrospectively compared baseline characteristics and 30-day outcomes of patients undergoing balloon-expandable TAVR using annular MDCT or balloon sizing. Paravalvular leak (PVL) rates were compared adjusting for access site, valve generation, size, and valve calcification. RESULTS: A total of 205 patients underwent TAVR with MDCT (n = 110) or balloon sizing (n = 95). Balloon-sized patients were older (83 years vs 81 years; P=.03), had more valve calcification (60.2% vs 30.9%; P<.001), and underwent more minimalist TAVR (61.1% vs 40%; P=.03). Although we found no difference between balloon and MDCT sizing in rates of acute renal failure (3.2% vs 0.9%; P=.34), annular rupture (1.1% vs 1.8%; P>.99), ≥ mild PVL by angiography (40% vs 35.5%; P=.57), or 30-day transthoracic echocardiography (40.7% vs 29.3%; P=.78), balloon-sized patients had a higher aortic regurgitation index (≥25) of 74.4% vs 54.1% (P=.01). Thirty-day rates of ≥ moderate PVL were 7.0% with balloon and 5.7% with MDCT sizing (P=.34). Balloon sizing recommended a different valve size in 34.0% of patients who underwent both methods (n = 50). A different recommendation occurred more often in patients with moderate/severe annular calcification (50.0% vs 33.3%; P=.01) and non-tubular left ventricular outflow tracts (LVOTs) (70.6% vs 30.3%; P=.01). CONCLUSION: Balloon sizing can be a complement to MDCT for annular sizing in TAVR, especially in patients with moderate/severe annular calcification, borderline annular size, and non-tubular LVOT.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Cateterismo Cardíaco/métodos , Tomografia Computadorizada Multidetectores/métodos , Substituição da Valva Aórtica Transcateter , Obstrução do Fluxo Ventricular Externo , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Calcinose/diagnóstico por imagem , Precisão da Medição Dimensional , Ecocardiografia/métodos , Feminino , Humanos , Masculino , Tamanho do Órgão , Seleção de Pacientes , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Estados Unidos , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/patologia
3.
Ann Thorac Surg ; 100(6): 2167-73, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26277560

RESUMO

BACKGROUND: Chronic obstructive pulmonary disease (COPD) has been identified as a risk factor for morbidity and mortality after transcatheter aortic valve replacement (TAVR). We hypothesized that a portion of pulmonary dysfunction in patients with severe aortic stenosis may be of cardiac origin, and has potential to improve after TAVR. METHODS: A retrospective analysis was made of consecutive TAVR patients from April 2008 to October 2014. Of patients who had pulmonary function testing and serum B-type natriuretic peptide data available before and after TAVR, 58 were found to have COPD (26 mild, 14 moderate, and 18 severe). Baseline variables and operative outcomes were explored along with changes in pulmonary function. Multiple regression analyses were performed to adjust for preoperative left ventricular ejection fraction and glomerular filtration rate. RESULTS: Comparison of pulmonary function testing before and after the procedure among all COPD categories showed a 10% improvement in forced vital capacity (95% confidence interval: 4% to 17%) and a 12% improvement in forced expiratory volume in 1 second (95% confidence interval: 6% to 19%). There was a 29% decrease in B-type natriuretic peptide after TAVR (95% confidence interval: -40% to -16%). An improvement of at least one COPD severity category was observed in 27% of patients with mild COPD, 64% of patients with moderate COPD, and 50% of patients with severe COPD. There was no 30-day mortality in any patient group. CONCLUSIONS: In patients with severe aortic stenosis, TAVR is associated with a significant improvement of pulmonary function and B-type natriuretic peptide. After TAVR, the reduction in COPD severity was most evident in patients with moderate and severe pulmonary dysfunction.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Feminino , Volume Expiratório Forçado/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Doença Pulmonar Obstrutiva Crônica/cirurgia , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento , Capacidade Vital/fisiologia
4.
J Thorac Cardiovasc Surg ; 150(4): 833-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26318351

RESUMO

BACKGROUND: A minimalist approach for transcatheter aortic valve replacement (MA-TAVR) utilizing transfemoral access under conscious sedation and transthoracic echocardiography is increasing in popularity. This relatively novel technique may necessitate a learning period to achieve proficiency in performing a successful and safe procedure. This report evaluates our MA-TAVR cohort with specific characterization between our early, midterm, and recent experience. METHODS: We retrospectively reviewed 151 consecutive patients who underwent MA-TAVR with surgeons and interventionists equally as primary operator at Emory University between May 2012 and July 2014. Our institution had performed 300 TAVR procedures before implementation of MA-TAVR. Patient characteristics and early outcomes were compared using Valve Academic Research Consortium 2 definitions among 3 groups: group 1 included the first 50 patients, group 2 included patients 51 to 100, and group 3 included patients 101 to 151. RESULTS: Median age for all patients was 84 years and similar among groups. The majority of patients were men (56%) and the median ejection fraction for all patients was 55% (interquartile range, 38.0%-60.0%). The majority of patients were high-risk surgical candidates with a median Society of Thoracic Surgeons Predicted Risk of Mortality of 10.0% and similar among groups. The overall major stroke rate was 3.3%, major vascular complications occurred in 3% of patients, and greater-than-mild paravalvular leak rate was 7%. In-hospital mortality and morbidity were similar among all 3 groups. CONCLUSIONS: In a high-volume TAVR center, transition to MA-TAVR is feasible with acceptable outcomes and a diminutive procedural learning curve. We advocate for TAVR centers to actively pursue the minimalist technique with equal representation by cardiologists and surgeons.


Assuntos
Cardiologia/métodos , Artéria Femoral , Cirurgia Torácica/métodos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/normas , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Curva de Aprendizado , Masculino , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA