Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
1.
Biomolecules ; 13(9)2023 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-37759829

RESUMO

BACKGROUND: We investigated the relationship of matrix metalloproteinases (MMPs), cardio-ankle vascular index (CAVI), and Gray-Scale Median (GSM) score with the severity and vulnerability of carotid atherosclerosis and major adverse cardiovascular events (MACE) during follow-up of carotid artery revascularization. METHODS: We enrolled 262 patients undergoing carotid revascularization therapy (GRT), 109 asymptomatic patients with low-grade carotid stenosis (40-70%) receiving conservative treatment (GCT), and 92 age- and sex-matched control subjects without carotid atherosclerosis (GCO). All participants underwent carotid ultrasound and we assessed at baseline clinical parameters, metabolic profile, CAVI, GSM, and circulating levels of hsCRP, MMP-3,-7,-9, and TIMP-1. RESULTS: Both GRT and GCT presented with elevated CAVI, MMPs, and TIMP-1 levels compared to GCO (p < 0.001). The escalation highly correlated to the presence of symptoms or paralleled the degree of carotid stenosis (p < 0.001). During follow-up (mean duration: 55 months), 51 GRT patients experienced MACE unrelated to the revascularization procedure. Within GRT, diabetes (HR: 2.07; CI: 1.55-2.78, p < 0.001), smoking (HR: 1.67; CI: 1.35-1.95, p < 0.001), high CAVI (HR: 1.22; CI: 1.09-1.43, p = 0.023) and MMP-9 (HR: 1.44; CI: 1.29-2.15, p = 0.005), and low GSM (HR: 1.40; CI: 1.16-2.12, p = 0.002) independently predicted MACE occurrences, despite the optimum medical therapy. CONCLUSIONS: Novel imaging and biochemical biomarkers were positively associated with atherosclerosis severity, while CAVI, MMP-9, and low GSM showed a positive, independent relationship with MACE after carotid revascularization, describing "vulnerable patients".


Assuntos
Doenças das Artérias Carótidas , Estenose das Carótidas , Humanos , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Metaloproteinase 9 da Matriz , Inibidor Tecidual de Metaloproteinase-1 , Biomarcadores
2.
Aorta (Stamford) ; 10(5): 235-241, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36539115

RESUMO

BACKGROUND: Coarctation of the aorta (CoA) is a congenital cardiovascular malformation involving narrowing of the thoracic aorta just distal to the left subclavian artery. The aim of our study was to evaluate the hemodynamic effects of endovascular treatment for CoA by using invasive aortic catheterization. METHODS: All patients with CoA who underwent treatment by aortic stent implantation between September 1, 2003, and February 1, 2019, at the "Onassis Cardiac Surgery Center," in Athens, Greece, were evaluated. Patients were treated with either bare (uncovered) Cheatham-Platinum (bCP) or covered Cheatham-Platinum (cCP) stent implantations. Invasive aortic pressure measurements were recorded before and after the endovascular intervention. RESULTS: A total of 48, eight zig CP stents, comprising 24 bCP and 24 cCP stents were implanted in 47 patients. The mean aortic diameter (mm) at the CoA lesion increased from 9.7 ± 3.3 to 19.2 ± 2.9 mm (p <0.01) after the endovascular procedure. The invasive mean blood pressure (BP; mm Hg) from catheterization in the descending aorta increased (before = 114.2 ± 12.8 vs. after = 135.5 ± 28.1; p <0.01), while the invasive mean BP (mm Hg) from catheterization in the ascending aorta was decreased (before = 156.8 ± 25.0 vs. after = 138.4 ± 27.5; p <0.01) after the intervention. The mean aortic BP gradient decreased in both types of stents after intervention (BP gradient among patients with cCP stents = 30.9 +/- 23.6 mmHg and BP gradient among patients with bCP stents = 38.0 +/-23.1 mmHg). However, there was no statistically significant difference between the two types of stents; p = 0.36. CONCLUSIONS: Invasive aortic catheterization provided evidence that endovascular stenting with either bare or covered stents is efficient in treating patients with CoA.

4.
Ann Vasc Surg ; 76: 202-210, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34437963

RESUMO

INTRODUCTION: Aortic graft infection remains a considerable clinical challenge, and it is unclear which variables are associated with adverse outcomes among patients undergoing partial resection. METHODS: A retrospective, multi-institutional study of patients who underwent partial resection of infected aortic grafts from 2002 to 2014 was performed using a standard database. Baseline demographics, comorbidities, operative, and postoperative variables were recorded. The primary outcome was mortality. Descriptive statistics, Kaplan-Meier (KM) survival analysis, and Cox regression analysis were performed. RESULTS: One hundred fourteen patients at 22 medical centers in 6 countries underwent partial resection of an infected aortic graft. Seventy percent were men with median age 70 years. Ninety-seven percent had a history of open aortic bypass graft: 88 (77%) patients had infected aortobifemoral bypass, 18 (16%) had infected aortobiiliac bypass, and 1 (0.8%) had an infected thoracic graft. Infection was diagnosed at a median 4.3 years post-implant. All patients underwent partial resection followed by either extra-anatomic (47%) or in situ (53%) vascular reconstruction. Median follow-up period was 17 months (IQR 1, 50 months). Thirty-day mortality was 17.5%. The KM-estimated median survival from time of partial resection was 3.6 years. There was no significant survival difference between those undergoing in situ reconstruction or extra-anatomic bypass (P = 0.6). During follow up, 72% of repairs remained patent and 11% of patients underwent major amputation. On univariate Cox regression analysis, Candida infection was associated with increased risk of mortality (HR 2.4; P = 0.01) as well as aortoenteric fistula (HR 1.9, P = 0.03). Resection of a single graft limb only to resection of abdominal (graft main body) infection was associated with decreased risk of mortality (HR 0.57, P = 0.04), as well as those with American Society of Anesthesiologists classification less than 3 (HR 0.35, P = 0.04). Multivariate analysis did not reveal any factors significantly associated with mortality. Persistent early infection was noted in 26% of patients within 30 days postoperatively, and 39% of patients were found to have any post-repair infection during the follow-up period. Two patients (1.8%) were found to have a late reinfection without early persistent postoperative infection. Patients with any post-repair infection were older (67 vs. 60 years, P = 0.01) and less likely to have patent repairs during follow up (59% vs. 32%, P = 0.01). Patients with aortoenteric fistula had a higher rate of any post-repair infection (63% vs. 29%, P < 0.01) CONCLUSION: This large multi-center study suggests that patients who have undergone partial resection of infected aortic grafts may be at high risk of death or post-repair infection, especially older patients with abdominal infection not isolated to a single graft limb, or with Candida infection or aortoenteric fistula. Late reinfection correlated strongly with early persistent postoperative infection, raising concern for occult retained infected graft material.


Assuntos
Aorta/cirurgia , Implante de Prótese Vascular/efeitos adversos , Prótese Vascular/efeitos adversos , Remoção de Dispositivo , Procedimentos Endovasculares/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Idoso , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/mortalidade , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
5.
Vasc Endovascular Surg ; 55(8): 804-810, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34114528

RESUMO

PURPOSE: The aim of the present study was to investigate a potential difference on the arterial stiffness among aneurysm patients and non-aneurysm controls, as well as to explore potential changes between patients treated either with endovascular or open repair. MATERIALS AND METHODS: A 110 patients with an infrarenal AAA were prospectively enrolled in this study. Fifty-six patients received an EVAR, whereas 54 patients received an open surgical repair. Moreover, 103 gender and age-matched subjects without AAA served as controls. The cardio-ankle vascular index (CAVI) was applied for measurement of the arterial stiffness. RESULTS: CAVI values were statistically higher in the AAA patients when compared with control subjects. Although at 48 hours postoperatively the CAVI values were increased in both groups when compared to baseline values, the difference in CAVI had a tendency to be higher in the open group compared to the endovascular group. At 6 months of follow up the CAVI values returned to the baseline for the patients of the open repair group. However, in the endovascular group CAVI values remained higher when compared with the baseline values. CONCLUSION: Patients with AAAs demonstrated a higher value of CAVI compared to healthy controls. A significant increase of arterial stiffness in both groups during the immediate postoperative period was documented. The increase in arterial stiffness remained significant at 6 months in EVAR patients. Further studies are needed to elucidate the impact of a decreased aortic compliance after stentgraft implantation on the cardiac function of patients with AAA.


Assuntos
Aneurisma da Aorta Abdominal , Procedimentos Endovasculares , Rigidez Vascular , Tornozelo , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/efeitos adversos , Humanos , Resultado do Tratamento
7.
Ann Vasc Surg ; 74: 497-501, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33819583

RESUMO

Preservation of the hypogastric circulation is of major clinical importance in cases of endovascular aneurysm repair (EVAR) for ruptured abdominal aortic aneurysm (rAAA). Pelvic ischemia can be detrimental and significantly increase post-operative morbidity and mortality. However, the application of a side branch device or a bell-bottom graft is not possible in ruptured aortoiliac aneurysms (due to off-the-shelf unavailability and/or prolonged operative time) and in most cases pelvic circulation may have to be sacrificed. We report a case of a rAAA with bilateral common iliac artery (CIA) aneurysms that was successfully repaired with an aorto-uni-iliac (AUI) endograft, a cross-femoral bypass, and an inverted-U shaped contralateral EIA to IIA endovascular bypass. The procedure is described in detail and certain technical points are further discussed. The steps in cases where the aneurysm has ruptured are different compared to elective repairs and vascular surgeons need to be aware of certain pitfalls. This strategy may be feasible in the acute setting and permits preservation of the hypogastric circulation with the combination of standard techniques and grafts that are readily available in most institutions.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Aneurisma Ilíaco/cirurgia , Enxerto Vascular/métodos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Ruptura Aórtica/diagnóstico por imagem , Prótese Vascular , Angiografia por Tomografia Computadorizada , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade
8.
Vasa ; 50(4): 270-279, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33739140

RESUMO

Background: Abdominal wall hernias (AWHs) share common epidemiological characteristics with abdominal aortic aneurysms (AAAs), typically presenting in male population and older ages. Prior reports have associated those two disease entities. Our objective was to perform a systematic review and meta-analysis and examine whether AAA rates are higher among patients with AWH vs controls and whether the incidence of AWH was higher among patients with AAA vs patients without AAA. Methods: We performed a systematic review and meta-analysis according to the PRISMA guidelines. The Medline database was searched up to July 31, 2020. A random effects meta-analysis was performed. Results: In total, 17 articles and 738,972 participants were included in the systematic review, while 107,578 patients were eligible for the meta-analysis. Among four studies investigating the incidence of AAA in patients with hernias, AAA was more common in patients with hernias, compared to patients without hernias. [OR: 2.53, 95% CI: 1.24-5.16, I2=81.6%]. Among thirteen studies that compared patients with known AAA vs no AAA, the incidence of hernias was higher in patients with AAA, compared with patients without AAA [OR: 2.27, 95% CI: 1.66-3.09, I2=84.6%]. Conclusions: Our study findings indicate that a strong association between AWH and AAA exists. AWHs could therefore be used as an additional selection criterion for screening patients for AAA, apart from age, gender, family history and smoking.


Assuntos
Aneurisma da Aorta Abdominal , Hérnia Abdominal , Idoso , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Fatores de Risco
9.
J Vasc Surg ; 73(3): 1110-1111, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33632497
10.
J Vasc Surg ; 73(1): 210-221.e1, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32445832

RESUMO

OBJECTIVE: The optimal revascularization modality in secondary aortoenteric fistula (SAEF) remains unclear in the literature. The purpose of this investigation was to determine the revascularization approach associated with the lowest morbidity and mortality using real-world data in patients with SAEF. METHODS: A retrospective, multi-institutional study of SAEF from 2002 to 2014 was performed using a standardized database. Baseline demographics, comorbidities, and operative and postoperative variables were recorded. The primary outcome was long-term mortality. Descriptive statistics, Kaplan-Meier survival analysis, and univariate and multivariate analyses were performed. RESULTS: During the study period, 182 patients at 34 institutions from 11 countries presented with SAEF (median age, 72 years; 79% male). The initial aortic procedures that resulted in SAEF were 138 surgical grafts (76%) and 42 endografts (23%), with 2 unknown; 102 of the SAEFs (56%) underwent complete excision of infected aortic graft material, followed by in situ (in-line) bypass (ISB), including antibiotic-soaked prosthetic graft (53), autogenous femoral vein (neoaortoiliac surgery; 17), cryopreserved allograft (28), and untreated prosthetic grafts (4). There were 80 patients (44%) who underwent extra-anatomic bypass (EAB) with infected graft excision. Overall median Kaplan-Meier estimated survival was 319 days (interquartile range, 20-2410 days). Stratified by EAB vs ISB, there was no significant difference in Kaplan-Meier estimated survival (P = .82). In comparing EAB vs ISB, EAB patients were older (74 vs 70 years; P = .01), had less operative hemorrhage (1200 mL vs 2000 mL; P = .04), were more likely to initiate dialysis within 30 days postoperatively (15% vs 5%; P = .02), and were less likely to experience aorta-related hemorrhage within 30 days postoperatively (3% aortic stump dehiscence vs 11% anastomotic rupture; P = .03). There were otherwise no significant differences in presentation, comorbidities, and intraoperative or postoperative variables. Multivariable Cox regression showed that the duration of antibiotic use (hazard ratio, 0.92; 95% confidence interval, 0.86-0.98; P = .01) and rifampin use at time of discharge (hazard ratio, 0.20; 95% confidence interval, 0.05-0.86; P = .03) independently decreased mortality. CONCLUSIONS: These data suggest that ISB does not offer a survival advantage compared with EAB and does not decrease the risk of postoperative aorta-related hemorrhage. After repair, <50% of SAEF patients survive 10 months. Each week of antibiotic use decreases mortality by 8%. Further study with risk modeling is imperative for this population.


Assuntos
Implante de Prótese Vascular/métodos , Fístula Intestinal/cirurgia , Stents , Fístula Vascular/cirurgia , Idoso , Feminino , Seguimentos , Humanos , Fístula Intestinal/diagnóstico , Fístula Intestinal/mortalidade , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia , Fístula Vascular/diagnóstico , Fístula Vascular/mortalidade
13.
J Vasc Surg ; 72(4): 1489-1498.e1, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32422272

RESUMO

OBJECTIVE: Transcervical carotid artery stenting (CAS) has emerged as an alternative to transfemoral CAS. An earlier systematic review from our group (n = 12 studies; 739 transcervical CAS procedures [489/739 with flow reversal]) demonstrated that transcervical CAS is a safe procedure associated with a low incidence of stroke and complications. Since then, new studies have been published adding nearly 1600 patients to the literature. We aimed to update our early systematic review and also to perform a meta-analysis to investigate outcomes specifically after transcervical CAS with flow reversal. METHODS: An electronic search of PubMed/MEDLINE, Embase, and the Cochrane databases was carried out to identify studies reporting outcomes after transcervical CAS with flow reversal. Crude event rates for outcomes of interest were estimated by simple pooling of data. A proportion meta-analysis was also performed to estimate pooled outcome rates. RESULTS: A total of 18 studies (n = 2110 transcervical CAS procedures with flow reversal) were identified. A high technical success (98.25%) and a low mortality rate (0.48%) were recorded. The crude rates of major stroke, minor stroke, transient ischemic attack, and myocardial infarction (MI) were 0.71%, 0.90%, 0.57%, and 0.57%, respectively; a cranial nerve injury occurred in 0.28% of the procedures. A neck hematoma was reported in 1.04% of the procedures, and a carotid artery dissection occurred in 0.76% of the interventions; in 1.09% of the cases, conversion to carotid endarterectomy was required. After a meta-analysis was undertaken, the pooled technical success rate was 98.69% (95% confidence interval [CI], 97.19-99.70). A pooled mortality rate of 0.04% (95% CI, 0.00-0.29) was recorded. The pooled rate of any type of neurologic complications was 1.88 (95% CI, 1.24-2.61), whereas the pooled rates of major stroke, minor stroke, and transient ischemic attack were 0.12% (95% CI, 0.00-0.46), 0.15% (95% CI, 0.00-0.50), and 0.01% (95% CI, 0.00-0.22), respectively. The pooled rate of bradycardia/hypotension was 10.21% (95% CI, 3.99-18.51), whereas the pooled rate of MI was 0.08% (95% CI, 0.00-0.39). A neck hematoma after transcervical CAS was recorded in 1.51% (95% CI, 0.22-3.54) of the procedures; in 0.74% (95% CI, 0.05-1.95) of the interventions, conversion to CEA was required. Finally, a carotid artery dissection during transcervical CAS occurred in 0.47% (95% CI, 0.00-1.38) of the procedures. CONCLUSIONS: This updated systematic review and meta-analysis demonstrated that transcervical CAS with flow reversal is associated with high technical success, almost zero mortality, and low rates of major stroke, minor stroke, MI, and complications.


Assuntos
Derivação Arteriovenosa Cirúrgica/efeitos adversos , Estenose das Carótidas/cirurgia , Complicações Pós-Operatórias/epidemiologia , Derivação Arteriovenosa Cirúrgica/instrumentação , Derivação Arteriovenosa Cirúrgica/métodos , Artéria Carótida Primitiva/cirurgia , Estenose das Carótidas/mortalidade , Veia Femoral/cirurgia , Humanos , Incidência , Ataque Isquêmico Transitório/epidemiologia , Ataque Isquêmico Transitório/etiologia , Veias Jugulares/cirurgia , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Complicações Pós-Operatórias/etiologia , Medição de Risco/estatística & dados numéricos , Fatores de Risco , Stents , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
15.
J Vasc Surg ; 71(6): 2133-2144, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31901362

RESUMO

OBJECTIVE: Common iliac artery aneurysms are present in more than a third of patients with abdominal aortic aneurysm and may pose a challenge during open and endovascular repair. Although embolization of the internal iliac artery is an established method, it may be complicated with buttock claudication, erectile dysfunction, colon ischemia, and pelvic necrosis. Iliac branch devices (IBDs), which permit preservation of the hypogastric artery, have been used to prevent these complications. We conducted a meta-analysis to assess the safety and outcomes of IBDs and to explore potential differences between the commercially available types of IBDs. METHODS: The meta-analysis was conducted using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. After review of the literature, 36 eligible studies with a total of 1502 patients were included in our study. A meta-analysis was performed with investigation of the following outcomes: technical success rate, 30-day mortality, 30-day patency, follow-up patency, endoleak, buttock claudication, and IBD-associated reintervention. Furthermore, we conducted a subgroup meta-analysis by commercial type of endograft among the outcomes of interest. RESULTS: Among all eligible studies, technical success of the method was 97.35% (95% confidence interval [CI], 96.27-98.29). The endoleak rate postoperatively and during the follow-up period was 12.68% (95% CI, 8.80-17.07). The 30-day patency of IBDs was estimated at 97.59% (95% CI, 96.49-98.54), whereas follow-up patency was 94.32% (95% CI, 91.70-96.54). Furthermore, reintervention rate associated with IBDs was 6.96% (95% CI, 5.10-9.03), and buttock claudication during the follow-up period was 2.15% (95% CI, 1.25-3.22). CONCLUSIONS: IBD seems to be a safe, feasible, and effective technique for the treatment of aortoiliac aneurysms in select patients with suitable anatomy. Further results are awaited to explore the long-term efficacy and durability of these devices.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Aneurisma Ilíaco/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/fisiopatologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Fluxo Sanguíneo Regional , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
16.
J Neurol Sci ; 409: 116590, 2020 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-31811985

RESUMO

BACKROUND & PURPOSE: Perioperative neck hematoma (PNH) requiring re-intervention is an important complication after carotid endarterectomy (CEA). There are limited data regarding the potential risk factors associated with PNH. The aim of this prospective, multicenter study was to document the rate of PNH in symptomatic carotid artery stenosis (sCAS) patients treated with CEA within the first 14 days of cerebrovascular symptom onset and to identify possible predictors of this complication. METHODS: Patients with non-disabling (mRS ≤ 2) acute ischemic stroke or transient ischemic attack due to sCAS (≥70%) underwent CEA at three stroke-centers during a seven-year period. PNH requiring surgical re-intervention or transfusion during a 30-day follow-up period was determined by the attending surgeon but was also confirmed by an independent neurologist. RESULTS: A total of 280 patients with sCAS underwent CEA within 14 days of ictus. PNH occurred in 10 cases (3.6%; 95%CI: 1.4%-5.8%). Pretreatment with therapeutic anticoagulation (TA) and history of atrial fibrillation were more prevalent in patients with PNH (20% vs. 3.1%, p= 0.047 & 30% vs. 8.2%, p = 0.05 respectively). Elapsed time between symptom onset and carotid surgery, pretreatment with dual antiplatelets, intravenous thrombolysis or prophylactic anticoagulation were not related to PNH in univariable analyses. Pretreatment with TA was independently associated with higher likelihood of PNH [OR: 10.69, 95%CI (1.74-65.72), p = 0.011] in multivariate logistic regression models adjusting for potential confounders. CONCLUSION: PNH is uncommon in patients with sCAS that are operated during the first 14 days of ictus. Pretreatment with TA appears to be associated with higher risk of PNH.


Assuntos
Estenose das Carótidas/diagnóstico por imagem , Endarterectomia das Carótidas/efeitos adversos , Hematoma/diagnóstico por imagem , Ataque Isquêmico Transitório/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Acidente Vascular Cerebral/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/administração & dosagem , Estenose das Carótidas/cirurgia , Transtornos Cerebrovasculares/diagnóstico por imagem , Transtornos Cerebrovasculares/etiologia , Transtornos Cerebrovasculares/prevenção & controle , Endarterectomia das Carótidas/tendências , Feminino , Hematoma/etiologia , Hematoma/prevenção & controle , Humanos , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/prevenção & controle , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fatores de Tempo
18.
Vasc Endovascular Surg ; 53(7): 572-582, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31382837

RESUMO

BACKGROUND-AIM: Limited data exist concerning the fluid dynamic changes induced by endovascular aortic repair with fenestrated and chimney graft modalities in pararenal aneurysms. We aimed to investigate and compare the wall shear stress (WSS) and flow dynamics for the branch vessels before and after endovascular aortic repair with fenestrated and chimney techniques. METHODS: Modeling was done for patient specific pararenal aortic aneurysms employing fenestrated and chimney grafts (Materialise Mimics 10.0) before and after the endovascular procedure, using computed tomography scans of patients. Surface and spatial grids were created using the ANSYS CFD meshing software 2019 R2. Assessment of blood flow, streamlines, and WSS before and after aneurysm repair was performed. RESULTS: The endovascular repair with chimney grafts leaded to a 43% to 53% reduction in perfusion in renal arteries. In fenestrated reconstruction, we observed a 15% reduced perfusion in both renal arteries. In both cases, we observed a decrease in the recirculation phenomena of the aorta after endovascular repair. Concerning the grafts of the renal arteries, we observed in both the transverse and longitudinal axes low WSS regions with simultaneous recirculation of the flow 1 cm distal to the ostium sites in both aortic graft models. High WSS regions appeared in the sites of ostium. CONCLUSIONS: We observed reduced renal perfusion in chimney grafts compared to fenestrated grafts, probably caused by the long and kinked characteristics of these devices.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Tomada de Decisão Clínica , Procedimentos Endovasculares/instrumentação , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Hemodinâmica , Humanos , Hidrodinâmica , Seleção de Pacientes , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Valor Preditivo dos Testes , Desenho de Prótese , Interpretação de Imagem Radiográfica Assistida por Computador , Circulação Renal , Estresse Mecânico , Resultado do Tratamento
19.
Ann Vasc Surg ; 61: 455-458, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31344469

RESUMO

BACKGROUND: Type Ia endoleak due to inadequate seal at the proximal end of the endograft is not infrequent during the initial operation. However, repeated attempts at balloon inflation or over-dilatation of the balloon can produce high axial pressures and can lead to aortic neck rupture with hemodynamic instability. METHODS: The purpose of the paper is to present a useful technique for simultaneously treating a type Ia endoleak and aortic neck rupture during endovascular abdominal aortic aneurysm repair. RESULTS: The technique for treating a type Ia endoleak has been described, but it was used for the first time to treat simultaneously a type Ia endoleak and rupture of the aortic neck with active bleeding during endovascular abdominal aortic aneurysm repair. After laparotomy, the left renal vein was ligated and a proximal control was achieved with placement of a vascular clamp above the renal arteries. Effective external banding of the infrarenal neck was performed with two 10-mm polyester Dacron limbs tied in the same fashion, close to one another, and parallel just below the renal arteries. We describe the steps of the surgical technique in detail and we analyze crucial issues associated with the technique. CONCLUSIONS: In this paper, we presented a useful technique for simultaneously treating a type Ia endoleak and aortic neck rupture during endovascular abdominal aortic aneurysm repair. Effective external banding of the infrarenal neck led to control of the hemorrhage and exclusion of the blood flow in the aneurysm sac.


Assuntos
Angioplastia com Balão/efeitos adversos , Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Perda Sanguínea Cirúrgica/prevenção & controle , Implante de Prótese Vascular/efeitos adversos , Endoleak/cirurgia , Hemostasia Cirúrgica , Idoso de 80 Anos ou mais , Angioplastia com Balão/instrumentação , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/etiologia , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Conversão para Cirurgia Aberta , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Humanos , Masculino , Stents , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA